메뉴 건너뛰기




Volumn 78, Issue 1, 2012, Pages 75-79

Blood loss following total knee replacement is reduced when using computer-assisted versus standard methods

Author keywords

Blood loss; Computer assisted surgery; Knee arthroplasty; Knee replacement

Indexed keywords

AGED; ARTICLE; BLEEDING; COMPARATIVE STUDY; COMPUTER ASSISTED SURGERY; FEMALE; HEMATOCRIT; HUMAN; KNEE ARTHROPLASTY; MALE; METHODOLOGY; MIDDLE AGED; RETROSPECTIVE STUDY;

EID: 84858118037     PISSN: 00016462     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (36)

References (23)
  • 1
    • 0029891721 scopus 로고    scopus 로고
    • Fibrinolytic inhibition with tranexamic acid reduces blood loss and blood transfusion after knee arthroplasty: A prospective, randomised, double-blind study of 86 patients
    • Benoni G, Fredin H. Fibrinolytic inhibition with tranexamic acid reduces blood loss and blood transfusion after knee arthroplasty: a prospective, randomised, doubleblind study of 86 patients. J Bone Joint Surg 1996;78-B:434-440. (Pubitemid 26158834)
    • (1996) Journal of Bone and Joint Surgery - Series B , vol.78 , Issue.3 , pp. 434-440
    • Benoni, G.1    Fredin, H.2
  • 3
    • 0028931857 scopus 로고
    • Multiple significance tests: The Bonferroni method
    • Bland JM, Altman DG. Multiple significance tests: the Bonferroni method. BMJ 1995;310:170.
    • (1995) BMJ , vol.310 , pp. 170
    • Bland, J.M.1    Altman, D.G.2
  • 4
    • 0016336759 scopus 로고
    • Estimating allowable haemodilution
    • Bourke DL, Smith TC. Estimating allowable haemodilution. Anaesthesiology 1974;41:609-612.
    • (1974) Anaesthesiology , vol.41 , pp. 609-612
    • Bourke, D.L.1    Smith, T.C.2
  • 5
    • 2342432329 scopus 로고    scopus 로고
    • Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial
    • DOI 10.1302/0301-620X.86B3.14643
    • Chauhan SK, Scott RG, Breidahl W, Beaver RJ. Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Joint Surg 2004;86-B:372-377. (Pubitemid 38559489)
    • (2004) Journal of Bone and Joint Surgery - Series B , vol.86 , Issue.3 , pp. 372-377
    • Chauhan, S.K.1    Scott, R.G.2    Breidahl, W.3    Beaver, R.J.4
  • 7
    • 0142030624 scopus 로고    scopus 로고
    • Use of intravenous tranexamic acid to reduce allogeneic blood transfusion in total hip and knee arthroplasty: A meta-analysis
    • Ho KM, Ismail H. Use of intravenous tranexamic acid to reduce allogeneic blood transfusion in total hip and knee arthroplasty: a meta-analysis. Anaesth Intensive Care 2003;31:529-537. (Pubitemid 37265248)
    • (2003) Anaesthesia and Intensive Care , vol.31 , Issue.5 , pp. 529-537
    • Ho, K.M.1    Ismail, H.2
  • 10
    • 0033761939 scopus 로고    scopus 로고
    • Plugging the intramedullary canal of the femur in total knee arthroplasty: Reduction in postoperative blood loss
    • Kumar N, Saleh J, Gardiner E, Devadoss VG, Howell FR. Plugging the intramedullary canal of the femur in total knee arthroplasty: reduction in postoperative blood loss. J Arthroplasty 2000;15:947-949.
    • (2000) J Arthroplasty , vol.15 , pp. 947-949
    • Kumar, N.1    Saleh, J.2    Gardiner, E.3    Devadoss, V.G.4    Howell, F.R.5
  • 12
    • 53649088341 scopus 로고    scopus 로고
    • Strategies for blood management in orthopaedic and trauma surgery
    • Lemaire R. Strategies for blood management in orthopaedic and trauma surgery. J Bone Joint Surg 2008;90-B:1128-1136.
    • (2008) J Bone Joint Surg , vol.90 B , pp. 1128-1136
    • Lemaire, R.1
  • 13
    • 0026044701 scopus 로고
    • Blood loss after total knee replacement: Effect of tourniquet release and continuous passive motion
    • Lotke PA, Faralli VJ, Orenstein EM, Ecker ML. Blood loss after total knee replacement: effect of tourniquet release and continuous passive motion. J Bone Joint Surg 1991;73-A:1037-1040.
    • (1991) J Bone Joint Surg , vol.73 A , pp. 1037-1040
    • Lotke, P.A.1    Faralli, V.J.2    Orenstein, E.M.3    Ecker, M.L.4
  • 14
    • 79451471237 scopus 로고    scopus 로고
    • Blood loss following total knee replacement in the morbidly obese: Effects of computer navigation
    • Millar NL, Deakin AH, Millar LL, Kinnimonth AWG, Picard F. Blood loss following total knee replacement in the morbidly obese: Effects of computer navigation. Knee 2011;18:108-112.
    • (2011) Knee , vol.18 , pp. 108-112
    • Millar, N.L.1    Deakin, A.H.2    Millar, L.L.3    Kinnimonth, A.W.G.4    Picard, F.5
  • 15
    • 0025689517 scopus 로고
    • Fatal fat embolism following total condylar knee arthroplasty
    • Monto RR, Garcia J, Callaghan JJ. Fatal fat embolism following total condylar knee arthroplasty. J Arthroplasty 1990;5:291-299.
    • (1990) J Arthroplasty , vol.5 , pp. 291-299
    • Monto, R.R.1    Garcia, J.2    Callaghan, J.J.3
  • 16
    • 0000719057 scopus 로고
    • Prediction of blood volume in normal human adults
    • Nadler SB, Hidalgo JU, Bloch T. Prediction of blood volume in normal human adults. Surgery 1962;51:224-232.
    • (1962) Surgery , vol.51 , pp. 224-232
    • Nadler, S.B.1    Hidalgo, J.U.2    Bloch, T.3
  • 17
    • 23344444417 scopus 로고    scopus 로고
    • Comparison between two methods of drain clamping after total knee arthroplasty
    • DOI 10.1007/s00402-005-0813-7
    • Prasad N, Padmanabhan V, Mullaji A. Comparison between two methods of drain clamping after total knee arthroplasty. Arch Orthop Trauma Surg 2005;125:381-384. (Pubitemid 41102409)
    • (2005) Archives of Orthopaedic and Trauma Surgery , vol.125 , Issue.6 , pp. 381-384
    • Prasad, N.1    Padmanabhan, V.2    Mullaji, A.3
  • 18
    • 33644977023 scopus 로고    scopus 로고
    • Delayed release of drain in total knee replacement reduces blood loss. A prospective randomised study
    • Roy N, Smith M, Anwar M, Elsworth C. Delayed release of drain in total knee replacement reduces blood loss. A prospective randomised study. Acta Orthop Belg 2006;72:34-38.
    • (2006) Acta Orthop Belg , vol.72 , pp. 34-38
    • Roy, N.1    Smith, M.2    Anwar, M.3    Elsworth, C.4
  • 19
    • 0034233873 scopus 로고    scopus 로고
    • How much blood is really lost in total knee arthroplasty? Correct blood loss management should take hidden loss into account
    • DOI 10.1016/S0968-0160(00)00047-8, PII S0968016000000478
    • Sehat KR, Evans R, Newman JH. How much blood is really lost in total knee arthroplasty ? Correct blood loss management should take hidden loss into account. Knee 2000;7:151-155. (Pubitemid 30601705)
    • (2000) Knee , vol.7 , Issue.3 , pp. 151-155
    • Sehat, K.R.1    Evans, R.2    Newman, J.H.3
  • 20
    • 2442700410 scopus 로고    scopus 로고
    • Hidden blood loss following hip and knee arthroplasty: Correct management of blood loss should take hidden loss into account
    • Sehat KR, Evans RL, Newman JH. Hidden blood loss following hip and knee arthroplasty. Correct management of blood loss should take hidden loss into account. J Bone Joint Surg 2004;86-B:561-565. (Pubitemid 38660062)
    • (2004) Journal of Bone and Joint Surgery - Series B , vol.86 , Issue.4 , pp. 561-565
    • Sehat, K.R.1    Evans, R.L.2    Newman, J.H.3
  • 21
    • 26844529995 scopus 로고    scopus 로고
    • Comparison between 4-hour clamping drainage and nonclamping drainage after total knee arthroplasty
    • DOI 10.1016/j.arth.2005.01.017, PII S088354030500121X
    • Shen P-C, Jou I-M, Lin Y-T et al. Comparison between 4-hour clamping drainage and nonclamping drainage after total knee arthroplasty. J Arthroplasty 2005;20:909-913. (Pubitemid 41463693)
    • (2005) Journal of Arthroplasty , vol.20 , Issue.7 , pp. 909-913
    • Shen, P.-C.1    Jou, I.-M.2    Lin, Y.-T.3    Lai, K.-A.4    Yang, C.-Y.5    Chern, T.-C.6
  • 22
    • 0842342596 scopus 로고    scopus 로고
    • Strategies for minimizing blood loss in orthopedic surgery
    • Tobias JD. Strategies for minimizing blood loss in orthopedic surgery. Semin Hematol 2004;41:145-156. (Pubitemid 38182731)
    • (2004) Seminars in Hematology , vol.41 , Issue.1 SUPPL. 1 , pp. 145-156
    • Tobias, J.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.