메뉴 건너뛰기




Volumn 116, Issue 3, 2016, Pages 362-367

Comparison of marginal and internal fit of 3-unit ceramic fixed dental prostheses made with either a conventional or digital impression

Author keywords

[No Author keywords available]

Indexed keywords

CERAMICS; COMPARATIVE STUDY; COMPUTER AIDED DESIGN; DENTAL IMPRESSION; DENTAL MARGINAL ADAPTATION; DEVICES; HUMAN; IN VITRO STUDY; PROCEDURES; PROSTHESIS DESIGN; THERAPEUTIC USE;

EID: 84962688228     PISSN: 00223913     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.prosdent.2016.01.018     Document Type: Article
Times cited : (75)

References (35)
  • 1
    • 33749241323 scopus 로고    scopus 로고
    • The evolution of the CEREC system
    • 1 Mörmann, W.H., The evolution of the CEREC system. J Am Dent Assoc 137:suppl (2006), 7S–13S.
    • (2006) J Am Dent Assoc , vol.137 , pp. 7S-13S
    • Mörmann, W.H.1
  • 2
    • 0037982925 scopus 로고    scopus 로고
    • Design and production of dental prosthetic restorations: basic research on dental CAD/CAM technology
    • 2 Luthardt, R., Weber, A., Rudolph, H., Schöne, C., Quaas, S., Walter, M., Design and production of dental prosthetic restorations: basic research on dental CAD/CAM technology. Int J Comput Dent 5 (2002), 165–176.
    • (2002) Int J Comput Dent , vol.5 , pp. 165-176
    • Luthardt, R.1    Weber, A.2    Rudolph, H.3    Schöne, C.4    Quaas, S.5    Walter, M.6
  • 3
    • 44749095100 scopus 로고    scopus 로고
    • Effect of different retraction and impression techniques on the marginal fit of crowns
    • 3 Wöstmann, B., Rehmann, P., Trost, D., Balkenhol, M., Effect of different retraction and impression techniques on the marginal fit of crowns. J Dent 36 (2008), 508–512.
    • (2008) J Dent , vol.36 , pp. 508-512
    • Wöstmann, B.1    Rehmann, P.2    Trost, D.3    Balkenhol, M.4
  • 4
    • 84942552925 scopus 로고    scopus 로고
    • Comparison of the marginal fit of lithium disilicate crowns fabricated with CAD/CAM technology by using conventional impressions and two intraoral digital scanners
    • 4 Abdel-Azim, T., Rogers, K., Elathamna, E., Zandinejad, A., Metz, M., Morton, D., Comparison of the marginal fit of lithium disilicate crowns fabricated with CAD/CAM technology by using conventional impressions and two intraoral digital scanners. J Prosthet Dent 114 (2015), 554–559.
    • (2015) J Prosthet Dent , vol.114 , pp. 554-559
    • Abdel-Azim, T.1    Rogers, K.2    Elathamna, E.3    Zandinejad, A.4    Metz, M.5    Morton, D.6
  • 5
    • 84940718800 scopus 로고    scopus 로고
    • Digital versus analog complete-arch impressions for single-unit premolar implant crowns: operating time and patient preference
    • 5 Schepke, U., Meijer, H.J., Kerdijk, W., Cune, M.S., Digital versus analog complete-arch impressions for single-unit premolar implant crowns: operating time and patient preference. J Prosthet Dent 114 (2015), 403–406.
    • (2015) J Prosthet Dent , vol.114 , pp. 403-406
    • Schepke, U.1    Meijer, H.J.2    Kerdijk, W.3    Cune, M.S.4
  • 6
    • 84902469715 scopus 로고    scopus 로고
    • Accuracy of ceramic restorations made using an in-office optical scanning technique: an in vitro study
    • 6 Tidehag, P., Ottosson, K., Sjögren, G., Accuracy of ceramic restorations made using an in-office optical scanning technique: an in vitro study. Oper Dent 39 (2014), 308–316.
    • (2014) Oper Dent , vol.39 , pp. 308-316
    • Tidehag, P.1    Ottosson, K.2    Sjögren, G.3
  • 7
    • 84933049111 scopus 로고    scopus 로고
    • Comparison of accuracy and reproducibility of casts made by digital and conventional methods
    • 7 Cho, S.H., Schaefer, O., Thompson, G.A., Guentsch, A., Comparison of accuracy and reproducibility of casts made by digital and conventional methods. J Prosthet Dent 113 (2015), 310–315.
    • (2015) J Prosthet Dent , vol.113 , pp. 310-315
    • Cho, S.H.1    Schaefer, O.2    Thompson, G.A.3    Guentsch, A.4
  • 9
    • 0022139299 scopus 로고
    • The fit of metal-ceramic crowns, a clinical study
    • 9 Fransson, B., Oilo, G., Gjeitanger, R., The fit of metal-ceramic crowns, a clinical study. Dent Mater 1 (1985), 197–199.
    • (1985) Dent Mater , vol.1 , pp. 197-199
    • Fransson, B.1    Oilo, G.2    Gjeitanger, R.3
  • 10
    • 43449084359 scopus 로고    scopus 로고
    • Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures
    • 10 Wettstein, F., Sailer, I., Roos, M., Hammerle, C.H., Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. Eur J Oral Sci 116 (2008), 272–279.
    • (2008) Eur J Oral Sci , vol.116 , pp. 272-279
    • Wettstein, F.1    Sailer, I.2    Roos, M.3    Hammerle, C.H.4
  • 12
    • 77957280346 scopus 로고    scopus 로고
    • Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling
    • 12 Syrek, A., Reich, G., Ranftl, D., Klein, C., Cerny, B., Brodesser, J., Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent 38 (2010), 553–559.
    • (2010) J Dent , vol.38 , pp. 553-559
    • Syrek, A.1    Reich, G.2    Ranftl, D.3    Klein, C.4    Cerny, B.5    Brodesser, J.6
  • 14
    • 84922798743 scopus 로고    scopus 로고
    • Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology
    • 14 Pradíes, G., Zarauz, C., Valverde, A., Ferreiroa, A., Martínez-Rus, F., Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology. J Dent 43 (2015), 201–208.
    • (2015) J Dent , vol.43 , pp. 201-208
    • Pradíes, G.1    Zarauz, C.2    Valverde, A.3    Ferreiroa, A.4    Martínez-Rus, F.5
  • 16
    • 84906810284 scopus 로고    scopus 로고
    • A comparison of the marginal fit of crowns fabricated with digital and conventional methods
    • 16 Ng, J., Ruse, D., Wyatt, C., A comparison of the marginal fit of crowns fabricated with digital and conventional methods. J Prosthet Dent 112 (2014), 555–560.
    • (2014) J Prosthet Dent , vol.112 , pp. 555-560
    • Ng, J.1    Ruse, D.2    Wyatt, C.3
  • 17
    • 33749262810 scopus 로고    scopus 로고
    • Dental CAD/CAM systems: a 20-year success story
    • 17 Rekow, E.D., Dental CAD/CAM systems: a 20-year success story. J Am Dent Assoc 137 (2006), 5S–6S.
    • (2006) J Am Dent Assoc , vol.137 , pp. 5S-6S
    • Rekow, E.D.1
  • 18
    • 84933678682 scopus 로고    scopus 로고
    • Intraoral digital impression technique: a review
    • 18 Ting-Shu, S., Jian, S., Intraoral digital impression technique: a review. J Prosthodont 24 (2015), 313–321.
    • (2015) J Prosthodont , vol.24 , pp. 313-321
    • Ting-Shu, S.1    Jian, S.2
  • 19
    • 0027620312 scopus 로고
    • The fit of Procera titanium crowns. An in vitro and clinical study
    • 19 Karlsson, S., The fit of Procera titanium crowns. An in vitro and clinical study. Acta Odontol Scand 51 (1993), 129–134.
    • (1993) Acta Odontol Scand , vol.51 , pp. 129-134
    • Karlsson, S.1
  • 20
    • 0015209415 scopus 로고
    • The estimation of cement film thickness by an in vivo technique
    • 20 McLean, J.W., von Fraunhofer, J.A., The estimation of cement film thickness by an in vivo technique. Br Dent J 131 (1971), 107–111.
    • (1971) Br Dent J , vol.131 , pp. 107-111
    • McLean, J.W.1    von Fraunhofer, J.A.2
  • 21
    • 0021975697 scopus 로고
    • Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study
    • 21 Belser, U.C., MacEntee, M.I., Richter, W.A., Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study. J Prosthet Dent 53 (1985), 24–29.
    • (1985) J Prosthet Dent , vol.53 , pp. 24-29
    • Belser, U.C.1    MacEntee, M.I.2    Richter, W.A.3
  • 22
    • 0031217183 scopus 로고    scopus 로고
    • A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns
    • 22 Sulaiman, F., Chai, J., Jameson, L.M., Wozniak, W.T., A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns. Int J Prosthodont 10 (1997), 478–484.
    • (1997) Int J Prosthodont , vol.10 , pp. 478-484
    • Sulaiman, F.1    Chai, J.2    Jameson, L.M.3    Wozniak, W.T.4
  • 23
    • 84873296444 scopus 로고    scopus 로고
    • Optical impression systems for CAD-CAM restorations
    • 23 Galhano, G.Á., Pellizzer, E.P., Mazaro, J.V., Optical impression systems for CAD-CAM restorations. J Craniofac Surg 23 (2012), 575–579.
    • (2012) J Craniofac Surg , vol.23 , pp. 575-579
    • Galhano, G.Á.1    Pellizzer, E.P.2    Mazaro, J.V.3
  • 24
    • 84894547254 scopus 로고    scopus 로고
    • Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques
    • 24 Almeida, E., Silva, J.S., Erdelt, K., Edelhoff, D., Araújo, E., Stimmelmayr, M., et al. Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig 18 (2014), 515–523.
    • (2014) Clin Oral Investig , vol.18 , pp. 515-523
    • Almeida, E.1    Silva, J.S.2    Erdelt, K.3    Edelhoff, D.4    Araújo, E.5    Stimmelmayr, M.6
  • 25
    • 84933055458 scopus 로고    scopus 로고
    • Internal fit of pressed and computer-aided design/computer-aided manufacturing ceramic crowns made from digital and conventional impressions
    • 25 Anadioti, E., Aquilino, S.A., Gratton, D.G., Holloway, J.A., Denry, I.L., Thomas, G.W., et al. Internal fit of pressed and computer-aided design/computer-aided manufacturing ceramic crowns made from digital and conventional impressions. J Prosthet Dent 113 (2015), 304–309.
    • (2015) J Prosthet Dent , vol.113 , pp. 304-309
    • Anadioti, E.1    Aquilino, S.A.2    Gratton, D.G.3    Holloway, J.A.4    Denry, I.L.5    Thomas, G.W.6
  • 26
    • 84881612097 scopus 로고    scopus 로고
    • Accuracy of digital and conventional impression techniques and workflow
    • 26 Seelbach, P., Brueckel, C., Wöstmann, B., Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig 17 (2013), 1759–1764.
    • (2013) Clin Oral Investig , vol.17 , pp. 1759-1764
    • Seelbach, P.1    Brueckel, C.2    Wöstmann, B.3
  • 27
    • 84897026100 scopus 로고    scopus 로고
    • Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization–a laboratory study
    • 27 Keul, C., Stawarczyk, B., Erdelt, K.J., Beuer, F., Edelhoff, D., Güth, J.F., Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization–a laboratory study. Dent Mater 30 (2014), 400–407.
    • (2014) Dent Mater , vol.30 , pp. 400-407
    • Keul, C.1    Stawarczyk, B.2    Erdelt, K.J.3    Beuer, F.4    Edelhoff, D.5    Güth, J.F.6
  • 28
    • 84888638427 scopus 로고    scopus 로고
    • The clinical accuracy of single crowns exclusively fabricated by digital workflow—the comparison of two systems
    • 28 Brawek, P.K., Wolfart, S., Endres, L., Kirsten, A., Reich, S., The clinical accuracy of single crowns exclusively fabricated by digital workflow—the comparison of two systems. Clin Oral Investig 17 (2013), 2119–2125.
    • (2013) Clin Oral Investig , vol.17 , pp. 2119-2125
    • Brawek, P.K.1    Wolfart, S.2    Endres, L.3    Kirsten, A.4    Reich, S.5
  • 29
    • 84942986932 scopus 로고    scopus 로고
    • Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients
    • 29 Boeddinghaus, M., Breloer, E.S., Rehmann, P., Wöstmann, B., Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients. Clin Oral Investig 19 (2015), 2027–2034.
    • (2015) Clin Oral Investig , vol.19 , pp. 2027-2034
    • Boeddinghaus, M.1    Breloer, E.S.2    Rehmann, P.3    Wöstmann, B.4
  • 30
    • 55549145403 scopus 로고    scopus 로고
    • The effect of several dentin desensitizers on shear bond strength of adhesive resin luting cement using self-etching primer
    • 30 Huh, J.B., Kim, J.H., Chung, M.K., Lee, H.Y., Choi, Y.G., Shim, J.S., The effect of several dentin desensitizers on shear bond strength of adhesive resin luting cement using self-etching primer. J Dent 36 (2008), 1025–1032.
    • (2008) J Dent , vol.36 , pp. 1025-1032
    • Huh, J.B.1    Kim, J.H.2    Chung, M.K.3    Lee, H.Y.4    Choi, Y.G.5    Shim, J.S.6
  • 31
    • 70249122096 scopus 로고    scopus 로고
    • Randomized controlled clinical study on the accuracy of two-stage putty-and-wash impression materials
    • 31 Haim, M., Luthardt, R.G., Rudolph, H., Koch, R., Walter, M.H., Quaas, S., Randomized controlled clinical study on the accuracy of two-stage putty-and-wash impression materials. Int J Prosthodont 22 (2009), 296–302.
    • (2009) Int J Prosthodont , vol.22 , pp. 296-302
    • Haim, M.1    Luthardt, R.G.2    Rudolph, H.3    Koch, R.4    Walter, M.H.5    Quaas, S.6
  • 32
    • 84899431715 scopus 로고    scopus 로고
    • An in vitro study of the bond strength of five adhesives used for vinyl polysiloxane impression materials and tray materials
    • 32 Kumar, S., Gandhi, U.V., Banerjee, S., An in vitro study of the bond strength of five adhesives used for vinyl polysiloxane impression materials and tray materials. J Indian Prosthodont Soc 14 (2014), 61–66.
    • (2014) J Indian Prosthodont Soc , vol.14 , pp. 61-66
    • Kumar, S.1    Gandhi, U.V.2    Banerjee, S.3
  • 33
    • 0032092661 scopus 로고    scopus 로고
    • The effect of temperature changes on the dimensional stability of polyvinyl siloxane and polyether impression materials
    • 33 Corso, M., Abanomy, A., Di Canzio, J., Zurakowski, D., Morgano, S.M., The effect of temperature changes on the dimensional stability of polyvinyl siloxane and polyether impression materials. J Prosthet Dent 79 (1998), 626–631.
    • (1998) J Prosthet Dent , vol.79 , pp. 626-631
    • Corso, M.1    Abanomy, A.2    Di Canzio, J.3    Zurakowski, D.4    Morgano, S.M.5
  • 34
    • 38149014578 scopus 로고    scopus 로고
    • Clinical evaluation of the marginal fit of cast crowns—validation of the silicone replica method
    • 34 Laurent, M., Scheer, P., Dejou, J., Laborde, G., Clinical evaluation of the marginal fit of cast crowns—validation of the silicone replica method. J Oral Rehab 35 (2008), 116–122.
    • (2008) J Oral Rehab , vol.35 , pp. 116-122
    • Laurent, M.1    Scheer, P.2    Dejou, J.3    Laborde, G.4
  • 35
    • 84867400213 scopus 로고    scopus 로고
    • Clinical fitting of CAD/CAM zirconia single crowns generated from digital intraoral impressions based on active wavefront sampling
    • 35 Cardelli, P., Scotti, R., Monaco, C., Clinical fitting of CAD/CAM zirconia single crowns generated from digital intraoral impressions based on active wavefront sampling. J Dent, 17, 2011.
    • (2011) J Dent , vol.17
    • Cardelli, P.1    Scotti, R.2    Monaco, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.