1
-
-
33746382563
-
Oxidase-coupled amperometric glucose and lactate sensors with integrated electrochemical actuation system
-
Park, J.; Kim, C.S.; Choi, M. Oxidase-coupled amperometric glucose and lactate sensors with integrated electrochemical actuation system. IEEE Trans. Instrum. Meas. 2006, 55, 1348–1355.
-
(2006)
IEEE Trans. Instrum. Meas.
, vol.55
, pp. 1348-1355
-
-
Park, J.1
Kim, C.S.2
Choi, M.3
-
2
-
-
84893081088
-
Characterization of a wireless potentiostat for integration with a novel implantable biotransducer
-
Kotanen, C.; Guiseppi-Elie, A. Characterization of a wireless potentiostat for integration with a novel implantable biotransducer. IEEE Sens. J. 2013, 14, 768–776.
-
(2013)
IEEE Sens. J.
, vol.14
, pp. 768-776
-
-
Kotanen, C.1
Guiseppi-Elie, A.2
-
3
-
-
2342470000
-
In-device enzyme immobilization: Wafer-level fabrication of an integrated glucose sensor
-
Zimmermann, S.; Fienbork, D.; Flounders, A.W.; Liepmann, D. In-device enzyme immobilization: Wafer-level fabrication of an integrated glucose sensor. Sens. Actuator B Chem. 2004, 99, 163–173.
-
(2004)
Sens. Actuator B Chem.
, vol.99
, pp. 163-173
-
-
Zimmermann, S.1
Fienbork, D.2
Flounders, A.W.3
Liepmann, D.4
-
4
-
-
58149161723
-
Wireless enzyme sensor system for real-time monitoring of blood glucose levels in fish
-
Endo, H.; Yonemori, Y.; Hibi, K.; Ren, H.; Hayashi, T.; Tsugawa, W.; Sode, K. Wireless enzyme sensor system for real-time monitoring of blood glucose levels in fish. Biosens. Bioelectron. 2009, 24, 1417–1423.
-
(2009)
Biosens. Bioelectron.
, vol.24
, pp. 1417-1423
-
-
Endo, H.1
Yonemori, Y.2
Hibi, K.3
Ren, H.4
Hayashi, T.5
Tsugawa, W.6
Sode, K.7
-
5
-
-
84880166326
-
Role of vasopressin in maintenance of potassium homeostasis in severe hemorrhage
-
Uyehara, C.F.T.; Sarkar, J. Role of vasopressin in maintenance of potassium homeostasis in severe hemorrhage. Am. J. Physiol. Regul. Integr. Comp. Physiol. 2013, 305, R101–R103.
-
(2013)
Am. J. Physiol. Regul. Integr. Comp. Physiol.
, vol.305
, pp. R101-R103
-
-
Uyehara, C.F.T.1
Sarkar, J.2
-
7
-
-
0023363285
-
Electrochemical immobilisation of enzymes: Part II. Glucose oxidase immobilised in poly-N-methylpyrrole
-
Bartlett, P.N.; Whitaker, R.G. Electrochemical immobilisation of enzymes: Part II. Glucose oxidase immobilised in poly-N-methylpyrrole. J. Electroanal. Chem. Interfacial Electrochem. 1987, 224, 37–48.
-
(1987)
J. Electroanal. Chem. Interfacial Electrochem.
, vol.224
, pp. 37-48
-
-
Bartlett, P.N.1
Whitaker, R.G.2
-
8
-
-
0034402232
-
The mechanisms of pyrrole electropolymerization
-
Sadki, S.; Schottland, P.; Brodie, N.; Sabouraud, G. The mechanisms of pyrrole electropolymerization. Chem. Soc. Rev. 2000, 29, 283–293.
-
(2000)
Chem. Soc. Rev.
, vol.29
, pp. 283-293
-
-
Sadki, S.1
Schottland, P.2
Brodie, N.3
Sabouraud, G.4
-
9
-
-
62349085895
-
Integrated oligoaniline-cross-linked composites of Au nanoparticles/glucose oxidase electrodes: A generic paradigm for electrically contacted enzyme systems
-
Yehezkeli, O.; Yan, Y.-M.; Baravik, I.; Tel-Vered, R.; Willner, I. Integrated oligoaniline-cross-linked composites of Au nanoparticles/glucose oxidase electrodes: A generic paradigm for electrically contacted enzyme systems. Chem. Eur. J. 2009, 15, 2674–2679.
-
(2009)
Chem. Eur. J.
, vol.15
, pp. 2674-2679
-
-
Yehezkeli, O.1
Yan, Y.-M.2
Baravik, I.3
Tel-Vered, R.4
Willner, I.5
-
10
-
-
84886446557
-
3.331. Conjugated polymers for biosensor devices
-
Ducheyne, P., Ed.; Elsevier: Oxford, UK
-
Bai, J.; Beyer, S.; Trau, D. 3.331. Conjugated polymers for biosensor devices. In Comprehensive Biomaterials; Ducheyne, P., Ed.; Elsevier: Oxford, UK, 2011; pp. 529–556.
-
(2011)
Comprehensive Biomaterials
, pp. 529-556
-
-
Bai, J.1
Beyer, S.2
Trau, D.3
-
11
-
-
0028090182
-
An in situ electrosynthesized amperometric biosensor based on lactate oxidase immobilized in a poly-o-phenylenediamine film: Determination of lactate in serum by flow injection analysis
-
Palmisano, F.; Centonze, D.; Zambonin, P.G. An in situ electrosynthesized amperometric biosensor based on lactate oxidase immobilized in a poly-o-phenylenediamine film: Determination of lactate in serum by flow injection analysis. Biosens. Bioelectron. 1994, 9, 471–479.
-
(1994)
Biosens. Bioelectron.
, vol.9
, pp. 471-479
-
-
Palmisano, F.1
Centonze, D.2
Zambonin, P.G.3
-
12
-
-
2542432481
-
Preparation and bioelectrochemical responses of the poly(M-phenylenediamine) glucose oxidase electrode
-
Zhou, H.; Chen, H.; Luo, S.; Chen, J.; Wei, W.; Kuang, Y. Preparation and bioelectrochemical responses of the poly(m-phenylenediamine) glucose oxidase electrode. Sens. Actuator B Chem. 2004, 101, 224–230.
-
(2004)
Sens. Actuator B Chem.
, vol.101
, pp. 224-230
-
-
Zhou, H.1
Chen, H.2
Luo, S.3
Chen, J.4
Wei, W.5
Kuang, Y.6
-
13
-
-
12444268933
-
Oxidase enzyme immobilisation through electropolymerised films to assemble biosensors for batch and flow injection analysis
-
Badea, M.; Curulli, A.; Palleschi, G. Oxidase enzyme immobilisation through electropolymerised films to assemble biosensors for batch and flow injection analysis. Biosens. Bioelectron. 2003, 18, 689–698.
-
(2003)
Biosens. Bioelectron.
, vol.18
, pp. 689-698
-
-
Badea, M.1
Curulli, A.2
Palleschi, G.3
-
14
-
-
37049076387
-
Electrochemical immobilization of enzymes. Part V. Microelectrodes for the detection of glucose based on glucose oxidase immobilized in a poly(phenol) film
-
Bartlett, P.N.; Caruana, D.J. Electrochemical immobilization of enzymes. Part V. Microelectrodes for the detection of glucose based on glucose oxidase immobilized in a poly(phenol) film. Analyst 1992, 117, 1287–1292.
-
(1992)
Analyst
, vol.117
, pp. 1287-1292
-
-
Bartlett, P.N.1
Caruana, D.J.2
-
15
-
-
0028107679
-
Electrochemical immobilization of enzymes. Part VI. Microelectrodes for the detection of L-lactate based on flavocytochrome b2 immobilized in a poly(phenol) film
-
Bartlett, P.N.; Caruana, D.J. Electrochemical immobilization of enzymes. Part VI. Microelectrodes for the detection of L-lactate based on flavocytochrome b2 immobilized in a poly(phenol) film. Analyst 1994, 119, 175–180.
-
(1994)
Analyst
, vol.119
, pp. 175-180
-
-
Bartlett, P.N.1
Caruana, D.J.2
-
16
-
-
84882604836
-
Selective enzyme immobilization on arrayed microelectrodes for the application of sensing neurotransmitters
-
Tseng, T.T.-C.; Yao, J.; Chan, W.-C. Selective enzyme immobilization on arrayed microelectrodes for the application of sensing neurotransmitters. Biochem. Eng. J. 2013, 78, 146–153.
-
(2013)
Biochem. Eng. J.
, vol.78
, pp. 146-153
-
-
Tseng, T.T.-C.1
Yao, J.2
Chan, W.-C.3
-
17
-
-
84875746422
-
Engineering the abio-bio interface to enable more than moore in functional bioelectronics
-
Karunwi, O.; Wilson, A.N.; Kotanen, C.N.; Guiseppi-Elie, A. Engineering the abio-bio interface to enable more than moore in functional bioelectronics. J. Electrochem. Soc. 2013, 160, B60–B65.
-
(2013)
J. Electrochem. Soc.
, vol.160
, pp. B60-B65
-
-
Karunwi, O.1
Wilson, A.N.2
Kotanen, C.N.3
Guiseppi-Elie, A.4
-
18
-
-
80052799298
-
Amperometric tyrosinase based biosensor using an electropolymerized phosphate-doped polypyrrole film as an immobilization support. Application for detection of phenolic compounds
-
Apetrei, C.; Rodríguez-Méndez, M.L.; De Saja, J.A. Amperometric tyrosinase based biosensor using an electropolymerized phosphate-doped polypyrrole film as an immobilization support. Application for detection of phenolic compounds. Electrochimica Acta 2011, 56, 8919–8925.
-
(2011)
Electrochimica Acta
, vol.56
, pp. 8919-8925
-
-
Apetrei, C.1
Rodríguez-Méndez, M.L.2
de Saja, J.A.3
-
19
-
-
0034157849
-
Amperometric biosensors based on electrosynthesised polymeric films
-
Palmisano, F.; Zambonin, P.G.; Centonze, D. Amperometric biosensors based on electrosynthesised polymeric films. Fresenius J. Anal. Chem. 2000, 366, 586–601.
-
(2000)
Fresenius J. Anal. Chem.
, vol.366
, pp. 586-601
-
-
Palmisano, F.1
Zambonin, P.G.2
Centonze, D.3
-
21
-
-
84885549231
-
Biosensors based on electrically conducting polymers
-
3rd ed; Skotheim, T., Reynolds, J.R., Eds.; Taylor and Francis: New York, NY, USA
-
Guiseppi-Elie, A.; Brahim, S.; Wilson, A.M. Biosensors based on electrically conducting polymers. In Handbook of Conducting Polymers: Conjugated Polymer Processing and Applications, 3rd ed; Skotheim, T., Reynolds, J.R., Eds.; Taylor and Francis: New York, NY, USA, 2007; Volume 2, pp. 12:11–12:45.
-
(2007)
Handbook of Conducting Polymers: Conjugated Polymer Processing and Applications
, vol.2
-
-
Guiseppi-Elie, A.1
Brahim, S.2
Wilson, A.M.3
-
22
-
-
0033620585
-
Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review
-
Cosnier, S. Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review. Biosens. Bioelectron. 1999, 14, 443–456.
-
(1999)
Biosens. Bioelectron.
, vol.14
, pp. 443-456
-
-
Cosnier, S.1
-
23
-
-
0036671946
-
Influence of film thickness on charge transport of electrodeposited polypyrrole thin films
-
Valaski, R.; Ayoub, S.; Micaroni, L.; Hümmelgen, I. Influence of film thickness on charge transport of electrodeposited polypyrrole thin films. Thin Solid Films 2002, 415, 206–210.
-
(2002)
Thin Solid Films
, vol.415
, pp. 206-210
-
-
Valaski, R.1
Ayoub, S.2
Micaroni, L.3
Hümmelgen, I.4
-
24
-
-
0008428530
-
Dependence of the electrochemical behavior of poly(N-phenylpyrrole) films on the type of anion and solvent used in the electropolymerization
-
Lee, H.; Yang, H.; Kwak, J. Dependence of the electrochemical behavior of poly(N-phenylpyrrole) films on the type of anion and solvent used in the electropolymerization. J. Phys. Chem. B 1999, 103, 6030–6035.
-
(1999)
J. Phys. Chem. B
, vol.103
, pp. 6030-6035
-
-
Lee, H.1
Yang, H.2
Kwak, J.3
-
25
-
-
0036179526
-
Effects of dopant anions and N-substituents on the electrochemical behavior of polypyrrole films in propylene carbonate solution
-
Lee, H.; Yang, H.; Kwak, J. Effects of dopant anions and N-substituents on the electrochemical behavior of polypyrrole films in propylene carbonate solution. Electrochem. Comm. 2002, 4, 128–133.
-
(2002)
Electrochem. Comm.
, vol.4
, pp. 128-133
-
-
Lee, H.1
Yang, H.2
Kwak, J.3
-
26
-
-
84865053753
-
Implantable microprobe with arrayed microsensors for combined amperometric monitoring of the neurotransmitters, glutamate and dopamine
-
Tseng, T.T.-C.; Monbouquette, H.G. Implantable microprobe with arrayed microsensors for combined amperometric monitoring of the neurotransmitters, glutamate and dopamine. J. Electroanal. Chem. 2012, 682, 141–146.
-
(2012)
J. Electroanal. Chem.
, vol.682
, pp. 141-146
-
-
Tseng, T.T.-C.1
Monbouquette, H.G.2
-
27
-
-
84856753237
-
Development of an implantable biosensor system of physiological status monitoring during long duration space exploration
-
Kotanen, C.; Guiseppi-Elie, A. Development of an implantable biosensor system of physiological status monitoring during long duration space exploration. Gravit. Space Biol. 2011, 23, 55–64.
-
(2011)
Gravit. Space Biol.
, vol.23
, pp. 55-64
-
-
Kotanen, C.1
Guiseppi-Elie, A.2
-
28
-
-
0023844606
-
Preparation and electrocatalytic properties of conducting films of polypyrrole containing platinum microparticulates
-
Holdcroft, S.; Funt, B.L. Preparation and electrocatalytic properties of conducting films of polypyrrole containing platinum microparticulates. J. Electroanal. Chem. Interfacial Electrochem. 1988, 240, 89–103.
-
(1988)
J. Electroanal. Chem. Interfacial Electrochem.
, vol.240
, pp. 89-103
-
-
Holdcroft, S.1
Funt, B.L.2
-
29
-
-
19944398419
-
Fabrication and biocompatibility of polypyrrole implants suitable for neural prosthetics
-
George, P.M.; Lyckman, A.W.; LaVan, D.A.; Hegde, A.; Leung, Y.; Avasare, R.; Testa, C.; Alexander, P.M.; Langer, R.; Sur, M. Fabrication and biocompatibility of polypyrrole implants suitable for neural prosthetics. Biomaterials 2005, 26, 3511–3519.
-
(2005)
Biomaterials
, vol.26
, pp. 3511-3519
-
-
George, P.M.1
Lyckman, A.W.2
Lavan, D.A.3
Hegde, A.4
Leung, Y.5
Avasare, R.6
Testa, C.7
Alexander, P.M.8
Langer, R.9
Sur, M.10
-
30
-
-
1342344094
-
Evaluation of biocompatibility of polypyrrole in vitro and in vivo
-
Wang, X.; Gu, X.; Yuan, C.; Chen, S.; Zhang, P.; Zhang, T.; Yao, J.; Chen, F.; Chen, G. Evaluation of biocompatibility of polypyrrole in vitro and in vivo. J. Biomed. Mater. Res. A 2004, 68A, 411–422.
-
(2004)
J. Biomed. Mater. Res. A
, vol.68A
, pp. 411-422
-
-
Wang, X.1
Gu, X.2
Yuan, C.3
Chen, S.4
Zhang, P.5
Zhang, T.6
Yao, J.7
Chen, F.8
Chen, G.9
-
31
-
-
33846829775
-
Biocompatibility of polypyrrole particles: An in vivo study in mice
-
Ramanaviciene, A.; Kausaite, A.; Tautkus, S.; Ramanavicius, A. Biocompatibility of polypyrrole particles: An in vivo study in mice. J. Pharm. Pharmacol. 2007, 59, 311–315.
-
(2007)
J. Pharm. Pharmacol.
, vol.59
, pp. 311-315
-
-
Ramanaviciene, A.1
Kausaite, A.2
Tautkus, S.3
Ramanavicius, A.4
-
32
-
-
0029777091
-
Surface modification of electroactive polymer films by ozone treatment
-
Kang, E.; Neoh, K.; Zhang, X.; Tan, K.; Liaw, D. Surface modification of electroactive polymer films by ozone treatment. Surf. Interface Anal. 1996, 24, 51–58.
-
(1996)
Surf. Interface Anal.
, vol.24
, pp. 51-58
-
-
Kang, E.1
Neoh, K.2
Zhang, X.3
Tan, K.4
Liaw, D.5
-
33
-
-
34250862636
-
Polymer surface modification for the attachment of bioactive compounds
-
Goddard, J.M.; Hotchkiss, J. Polymer surface modification for the attachment of bioactive compounds. Progr. Polymer Sci. 2007, 32, 698–725.
-
(2007)
Progr. Polymer Sci.
, vol.32
, pp. 698-725
-
-
Goddard, J.M.1
Hotchkiss, J.2
-
34
-
-
84865379675
-
Bioactive electroconductive hydrogels yield novel biotransducers for glucose
-
Kotanen, C.N.; Guiseppi-Elie, A. Bioactive electroconductive hydrogels yield novel biotransducers for glucose. Macromol. Symp. 2012, 317–318, 187–197.
-
(2012)
Macromol. Symp.
, vol.317-318
, pp. 187-197
-
-
Kotanen, C.N.1
Guiseppi-Elie, A.2
-
35
-
-
84858750733
-
Bioactive electroconductive hydrogels: The effects of electropolymerization charge density on the storage stability of an enzyme-based biosensor
-
Kotanen, C.N.; Tlili, C.; Guiseppi-Elie, A. Bioactive electroconductive hydrogels: The effects of electropolymerization charge density on the storage stability of an enzyme-based biosensor. Appl. Biochem. Biotechnol. 2012, 166, 878–888.
-
(2012)
Appl. Biochem. Biotechnol.
, vol.166
, pp. 878-888
-
-
Kotanen, C.N.1
Tlili, C.2
Guiseppi-Elie, A.3
-
36
-
-
75249089392
-
Electroconductive hydrogels: Synthesis, characterization and biomedical applications
-
Guiseppi-Elie, A. Electroconductive hydrogels: Synthesis, characterization and biomedical applications. Biomaterials 2010, 31, 2701–2716.
-
(2010)
Biomaterials
, vol.31
, pp. 2701-2716
-
-
Guiseppi-Elie, A.1
-
37
-
-
84860561015
-
Implantable enzyme amperometric biosensors
-
Kotanen, C.N.; Moussy, F.G.; Carrara, S.; Guiseppi-Elie, A. Implantable enzyme amperometric biosensors. Biosens. Bioelectron. 2012, 35, 14–26.
-
(2012)
Biosens. Bioelectron.
, vol.35
, pp. 14-26
-
-
Kotanen, C.N.1
Moussy, F.G.2
Carrara, S.3
Guiseppi-Elie, A.4
-
38
-
-
84878470946
-
Amperometric glucose biosensor based on electroconductive hydrogels
-
Kotanen, C.N.; Tlili, C.; Guiseppi-Elie, A. Amperometric glucose biosensor based on electroconductive hydrogels. Talanta 2013, 103, 228–235.
-
(2013)
Talanta
, vol.103
, pp. 228-235
-
-
Kotanen, C.N.1
Tlili, C.2
Guiseppi-Elie, A.3
-
39
-
-
0034325046
-
Simultaneous monitoring of glucose and lactate by an interference and cross-talk free dual electrode amperometric biosensor based on electropolymerized thin films
-
Palmisano, F.; Rizzi, R.; Centonze, D.; Zambonin, P.G. Simultaneous monitoring of glucose and lactate by an interference and cross-talk free dual electrode amperometric biosensor based on electropolymerized thin films. Biosens. Bioelectron. 2000, 15, 531–539.
-
(2000)
Biosens. Bioelectron.
, vol.15
, pp. 531-539
-
-
Palmisano, F.1
Rizzi, R.2
Centonze, D.3
Zambonin, P.G.4
-
40
-
-
0000948232
-
Specific immobilization of electropolymerized polypyrrole thin films onto interdigitated microsensor electrode arrays
-
Guiseppi-Elie, A.; Wilson, A.M.; Tour, J.M.; Brockmann, T.W.; Zhang, P.; Allara, D.L. Specific immobilization of electropolymerized polypyrrole thin films onto interdigitated microsensor electrode arrays. Langmuir 1995, 11, 1768–1776.
-
(1995)
Langmuir
, vol.11
, pp. 1768-1776
-
-
Guiseppi-Elie, A.1
Wilson, A.M.2
Tour, J.M.3
Brockmann, T.W.4
Zhang, P.5
Allara, D.L.6
-
41
-
-
19944414322
-
Design of a subcutaneous implantable biochip for monitoring of glucose and lactate
-
Guiseppi-Elie, A.; Brahim, S.; Slaughter, G.; Ward, K. Design of a subcutaneous implantable biochip for monitoring of glucose and lactate. IEEE Sens. J. 2005, 5, 345–355.
-
(2005)
IEEE Sens. J.
, vol.5
, pp. 345-355
-
-
Guiseppi-Elie, A.1
Brahim, S.2
Slaughter, G.3
Ward, K.4
-
42
-
-
59949095989
-
Towards an implantable biochip for glucose and lactate monitoring using micro-disc electrode arrays (MDEAs)
-
Rahman, A.R.A.; Justin, G.; Guiseppi-Elie, A. Towards an implantable biochip for glucose and lactate monitoring using micro-disc electrode arrays (MDEAs). Biomed. Microdevices 2009, 11, 75–85.
-
(2009)
Biomed. Microdevices
, vol.11
, pp. 75-85
-
-
Rahman, A.R.A.1
Justin, G.2
Guiseppi-Elie, A.3
-
43
-
-
0034004142
-
Interstitial glucose concentration and glycemia: Implications for continuous subcutaneous glucose monitoring
-
Aussedat, B.; Dupire-Angel, M.; Gifford, R.; Klein, J.C.; Wilson, G.S.; Reach, G. Interstitial glucose concentration and glycemia: Implications for continuous subcutaneous glucose monitoring. Am. J. Physiol. Endocrinol. Metabol. 2000, 278, E716–E728.
-
(2000)
Am. J. Physiol. Endocrinol. Metabol.
, vol.278
, pp. E716-E728
-
-
Aussedat, B.1
Dupire-Angel, M.2
Gifford, R.3
Klein, J.C.4
Wilson, G.S.5
Reach, G.6
-
44
-
-
84987566723
-
Use of polymer films in amperometric biosensors
-
Emr, S.A.; Yacynych, A.M. Use of polymer films in amperometric biosensors. Electroanalysis 2005, 7, 913–923.
-
(2005)
Electroanalysis
, vol.7
, pp. 913-923
-
-
Emr, S.A.1
Yacynych, A.M.2
-
45
-
-
0026147814
-
Characterization of the biochemical behavior of glucose oxidase entrapped in a polypyrrole film
-
Fortier, G.; Belanger, D. Characterization of the biochemical behavior of glucose oxidase entrapped in a polypyrrole film. Biotechnol. Bioeng. 2004, 37, 854–858.
-
(2004)
Biotechnol. Bioeng.
, vol.37
, pp. 854-858
-
-
Fortier, G.1
Belanger, D.2
-
46
-
-
79451473982
-
An implantable biochip to influence patient outcomes following trauma-induced hemorrhage
-
Guiseppi-Elie, A. An implantable biochip to influence patient outcomes following trauma-induced hemorrhage. Anal. Bioanal. Chem. 2011, 399, 403–419.
-
(2011)
Anal. Bioanal. Chem.
, vol.399
, pp. 403-419
-
-
Guiseppi-Elie, A.1
-
47
-
-
78650601510
-
The effect of temperature on the impedimetric response of bioreceptor hosting hydrogels
-
Guiseppi-Elie, A.; Koch, L.; Finley, S.H.; Wnek, G.E. The effect of temperature on the impedimetric response of bioreceptor hosting hydrogels. Biosens. Bioelectron. 2011, 26, 2275–2280.
-
(2011)
Biosens. Bioelectron.
, vol.26
, pp. 2275-2280
-
-
Guiseppi-Elie, A.1
Koch, L.2
Finley, S.H.3
Wnek, G.E.4
-
48
-
-
0023356013
-
Synthesis and properties of vinyl monomer/enzyme conjugates. Conjugation of L-asparaginase with N-succinimidyl acrylate
-
Shoemaker, S.G.; Hoffman, A.S.; Priest, J.H. Synthesis and properties of vinyl monomer/enzyme conjugates. Conjugation of L-asparaginase with N-succinimidyl acrylate. Appl. Biochem. Biotechnol. 1987, 15, 11–24.
-
(1987)
Appl. Biochem. Biotechnol.
, vol.15
, pp. 11-24
-
-
Shoemaker, S.G.1
Hoffman, A.S.2
Priest, J.H.3
-
49
-
-
11944250028
-
Covalent electropolymerization of glucose oxidase in polypyrrole
-
Wolowacz, S.E.; Yon Hin, B.F.Y.; Lowe, C.R. Covalent electropolymerization of glucose oxidase in polypyrrole. Anal. Chem. 1992, 64, 1541–1545.
-
(1992)
Anal. Chem.
, vol.64
, pp. 1541-1545
-
-
Wolowacz, S.E.1
Yon Hin, B.F.Y.2
Lowe, C.R.3
-
50
-
-
33751072399
-
Rajesh. Biomolecular immobilization on conducting polymers for biosensing applications
-
Ahuja, T.; Mir, I.A.; Kumar, D.; Rajesh. Biomolecular immobilization on conducting polymers for biosensing applications. Biomaterials 2007, 28, 791–805.
-
(2007)
Biomaterials
, vol.28
, pp. 791-805
-
-
Ahuja, T.1
Mir, I.A.2
Kumar, D.3
-
51
-
-
0000200816
-
Covalent electropolymerization of glucose oxidase in polypyrrole. Evaluation of methods of pyrrole attachment to glucose oxidase on the performance of electropolymerized glucose sensors
-
Yon-Hin, B.F.Y.; Smolander, M.; Crompton, T.; Lowe, C.R. Covalent electropolymerization of glucose oxidase in polypyrrole. Evaluation of methods of pyrrole attachment to glucose oxidase on the performance of electropolymerized glucose sensors. Anal. Chem. 1993, 65, 2067–2071.
-
(1993)
Anal. Chem.
, vol.65
, pp. 2067-2071
-
-
Yon-Hin, B.F.Y.1
Smolander, M.2
Crompton, T.3
Lowe, C.R.4
-
52
-
-
77956936185
-
Pyrrole-hyaluronic acid conjugates for decreasing cell binding to metals and conducting polymers
-
Lee, J.Y.; Schmidt, C.E. Pyrrole-hyaluronic acid conjugates for decreasing cell binding to metals and conducting polymers. Acta Biomaterialia 2010, 6, 4396–4404.
-
(2010)
Acta Biomaterialia
, vol.6
, pp. 4396-4404
-
-
Lee, J.Y.1
Schmidt, C.E.2
-
53
-
-
84865159660
-
Microfabrication of proangiogenic cell-Laden alginate-g-Pyrrole hydrogels
-
DeVolder, R.J.; Zill, A.T.; Jeong, J.H.; Kong, H. Microfabrication of proangiogenic cell-Laden alginate-g-Pyrrole hydrogels. Biomaterials 2012, 33, 7718–7726.
-
(2012)
Biomaterials
, vol.33
, pp. 7718-7726
-
-
Devolder, R.J.1
Zill, A.T.2
Jeong, J.H.3
Kong, H.4
-
54
-
-
0038094492
-
A glucose oxidase electrode based on polypyrrole with polyanion/PEG/enzyme conjugate dopant
-
Sung, W.J.; Bae, Y.H. A glucose oxidase electrode based on polypyrrole with polyanion/PEG/enzyme conjugate dopant. Biosens. Bioelectron. 2003, 18, 1231–1239.
-
(2003)
Biosens. Bioelectron.
, vol.18
, pp. 1231-1239
-
-
Sung, W.J.1
Bae, Y.H.2
-
55
-
-
33244483029
-
Glucose oxidase, lactate oxidase, and galactose oxidase enzyme electrode based on polypyrrole with polyanion/PEG/enzyme conjugate dopant
-
Sung, W.J.; Bae, Y.H. Glucose oxidase, lactate oxidase, and galactose oxidase enzyme electrode based on polypyrrole with polyanion/PEG/enzyme conjugate dopant. Sens. Actuator B Chem. 2006, 114, 164–169.
-
(2006)
Sens. Actuator B Chem.
, vol.114
, pp. 164-169
-
-
Sung, W.J.1
Bae, Y.H.2
-
56
-
-
0030887676
-
Detection of haloacetic acids at conductive electroactive polymer-modified microelectrodes
-
Akhtar, P.; Too, C.; Wallace, G.G. Detection of haloacetic acids at conductive electroactive polymer-modified microelectrodes. Anal. Chim. Acta 1997, 341, 141–153.
-
(1997)
Anal. Chim. Acta
, vol.341
, pp. 141-153
-
-
Akhtar, P.1
Too, C.2
Wallace, G.G.3
-
57
-
-
0021412692
-
Ferrocene-mediated enzyme electrode for amperometric determination of glucose
-
Cass, A.E.; Davis, G.; Francis, G.D.; Hill, H.A.O.; Aston, W.J.; Higgins, I.J.; Plotkin, E.V.; Scott, L.D.; Turner, A.P. Ferrocene-mediated enzyme electrode for amperometric determination of glucose. Anal. Chem. 1984, 56, 667–671.
-
(1984)
Anal. Chem.
, vol.56
, pp. 667-671
-
-
Cass, A.E.1
Davis, G.2
Francis, G.D.3
Hill, H.A.O.4
Aston, W.J.5
Higgins, I.J.6
Plotkin, E.V.7
Scott, L.D.8
Turner, A.P.9
-
58
-
-
0034194368
-
A glucose oxidase electrode based on electropolymerized conducting polymer with polyanion-enzyme conjugated dopant
-
Sung, W.J.; Bae, Y.H. A glucose oxidase electrode based on electropolymerized conducting polymer with polyanion-enzyme conjugated dopant. Anal. Chem. 2000, 72, 2177–2181.
-
(2000)
Anal. Chem.
, vol.72
, pp. 2177-2181
-
-
Sung, W.J.1
Bae, Y.H.2
-
59
-
-
0000200816
-
Covalent electropolymerization of glucose oxidase in polypyrrole. Evaluation of methods of pyrrole attachment to glucose oxidase on the performance of electropolymerized glucose sensors
-
Yon-Hin, B.F.; Smolander, M.; Crompton, T.; Lowe, C.R. Covalent electropolymerization of glucose oxidase in polypyrrole. Evaluation of methods of pyrrole attachment to glucose oxidase on the performance of electropolymerized glucose sensors. Anal. Chem. 1993, 65, 2067–2071.
-
(1993)
Anal. Chem.
, vol.65
, pp. 2067-2071
-
-
Yon-Hin, B.F.1
Smolander, M.2
Crompton, T.3
Lowe, C.R.4
-
60
-
-
0042973715
-
An investigation of 3-functionalized pyrrole-modified glucose oxidase for the covalent electropolymerization of enzyme films
-
Yon-Hin, B.; Lowe, C. An investigation of 3-functionalized pyrrole-modified glucose oxidase for the covalent electropolymerization of enzyme films. J. Electroanal. Chem. 1994, 374, 167–172.
-
(1994)
J. Electroanal. Chem.
, vol.374
, pp. 167-172
-
-
Yon-Hin, B.1
Lowe, C.2
-
61
-
-
84861561386
-
Polypyrrole (PPy) Nanowire Arrays Entrapped with Glucose Oxidase Biosensor for Glucose Detection
-
Kyoto, Japan, 5–8 March
-
Xu, G.; Lv, J.; Zheng, Z.; Wu, Y. Polypyrrole (PPy) Nanowire Arrays Entrapped with Glucose Oxidase Biosensor for Glucose Detection. In Proceedings of the 7th IEEE International Conference on of Nano/Micro Engineered and Molecular Systems (NEMS), Kyoto, Japan, 5–8 March 2012; pp. 511–514.
-
(2012)
Proceedings of the 7Th IEEE International Conference on of Nano/Micro Engineered and Molecular Systems (NEMS)
, pp. 511-514
-
-
Xu, G.1
Lv, J.2
Zheng, Z.3
Wu, Y.4
-
62
-
-
14844334140
-
Molecularly engineered p(HEMA)-based hydrogels for implant biochip biocompatibility
-
Abraham, S.; Brahim, S.; Ishihara, K.; Guiseppi-Elie, A. Molecularly engineered p(HEMA)-based hydrogels for implant biochip biocompatibility. Biomaterials 2005, 26, 4767–4778.
-
(2005)
Biomaterials
, vol.26
, pp. 4767-4778
-
-
Abraham, S.1
Brahim, S.2
Ishihara, K.3
Guiseppi-Elie, A.4
-
63
-
-
33646079187
-
A long-term flexible minimally-invasive implantable glucose biosensor based on an epoxy-enhanced polyurethane membrane
-
Yu, B.; Long, N.; Moussy, Y.; Moussy, F. A long-term flexible minimally-invasive implantable glucose biosensor based on an epoxy-enhanced polyurethane membrane. Biosens. Bioelectron. 2006, 21, 2275–2282.
-
(2006)
Biosens. Bioelectron.
, vol.21
, pp. 2275-2282
-
-
Yu, B.1
Long, N.2
Moussy, Y.3
Moussy, F.4
-
64
-
-
33749255321
-
Electrodeposition of polypyrrole-multiwalled carbon nanotube-glucose oxidase nanobiocomposite film for the detection of glucose
-
Tsai, Y.-C.; Li, S.-C.; Liao, S.-W. Electrodeposition of polypyrrole-multiwalled carbon nanotube-glucose oxidase nanobiocomposite film for the detection of glucose. Biosens. Bioelectron. 2006, 22, 495–500.
-
(2006)
Biosens. Bioelectron.
, vol.22
, pp. 495-500
-
-
Tsai, Y.-C.1
Li, S.-C.2
Liao, S.-W.3
-
65
-
-
34248525070
-
Glucose biosensor based on immobilization of glucose oxidase in poly(O-aminophenol) film on polypyrrole-Pt nanocomposite modified glassy carbon electrode
-
Li, J.; Lin, X. Glucose biosensor based on immobilization of glucose oxidase in poly(o-aminophenol) film on polypyrrole-Pt nanocomposite modified glassy carbon electrode. Biosens. Bioelectron. 2007, 22, 2898–2905.
-
(2007)
Biosens. Bioelectron.
, vol.22
, pp. 2898-2905
-
-
Li, J.1
Lin, X.2
-
66
-
-
63749111814
-
An amperometric glucose biosensor based on the immobilization of glucose oxidase on the ZnO nanotubes
-
Kong, T.; Chen, Y.; Ye, Y.; Zhang, K.; Wang, Z.; Wang, X. An amperometric glucose biosensor based on the immobilization of glucose oxidase on the ZnO nanotubes. Sens. Actuator B Chem. 2009, 138, 344–350.
-
(2009)
Sens. Actuator B Chem.
, vol.138
, pp. 344-350
-
-
Kong, T.1
Chen, Y.2
Ye, Y.3
Zhang, K.4
Wang, Z.5
Wang, X.6
-
67
-
-
84867098967
-
Glucose biosensor based on glucose oxidase and gold nanoparticles of different sizes covered by polypyrrole layer
-
German, N.; Ramanavicius, A.; Voronovic, J.; Ramanaviciene, A. Glucose biosensor based on glucose oxidase and gold nanoparticles of different sizes covered by polypyrrole layer. Colloid Surface Physicochem. Eng. Aspect 2012, 413, 224–230.
-
(2012)
Colloid Surface Physicochem. Eng. Aspect
, vol.413
, pp. 224-230
-
-
German, N.1
Ramanavicius, A.2
Voronovic, J.3
Ramanaviciene, A.4
-
68
-
-
18344396429
-
Carbon-nanotubes doped polypyrrole glucose biosensor
-
Wang, J.; Musameh, M. Carbon-nanotubes doped polypyrrole glucose biosensor. Anal. Chim. Acta 2005, 539, 209–213.
-
(2005)
Anal. Chim. Acta
, vol.539
, pp. 209-213
-
-
Wang, J.1
Musameh, M.2
-
69
-
-
0001606727
-
Electrochemically synthesized polypyrrole nanotubules: Effects of different experimental conditions
-
Demoustier-Champagne, S.; Ferain, E.; Jérôme, C.; Jérôme, R.; Legras, R. Electrochemically synthesized polypyrrole nanotubules: effects of different experimental conditions. Eur. Polymer J. 1998, 34, 1767–1774.
-
(1998)
Eur. Polymer J.
, vol.34
, pp. 1767-1774
-
-
Demoustier-Champagne, S.1
Ferain, E.2
Jérôme, C.3
Jérôme, R.4
Legras, R.5
-
70
-
-
0029289599
-
Chemically oxidized polypyrrole: Influence of the experimental conditions on its electrical conductivity and morphology
-
Chen, X.; Issi, J.P.; Devaux, J.; Billaud, D. Chemically oxidized polypyrrole: Influence of the experimental conditions on its electrical conductivity and morphology. Polymer Eng. Sci. 1995, 35, 642–647.
-
(1995)
Polymer Eng. Sci.
, vol.35
, pp. 642-647
-
-
Chen, X.1
Issi, J.P.2
Devaux, J.3
Billaud, D.4
-
71
-
-
84892217144
-
Lactic acidosis and hyperlactatemia
-
Vincent, J.-L., Ed.; Springer: Berlin/Heidelberg, Germany
-
Levy, B. Lactic acidosis and hyperlactatemia. In Yearbook of Intensive Care and Emergency Medicine; Vincent, J.-L., Ed.; Springer: Berlin/Heidelberg, Germany, 2006; Volume 2006, pp. 88–98.
-
(2006)
Yearbook of Intensive Care and Emergency Medicine
, vol.2006
, pp. 88-98
-
-
Levy, B.1
-
72
-
-
67651046991
-
Serum lactate and base deficit as predictors of mortality in normotensive elderly blunt trauma patients
-
Callaway, D.W.; Shapiro, N.I.; Donnino, M.W.; Baker, C.; Rosen, C.L. Serum lactate and base deficit as predictors of mortality in normotensive elderly blunt trauma patients. J. Trauma 2009, 66, 1040–1044.
-
(2009)
J. Trauma
, vol.66
, pp. 1040-1044
-
-
Callaway, D.W.1
Shapiro, N.I.2
Donnino, M.W.3
Baker, C.4
Rosen, C.L.5
-
74
-
-
18044367556
-
Biosensors for real-time in vivo measurements
-
Wilson, G.S.; Gifford, R. Biosensors for real-time in vivo measurements. Biosens. Bioelectron. 2005, 20, 2388–2403.
-
(2005)
Biosens. Bioelectron.
, vol.20
, pp. 2388-2403
-
-
Wilson, G.S.1
Gifford, R.2
-
75
-
-
0032999480
-
In vivo glucose monitoring with open microflow-influences of fluid composition and preliminary evaluation in man
-
Rigby, G.; Ahmed, S.; Horseman, G.; Vadgama, P. In vivo glucose monitoring with open microflow-influences of fluid composition and preliminary evaluation in man. Anal. Chim. Acta 1999, 385, 23–32.
-
(1999)
Anal. Chim. Acta
, vol.385
, pp. 23-32
-
-
Rigby, G.1
Ahmed, S.2
Horseman, G.3
Vadgama, P.4
-
76
-
-
0033765196
-
In vitro and in vivo degradation of glucose oxidase enzyme used for an implantable glucose biosensor
-
Valdes, T.; Moussy, F. In vitro and in vivo degradation of glucose oxidase enzyme used for an implantable glucose biosensor. Diabetes Tech. Therapeut. 2000, 2, 367–376.
-
(2000)
Diabetes Tech. Therapeut.
, vol.2
, pp. 367-376
-
-
Valdes, T.1
Moussy, F.2
-
77
-
-
0043025558
-
Physiological differences between interstitial glucose and blood glucose measured in human subjects
-
Kulcu, E.; Tamada, J.A.; Reach, G.; Potts, R.O.; Lesho, M.J. Physiological differences between interstitial glucose and blood glucose measured in human subjects. Diabetes Care 2003, 26, 2405–2409.
-
(2003)
Diabetes Care
, vol.26
, pp. 2405-2409
-
-
Kulcu, E.1
Tamada, J.A.2
Reach, G.3
Potts, R.O.4
Lesho, M.J.5
-
78
-
-
0031892091
-
Measurement and modeling of the transient difference between blood and subcutaneous glucose concentrations in the rat after injection of insulin
-
Schmidtke, D.W.; Freeland, A.C.; Heller, A.; Bonnecaze, R.T. Measurement and modeling of the transient difference between blood and subcutaneous glucose concentrations in the rat after injection of insulin. PNAS 1998, 95, 294–299.
-
(1998)
PNAS
, vol.95
, pp. 294-299
-
-
Schmidtke, D.W.1
Freeland, A.C.2
Heller, A.3
Bonnecaze, R.T.4
-
79
-
-
34249800911
-
In vitro, in vivo and post explantation testing of glucose-detecting biosensors: Current methods and recommendations
-
Koschwanez, H.E.; Reichert, W.M. In vitro, in vivo and post explantation testing of glucose-detecting biosensors: Current methods and recommendations. Biomaterials 2007, 28, 3687–3703.
-
(2007)
Biomaterials
, vol.28
, pp. 3687-3703
-
-
Koschwanez, H.E.1
Reichert, W.M.2
-
80
-
-
0028413636
-
Enzymatic glucose sensors: Improved long-term performance in vitro and in vivo
-
Updike, S.J.; Shults, M.C.; Rhodes, R.K.; Gilligan, B.J.; Luebow, J.O.; von Heimburg, D. Enzymatic glucose sensors: Improved long-term performance in vitro and in vivo. ASAIO J. 1994, 40, 157–163.
-
(1994)
ASAIO J
, vol.40
, pp. 157-163
-
-
Updike, S.J.1
Shults, M.C.2
Rhodes, R.K.3
Gilligan, B.J.4
Luebow, J.O.5
von Heimburg, D.6
-
81
-
-
0025689061
-
Application of chronic intravascular blood glucose sensor in dogs
-
Armour, J.C.; Lucisano, J.Y.; McKean, B.D.; Gough, D.A. Application of chronic intravascular blood glucose sensor in dogs. Diabetes 1990, 39, 1519–1526.
-
(1990)
Diabetes
, vol.39
, pp. 1519-1526
-
-
Armour, J.C.1
Lucisano, J.Y.2
McKean, B.D.3
Gough, D.A.4
-
82
-
-
78649344157
-
Continuous glucose monitoring in subjects with type 1 diabetes: Improvement in accuracy by correcting for background current
-
Youssef, J.E.; Castle, J.R.; Engle, J.M.; Massoud, R.G.; Ward, W.K. Continuous glucose monitoring in subjects with type 1 diabetes: Improvement in accuracy by correcting for background current. Diabetes Tech. Therapeut. 2010, 12, 921–928.
-
(2010)
Diabetes Tech. Therapeut.
, vol.12
, pp. 921-928
-
-
Youssef, J.E.1
Castle, J.R.2
Engle, J.M.3
Massoud, R.G.4
Ward, W.K.5
-
83
-
-
0242403064
-
In vivo calibration of the subcutaneous amperometric glucose sensors using a non-enzyme electrode
-
Jeong, R.-A.; Hwang, J.Y.; Joo, S.; Chung, T.D.; Park, S.; Kang, S.K.; Lee, W.-Y.; Kim, H.C. In vivo calibration of the subcutaneous amperometric glucose sensors using a non-enzyme electrode. Biosens. Bioelectron. 2003, 19, 313–319.
-
(2003)
Biosens. Bioelectron.
, vol.19
, pp. 313-319
-
-
Jeong, R.-A.1
Hwang, J.Y.2
Joo, S.3
Chung, T.D.4
Park, S.5
Kang, S.K.6
Lee, W.-Y.7
Kim, H.C.8
|