메뉴 건너뛰기




Volumn 32, Issue 2, 2018, Pages

Serum free light chain quantitative assays: Dilemma of a biomarker

Author keywords

comparative study; free light chains; multiple myeloma

Indexed keywords

BIOLOGICAL MARKER; IMMUNOGLOBULIN LIGHT CHAIN; TUMOR MARKER;

EID: 85018296977     PISSN: 08878013     EISSN: 10982825     Source Type: Journal    
DOI: 10.1002/jcla.22243     Document Type: Article
Times cited : (19)

References (34)
  • 2
    • 84993661399 scopus 로고    scopus 로고
    • Serum free light-chain assay for the detection and monitoring of multiple myeloma and related conditions
    • Tosi P, Tomassetti S, Merli A, Polli V. Serum free light-chain assay for the detection and monitoring of multiple myeloma and related conditions. Ther Adv Hematol. 2013;4:37-41.
    • (2013) Ther Adv Hematol , vol.4 , pp. 37-41
    • Tosi, P.1    Tomassetti, S.2    Merli, A.3    Polli, V.4
  • 4
    • 84864570434 scopus 로고    scopus 로고
    • Darwinian evolution and tiding clones in multiple myeloma
    • Bahlis NJ. Darwinian evolution and tiding clones in multiple myeloma. Blood. 2012;120:927-928.
    • (2012) Blood , vol.120 , pp. 927-928
    • Bahlis, N.J.1
  • 5
    • 70349195919 scopus 로고    scopus 로고
    • UK Myeloma Forum (UKMF) and Nordic Myeloma Study Group (NMSG): guidelines for the investigation of newly detected M-proteins and the management of monoclonal gammopathy of undetermined significance (MGUS)
    • Bird J, Behrens J, Westin J, et al. UK Myeloma Forum (UKMF) and Nordic Myeloma Study Group (NMSG): guidelines for the investigation of newly detected M-proteins and the management of monoclonal gammopathy of undetermined significance (MGUS). Br J Haematol. 2009;147:22-42.
    • (2009) Br J Haematol , vol.147 , pp. 22-42
    • Bird, J.1    Behrens, J.2    Westin, J.3
  • 7
    • 79958846304 scopus 로고    scopus 로고
    • Guidelines for the diagnosis and management of multiple myeloma 2011
    • Bird JM, Owen RG, D'sa S, et al. Guidelines for the diagnosis and management of multiple myeloma 2011. Br J Haematol. 2011;154:32-75.
    • (2011) Br J Haematol , vol.154 , pp. 32-75
    • Bird, J.M.1    Owen, R.G.2    D'sa, S.3
  • 8
    • 79956001465 scopus 로고    scopus 로고
    • Consensus recommendations for standard investigative workup: report of the International Myeloma Workshop Consensus Panel 3
    • Dimopoulos M, Kyle R, Fermand JP, et al. Consensus recommendations for standard investigative workup: report of the International Myeloma Workshop Consensus Panel 3. Blood. 2011;117:4701-4705.
    • (2011) Blood , vol.117 , pp. 4701-4705
    • Dimopoulos, M.1    Kyle, R.2    Fermand, J.P.3
  • 9
    • 60149096306 scopus 로고    scopus 로고
    • International Myeloma Working Group guidelines for serum-free light chain analysis in multiple myeloma and related disorders
    • Dispenzieri A, Kyle R, Merlini G, et al. International Myeloma Working Group guidelines for serum-free light chain analysis in multiple myeloma and related disorders. Leukemia. 2009;23:215-224.
    • (2009) Leukemia , vol.23 , pp. 215-224
    • Dispenzieri, A.1    Kyle, R.2    Merlini, G.3
  • 10
    • 84899915546 scopus 로고    scopus 로고
    • International Myeloma Working Group recommendations for global myeloma care
    • Ludwig H, Miguel JS, Dimopoulos MA, et al. International Myeloma Working Group recommendations for global myeloma care. Leukemia. 2014;28:981-992.
    • (2014) Leukemia , vol.28 , pp. 981-992
    • Ludwig, H.1    Miguel, J.S.2    Dimopoulos, M.A.3
  • 11
    • 84908604358 scopus 로고    scopus 로고
    • International Myeloma Working Group updated criteria for the diagnosis of multiple myeloma
    • Rajkumar SV, Dimopoulos MA, Palumbo A, et al. International Myeloma Working Group updated criteria for the diagnosis of multiple myeloma. Lancet Oncol. 2014;15:e538-e548.
    • (2014) Lancet Oncol , vol.15 , pp. e538-e548
    • Rajkumar, S.V.1    Dimopoulos, M.A.2    Palumbo, A.3
  • 12
    • 84880155994 scopus 로고    scopus 로고
    • Polyclonal free light chains: a biomarker of inflammatory disease or treatment target?
    • Brebner JA, Stockley RA. Polyclonal free light chains: a biomarker of inflammatory disease or treatment target? F1000 Med Rep. 2013;5:4.
    • (2013) F1000 Med Rep , vol.5 , pp. 4
    • Brebner, J.A.1    Stockley, R.A.2
  • 13
    • 84889246846 scopus 로고    scopus 로고
    • Rationale and prospects of serum immunoglobulin free light chain (FLC) determination in chronic inflammatory disease
    • Basile U, Mussap M. Rationale and prospects of serum immunoglobulin free light chain (FLC) determination in chronic inflammatory disease. Biochim Clin. 2013;37:357-364.
    • (2013) Biochim Clin , vol.37 , pp. 357-364
    • Basile, U.1    Mussap, M.2
  • 15
    • 84969799156 scopus 로고    scopus 로고
    • Is accuracy of serum free light chain measurement achievable?
    • Jacobs JF, Tate JR, Merlini G. Is accuracy of serum free light chain measurement achievable? Clin Chem Lab Med. 2016;54:1021-1030.
    • (2016) Clin Chem Lab Med , vol.54 , pp. 1021-1030
    • Jacobs, J.F.1    Tate, J.R.2    Merlini, G.3
  • 16
    • 77956480703 scopus 로고    scopus 로고
    • Quantitative serum free light chain assay-analytical issues
    • Tate J, Bazeley S, Sykes S, Mollee P. Quantitative serum free light chain assay-analytical issues. Clin Biochem Rev. 2009;30:131-140.
    • (2009) Clin Biochem Rev , vol.30 , pp. 131-140
    • Tate, J.1    Bazeley, S.2    Sykes, S.3    Mollee, P.4
  • 18
    • 79960619104 scopus 로고    scopus 로고
    • Effect of sample dilution on serum free light chain concentration by immunonephelometric assay
    • Vercammen M, Meirlaen P, Broodtaerts L, Broek IV, Bossuyt X. Effect of sample dilution on serum free light chain concentration by immunonephelometric assay. Clin Chim Acta. 2011;412:1798-1804.
    • (2011) Clin Chim Acta , vol.412 , pp. 1798-1804
    • Vercammen, M.1    Meirlaen, P.2    Broodtaerts, L.3    Broek, I.V.4    Bossuyt, X.5
  • 19
    • 84969780624 scopus 로고    scopus 로고
    • Analytical issues of serum free light chain assays and the relative performance of polyclonal and monoclonal based reagents
    • Carr-Smith HD, Jenner EL, Evans JA, Harding SJ. Analytical issues of serum free light chain assays and the relative performance of polyclonal and monoclonal based reagents. Clin Chem Lab Med. 2016;54:997-1003.
    • (2016) Clin Chem Lab Med , vol.54 , pp. 997-1003
    • Carr-Smith, H.D.1    Jenner, E.L.2    Evans, J.A.3    Harding, S.J.4
  • 20
    • 80051727075 scopus 로고    scopus 로고
    • N Latex FLC—new monoclonal high-performance assays for the determination of free light chain kappa and lambda
    • Te Velthuis H, Knop I, Stam P, et al. N Latex FLC—new monoclonal high-performance assays for the determination of free light chain kappa and lambda. Clin Chem Lab Med. 2011;49:1323-1332.
    • (2011) Clin Chem Lab Med , vol.49 , pp. 1323-1332
    • Te Velthuis, H.1    Knop, I.2    Stam, P.3
  • 21
    • 84879427112 scopus 로고    scopus 로고
    • A multicentre study comparing two methods for serum free light chain analysis
    • Lock RJ, Saleem R, Roberts EG, et al. A multicentre study comparing two methods for serum free light chain analysis. Ann Clin Biochem. 2013;50(Pt 3):255-261.
    • (2013) Ann Clin Biochem , vol.50 , pp. 255-261
    • Lock, R.J.1    Saleem, R.2    Roberts, E.G.3
  • 22
    • 84860478665 scopus 로고    scopus 로고
    • Clinical comparison of new monoclonal antibody-based nephelometric assays for free light chain kappa and lambda to polyclonal antibody-based assays and immunofixation electrophoresis
    • Hoedemakers RM, Pruijt JF, Hol S, et al. Clinical comparison of new monoclonal antibody-based nephelometric assays for free light chain kappa and lambda to polyclonal antibody-based assays and immunofixation electrophoresis. Clin Chem Lab Med. 2011;50:489-495.
    • (2011) Clin Chem Lab Med , vol.50 , pp. 489-495
    • Hoedemakers, R.M.1    Pruijt, J.F.2    Hol, S.3
  • 23
    • 84867149040 scopus 로고    scopus 로고
    • Evaluation of the N Latex FLC free light chain assay on the Siemens BN analyser: precision, agreement, linearity and variation between reagent lots
    • Pretorius CJ, Klingberg S, Tate J, Wilgen U, Ungerer JP. Evaluation of the N Latex FLC free light chain assay on the Siemens BN analyser: precision, agreement, linearity and variation between reagent lots. Ann Clin Biochem. 2012;49:450-455.
    • (2012) Ann Clin Biochem , vol.49 , pp. 450-455
    • Pretorius, C.J.1    Klingberg, S.2    Tate, J.3    Wilgen, U.4    Ungerer, J.P.5
  • 24
    • 85012912741 scopus 로고    scopus 로고
    • Development of a rapid and quantitative lateral flow assay for the simultaneous measurement of serum κ and λ immunoglobulin free light chains (FLC): inception of a new near-patient FLC screening tool
    • Campbell JP, Heaney JL, Shemar M, et al. Development of a rapid and quantitative lateral flow assay for the simultaneous measurement of serum κ and λ immunoglobulin free light chains (FLC): inception of a new near-patient FLC screening tool. Clin Chem Lab Med. 2017;55:424-434.
    • (2017) Clin Chem Lab Med , vol.55 , pp. 424-434
    • Campbell, J.P.1    Heaney, J.L.2    Shemar, M.3
  • 25
    • 84889264886 scopus 로고    scopus 로고
    • Towards improved measurement of serum free light chains: clinical and laboratory issues
    • Tate J, Mollee P. Towards improved measurement of serum free light chains: clinical and laboratory issues. Biochim Clin. 2013;37:395-404.
    • (2013) Biochim Clin , vol.37 , pp. 395-404
    • Tate, J.1    Mollee, P.2
  • 26
    • 84995917601 scopus 로고    scopus 로고
    • International Myeloma Working Group consensus criteria for response and minimal residual disease assessment in multiple myeloma
    • Kumar S, Paiva B, Anderson KC, et al. International Myeloma Working Group consensus criteria for response and minimal residual disease assessment in multiple myeloma. Lancet Oncol. 2016;17:e328-e346.
    • (2016) Lancet Oncol , vol.17 , pp. e328-e346
    • Kumar, S.1    Paiva, B.2    Anderson, K.C.3
  • 29
    • 84982106573 scopus 로고    scopus 로고
    • Comparison of free light chain assays: Freelite and N latex in diagnosis, monitoring, and predicting survival in light chain amyloidosis
    • Mahmood S, Wassef NL, Salter SJ, et al. Comparison of free light chain assays: Freelite and N latex in diagnosis, monitoring, and predicting survival in light chain amyloidosis. Am J Clin Pathol. 2016;146:78-85.
    • (2016) Am J Clin Pathol , vol.146 , pp. 78-85
    • Mahmood, S.1    Wassef, N.L.2    Salter, S.J.3
  • 30
    • 84969804415 scopus 로고    scopus 로고
    • Comparison of Freelite™ and N Latex serum free light chain assays in subjects with end stage kidney disease on haemodialysis
    • Kennard A, Hawley C, Tate J, et al. Comparison of Freelite™ and N Latex serum free light chain assays in subjects with end stage kidney disease on haemodialysis. Clin Chem Lab Med. 2016;54:1045-1052.
    • (2016) Clin Chem Lab Med , vol.54 , pp. 1045-1052
    • Kennard, A.1    Hawley, C.2    Tate, J.3
  • 31
    • 84930428423 scopus 로고    scopus 로고
    • Polyclonal versus monoclonal immunoglobulin-free light chains quantification
    • Di Noto G, Cimpoies E, Dossi A, et al. Polyclonal versus monoclonal immunoglobulin-free light chains quantification. Ann Clin Biochem. 2015;52(Pt 3):327-336.
    • (2015) Ann Clin Biochem , vol.52 , pp. 327-336
    • Di Noto, G.1    Cimpoies, E.2    Dossi, A.3
  • 32
    • 0036720993 scopus 로고    scopus 로고
    • Serum reference intervals and diagnostic ranges for free kappa and free lambda immunoglobulin light chains: relative sensitivity for detection of monoclonal light chains
    • Katzmann JA, Clark RJ, Abraham RS, et al. Serum reference intervals and diagnostic ranges for free kappa and free lambda immunoglobulin light chains: relative sensitivity for detection of monoclonal light chains. Clin Chem. 2002;48:1437-1444.
    • (2002) Clin Chem , vol.48 , pp. 1437-1444
    • Katzmann, J.A.1    Clark, R.J.2    Abraham, R.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.