메뉴 건너뛰기




Volumn 55, Issue 6, 2017, Pages 777-779

Biotin interference on immunoassay methods: Sporadic cases or hidden epidemic?

Author keywords

[No Author keywords available]

Indexed keywords

BIOTIN; C PEPTIDE; FOLLITROPIN; HYDROCORTISONE; LIOTHYRONINE; LUTEINIZING HORMONE; PARATHYROID HORMONE; STREPTAVIDIN; THYROTROPIN; VITAMIN D;

EID: 85019075646     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/cclm-2017-0070     Document Type: Review
Times cited : (21)

References (17)
  • 1
    • 25144458776 scopus 로고    scopus 로고
    • Interferences in immunoassay
    • Tate J, Ward G. Interferences in immunoassay. Clin Rev Biochem 2004;25:105-20.
    • (2004) Clin Rev Biochem , vol.25 , pp. 105-120
    • Tate, J.1    Ward, G.2
  • 2
    • 33744786784 scopus 로고    scopus 로고
    • Errors in clinical laboratories or errors in laboratory medicine?
    • Plebani M. Errors in clinical laboratories or errors in laboratory medicine? Clin Chem Lab Med 2006;44:750-9.
    • (2006) Clin Chem Lab Med , vol.44 , pp. 750-759
    • Plebani, M.1
  • 3
    • 84855176252 scopus 로고    scopus 로고
    • Analytical error and interference in immunoassay: Minimizing risk
    • Sturgeon C, Vijoen A. Analytical error and interference in immunoassay: minimizing risk. Ann Clin Biochem 2011;48:418-32.
    • (2011) Ann Clin Biochem , vol.48 , pp. 418-432
    • Sturgeon, C.1    Vijoen, A.2
  • 5
    • 8044257702 scopus 로고    scopus 로고
    • Acute effects of amiodarone administration on thyroid function in patients with cardiac arrhythmia
    • Iervasi G, Clerico A, Bonini R, Manfredi C, Berti S, Ravani M, et al. Acute effects of amiodarone administration on thyroid function in patients with cardiac arrhythmia. J Clin Endocrinol Metab 1997;82:275-80.
    • (1997) J Clin Endocrinol Metab , vol.82 , pp. 275-280
    • Iervasi, G.1    Clerico, A.2    Bonini, R.3    Manfredi, C.4    Berti, S.5    Ravani, M.6
  • 6
    • 0014775914 scopus 로고
    • Long-term thiazide therapy in essential hypertension. Evidence for persistent alteration in plasma volume and renin activity
    • Tarazi RC, Dustan HP, Frohlic ED. Long-term thiazide therapy in essential hypertension. Evidence for persistent alteration in plasma volume and renin activity. Circulation 1970;41:709-17.
    • (1970) Circulation , vol.41 , pp. 709-717
    • Tarazi, R.C.1    Dustan, H.P.2    Frohlic, E.D.3
  • 7
    • 0031464197 scopus 로고    scopus 로고
    • Hemostatic abnormalities associated with cancer and its therapy
    • Glassman AB. Hemostatic abnormalities associated with cancer and its therapy. Ann Clin Lab Sci 1997;27:391-5.
    • (1997) Ann Clin Lab Sci , vol.27 , pp. 391-395
    • Glassman, A.B.1
  • 8
    • 68149089064 scopus 로고    scopus 로고
    • Interference testing
    • Dimeski G. Interference testing. Clin Biochem Rev 2008;29(suppl 1):S43-8.
    • (2008) Clin Biochem Rev , vol.29 , pp. S43-S48
    • Dimeski, G.1
  • 9
    • 0025856887 scopus 로고
    • The biotin-(strept)avidin system: Principles and applications in biotechnology
    • Diamandis EP, Christopoulos TK. The biotin-(strept)avidin system: principles and applications in biotechnology. Clin Chem 1991;37:625-36.
    • (1991) Clin Chem , vol.37 , pp. 625-636
    • Diamandis, E.P.1    Christopoulos, T.K.2
  • 11
    • 85019154885 scopus 로고    scopus 로고
    • False biochemical diagnosis of hyperthyroidism in streptavidin-biotin-based immunoassays: The problem of biotin intake and related interferences
    • Piketty M-L, Polak M, Flechtner I, Gonzales-Briceño L, Souberbielle J-C. False biochemical diagnosis of hyperthyroidism in streptavidin-biotin-based immunoassays: the problem of biotin intake and related interferences. Clin Chem Lab Med 2017;55:780-8.
    • Clin Chem Lab Med , vol.2017 , Issue.55 , pp. 780-788
    • Piketty, M.-L.1    Polak, M.2    Flechtner, I.3    Gonzales-Briceño, L.4    Souberbielle, J.-C.5
  • 14
    • 85019066648 scopus 로고    scopus 로고
    • High-dose biotin therapy leading to false biochemical endocrine profiles: Validation of a simple method to overcome biotin interference
    • Piketty M-L, Prie D, Sedel F, Bernard D, Hercend C, Chanson P, et al. High-dose biotin therapy leading to false biochemical endocrine profiles: validation of a simple method to overcome biotin interference. Clin Chem Lab Med 2017;55:817-25.
    • Clin Chem Lab Med , vol.2017 , Issue.55 , pp. 817-825
    • Piketty, M.-L.1    Prie, D.2    Sedel, F.3    Bernard, D.4    Hercend, C.5    Chanson, P.6
  • 15
    • 84873679672 scopus 로고    scopus 로고
    • Biotin-responsive basal ganglia disease revisited: Clinical, radiologic, and genetic findings
    • Tabarki B, Al-Shafi S, Al-Shahwan S, Azmat Z, Al-Hashem A, Al-Adwani N, et al. Biotin-responsive basal ganglia disease revisited: clinical, radiologic, and genetic findings. Neurology 2013;80:261-7.
    • (2013) Neurology , vol.80 , pp. 261-267
    • Tabarki, B.1    Al-Shafi, S.2    Al-Shahwan, S.3    Azmat, Z.4    Al-Hashem, A.5    Al-Adwani, N.6
  • 17
    • 85019075239 scopus 로고    scopus 로고
    • A simple method to detect biotin interference on immunoassays
    • Lam L, Kyle CV. A simple method to detect biotin interference on immunoassays. Clin Chem Lab Med 2017;55:e104-6.
    • (2017) Clin Chem Lab Med , vol.55 , pp. e104-e106
    • Lam, L.1    Kyle, C.V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.