메뉴 건너뛰기




Volumn 25, Issue 12, 2016, Pages 4199-4207

Minimally invasive cortical bone trajectory screws placement via pedicle or pedicle rib unit in the lower thoracic spine: a cadaveric and radiographic study

Author keywords

Cortical bone trajectory screws; Minimally invasive; Pedicle rib unit; Rescue failed screws; Thoracic pedicle screws

Indexed keywords

ARTICLE; BONE SCREW; CADAVER; CERVICAL SPINE RADIOGRAPHY; COMPUTER ASSISTED TOMOGRAPHY; CORTICAL BONE; FEMALE; HUMAN; IMAGE RECONSTRUCTION; MALE; MINIMALLY INVASIVE SURGERY; PEDICLE SCREW; PRIORITY JOURNAL; SURGICAL TECHNIQUE; THORACIC SPINE; THREE DIMENSIONAL IMAGING; ADULT; AGED; DIAGNOSTIC IMAGING; FEASIBILITY STUDY; MIDDLE AGED; ORTHOPEDIC SURGERY; PROCEDURES; SURGERY; THORACIC VERTEBRA; X-RAY COMPUTED TOMOGRAPHY;

EID: 84983375678     PISSN: 09406719     EISSN: 14320932     Source Type: Journal    
DOI: 10.1007/s00586-016-4730-y     Document Type: Article
Times cited : (11)

References (25)
  • 2
    • 84942081928 scopus 로고    scopus 로고
    • Cortical bone trajectory versus percutaneous pedicle screw in minimally invasive posterior lumbar fusion
    • Gonchar I, Kotani Y, Matsumoto Y (2014) Cortical bone trajectory versus percutaneous pedicle screw in minimally invasive posterior lumbar fusion. Spine J 14(11, Supplement):S114–S115. doi:10.1016/j.spinee.2014.08.286
    • (2014) Spine J , vol.14 , pp. S114-S115
    • Gonchar, I.1    Kotani, Y.2    Matsumoto, Y.3
  • 3
    • 84897667745 scopus 로고    scopus 로고
    • Novel placement of cortical bone trajectory screws in previously instrumented pedicles for adjacent-segment lumbar disease using CT image-guided navigation
    • PID: 24580010
    • Rodriguez A, Neal MT, Liu A, Somasundaram A, Hsu W, Branch CL Jr (2014) Novel placement of cortical bone trajectory screws in previously instrumented pedicles for adjacent-segment lumbar disease using CT image-guided navigation. Neurosurg Focus 36(3):E9. doi:10.3171/2014.1.focus13521
    • (2014) Neurosurg Focus , vol.36 , Issue.3 , pp. E9
    • Rodriguez, A.1    Neal, M.T.2    Liu, A.3    Somasundaram, A.4    Hsu, W.5    Branch, C.L.6
  • 4
    • 84958111465 scopus 로고    scopus 로고
    • Biomechanical evaluation of fixation strength among different sizes of pedicle screws using the cortical bone trajectory: what is the ideal screw size for optimal fixation?
    • Matsukawa K, Yato Y, Imabayashi H, Hosogane N, Abe Y, Asazuma T, Chiba K (2016) Biomechanical evaluation of fixation strength among different sizes of pedicle screws using the cortical bone trajectory: what is the ideal screw size for optimal fixation? Acta Neurochir (Wien) 158(3):465–471. doi:10.1007/s00701-016-2705-8
    • (2016) Acta Neurochir (Wien) , vol.158 , Issue.3 , pp. 465-471
    • Matsukawa, K.1    Yato, Y.2    Imabayashi, H.3    Hosogane, N.4    Abe, Y.5    Asazuma, T.6    Chiba, K.7
  • 5
    • 84958762293 scopus 로고    scopus 로고
    • Morphometric measurement of the lumbosacral spine for minimally invasive cortical bone trajectory implant using computed tomography
    • PID: 26342703
    • Zhang H, Ajiboye RM, Shamie AN, Wu Q, Chen Q, Chen W (2016) Morphometric measurement of the lumbosacral spine for minimally invasive cortical bone trajectory implant using computed tomography. Eur Spine J 25(3):870–876. doi:10.1007/s00586-015-4224-3
    • (2016) Eur Spine J , vol.25 , Issue.3 , pp. 870-876
    • Zhang, H.1    Ajiboye, R.M.2    Shamie, A.N.3    Wu, Q.4    Chen, Q.5    Chen, W.6
  • 6
    • 84954076747 scopus 로고    scopus 로고
    • Early complications after instrumentation of the lumbar spine using cortical bone trajectory technique
    • PID: 26482459
    • Patel SS, Cheng WK, Danisa OA (2016) Early complications after instrumentation of the lumbar spine using cortical bone trajectory technique. J Clin Neurosci 24:63–67. doi:10.1016/j.jocn.2015.07.018
    • (2016) J Clin Neurosci , vol.24 , pp. 63-67
    • Patel, S.S.1    Cheng, W.K.2    Danisa, O.A.3
  • 8
    • 80455158269 scopus 로고    scopus 로고
    • Thoracic pedicle morphometry in different body height population: a three-dimensional study using reformatted computed tomography
    • Zhuang Z, Zhuang Z, Chen Y, Han H, Cai S, Wang X (2011) Thoracic pedicle morphometry in different body height population: a three-dimensional study using reformatted computed tomography. Spine (Phila Pa 1976) 36(24):E1547–E1554. doi:10.1097/BRS.0b013e318210f063
    • (2011) Spine (Phila Pa 1976) , vol.36 , Issue.24 , pp. E1547-E1554
    • Zhuang, Z.1    Zhuang, Z.2    Chen, Y.3    Han, H.4    Cai, S.5    Wang, X.6
  • 9
    • 84881477180 scopus 로고    scopus 로고
    • Morphometric measurement of cortical bone trajectory for lumbar pedicle screw insertion using computed tomography
    • PID: 23429319
    • Matsukawa K, Yato Y, Nemoto O, Imabayashi H, Asazuma T, Nemoto K (2013) Morphometric measurement of cortical bone trajectory for lumbar pedicle screw insertion using computed tomography. J Spinal Disord Tech 26(6):E248–E253. doi:10.1097/BSD.0b013e318288ac39
    • (2013) J Spinal Disord Tech , vol.26 , Issue.6 , pp. E248-E253
    • Matsukawa, K.1    Yato, Y.2    Nemoto, O.3    Imabayashi, H.4    Asazuma, T.5    Nemoto, K.6
  • 10
    • 84942105402 scopus 로고    scopus 로고
    • Cortical bone trajectory for lumbar pedicle screw placement: a review of published reports
    • PID: 26311095
    • Phan K, Hogan J, Maharaj M, Mobbs RJ (2015) Cortical bone trajectory for lumbar pedicle screw placement: a review of published reports. Orthop Surg 7(3):213–221. doi:10.1111/os.12185
    • (2015) Orthop Surg , vol.7 , Issue.3 , pp. 213-221
    • Phan, K.1    Hogan, J.2    Maharaj, M.3    Mobbs, R.J.4
  • 11
    • 84935458017 scopus 로고    scopus 로고
    • Pedicle screw placement in the lumbar spine: effect of trajectory and screw design on acute biomechanical purchase
    • PID: 25679236
    • Wray S, Mimran R, Vadapalli S, Shetye SS, McGilvray KC, Puttlitz CM (2015) Pedicle screw placement in the lumbar spine: effect of trajectory and screw design on acute biomechanical purchase. J Neurosurg Spine 22(5):503–510. doi:10.3171/2014.10.spine14205
    • (2015) J Neurosurg Spine , vol.22 , Issue.5 , pp. 503-510
    • Wray, S.1    Mimran, R.2    Vadapalli, S.3    Shetye, S.S.4    McGilvray, K.C.5    Puttlitz, C.M.6
  • 13
    • 0036516051 scopus 로고    scopus 로고
    • Analysis of vertebral morphology in idiopathic scoliosis with use of magnetic resonance imaging and multiplanar reconstruction
    • PID: 11886904
    • Liljenqvist UR, Allkemper T, Hackenberg L, Link TM, Steinbeck J, Halm HF (2002) Analysis of vertebral morphology in idiopathic scoliosis with use of magnetic resonance imaging and multiplanar reconstruction. J Bone Joint Surg Am 84-a(3):359–368
    • (2002) J Bone Joint Surg Am , vol.84-a , Issue.3 , pp. 359-368
    • Liljenqvist, U.R.1    Allkemper, T.2    Hackenberg, L.3    Link, T.M.4    Steinbeck, J.5    Halm, H.F.6
  • 14
    • 0034665136 scopus 로고    scopus 로고
    • Pedicle morphology in thoracic adolescent idiopathic scoliosis: is pedicle fixation an anatomically viable technique?
    • O’Brien MF, Lenke LG, Mardjetko S, Lowe TG, Kong Y, Eck K, Smith D (2000) Pedicle morphology in thoracic adolescent idiopathic scoliosis: is pedicle fixation an anatomically viable technique? Spine (Phila Pa 1976) 25(18):2285–2293
    • (2000) Spine (Phila Pa 1976) , vol.25 , Issue.18 , pp. 2285-2293
    • O’Brien, M.F.1    Lenke, L.G.2    Mardjetko, S.3    Lowe, T.G.4    Kong, Y.5    Eck, K.6    Smith, D.7
  • 15
    • 0037112086 scopus 로고    scopus 로고
    • Pedicle morphometry in the upper thoracic spine: limits to safe screw placement in older patients
    • McLain RF, Ferrara L, Kabins M (2002) Pedicle morphometry in the upper thoracic spine: limits to safe screw placement in older patients. Spine (Phila Pa 1976) 27(22):2467–2471. doi:10.1097/01.brs.0000031265.42972.15
    • (2002) Spine (Phila Pa 1976) , vol.27 , Issue.22 , pp. 2467-2471
    • McLain, R.F.1    Ferrara, L.2    Kabins, M.3
  • 16
    • 33646831822 scopus 로고    scopus 로고
    • The role of the dorsal vertebral cortex in the stability of transpedicular screws. A biomechanical study in human cadaveric vertebrae
    • COI: 1:STN:280:DC%2BD283jslCnsg%3D%3D, PID: 16645123
    • Karataglis D, Kapetanos G, Lontos A, Christodoulou A, Christoforides J, Pournaras J (2006) The role of the dorsal vertebral cortex in the stability of transpedicular screws. A biomechanical study in human cadaveric vertebrae. J Bone Joint Surg Br 88(5):692–695. doi:10.1302/0301-620x.88b5.17422
    • (2006) J Bone Joint Surg Br , vol.88 , Issue.5 , pp. 692-695
    • Karataglis, D.1    Kapetanos, G.2    Lontos, A.3    Christodoulou, A.4    Christoforides, J.5    Pournaras, J.6
  • 17
    • 0035870882 scopus 로고    scopus 로고
    • Mapping the structural properties of the lumbosacral vertebral endplates
    • COI: 1:STN:280:DC%2BD3MvhtVShuw%3D%3D
    • Grant JP, Oxland TR, Dvorak MF (2001) Mapping the structural properties of the lumbosacral vertebral endplates. Spine (Phila Pa 1976) 26(8):889–896
    • (2001) Spine (Phila Pa 1976) , vol.26 , Issue.8 , pp. 889-896
    • Grant, J.P.1    Oxland, T.R.2    Dvorak, M.F.3
  • 18
    • 22544471268 scopus 로고    scopus 로고
    • Stiffness between different directions of transpedicular screws and vertebra
    • Wu SS, Yuan HA (1998) Stiffness between different directions of transpedicular screws and vertebra. Clin Biomech (Bristol, Avon) 13(1 Suppl 1):S1–S8
    • (1998) Clin Biomech (Bristol, Avon) , vol.13 , pp. S1-S8
    • Wu, S.S.1    Yuan, H.A.2
  • 19
    • 58249126122 scopus 로고    scopus 로고
    • Vertebral fractures usually affect the cranial endplate because it is thinner and supported by less-dense trabecular bone
    • PID: 19049912
    • Zhao FD, Pollintine P, Hole BD, Adams MA, Dolan P (2009) Vertebral fractures usually affect the cranial endplate because it is thinner and supported by less-dense trabecular bone. Bone 44(2):372–379. doi:10.1016/j.bone.2008.10.048
    • (2009) Bone , vol.44 , Issue.2 , pp. 372-379
    • Zhao, F.D.1    Pollintine, P.2    Hole, B.D.3    Adams, M.A.4    Dolan, P.5
  • 20
    • 84865860980 scopus 로고    scopus 로고
    • What is the best way to optimize thoracic kyphosis correction? A micro-CT and biomechanical analysis of pedicle morphology and screw failure
    • Lehman RA Jr, Helgeson MD, Dmitriev AE, Paik H, Bevevino AJ, Gaume R, Kang DG, Lenke LG (2012) What is the best way to optimize thoracic kyphosis correction? A micro-CT and biomechanical analysis of pedicle morphology and screw failure. Spine (Phila Pa 1976) 37(19):E1171–E1176. doi:10.1097/BRS.0b013e31825eb8fb
    • (2012) Spine (Phila Pa 1976) , vol.37 , Issue.19 , pp. E1171-E1176
    • Lehman, R.A.1    Helgeson, M.D.2    Dmitriev, A.E.3    Paik, H.4    Bevevino, A.J.5    Gaume, R.6    Kang, D.G.7    Lenke, L.G.8
  • 21
    • 0031418780 scopus 로고    scopus 로고
    • Regional variation in vertebral bone density and trabecular architecture are influenced by osteoarthritic change and osteoporosis
    • COI: 1:STN:280:DyaK1c%2Fhs1ynsw%3D%3D, (discussion 2401–2392)
    • Antonacci MD, Hanson DS, Leblanc A, Heggeness MH (1997) Regional variation in vertebral bone density and trabecular architecture are influenced by osteoarthritic change and osteoporosis. Spine (Phila Pa 1976) 22(20):2393–2401 (discussion 2401–2392)
    • (1997) Spine (Phila Pa 1976) , vol.22 , Issue.20 , pp. 2393-2401
    • Antonacci, M.D.1    Hanson, D.S.2    Leblanc, A.3    Heggeness, M.H.4
  • 22
    • 0035101506 scopus 로고    scopus 로고
    • Thoracic pedicle: surgical anatomic evaluation and relations
    • COI: 1:STN:280:DC%2BD3M3osFWqsg%3D%3D, PID: 11242273
    • Ugur HC, Attar A, Uz A, Tekdemir I, Egemen N, Genc Y (2001) Thoracic pedicle: surgical anatomic evaluation and relations. J Spinal Disord 14(1):39–45
    • (2001) J Spinal Disord , vol.14 , Issue.1 , pp. 39-45
    • Ugur, H.C.1    Attar, A.2    Uz, A.3    Tekdemir, I.4    Egemen, N.5    Genc, Y.6
  • 23
    • 2542464857 scopus 로고    scopus 로고
    • Morphometric study of the thoracic vertebral pedicle in an Indian population
    • Datir SP, Mitra SR (2004) Morphometric study of the thoracic vertebral pedicle in an Indian population. Spine (Phila Pa 1976) 29(11):1174–1181
    • (2004) Spine (Phila Pa 1976) , vol.29 , Issue.11 , pp. 1174-1181
    • Datir, S.P.1    Mitra, S.R.2
  • 24
    • 0028239639 scopus 로고
    • Morphometric study of the pedicles of thoracic and lumbar vertebrae in Koreans
    • COI: 1:STN:280:DyaK2czksFCmtQ%3D%3D
    • Kim NH, Lee HM, Chung IH, Kim HJ, Kim SJ (1994) Morphometric study of the pedicles of thoracic and lumbar vertebrae in Koreans. Spine (Phila Pa 1976) 19(12):1390–1394
    • (1994) Spine (Phila Pa 1976) , vol.19 , Issue.12 , pp. 1390-1394
    • Kim, N.H.1    Lee, H.M.2    Chung, I.H.3    Kim, H.J.4    Kim, S.J.5
  • 25
    • 33746104432 scopus 로고    scopus 로고
    • Computed tomographic morphometry of thoracic pedicles: safety margin of transpedicular screw fixation in malaysian malay population
    • Liau KM, Yusof MI, Abdullah MS, Abdullah S, Yusof AH (2006) Computed tomographic morphometry of thoracic pedicles: safety margin of transpedicular screw fixation in malaysian malay population. Spine (Phila Pa 1976) 31(16):E545–E550. doi:10.1097/01.brs.0000225978.97652.e0
    • (2006) Spine (Phila Pa 1976) , vol.31 , Issue.16 , pp. E545-E550
    • Liau, K.M.1    Yusof, M.I.2    Abdullah, M.S.3    Abdullah, S.4    Yusof, A.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.