Volumn 116, Issue 1, 2007, Pages 126-130

Risk of cellular phone interference with an implantable loop recorder

Author keywords

Cellular phone interference; Electrocardiographic artifacts; Electromagnetic interference; Implantable loop recorder

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFACT; CLINICAL ARTICLE; DEVICE; ELECTROCARDIOGRAM; ELECTROCARDIOGRAPHY MONITORING; FEMALE; HUMAN; IMPLANT; MALE; MOBILE PHONE; PRIORITY JOURNAL; RECORDER; RISK ASSESSMENT; SIGNAL PROCESSING;

EID: 33846889521     PISSN: 01675273     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijcard.2006.04.044     Document Type: Article
Times cited : (11)

References (16)
  • 1
    • 23044479016 scopus 로고    scopus 로고
    • The effects of mobile phones on pacemaker function
    • Tandogan I., Temizhan A., Yetkin E., et al. The effects of mobile phones on pacemaker function. Int J Cardiol 103 1 (2005) 51-58
    • (2005) Int J Cardiol , vol.103 , Issue.1 , pp. 51-58
    • Tandogan, I.1    Temizhan, A.2    Yetkin, E.3
  • 2
    • 0033791857 scopus 로고    scopus 로고
    • Electromagnetic interference of an implantable loop recorder by commonly encountered electronic devices
    • De Cock C., Spruijt H., Van Campen L., Plu A., and Visser C. Electromagnetic interference of an implantable loop recorder by commonly encountered electronic devices. Pacing Clin Electrophysiol 23 (2000) 1516-1518
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 1516-1518
    • De Cock, C.1    Spruijt, H.2    Van Campen, L.3    Plu, A.4    Visser, C.5
  • 3
    • 23944473681 scopus 로고    scopus 로고
    • Interference by cellular telephone with an implantable loop recorder
    • Trigano A., Blandeau O., and Levy S. Interference by cellular telephone with an implantable loop recorder. J Interv Card Electrophysiol 12 3 (2005) 237-240
    • (2005) J Interv Card Electrophysiol , vol.12 , Issue.3 , pp. 237-240
    • Trigano, A.1    Blandeau, O.2    Levy, S.3
  • 4
    • 33846851338 scopus 로고    scopus 로고
    • Technical manual: Reveal® Plus 9526, insertable loop recorder system, model 9809 software series 2.0, 2001, Medtronic Inc., Minneapolis, MN, USA.
  • 5
    • 0034313034 scopus 로고    scopus 로고
    • Analysis of the influence of the power control and discontinuous transmission on RF exposure with GSM mobile phones
    • Wiart J., Dale C., Bosisio A.V., and Le Cornec A. Analysis of the influence of the power control and discontinuous transmission on RF exposure with GSM mobile phones. IEEE Trans Electromagn Compat 42 4 (2000) 376-385
    • (2000) IEEE Trans Electromagn Compat , vol.42 , Issue.4 , pp. 376-385
    • Wiart, J.1    Dale, C.2    Bosisio, A.V.3    Le Cornec, A.4
  • 6
    • 2442532587 scopus 로고    scopus 로고
    • Insertable loop recorder use for detection of intermittent arrhythmias
    • Krahn A., Klein G., Skanes A., and Yee R. Insertable loop recorder use for detection of intermittent arrhythmias. Pacing Clin Electrophysiol 27 (2004) 657-664
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 657-664
    • Krahn, A.1    Klein, G.2    Skanes, A.3    Yee, R.4
  • 7
    • 0042490666 scopus 로고    scopus 로고
    • Cost implications of testing strategy in patients with syncope
    • Krahn A., Klein G., Yee R., Hoch J., and Skanes A. Cost implications of testing strategy in patients with syncope. J Am Coll Cardiol 42 (2003) 495-501
    • (2003) J Am Coll Cardiol , vol.42 , pp. 495-501
    • Krahn, A.1    Klein, G.2    Yee, R.3    Hoch, J.4    Skanes, A.5
  • 9
    • 11144354213 scopus 로고    scopus 로고
    • Orthotripsy mimicking asystole
    • Vlay S. Orthotripsy mimicking asystole. Pacing Clin Electrophysiol 27 (2004) 563
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 563
    • Vlay, S.1
  • 10
    • 17144433057 scopus 로고    scopus 로고
    • Artefact mimicking tachycardia during magnetic resonance imaging in a patient with an implantable loop recorder
    • [http://www.heartjnl.com/cgi/content/full/89/3/e10]
    • Gimbel J., and Wilkoff B. Artefact mimicking tachycardia during magnetic resonance imaging in a patient with an implantable loop recorder. Heart 89 (2003) e10. http://www.heartjnl.com/cgi/content/full/89/3/e10 [http://www.heartjnl.com/cgi/content/full/89/3/e10]
    • (2003) Heart , vol.89
    • Gimbel, J.1    Wilkoff, B.2
  • 11
    • 0037530284 scopus 로고    scopus 로고
    • Novel use of an insertable loop recorder
    • [http://www.heartjnl.com/cgi/content/full/89/6/e18]
    • Gimbel J. Novel use of an insertable loop recorder. Heart 89 (2003) e18. http://www.heartjnl.com/cgi/content/full/89/6/e18 [http://www.heartjnl.com/cgi/content/full/89/6/e18]
    • (2003) Heart , vol.89
    • Gimbel, J.1
  • 12
    • 0033592762 scopus 로고    scopus 로고
    • Clinical consequences of electrocardiographic artifact mimicking ventricular tachycardia
    • Knight B., Pelosi F., Michaud G., Strickberger S., and Morady F. Clinical consequences of electrocardiographic artifact mimicking ventricular tachycardia. N Engl J Med 341 (1999) 1270-1274
    • (1999) N Engl J Med , vol.341 , pp. 1270-1274
    • Knight, B.1    Pelosi, F.2    Michaud, G.3    Strickberger, S.4    Morady, F.5
  • 13
    • 0036345639 scopus 로고    scopus 로고
    • Common electrocardiographic artifacts mimicking arrhythmias in ambulatory monitoring
    • Marquez M., Colin L., Guevara M., Iturralde P., and Hermosillo A. Common electrocardiographic artifacts mimicking arrhythmias in ambulatory monitoring. Am Heart J 144 (2002) 187-197
    • (2002) Am Heart J , vol.144 , pp. 187-197
    • Marquez, M.1    Colin, L.2    Guevara, M.3    Iturralde, P.4    Hermosillo, A.5
  • 15
    • 3242813811 scopus 로고    scopus 로고
    • Differential electrocardiographic artifact from implanted thalamic stimulator
    • Khan I. Differential electrocardiographic artifact from implanted thalamic stimulator. Int J Cardiol 96 (2004) 285-286
    • (2004) Int J Cardiol , vol.96 , pp. 285-286
    • Khan, I.1
  • 16
    • 0141570962 scopus 로고    scopus 로고
    • Comparison of automatic and patient-activated arrhythmia recordings by implantable loop recorders in the evaluation of syncope
    • Ermis C., Zhu A., Pham S., et al. Comparison of automatic and patient-activated arrhythmia recordings by implantable loop recorders in the evaluation of syncope. Am J Cardiol 92 (2003) 815-819
    • (2003) Am J Cardiol , vol.92 , pp. 815-819
    • Ermis, C.1    Zhu, A.2    Pham, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.