메뉴 건너뛰기




Volumn 24, Issue 11, 2016, Pages 3474-3481

Computer navigation is effective in reducing blood loss but has no effect on transfusion requirement following primary total knee arthroplasty: a meta-analysis

Author keywords

Blood loss; Computer assisted; Navigation; Total knee arthroplasty; Transfusion

Indexed keywords

BLOOD LOSS, SURGICAL; BLOOD TRANSFUSION; COMPUTER ASSISTED SURGERY; DRAINAGE; HUMAN; KNEE REPLACEMENT; META ANALYSIS; POSTOPERATIVE HEMORRHAGE; PROCEDURES; UTILIZATION;

EID: 84975780723     PISSN: 09422056     EISSN: 14337347     Source Type: Journal    
DOI: 10.1007/s00167-016-4053-x     Document Type: Article
Times cited : (25)

References (34)
  • 1
    • 84865376857 scopus 로고    scopus 로고
    • Computer assisted versus conventional total knee replacement: a comparison of tourniquet time, blood loss and length of stay
    • PID: 22197632
    • Ajwani SH, Jones M, Jarratt JW, Shepard GJ, Ryan WG (2012) Computer assisted versus conventional total knee replacement: a comparison of tourniquet time, blood loss and length of stay. Knee 19:606–610
    • (2012) Knee , vol.19 , pp. 606-610
    • Ajwani, S.H.1    Jones, M.2    Jarratt, J.W.3    Shepard, G.J.4    Ryan, W.G.5
  • 2
    • 75449091200 scopus 로고    scopus 로고
    • Postoperative morbidity and mortality following total knee arthroplasty with computer navigation
    • PID: 19758806
    • Browne JA, Cook C, Hofmann AA, Bolognesi MP (2010) Postoperative morbidity and mortality following total knee arthroplasty with computer navigation. Knee 17:152–156
    • (2010) Knee , vol.17 , pp. 152-156
    • Browne, J.A.1    Cook, C.2    Hofmann, A.A.3    Bolognesi, M.P.4
  • 3
    • 79958167808 scopus 로고    scopus 로고
    • Blood loss after minimally invasive total knee arthroplasty: effects of imageless navigation
    • PID: 20466333
    • Chang CW, Wu PT, Yang CY (2010) Blood loss after minimally invasive total knee arthroplasty: effects of imageless navigation. Kaohsiung J Med Sci 26:237–243
    • (2010) Kaohsiung J Med Sci , vol.26 , pp. 237-243
    • Chang, C.W.1    Wu, P.T.2    Yang, C.Y.3
  • 4
    • 4444262696 scopus 로고    scopus 로고
    • Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol)
    • COI: 1:STN:280:DC%2BD2cvisVOhuw%3D%3D, PID: 15330021
    • Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM (2004) Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol). J Bone Joint Surg Br 86:818–823
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 818-823
    • Chauhan, S.K.1    Clark, G.W.2    Lloyd, S.3    Scott, R.G.4    Breidahl, W.5    Sikorski, J.M.6
  • 5
    • 77952511607 scopus 로고    scopus 로고
    • Does minimally invasive surgery improve short-term recovery in total knee arthroplasty?
    • PID: 20229136
    • Cheng T, Liu T, Zhang G, Peng X, Zhang X (2010) Does minimally invasive surgery improve short-term recovery in total knee arthroplasty? Clin Orthop Relat Res 468:1635–1648
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 1635-1648
    • Cheng, T.1    Liu, T.2    Zhang, G.3    Peng, X.4    Zhang, X.5
  • 6
    • 52949115261 scopus 로고    scopus 로고
    • Comparative study between computer assisted-navigation and conventional technique in minimally invasive surgery total knee arthroplasty, prospective control study
    • PID: 18843868
    • Chotanaphuti T, Ongnamthip P, Teeraleekul K, Kraturerk C (2008) Comparative study between computer assisted-navigation and conventional technique in minimally invasive surgery total knee arthroplasty, prospective control study. J Med Assoc Thai 91:1382–1388
    • (2008) J Med Assoc Thai , vol.91 , pp. 1382-1388
    • Chotanaphuti, T.1    Ongnamthip, P.2    Teeraleekul, K.3    Kraturerk, C.4
  • 7
    • 72349089637 scopus 로고    scopus 로고
    • Blood loss in computer-assisted mobile bearing total knee arthroplasty. A comparison of computer-assisted surgery with a conventional technique
    • COI: 1:STN:280:DC%2BD1MjnvFWhuw%3D%3D, PID: 18762940
    • Conteduca F, Massai F, Iorio R, Zanzotto E, Luzon D, Ferretti A (2009) Blood loss in computer-assisted mobile bearing total knee arthroplasty. A comparison of computer-assisted surgery with a conventional technique. Int Orthop 33:1609–1613
    • (2009) Int Orthop , vol.33 , pp. 1609-1613
    • Conteduca, F.1    Massai, F.2    Iorio, R.3    Zanzotto, E.4    Luzon, D.5    Ferretti, A.6
  • 8
    • 37849006470 scopus 로고    scopus 로고
    • Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty. A prospective, randomized study
    • PID: 18171951
    • Dutton AQ, Yeo SJ, Yang KY, Lo NN, Chia KU, Chong HC (2008) Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty. A prospective, randomized study. J Bone Joint Surg Am 90:2–9
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 2-9
    • Dutton, A.Q.1    Yeo, S.J.2    Yang, K.Y.3    Lo, N.N.4    Chia, K.U.5    Chong, H.C.6
  • 10
    • 33750576526 scopus 로고    scopus 로고
    • Blood loss after navigation-assisted minimally invasive total knee arthroplasty
    • PID: 17407945
    • Eum DS, Lee HK, Hwang SY, Park JU (2006) Blood loss after navigation-assisted minimally invasive total knee arthroplasty. Orthopedics 29:S152–S154
    • (2006) Orthopedics , vol.29 , pp. S152-S154
    • Eum, D.S.1    Lee, H.K.2    Hwang, S.Y.3    Park, J.U.4
  • 11
    • 0025948481 scopus 로고
    • Unwashed filtered shed blood collected after knee and hip arthroplasties. A source of autologous red blood cells
    • COI: 1:STN:280:DyaK3MzmsFOktA%3D%3D, PID: 1890117
    • Faris PM, Ritter M, Keating E, Valeri C (1991) Unwashed filtered shed blood collected after knee and hip arthroplasties. A source of autologous red blood cells. J Bone Joint Surg 73:1169–1178
    • (1991) J Bone Joint Surg , vol.73 , pp. 1169-1178
    • Faris, P.M.1    Ritter, M.2    Keating, E.3    Valeri, C.4
  • 13
    • 28444459488 scopus 로고    scopus 로고
    • Blood loss after total knee replacement: effects of computer-assisted surgery
    • COI: 1:STN:280:DC%2BD2Mrot1Oitw%3D%3D, PID: 16260662
    • Kalairajah Y, Simpson D, Cossey AJ, Verrall GM, Spriggins AJ (2005) Blood loss after total knee replacement: effects of computer-assisted surgery. J Bone Joint Surg Br 87:1480–1482
    • (2005) J Bone Joint Surg Br , vol.87 , pp. 1480-1482
    • Kalairajah, Y.1    Simpson, D.2    Cossey, A.J.3    Verrall, G.M.4    Spriggins, A.J.5
  • 14
    • 0033761939 scopus 로고    scopus 로고
    • Plugging the intramedullary canal of the femur in total knee arthroplasty: reduction in postoperative blood loss
    • COI: 1:STN:280:DC%2BD3crgvV2qtg%3D%3D, PID: 11061459
    • Kumar N, Saleh J, Gardiner E, Devadoss VG, Howell FR (2000) Plugging the intramedullary canal of the femur in total knee arthroplasty: reduction in postoperative blood loss. J Arthroplasty 15:947–949
    • (2000) J Arthroplasty , vol.15 , pp. 947-949
    • Kumar, N.1    Saleh, J.2    Gardiner, E.3    Devadoss, V.G.4    Howell, F.R.5
  • 15
    • 79956132397 scopus 로고    scopus 로고
    • Shed blood re-transfusion provides no benefit in computer-assisted primary total knee arthroplasty
    • PID: 20814664
    • Lee DH, Padhy D, Lee SH, Kim TK, Choi J, Han SB (2011) Shed blood re-transfusion provides no benefit in computer-assisted primary total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 19:926–931
    • (2011) Knee Surg Sports Traumatol Arthrosc , vol.19 , pp. 926-931
    • Lee, D.H.1    Padhy, D.2    Lee, S.H.3    Kim, T.K.4    Choi, J.5    Han, S.B.6
  • 16
    • 77951297990 scopus 로고    scopus 로고
    • Accuracy of soft tissue balancing in TKA: comparison between navigation-assisted gap balancing and conventional measured resection
    • COI: 1:CAS:528:DC%2BC3cXhtl2ntbrP, PID: 19924399
    • Lee DH, Park JH, Song DI, Padhy D, Jeong WK, Han SB (2010) Accuracy of soft tissue balancing in TKA: comparison between navigation-assisted gap balancing and conventional measured resection. Knee Surg Sports Traumatol Arthrosc 18:381–387
    • (2010) Knee Surg Sports Traumatol Arthrosc , vol.18 , pp. 381-387
    • Lee, D.H.1    Park, J.H.2    Song, D.I.3    Padhy, D.4    Jeong, W.K.5    Han, S.B.6
  • 17
    • 80053077985 scopus 로고    scopus 로고
    • Prospective non-randomized comparative clinical outcome of computer assisted total knee arthroplasty with and without a minimally invasive approach
    • PID: 21970198
    • Leelasestaporn C (2011) Prospective non-randomized comparative clinical outcome of computer assisted total knee arthroplasty with and without a minimally invasive approach. J Med Assoc Thai 94:1089–1095
    • (2011) J Med Assoc Thai , vol.94 , pp. 1089-1095
    • Leelasestaporn, C.1
  • 18
    • 84941877424 scopus 로고    scopus 로고
    • Modern abbreviated computer navigation of the femur reduces blood loss in total knee arthroplasty
    • PID: 25971778
    • Licini DJ, Meneghini RM (2015) Modern abbreviated computer navigation of the femur reduces blood loss in total knee arthroplasty. J Arthroplasty 30(10):1729–1732
    • (2015) J Arthroplasty , vol.30 , Issue.10 , pp. 1729-1732
    • Licini, D.J.1    Meneghini, R.M.2
  • 19
    • 37348999244 scopus 로고    scopus 로고
    • Effect of flexion/extension splintage post total knee arthroplasty on blood loss and range of motion—a randomised controlled trial
    • COI: 1:STN:280:DC%2BD1c%2FgtVygsA%3D%3D, PID: 17997100
    • Ma T, Khan RJ, Carey Smith R, Nivbrant B, Wood DJ (2008) Effect of flexion/extension splintage post total knee arthroplasty on blood loss and range of motion—a randomised controlled trial. Knee 15:15–19
    • (2008) Knee , vol.15 , pp. 15-19
    • Ma, T.1    Khan, R.J.2    Carey Smith, R.3    Nivbrant, B.4    Wood, D.J.5
  • 21
    • 84858118037 scopus 로고    scopus 로고
    • Blood loss following total knee replacement is reduced when using computer-assisted versus standard methods
    • PID: 22523931
    • McConnell J, Dillon J, Kinninmonth A, Sarungi M, Picard F (2012) Blood loss following total knee replacement is reduced when using computer-assisted versus standard methods. Acta Orthop Belg 78:75–79
    • (2012) Acta Orthop Belg , vol.78 , pp. 75-79
    • McConnell, J.1    Dillon, J.2    Kinninmonth, A.3    Sarungi, M.4    Picard, F.5
  • 22
    • 84861710918 scopus 로고    scopus 로고
    • Reducing blood loss in primary knee arthroplasty: a prospective randomised controlled trial of tranexamic acid and fibrin spray
    • PID: 21733697
    • McConnell JS, Shewale S, Munro NA, Shah K, Deakin AH, Kinninmonth AW (2012) Reducing blood loss in primary knee arthroplasty: a prospective randomised controlled trial of tranexamic acid and fibrin spray. Knee 19:295–298
    • (2012) Knee , vol.19 , pp. 295-298
    • McConnell, J.S.1    Shewale, S.2    Munro, N.A.3    Shah, K.4    Deakin, A.H.5    Kinninmonth, A.W.6
  • 23
    • 84925097054 scopus 로고    scopus 로고
    • Hidden blood loss and its influential factors after total hip arthroplasty
    • PID: 25889223
    • Miao K, Ni S, Zhou X, Xu N, Sun R, Zhuang C, Wang Y (2015) Hidden blood loss and its influential factors after total hip arthroplasty. J Orthop Surg Res 10:36
    • (2015) J Orthop Surg Res , vol.10 , pp. 36
    • Miao, K.1    Ni, S.2    Zhou, X.3    Xu, N.4    Sun, R.5    Zhuang, C.6    Wang, Y.7
  • 24
    • 79451471237 scopus 로고    scopus 로고
    • Blood loss following total knee replacement in the morbidly obese: effects of computer navigation
    • PID: 20591675
    • Millar NL, Deakin AH, Millar LL, Kinnimonth AW, Picard F (2011) Blood loss following total knee replacement in the morbidly obese: effects of computer navigation. Knee 18:108–112
    • (2011) Knee , vol.18 , pp. 108-112
    • Millar, N.L.1    Deakin, A.H.2    Millar, L.L.3    Kinnimonth, A.W.4    Picard, F.5
  • 25
    • 84875546950 scopus 로고    scopus 로고
    • Comparison of blood loss between computer assisted and conventional total knee arthroplasty
    • PID: 23532765
    • Mohanlal PK, Sandiford N, Skinner JA, Samsani S (2013) Comparison of blood loss between computer assisted and conventional total knee arthroplasty. Indian J Orthop 47:63–66
    • (2013) Indian J Orthop , vol.47 , pp. 63-66
    • Mohanlal, P.K.1    Sandiford, N.2    Skinner, J.A.3    Samsani, S.4
  • 26
    • 84875698791 scopus 로고    scopus 로고
    • Factors correlated with the reducibility of varus deformity in knee osteoarthritis: an analysis using navigation guided TKA
    • PID: 23467320
    • Moon YW, Kim JG, Han JH, Do KH, Seo JG, Lim HC (2013) Factors correlated with the reducibility of varus deformity in knee osteoarthritis: an analysis using navigation guided TKA. Clin Orthop Surg 5:36–43
    • (2013) Clin Orthop Surg , vol.5 , pp. 36-43
    • Moon, Y.W.1    Kim, J.G.2    Han, J.H.3    Do, K.H.4    Seo, J.G.5    Lim, H.C.6
  • 27
    • 84903512939 scopus 로고    scopus 로고
    • Navigated versus conventional total knee arthroplasty
    • PID: 24234551
    • Moskal JT, Capps SG, Mann JW, Scanelli JA (2014) Navigated versus conventional total knee arthroplasty. J Knee Surg 27:235–248
    • (2014) J Knee Surg , vol.27 , pp. 235-248
    • Moskal, J.T.1    Capps, S.G.2    Mann, J.W.3    Scanelli, J.A.4
  • 29
    • 84992695951 scopus 로고    scopus 로고
    • Comparison of precision between optical and electromagnetic navigation systems in total knee arthroplasty
    • PID: 25505703
    • Rhee SJ, Park SH, Cho HM, Suh JT (2014) Comparison of precision between optical and electromagnetic navigation systems in total knee arthroplasty. Knee Surg Relat Res 26:214–221
    • (2014) Knee Surg Relat Res , vol.26 , pp. 214-221
    • Rhee, S.J.1    Park, S.H.2    Cho, H.M.3    Suh, J.T.4
  • 30
    • 84919787657 scopus 로고    scopus 로고
    • Intravenous use of tranexamic acid reduces postoperative blood loss in total knee arthroplasty
    • PID: 25179896
    • Sabatini L, Atzori F, Revello S, Scotti L, Debiasi F, Masse A (2014) Intravenous use of tranexamic acid reduces postoperative blood loss in total knee arthroplasty. Arch Orthop Trauma Surg 134:1609–1614
    • (2014) Arch Orthop Trauma Surg , vol.134 , pp. 1609-1614
    • Sabatini, L.1    Atzori, F.2    Revello, S.3    Scotti, L.4    Debiasi, F.5    Masse, A.6
  • 31
    • 77955615949 scopus 로고    scopus 로고
    • The effect of computer navigation on blood loss and transfusion rate in TKA
    • PID: 20608630
    • Schnurr C, Csecsei G, Eysel P, Konig DP (2010) The effect of computer navigation on blood loss and transfusion rate in TKA. Orthopedics 33:474
    • (2010) Orthopedics , vol.33 , pp. 474
    • Schnurr, C.1    Csecsei, G.2    Eysel, P.3    Konig, D.P.4
  • 32
    • 67349099096 scopus 로고    scopus 로고
    • Timing of tourniquet release in total knee arthroplasty when using a postoperative blood salvage drain
    • PID: 18534405
    • Steffin B, Green-Riviere E, Giori NJ (2009) Timing of tourniquet release in total knee arthroplasty when using a postoperative blood salvage drain. J Arthroplasty 24:539–542
    • (2009) J Arthroplasty , vol.24 , pp. 539-542
    • Steffin, B.1    Green-Riviere, E.2    Giori, N.J.3
  • 33
    • 77950354323 scopus 로고    scopus 로고
    • A comparison of blood loss in minimally invasive surgery with and without electromagnetic computer navigation in total knee arthroplasty
    • PID: 20120662
    • Thiengwittayaporn S, Junsee D, Tanavalee A (2009) A comparison of blood loss in minimally invasive surgery with and without electromagnetic computer navigation in total knee arthroplasty. J Med Assoc Thai 92(Suppl 6):S27–S32
    • (2009) J Med Assoc Thai , vol.92 , pp. S27-S32
    • Thiengwittayaporn, S.1    Junsee, D.2    Tanavalee, A.3
  • 34
    • 84992718732 scopus 로고    scopus 로고
    • Losos M, Tugwell P: The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomized studies in meta-analyses
    • Wells G, Shea B, O’Connell D, Peterson J, Welch V, Losos M, Tugwell P (2013) The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomized studies in meta-analyses. www.ohri.ca/programs/clinical_epidemiology/oxford.htm
    • (2013) Welch , vol.5
    • Wells, G.1    Shea, B.2    O’Connell, D.3    Peterson, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.