메뉴 건너뛰기




Volumn 22, Issue 6, 2015, Pages 609-612

MRI is more accurate than CT for patient-specific total knee arthroplasty

Author keywords

CT; Custom cutting blocks; MRI; Patient specific; Total knee arthroplasty

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; HUMAN; INTERMETHOD COMPARISON; KNEE; KNEE OSTEOARTHRITIS; KNEE PROSTHESIS; KNEE RADIOGRAPHY; MALE; MEASUREMENT ACCURACY; MECHANICAL AXIS; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PATIENT POSITION SUPPORT; PRIORITY JOURNAL; RETROSPECTIVE STUDY; TOTAL KNEE ARTHROPLASTY; COMPUTER ASSISTED SURGERY; FOLLOW UP; KNEE REPLACEMENT; MIDDLE AGED; OSTEOARTHRITIS, KNEE; PATHOLOGY; PROCEDURES; PROSTHETIC FITTING; RADIOGRAPHY; REPRODUCIBILITY; THREE DIMENSIONAL IMAGING; VERY ELDERLY;

EID: 84973407769     PISSN: 09680160     EISSN: 18735800     Source Type: Journal    
DOI: 10.1016/j.knee.2015.02.014     Document Type: Article
Times cited : (31)

References (20)
  • 1
    • 77956999796 scopus 로고    scopus 로고
    • Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements
    • Sep 15
    • Parratte S., Pagnano M.W., Trousdale R.T., Berry D.J. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am Sep 15, 2010, 92(12):2143-2149.
    • (2010) J Bone Joint Surg Am , vol.92 , Issue.12 , pp. 2143-2149
    • Parratte, S.1    Pagnano, M.W.2    Trousdale, R.T.3    Berry, D.J.4
  • 2
    • 79954436339 scopus 로고    scopus 로고
    • Varus malalignment has no influence on clinical outcome in midterm follow-up after total knee replacement
    • [Epub 2010 Feb 18]
    • Matziolis G., Adam J., Perka C. Varus malalignment has no influence on clinical outcome in midterm follow-up after total knee replacement. Arch Orthop Trauma Surg Dec 2010, 130(12):1487-1491. [Epub 2010 Feb 18].
    • (2010) Arch Orthop Trauma Surg , vol.130 , Issue.12 , pp. 1487-1491
    • Matziolis, G.1    Adam, J.2    Perka, C.3
  • 3
    • 68749101913 scopus 로고    scopus 로고
    • Coronal alignment in total knee arthroplasty: just how important is it?
    • [Epub 2009 Jun 24]
    • Fang D.M., Ritter M.A., Davis K.E. Coronal alignment in total knee arthroplasty: just how important is it?. J Arthroplasty Sep 2009, 24(6 Suppl.):39-43. [Epub 2009 Jun 24].
    • (2009) J Arthroplasty , vol.24 , Issue.6 , pp. 39-43
    • Fang, D.M.1    Ritter, M.A.2    Davis, K.E.3
  • 4
    • 80052806529 scopus 로고    scopus 로고
    • Neutral mechanical alignment: a requirement for successful TKA: affirms
    • Sep 9
    • Lombardi A.V., Berend K.R., Ng V.Y. Neutral mechanical alignment: a requirement for successful TKA: affirms. Orthopedics Sep 9, 2011, 34(9).
    • (2011) Orthopedics , vol.34 , Issue.9
    • Lombardi, A.V.1    Berend, K.R.2    Ng, V.Y.3
  • 5
    • 0036903403 scopus 로고    scopus 로고
    • The effects of varus tibial alignment on proximal tibial surface strain in total knee arthroplasty: the posteromedial hot spot
    • Green G.V., Berend K.R., Berend M.E., Glisson R.R., Vail T.P. The effects of varus tibial alignment on proximal tibial surface strain in total knee arthroplasty: the posteromedial hot spot. J Arthroplasty 2002, 17(8):1033-1039.
    • (2002) J Arthroplasty , vol.17 , Issue.8 , pp. 1033-1039
    • Green, G.V.1    Berend, K.R.2    Berend, M.E.3    Glisson, R.R.4    Vail, T.P.5
  • 6
    • 0036152768 scopus 로고    scopus 로고
    • The effect of malalignment on stresses in polyethylene component of total knee prostheses-a finite element analysis
    • Liau J.J., Cheng C.K., Huang C.H., Lo W.H. The effect of malalignment on stresses in polyethylene component of total knee prostheses-a finite element analysis. Clin Biomech (Bristol, Avon) 2002, 17(2):140-146.
    • (2002) Clin Biomech (Bristol, Avon) , vol.17 , Issue.2 , pp. 140-146
    • Liau, J.J.1    Cheng, C.K.2    Huang, C.H.3    Lo, W.H.4
  • 7
    • 67349203304 scopus 로고    scopus 로고
    • Good alignment after total knee arthroplasty leads to faster rehabilitation and better function [published online ahead of print May 19, 2008]
    • Longstaff L.M., Sloan K., Stamp N., Scaddan M., Beaver R. Good alignment after total knee arthroplasty leads to faster rehabilitation and better function [published online ahead of print May 19, 2008]. J Arthroplasty 2009, 24(4):570-578.
    • (2009) J Arthroplasty , vol.24 , Issue.4 , pp. 570-578
    • Longstaff, L.M.1    Sloan, K.2    Stamp, N.3    Scaddan, M.4    Beaver, R.5
  • 9
    • 84861823763 scopus 로고    scopus 로고
    • Maximizing surgeon and hospital total knee arthroplasty volume using customized patient instrumentation and swing operating rooms
    • Duffy G.P. Maximizing surgeon and hospital total knee arthroplasty volume using customized patient instrumentation and swing operating rooms. Am J Orthop (Belle Mead NJ) Nov 2011, 40(11 Suppl.):5-8.
    • (2011) Am J Orthop (Belle Mead NJ) , vol.40 , Issue.11 , pp. 5-8
    • Duffy, G.P.1
  • 10
    • 84861808002 scopus 로고    scopus 로고
    • The benefits of customized patient instrumentation to lower-volume joint replacement surgeons: results from practice
    • Johnson D.R. The benefits of customized patient instrumentation to lower-volume joint replacement surgeons: results from practice. Am J Orthop (Belle Mead NJ) Nov 2011, 40(11 Suppl.):13-16.
    • (2011) Am J Orthop (Belle Mead NJ) , vol.40 , Issue.11 , pp. 13-16
    • Johnson, D.R.1
  • 12
    • 83555176169 scopus 로고    scopus 로고
    • The value of patient-matched instrumentation in total knee arthroplasty
    • Noble J.W., Moore C.A., Liu N. The value of patient-matched instrumentation in total knee arthroplasty. J Arthroplasty Jan 2012, 27(1):153-155.
    • (2012) J Arthroplasty , vol.27 , Issue.1 , pp. 153-155
    • Noble, J.W.1    Moore, C.A.2    Liu, N.3
  • 13
    • 80052617000 scopus 로고    scopus 로고
    • Analysis of procedure-related costs and proposed benefits of using patient-specific approach in total knee arthroplasty
    • Watters T.S., Mather R.C., Browne J.A., Berend K.R., Lombardi A.V., Bolognesi M.P. Analysis of procedure-related costs and proposed benefits of using patient-specific approach in total knee arthroplasty. J Surg Orthop Adv Summer 2011, 20(2):112-116.
    • (2011) J Surg Orthop Adv , vol.20 , Issue.2 , pp. 112-116
    • Watters, T.S.1    Mather, R.C.2    Browne, J.A.3    Berend, K.R.4    Lombardi, A.V.5    Bolognesi, M.P.6
  • 14
    • 54849442895 scopus 로고    scopus 로고
    • Accuracy of MRI vs CT imaging with particular reference to patient specific templates for total knee replacement surgery
    • White D., Chelule K.L., Seedhom B.B. Accuracy of MRI vs CT imaging with particular reference to patient specific templates for total knee replacement surgery. Int J Med Robot 2008, 4(3):224-231.
    • (2008) Int J Med Robot , vol.4 , Issue.3 , pp. 224-231
    • White, D.1    Chelule, K.L.2    Seedhom, B.B.3
  • 15
    • 84861188144 scopus 로고    scopus 로고
    • Custom-fit total knee arthroplasty: our initial experience in 32 knees
    • Bali K., Walker P., Bruce W. Custom-fit total knee arthroplasty: our initial experience in 32 knees. J Arthroplasty 2012, 27(6):1149-1154.
    • (2012) J Arthroplasty , vol.27 , Issue.6 , pp. 1149-1154
    • Bali, K.1    Walker, P.2    Bruce, W.3
  • 16
    • 84855562280 scopus 로고    scopus 로고
    • Cost-effectiveness analysis of custom total knee cutting blocks
    • Slover J.D., Rubash H.E., Malchau H., Bosco J.A. Cost-effectiveness analysis of custom total knee cutting blocks. J Arthroplasty 2012, 27(2):180-185.
    • (2012) J Arthroplasty , vol.27 , Issue.2 , pp. 180-185
    • Slover, J.D.1    Rubash, H.E.2    Malchau, H.3    Bosco, J.A.4
  • 18
    • 37349078592 scopus 로고    scopus 로고
    • Custom-fit total knee arthroplasty (OtisKnee) results in malalignment
    • Klatt B.A., Goyal N., Austin M.S., Hozack W.J. Custom-fit total knee arthroplasty (OtisKnee) results in malalignment. J Arthroplasty 2008, 23(1):26-29.
    • (2008) J Arthroplasty , vol.23 , Issue.1 , pp. 26-29
    • Klatt, B.A.1    Goyal, N.2    Austin, M.S.3    Hozack, W.J.4
  • 19
    • 84865102501 scopus 로고    scopus 로고
    • Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA
    • Ng V.Y., DeClaire J.H., Berend K.R., Gulick B.C., Lombardi A.V. Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 2012, 470:99-107.
    • (2012) Clin Orthop Relat Res , vol.470 , pp. 99-107
    • Ng, V.Y.1    DeClaire, J.H.2    Berend, K.R.3    Gulick, B.C.4    Lombardi, A.V.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.