Performance Evaluation of Three Blood Glucose Monitoring Systems Using ISO 15197: 2013 Accuracy Criteria, Consensus and urveillance Error Grid Analyses, and Insulin Dosing Error Modeling in a Hospital Setting

Author keywords

accuracy; blood glucose monitoring system; consensus error grid; Contour Next; diabetes; glucose meter; insulin dosing error; surveillance error grid

Indexed keywords

ASCORBIC ACID; CARBOHYDRATE; HEXOKINASE; INSULIN; PARACETAMOL; GLUCOSE BLOOD LEVEL;

EID: 85009106626     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/1932296815609368     Document Type: Article
Times cited : (25)

References (15)
  • 1
    • 84871995815 scopus 로고    scopus 로고
    • American Diabetes Association, Standards of medical care in diabetes 2013
    • American Diabetes Association, Standards of medical care in diabetes-2013. Diabetes Care. 2013; 36 (suppl 1): S11.
    • (2013) Diabetes Care , vol.36 , pp. S11
  • 2
    • 85009075502 scopus 로고    scopus 로고
    • The accuracy and interferences in self-monitoring of blood glucose
    • Bode BW,. The accuracy and interferences in self-monitoring of blood glucose. US Endocr Dis Touch Brief. 2007: 4-6.
    • US Endocr Dis Touch Brief , vol.2007 , pp. 4-6
    • Bode, B.W.1
  • 3
    • 36148935891 scopus 로고    scopus 로고
    • Significant insulin dose errors may occur if blood glucose results are obtained from miscoded meters
    • Raine CH, Schrock LE, Edelman SV, et al. Significant insulin dose errors may occur if blood glucose results are obtained from miscoded meters. J Diabetes Sci Technol. 2007; 1 (2): 205-210.
    • (2007) J Diabetes Sci Technol , vol.1 , Issue.2 , pp. 205-210
    • Raine, C.H.1    Schrock, L.E.2    Edelman, S.V.3
  • 4
    • 0032511583 scopus 로고    scopus 로고
    • Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)
    • Turner RC, Holman RR, Cull CA, et al. Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). Lancet. 1998; 352 (9131): 837-853.
    • (1998) Lancet , vol.352 , Issue.9131 , pp. 837-853
    • Turner, R.C.1    Holman, R.R.2    Cull, C.A.3
  • 5
    • 26844577646 scopus 로고    scopus 로고
    • Strategies for improving glycemic control: Effective use of glucose monitoring
    • Davidson J., Strategies for improving glycemic control: effective use of glucose monitoring. Am J Med. 2005; 118 (suppl 9A): 27S-32S.
    • (2005) Am J Med , vol.118 , pp. 27S-32S
    • Davidson, J.1
  • 6
    • 0347133334 scopus 로고    scopus 로고
    • Poor control of risk factors for vascular disease among adults with previously diagnosed diabetes
    • Saydah SH, Fradkin J, Cowie CC., Poor control of risk factors for vascular disease among adults with previously diagnosed diabetes. JAMA. 2004; 291 (3): 335-342.
    • (2004) JAMA , vol.291 , Issue.3 , pp. 335-342
    • Saydah, S.H.1    Fradkin, J.2    Cowie, C.C.3
  • 8
    • 84873189111 scopus 로고    scopus 로고
    • Importance of blood glucose meter and carbohydrate estimation accuracy
    • Virdi NS, Mahoney JJ., Importance of blood glucose meter and carbohydrate estimation accuracy. J Diabetes Sci Technol. 2012; 6 (4): 921-926.
    • (2012) J Diabetes Sci Technol , vol.6 , Issue.4 , pp. 921-926
    • Virdi, N.S.1    Mahoney, J.J.2
  • 9
    • 77951733801 scopus 로고    scopus 로고
    • A review of standards and statistics used to describe blood glucose monitor performance
    • Krouwer JS, Cembrowski GS., A review of standards and statistics used to describe blood glucose monitor performance. J Diabetes Sci Technol. 2010; 4 (1): 75-83.
    • (2010) J Diabetes Sci Technol , vol.4 , Issue.1 , pp. 75-83
    • Krouwer, J.S.1    Cembrowski, G.S.2
  • 10
    • 0033855803 scopus 로고    scopus 로고
    • A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose
    • Parkes JL, Slatin SL, Pardo S, et al. A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. Diabetes Care. 2000; 23 (8): 1143-1148.
    • (2000) Diabetes Care , vol.23 , Issue.8 , pp. 1143-1148
    • Parkes, J.L.1    Slatin, S.L.2    Pardo, S.3
  • 12
    • 85009074838 scopus 로고    scopus 로고
    • A multi-center performance evaluation of a blood glucose monitoring system in 21 leading hospitals in Spain
    • [published online ahead of print 7, ]
    • Bedini JL, Wallace JF, Petruschke T, Pardo S,. A multi-center performance evaluation of a blood glucose monitoring system in 21 leading hospitals in Spain. [published online ahead of print 7, 2015 ]. J Diabetes Sci Technol.
    • (2015) J Diabetes Sci Technol
    • Bedini, J.L.1    Wallace, J.F.2    Petruschke, T.3    Pardo, S.4
  • 13
    • 84939426959 scopus 로고    scopus 로고
    • Accuracy evaluation of four blood glucose monitoring systems in unaltered blood samples in the low glycemic range and blood samples in the concentration range defined by ISO 15197
    • Freckmann G, Pleus S, Link M, et al. Accuracy evaluation of four blood glucose monitoring systems in unaltered blood samples in the low glycemic range and blood samples in the concentration range defined by ISO 15197. Diabetes Technol Ther. 2015; 17: 625-634.
    • (2015) Diabetes Technol Ther , vol.17 , pp. 625-634
    • Freckmann, G.1    Pleus, S.2    Link, M.3
  • 14
    • 84900550638 scopus 로고    scopus 로고
    • Accuracy evaluation of five blood glucose monitoring systems: The North American Comparator Trial
    • Halldorsdottir S, Warchal-Windham ME, Wallace JF, et al. Accuracy evaluation of five blood glucose monitoring systems: the North American Comparator Trial. J Diabetes Sci Technol. 2013; 7 (5): 1294-1304.
    • (2013) J Diabetes Sci Technol , vol.7 , Issue.5 , pp. 1294-1304
    • Halldorsdottir, S.1    Warchal-Windham, M.E.2    Wallace, J.F.3
  • 15
    • 84892649142 scopus 로고    scopus 로고
    • Evaluation of 12 blood glucose monitoring systems for self-testing: System accuracy and measurement reproducibility
    • Freckmann G, Baumstark A, Schmid C, et al. Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility. Diabetes Technol Ther. 2014; 16 (2): 113-122.
    • (2014) Diabetes Technol Ther , vol.16 , Issue.2 , pp. 113-122
    • Freckmann, G.1    Baumstark, A.2    Schmid, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.