메뉴 건너뛰기




Volumn 356, Issue , 2017, Pages

Exposure to low dose computed tomography for lung cancer screening and risk of cancer: Secondary analysis of trial data and risk-benefit analysis

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CANCER RISK; CANCER SCREENING; COHORT ANALYSIS; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DOSIMETRY; FEMALE; HUMAN; ITALY; LUNG CANCER; MALE; OBSERVATIONAL STUDY; POSITRON EMISSION TOMOGRAPHY; RADIATION DOSE; RADIATION EXPOSURE; RETROSPECTIVE STUDY; RISK BENEFIT ANALYSIS; SMOKING; ADVERSE EFFECTS; EARLY CANCER DIAGNOSIS; INCIDENCE; LUNG NEOPLASMS; MASS SCREENING; MIDDLE AGED; NEOPLASMS, RADIATION-INDUCED; PROCEDURES; RISK ASSESSMENT; RISK FACTOR; X-RAY COMPUTED TOMOGRAPHY;

EID: 85012257334     PISSN: 09598146     EISSN: 17561833     Source Type: Journal    
DOI: 10.1136/bmj.j347     Document Type: Article
Times cited : (208)

References (38)
  • 2
    • 79961108629 scopus 로고    scopus 로고
    • Reduced lung-cancer mortality with low-dose computed tomographic screening
    • National Lung Screening Trial Research Team
    • Aberle DR, Adams AM, Berg CD, et al. National Lung Screening Trial Research Team. Reduced lung-cancer mortality with low-dose computed tomographic screening. N Engl J Med 2011;365:395-409. doi:10.1056/NEJMoa1102873.
    • (2011) N Engl J Med , vol.365 , pp. 395-409
    • Aberle, D.R.1    Adams, A.M.2    Berg, C.D.3
  • 5
    • 84864331065 scopus 로고    scopus 로고
    • Radiation risks of medical imaging: Separating fact from fantasy
    • Hendee WR, OConnor MK. Radiation risks of medical imaging: separating fact from fantasy. Radiology 2012;264:312-21. doi:10.1148/radiol.12112678.
    • (2012) Radiology , vol.264 , pp. 312-321
    • Hendee, W.R.1    Oconnor, M.K.2
  • 6
    • 84867908988 scopus 로고    scopus 로고
    • Cancer risks from CT scans: Now we have data what next?
    • Brenner DJ, Hall EJ. Cancer risks from CT scans: now we have data, what next?Radiology 2012;265:330-1. doi:10.1148/radiol.12121248.
    • (2012) Radiology , vol.265 , pp. 330-331
    • Brenner, D.J.1    Hall, E.J.2
  • 7
    • 84914182948 scopus 로고    scopus 로고
    • Estimating risk of low radiation doses-A critical review of the BEIR VII report and its use of the linear no-Threshold (LNT) hypothesis
    • Calabrese EJ, OConnor MK. Estimating risk of low radiation doses-A critical review of the BEIR VII report and its use of the linear no-Threshold (LNT) hypothesis. Radiat Res 2014;182:463-74. doi:10.1667/RR13829.1.
    • (2014) Radiat Res , vol.182 , pp. 463-474
    • Calabrese, E.J.1    Oconnor, M.K.2
  • 8
    • 2142695134 scopus 로고    scopus 로고
    • Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer
    • Brenner DJ. Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer. Radiology 2004;231:440-5. doi:10.1148/radiol.2312030880.
    • (2004) Radiology , vol.231 , pp. 440-445
    • Brenner, D.J.1
  • 9
    • 84896740875 scopus 로고    scopus 로고
    • Radiation risks in lung cancer screening programs: A comparison with nuclear industry workers and atomic bomb survivors
    • McCunney RJ, Li J. Radiation risks in lung cancer screening programs: A comparison with nuclear industry workers and atomic bomb survivors. Chest 2014;145:618-24. doi:10.1378/chest.13-1420.
    • (2014) Chest , vol.145 , pp. 618-624
    • McCunney, R.J.1    Li, J.2
  • 10
    • 34548008355 scopus 로고    scopus 로고
    • Role of positron emission tomography scanning in the management of lung nodules detected at baseline computed tomography screening
    • 959-65, discussion
    • Veronesi G, Bellomi M, Veronesi U, et al. Role of positron emission tomography scanning in the management of lung nodules detected at baseline computed tomography screening. Ann Thorac Surg 2007;84: 959-65, discussion 965-6. doi:10.1016/j.athoracsur.2007.04.058.
    • (2007) Ann Thorac Surg , vol.84 , pp. 965-966
    • Veronesi, G.1    Bellomi, M.2    Veronesi, U.3
  • 11
    • 43549126325 scopus 로고    scopus 로고
    • Lung cancer screening with low-dose computed tomography: A non-invasive diagnostic protocol for baseline lung nodules
    • Veronesi G, Bellomi M, Mulshine JL, et al. Lung cancer screening with low-dose computed tomography: A non-invasive diagnostic protocol for baseline lung nodules. Lung Cancer 2008;61:340-9. doi:10.1016/j. lungcan.2008.01.001.
    • (2008) Lung Cancer , vol.61 , pp. 340-349
    • Veronesi, G.1    Bellomi, M.2    Mulshine, J.L.3
  • 14
    • 40949104442 scopus 로고    scopus 로고
    • The 2007 recommendations of the international commission on Radiological Protection. ICRP publication 103
    • International Commission on Radiological Protection
    • International Commission on Radiological Protection. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP 2007;37:1-332.
    • (2007) Ann ICRP , vol.37 , pp. 1-332
  • 15
    • 62349083799 scopus 로고    scopus 로고
    • Icrp . Radiation dose to patients from radiopharmaceuticals. Addendum 3 to ICRP Publication 53. ICRP Publication 106. Approved by the Commission in October 2007
    • Icrp . Radiation dose to patients from radiopharmaceuticals. Addendum 3 to ICRP Publication 53. ICRP Publication 106. Approved by the Commission in October 2007. Ann ICRP 2008;38:1-197.
    • (2008) Ann ICRP , vol.38 , pp. 1-197
  • 16
    • 47249166093 scopus 로고    scopus 로고
    • Effective doses in radiology and diagnostic nuclear medicine: A catalog
    • Mettler FA Jr, , Huda W, Yoshizumi TT, Mahesh M. Effective doses in radiology and diagnostic nuclear medicine: A catalog. Radiology 2008;248:254-63. doi:10.1148/radiol.2481071451.
    • (2008) Radiology , vol.248 , pp. 254-263
    • Mettler, F.A.1    Huda, W.2    Yoshizumi, T.T.3    Mahesh, M.4
  • 17
    • 84901806922 scopus 로고    scopus 로고
    • A survey of organ equivalent and effective doses from diagnostic radiology procedures
    • Osei EK, Darko J. A survey of organ equivalent and effective doses from diagnostic radiology procedures. ISRN Radiol 2012;2013:204346.
    • (2013) ISRN Radiol 2012 , pp. 204346
    • Osei, E.K.1    Darko, J.2
  • 18
    • 0003710075 scopus 로고    scopus 로고
    • United Nations Scientific Committee on the Effects of Atomic Radiation. UNSCEAR 2008 report to the General Assembly. United Nations
    • United Nations Scientific Committee on the Effects of Atomic Radiation. UNSCEAR 2008 report to the General Assembly. Sources and effects of ionizing radiation. United Nations, 2010.
    • (2010) Sources and Effects of Ionizing Radiation
  • 20
    • 24944525792 scopus 로고    scopus 로고
    • Dose-effect relationship and estimation of the carcinogenic effects of low doses of ionizing radiation: The joint report of the Académie des Sciences (Paris) and of the Académie Nationale de Médecine
    • Tubiana M. Dose-effect relationship and estimation of the carcinogenic effects of low doses of ionizing radiation: The joint report of the Académie des Sciences (Paris) and of the Académie Nationale de Médecine. Int J Radiat Oncol Biol Phys 2005;63:317-9. doi:10.1016/j.ijrobp.2005.06.013.
    • (2005) Int J Radiat Oncol Biol Phys , vol.63 , pp. 317-319
    • Tubiana, M.1
  • 21
    • 84900563372 scopus 로고    scopus 로고
    • Advances in radiation biology: Effect on nuclear medicine
    • Brooks AL, Dauer LT. Advances in radiation biology: effect on nuclear medicine. Semin Nucl Med 2014;44:179-86. doi: 10.1053/j. semnuclmed.2014.03.004.
    • (2014) Semin Nucl Med , vol.44 , pp. 179-186
    • Brooks, A.L.1    Dauer, L.T.2
  • 22
    • 84876893487 scopus 로고    scopus 로고
    • Policy statement of the international organization for medical physics
    • International Organization for Medical Physics. International organization for medical physics
    • Hendee WR. International Organization for Medical Physics. International organization for medical physics. Policy statement of the international organization for medical physics. Radiology 2013;267:326-7. doi:10.1148/radiol.13130567.
    • (2013) Radiology , vol.267 , pp. 326-327
    • Hendee, W.R.1
  • 25
    • 48249085792 scopus 로고    scopus 로고
    • Low-dose radiation risk extrapolation fallacy associated with the linear-no-Threshold model
    • Scott BR. Low-dose radiation risk extrapolation fallacy associated with the linear-no-Threshold model. Hum Exp Toxicol 2008;27:163-8. doi:10.1177/0960327107083410.
    • (2008) Hum Exp Toxicol , vol.27 , pp. 163-168
    • Scott, B.R.1
  • 26
    • 77950600954 scopus 로고    scopus 로고
    • How effective is effective dose as a predictor of radiation risk?
    • McCollough CH, Christner JA, Kofler JM. How effective is effective dose as a predictor of radiation risk?AJR Am J Roentgenol 2010;194:890-6. doi:10.2214/AJR.09.4179.
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 890-896
    • McCollough, C.H.1    Christner, J.A.2    Kofler, J.M.3
  • 27
    • 84966929745 scopus 로고    scopus 로고
    • Use of effective dose
    • Harrison JD, Balonov M, Martin CJ, et al. Use of effective dose. Ann ICRP 2016;45(Suppl):215-24. doi:10.1177/0146645316634566.
    • (2016) Ann ICRP , vol.45 , pp. 215-224
    • Harrison, J.D.1    Balonov, M.2    Martin, C.J.3
  • 29
    • 80054952663 scopus 로고    scopus 로고
    • Estimated radiation dose associated with low-dose chest CT of average-size participants in the National Lung Screening Trial
    • Larke FJ, Kruger RL, Cagnon CH, et al. Estimated radiation dose associated with low-dose chest CT of average-size participants in the National Lung Screening Trial. AJR Am J Roentgenol 2011;197:1165-9. doi:10.2214/AJR.11.6533.
    • (2011) AJR Am J Roentgenol , vol.197 , pp. 1165-1169
    • Larke, F.J.1    Kruger, R.L.2    Cagnon, C.H.3
  • 30
    • 84864853041 scopus 로고    scopus 로고
    • Dose exposure in the ITALUNG trial of lung cancer screening with low-dose CT
    • Mascalchi M, Mazzoni LN, Falchini M, et al. Dose exposure in the ITALUNG trial of lung cancer screening with low-dose CT. Br J Radiol 2012;85:1134-9. doi:10.1259/bjr/20711289.
    • (2012) Br J Radiol , vol.85 , pp. 1134-1139
    • Mascalchi, M.1    Mazzoni, L.N.2    Falchini, M.3
  • 31
    • 81555210887 scopus 로고    scopus 로고
    • Lung cancer risk prediction to select smokers for screening CT-A model based on the Italian COSMOS trial
    • Maisonneuve P, Bagnardi V, Bellomi M, et al. Lung cancer risk prediction to select smokers for screening CT-A model based on the Italian COSMOS trial. Cancer Prev Res (Phila) 2011;4:1778-89. doi:10.1158/1940-6207.CAPR-11-0026.
    • (2011) Cancer Prev Res (Phila) , vol.4 , pp. 1778-1789
    • Maisonneuve, P.1    Bagnardi, V.2    Bellomi, M.3
  • 32
    • 84901710470 scopus 로고    scopus 로고
    • Screening for lung cancer using low dose computed tomography
    • Tammemagi MC, Lam S. Screening for lung cancer using low dose computed tomography. BMJ 2014;348:g2253. doi:10.1136/bmj.g2253.
    • (2014) BMJ , vol.348 , pp. g2253
    • Tammemagi, M.C.1    Lam, S.2
  • 33
    • 84863666413 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: A pilot study
    • Yamada Y, Jinzaki M, Tanami Y, et al. Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: A pilot study. Invest Radiol 2012;47:482-9. doi:10.1097/RLI.0b013e3182562a89.
    • (2012) Invest Radiol , vol.47 , pp. 482-489
    • Yamada, Y.1    Jinzaki, M.2    Tanami, Y.3
  • 34
    • 84896338008 scopus 로고    scopus 로고
    • Radiation dose reduction for CT lung cancer screening using ASIR and MBIR: A phantom study
    • Mathieu KB, Ai H, Fox PS, et al. Radiation dose reduction for CT lung cancer screening using ASIR and MBIR: A phantom study. J Appl Clin Med Phys 2014;15:4515.
    • (2014) J Appl Clin Med Phys , vol.15 , pp. 4515
    • Mathieu, K.B.1    Ai, H.2    Fox, P.S.3
  • 35
    • 84944351349 scopus 로고    scopus 로고
    • Achievable dose reduction using iterative reconstruction for chest computed tomography: A systematic review
    • den Harder AM, Willemink MJ, de Ruiter QMB, et al. Achievable dose reduction using iterative reconstruction for chest computed tomography: A systematic review. Eur J Radiol 2015;84:2307-13. doi:10.1016/j.ejrad.2015.07.011.
    • (2015) Eur J Radiol , vol.84 , pp. 2307-2313
    • Den Harder, A.M.1    Willemink, M.J.2    De Ruiter, Q.M.B.3
  • 36
    • 84931003800 scopus 로고    scopus 로고
    • Ultra-low-dose CT with model-based iterative reconstruction (MBIR): Detection of ground-glass nodules in an anthropomorphic phantom study
    • Rampinelli C, Origgi D, Vecchi V, et al. Ultra-low-dose CT with model-based iterative reconstruction (MBIR): detection of ground-glass nodules in an anthropomorphic phantom study. Radiol Med 2015;120:611-7. doi:10.1007/s11547-015-0505-5.
    • (2015) Radiol Med , vol.120 , pp. 611-617
    • Rampinelli, C.1    Origgi, D.2    Vecchi, V.3
  • 37
    • 80053055764 scopus 로고    scopus 로고
    • Extrapulmonary malignancies detected at lung cancer screening
    • Rampinelli C, Preda L, Maniglio M, et al. Extrapulmonary malignancies detected at lung cancer screening. Radiology 2011;261:293-9. doi:10.1148/radiol.11102231.
    • (2011) Radiology , vol.261 , pp. 293-299
    • Rampinelli, C.1    Preda, L.2    Maniglio, M.3
  • 38
    • 34248682138 scopus 로고    scopus 로고
    • Neglectable benefit of searching for incidental findings in the Dutch-Belgian lung cancer screening trial (NELSON) using low-dose multidetector CT
    • NELSON study group
    • van de Wiel JC, Wang Y, Xu DM, et al. NELSON study group. Neglectable benefit of searching for incidental findings in the Dutch-Belgian lung cancer screening trial (NELSON) using low-dose multidetector CT. Eur Radiol 2007;17:1474-82. doi:10.1007/s00330-006-0532-7.
    • (2007) Eur Radiol , vol.17 , pp. 1474-1482
    • Van De Wiel, J.C.1    Wang, Y.2    Xu, D.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.