메뉴 건너뛰기




Volumn 85, Issue 8, 2016, Pages 1499-1504

Computed tomography: What and how does it measure?

Author keywords

Computed tomography; Human body compartments; Measurement methods; ody composition

Indexed keywords

ADIPOSE TISSUE; ARTICLE; AUTOMATION; BODY COMPOSITION; BONE DENSITY; CACHEXIA; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; CORTICAL BONE; DIAGNOSTIC ACCURACY; HUMAN; IMAGE PROCESSING; LIPID LIVER LEVEL; LIVER WEIGHT; METABOLIC BONE DISEASE; METABOLIC DISORDER; MULTIDETECTOR COMPUTED TOMOGRAPHY; MUSCLE ATROPHY; ORGAN SIZE; OSTEOPOROSIS; PRIORITY JOURNAL; REPRODUCIBILITY; RESTING ENERGY EXPENDITURE; SARCOPENIA; SKELETAL MUSCLE; SUBCUTANEOUS FAT; TRABECULAR BONE; WHOLE BODY CT; X RAY TUBE; BONE; DIAGNOSTIC IMAGING; PROCEDURES; X-RAY COMPUTED TOMOGRAPHY;

EID: 84961120217     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2016.03.002     Document Type: Article
Times cited : (42)

References (60)
  • 1
    • 0026638094 scopus 로고
    • The five-level model: a new approach to organizing body-composition research
    • [1] Wang, Z.M., Pierson, R.N., Heymsfield, S.B., The five-level model: a new approach to organizing body-composition research. Am. J. Clin. Nutr. 56 (1992), 19–28.
    • (1992) Am. J. Clin. Nutr. , vol.56 , pp. 19-28
    • Wang, Z.M.1    Pierson, R.N.2    Heymsfield, S.B.3
  • 2
    • 33745484882 scopus 로고    scopus 로고
    • Computed tomography and magnetic resonance imaging
    • S.B. Heymsfield T.G. Lohman Z. Wang S.B. Going second ed. Human Kinetics Champaign IL
    • [2] Ross, R., Janssen, I., Computed tomography and magnetic resonance imaging. Heymsfield, S.B., Lohman, T.G., Wang, Z., Going, S.B., (eds.) Human Body Composition, second ed., 2002, Human Kinetics Champaign, IL, 89–108.
    • (2002) Human Body Composition , pp. 89-108
    • Ross, R.1    Janssen, I.2
  • 3
    • 33745488462 scopus 로고    scopus 로고
    • Development of methods for body composition studies
    • [3] Mattsson, S., Thomas, B.J., Development of methods for body composition studies. Phys. Med. Biol. 51 (2006), R203–R228.
    • (2006) Phys. Med. Biol. , vol.51 , pp. R203-R228
    • Mattsson, S.1    Thomas, B.J.2
  • 4
    • 0018355241 scopus 로고
    • Accurate measurement of liver kidney, and spleen volume and mass by computerized axial tomography
    • [4] Heymsfield, S.B., Fulenwider, T., Nordlinger, B., Barlow, R., Sones, P., Kutner, M., Accurate measurement of liver kidney, and spleen volume and mass by computerized axial tomography. Ann. Intern. Med. 90 (1979), 185–187.
    • (1979) Ann. Intern. Med. , vol.90 , pp. 185-187
    • Heymsfield, S.B.1    Fulenwider, T.2    Nordlinger, B.3    Barlow, R.4    Sones, P.5    Kutner, M.6
  • 5
    • 0018345655 scopus 로고
    • A radiographic method of quantifying protein-calorie undernutrition
    • [5] Heymsfield, S.B., Olafson, R.P., Kutner, M.H., Nixon, D.W., A radiographic method of quantifying protein-calorie undernutrition. Am. J. Clin. Nutr. 32 (1979), 693–702.
    • (1979) Am. J. Clin. Nutr. , vol.32 , pp. 693-702
    • Heymsfield, S.B.1    Olafson, R.P.2    Kutner, M.H.3    Nixon, D.W.4
  • 7
    • 0025204640 scopus 로고
    • Adipose tissue determinations in cadavers-a comparison between cross-sectional planimetry and computed tomography
    • [7] Rossner, S., Bo, W.J., Hiltbrandt, E., Hinson, W., Karstaedt, N., Santago, P., Sobol, W.T., Crouse, J.R., Adipose tissue determinations in cadavers-a comparison between cross-sectional planimetry and computed tomography. Int. J. Obes. 14 (1990), 893–902.
    • (1990) Int. J. Obes. , vol.14 , pp. 893-902
    • Rossner, S.1    Bo, W.J.2    Hiltbrandt, E.3    Hinson, W.4    Karstaedt, N.5    Santago, P.6    Sobol, W.T.7    Crouse, J.R.8
  • 8
    • 0031829972 scopus 로고    scopus 로고
    • Cadaver validation of skeletal muscle measurement by magnetic resonance imaging and computerized tomography
    • [8] Mitsiopoulos, N., Baumgartner, R.N., Heymsfield, S.B., Lyons, W., Gallagher, D., Ross, R., Cadaver validation of skeletal muscle measurement by magnetic resonance imaging and computerized tomography. J. Appl. Physiol. 85 (1998), 115–122.
    • (1998) J. Appl. Physiol. , vol.85 , pp. 115-122
    • Mitsiopoulos, N.1    Baumgartner, R.N.2    Heymsfield, S.B.3    Lyons, W.4    Gallagher, D.5    Ross, R.6
  • 10
    • 45849113635 scopus 로고    scopus 로고
    • Stereological estimation of left-ventricular volumetric and functional parameters from multidetector-row computed tomography data
    • [10] Mazonakis, M., Pagonidis, K., Schlosser, T., Hunold, P., Damilakis, J., Barkhausen, J., Gourtsoyiannis, N., Stereological estimation of left-ventricular volumetric and functional parameters from multidetector-row computed tomography data. Eur. Radiol. 18 (2008), 1338–1349.
    • (2008) Eur. Radiol. , vol.18 , pp. 1338-1349
    • Mazonakis, M.1    Pagonidis, K.2    Schlosser, T.3    Hunold, P.4    Damilakis, J.5    Barkhausen, J.6    Gourtsoyiannis, N.7
  • 12
    • 0015911128 scopus 로고
    • Computerized transverse axial scanning (tomography), part 1. Description of system
    • [12] Hounsfield, G.N., Computerized transverse axial scanning (tomography), part 1. Description of system. Br. J. Radiol. 46 (1973), 1016–1022.
    • (1973) Br. J. Radiol. , vol.46 , pp. 1016-1022
    • Hounsfield, G.N.1
  • 13
    • 0025351273 scopus 로고
    • Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation
    • [13] Kalender, W.A., Seissler, W., Klotz, E., Vock, P., Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. Radiology 176 (1990), 181–183.
    • (1990) Radiology , vol.176 , pp. 181-183
    • Kalender, W.A.1    Seissler, W.2    Klotz, E.3    Vock, P.4
  • 14
    • 0003392345 scopus 로고    scopus 로고
    • Biomedical Imaging, Visualization, and Analysis
    • Wiley-Liss New York
    • [14] Robb, R.A., Biomedical Imaging, Visualization, and Analysis. 2000, Wiley-Liss, New York.
    • (2000)
    • Robb, R.A.1
  • 15
    • 0035050272 scopus 로고    scopus 로고
    • Image segmentation in treatment planning for prostate cancer using the region growing technique
    • [15] Mazonakis, M., Damilakis, J., Varveris, H., Prassopoulos, P., Gourtsoyiannis, N., Image segmentation in treatment planning for prostate cancer using the region growing technique. Br. J. Radiol. 74 (2001), 243–248.
    • (2001) Br. J. Radiol. , vol.74 , pp. 243-248
    • Mazonakis, M.1    Damilakis, J.2    Varveris, H.3    Prassopoulos, P.4    Gourtsoyiannis, N.5
  • 16
    • 79955576938 scopus 로고    scopus 로고
    • Assessment of left ventricular function and mass by MR imaging: a stereological study based on the systematic slice sampling procedure
    • [16] Mazonakis, M., Sahin, B., Pagonidis, K., Damilakis, J., Assessment of left ventricular function and mass by MR imaging: a stereological study based on the systematic slice sampling procedure. Acad. Radiol. 18 (2011), 738–744.
    • (2011) Acad. Radiol. , vol.18 , pp. 738-744
    • Mazonakis, M.1    Sahin, B.2    Pagonidis, K.3    Damilakis, J.4
  • 18
    • 79251502946 scopus 로고    scopus 로고
    • Splenic volume model constructed from standardized one-dimensional MDCT measurements
    • [18] Rezai, P., Tochetto, S.M., Galizia, M.S., Yaghmai, V., Splenic volume model constructed from standardized one-dimensional MDCT measurements. Am. J. Roentegenol. 196 (2011), 367–372.
    • (2011) Am. J. Roentegenol. , vol.196 , pp. 367-372
    • Rezai, P.1    Tochetto, S.M.2    Galizia, M.S.3    Yaghmai, V.4
  • 20
    • 84901441831 scopus 로고    scopus 로고
    • Simplified method to measure renal volume: the best correction factor for the ellipsoid formula volume calculation in pretransplant computed tomographic liver donor
    • [20] Zakhari, N., Blew, B., Shabana, W., Simplified method to measure renal volume: the best correction factor for the ellipsoid formula volume calculation in pretransplant computed tomographic liver donor. Urology 83 (2014), e15–e19.
    • (2014) Urology , vol.83 , pp. e15-e19
    • Zakhari, N.1    Blew, B.2    Shabana, W.3
  • 21
    • 0024232936 scopus 로고
    • Total and visceral adipose-tissue volumes derived from measurements with computed tomography in adult men and women: predictive equations
    • [21] Kvist, H., Chowdhury, B., Grangard, U., Tylen, U., Sjostrom, L., Total and visceral adipose-tissue volumes derived from measurements with computed tomography in adult men and women: predictive equations. Am. J. Clin. Nutr. 48 (1988), 1351–1361.
    • (1988) Am. J. Clin. Nutr. , vol.48 , pp. 1351-1361
    • Kvist, H.1    Chowdhury, B.2    Grangard, U.3    Tylen, U.4    Sjostrom, L.5
  • 22
    • 0029795310 scopus 로고    scopus 로고
    • Magnetic resonance imaging provides new insights into the characterization of adipose and lean tissue distribution
    • [22] Ross, R., Magnetic resonance imaging provides new insights into the characterization of adipose and lean tissue distribution. Can. J. Physiol. Pharmacol. 74 (1996), 778–785.
    • (1996) Can. J. Physiol. Pharmacol. , vol.74 , pp. 778-785
    • Ross, R.1
  • 23
    • 0041728959 scopus 로고    scopus 로고
    • Volume estimates by imaging methods: model comparisons with visible woman as the reference
    • [23] Shen, W., Wang, Z., Tang, H., Heshka, S., Punyanitya, M., Zhu, S., Lei, J., Heymsfield, S.B., Volume estimates by imaging methods: model comparisons with visible woman as the reference. Obes. Res. 11 (2003), 217–225.
    • (2003) Obes. Res. , vol.11 , pp. 217-225
    • Shen, W.1    Wang, Z.2    Tang, H.3    Heshka, S.4    Punyanitya, M.5    Zhu, S.6    Lei, J.7    Heymsfield, S.B.8
  • 24
    • 0022485185 scopus 로고
    • Determination of total adipose tissue and body fat in women by computed tomography 40K, and tritium
    • [24] Sjostrom, L., Kvist, H., Cederblad, A., Tylen, U., Determination of total adipose tissue and body fat in women by computed tomography 40K, and tritium. Am. J. Physiol. 250 (1986), E736–E745.
    • (1986) Am. J. Physiol. , vol.250 , pp. E736-E745
    • Sjostrom, L.1    Kvist, H.2    Cederblad, A.3    Tylen, U.4
  • 25
    • 0142209266 scopus 로고    scopus 로고
    • Advances in the application of imaging methods in applied and clinical physiology
    • [25] Ross, R., Advances in the application of imaging methods in applied and clinical physiology. Acta Diabetol. 40 (2003), S45–S50.
    • (2003) Acta Diabetol. , vol.40 , pp. S45-S50
    • Ross, R.1
  • 26
    • 85047699689 scopus 로고    scopus 로고
    • A novel method of measuring intra-abdominal fat volume using helical computed tomography
    • [26] Kobayashi, J., Tadokoro, N., Watabane, M., Shinomiya, M., A novel method of measuring intra-abdominal fat volume using helical computed tomography. Int. J. Obes. Relat. Metab. Disord. 26 (2002), 398–402.
    • (2002) Int. J. Obes. Relat. Metab. Disord. , vol.26 , pp. 398-402
    • Kobayashi, J.1    Tadokoro, N.2    Watabane, M.3    Shinomiya, M.4
  • 27
    • 77950867280 scopus 로고    scopus 로고
    • Association between single-slice measurements of visceral and abdominal subcutaneous adipose tissue with volumetric measurements: the Framingham Heart Study
    • [27] Irlbeck, T., Massaro, J.M., Bamberg, F., O'Connell, C.J., Hoffmann, U., Fox, C.S., Association between single-slice measurements of visceral and abdominal subcutaneous adipose tissue with volumetric measurements: the Framingham Heart Study. Int. J. Obes. 34 (2010), 781–787.
    • (2010) Int. J. Obes. , vol.34 , pp. 781-787
    • Irlbeck, T.1    Massaro, J.M.2    Bamberg, F.3    O'Connell, C.J.4    Hoffmann, U.5    Fox, C.S.6
  • 29
    • 77956220614 scopus 로고    scopus 로고
    • Computed tomography-based validation of abdominal adiposity measurements from ultrasonography, dual energy X-ray absorptiometry and anthropometry
    • [29] Gradmark, A.M.I., Rydh, A., Renstrom, F., De Lucia-Rolfe, E., Sleigh, A., Nordstrom, P., Brage, S., Franks, P.W., Computed tomography-based validation of abdominal adiposity measurements from ultrasonography, dual energy X-ray absorptiometry and anthropometry. Br. J. Nutr. 104 (2010), 582–588.
    • (2010) Br. J. Nutr. , vol.104 , pp. 582-588
    • Gradmark, A.M.I.1    Rydh, A.2    Renstrom, F.3    De Lucia-Rolfe, E.4    Sleigh, A.5    Nordstrom, P.6    Brage, S.7    Franks, P.W.8
  • 30
    • 84901333976 scopus 로고    scopus 로고
    • Optimization of abdominal fat quantification on CT imaging through use of standardized anatomic space: a novel approach
    • (11 pp.)
    • [30] Tong, Y., Udupa, J.K., Torigian, D.A., Optimization of abdominal fat quantification on CT imaging through use of standardized anatomic space: a novel approach. Med. Phys., 41, 2014, 063501 (11 pp.).
    • (2014) Med. Phys. , vol.41 , pp. 063501
    • Tong, Y.1    Udupa, J.K.2    Torigian, D.A.3
  • 32
    • 84957937675 scopus 로고    scopus 로고
    • Abdominal fat volume estimation by stereology on CT: a comparison with manual planimetry
    • [32] Manios, G.E., Mazonakis, M., Voulgaris, C., Karantanas, A., Damilakis, J., Abdominal fat volume estimation by stereology on CT: a comparison with manual planimetry. Eur. Radiol. 26 (2016), 706–713.
    • (2016) Eur. Radiol. , vol.26 , pp. 706-713
    • Manios, G.E.1    Mazonakis, M.2    Voulgaris, C.3    Karantanas, A.4    Damilakis, J.5
  • 33
    • 77950485782 scopus 로고    scopus 로고
    • Skeletal muscle loss: cachexia, sarcopenia and inactivity
    • [33] Evans, W.J., Skeletal muscle loss: cachexia, sarcopenia and inactivity. Am. J. Clin. Nutr. 91 (2010), 1123S–1127S.
    • (2010) Am. J. Clin. Nutr. , vol.91 , pp. 1123S-1127S
    • Evans, W.J.1
  • 34
    • 0018102589 scopus 로고
    • Cross-sectional area of the thigh muscle in man measured by computed tomography
    • [34] Haggmark, T., Jansson, E., Svane, B., Cross-sectional area of the thigh muscle in man measured by computed tomography. Scand. J. Clin. Lab. Invest. 38 (1978), 355–360.
    • (1978) Scand. J. Clin. Lab. Invest. , vol.38 , pp. 355-360
    • Haggmark, T.1    Jansson, E.2    Svane, B.3
  • 35
    • 0033912816 scopus 로고    scopus 로고
    • Skeletal muscle attenuation determined by computed tomography is associated with skeletal muscle lipid content
    • [35] Goodpaster, B.H., Kelley, D.E., Thaete, F.L., He, J., Ross, R., Skeletal muscle attenuation determined by computed tomography is associated with skeletal muscle lipid content. J. Appl. Physiol. 89 (2000), 104–110.
    • (2000) J. Appl. Physiol. , vol.89 , pp. 104-110
    • Goodpaster, B.H.1    Kelley, D.E.2    Thaete, F.L.3    He, J.4    Ross, R.5
  • 37
    • 16544378274 scopus 로고    scopus 로고
    • Relation between whole-body and regional measures of human skeletal muscle
    • [37] Lee, S.J., Janssen, I., Heymsfield, S.B., Ross, R., Relation between whole-body and regional measures of human skeletal muscle. Am. J. Clin. Nutr. 80 (2004), 1215–1221.
    • (2004) Am. J. Clin. Nutr. , vol.80 , pp. 1215-1221
    • Lee, S.J.1    Janssen, I.2    Heymsfield, S.B.3    Ross, R.4
  • 39
    • 33746467944 scopus 로고    scopus 로고
    • Look AHEAD Adipose Research Group, Muscle-associated triglyceride measured by computed tomography and magnetic resonance spectroscopy
    • [39] Larson-Meyer, D.E., Smith, S.R., Heilbronn, L.K., Kelley, D.E., Ravussin, E., Newcomer, B.R., Look AHEAD Adipose Research Group, Muscle-associated triglyceride measured by computed tomography and magnetic resonance spectroscopy. Obesity 14 (2006), 73–87.
    • (2006) Obesity , vol.14 , pp. 73-87
    • Larson-Meyer, D.E.1    Smith, S.R.2    Heilbronn, L.K.3    Kelley, D.E.4    Ravussin, E.5    Newcomer, B.R.6
  • 41
    • 0033951417 scopus 로고    scopus 로고
    • Measuring leg muscle and fat mass in humans: comparison of CT and dual-energy X-ray absorptiometry
    • [41] Levine, J.A., Abboud, L., Barry, M., Reed, J.E., Sheedy, P.F., Jensen, M.D., Measuring leg muscle and fat mass in humans: comparison of CT and dual-energy X-ray absorptiometry. J. Appl. Physiol. 88 (2000), 452–456.
    • (2000) J. Appl. Physiol. , vol.88 , pp. 452-456
    • Levine, J.A.1    Abboud, L.2    Barry, M.3    Reed, J.E.4    Sheedy, P.F.5    Jensen, M.D.6
  • 43
    • 34447509617 scopus 로고    scopus 로고
    • Unenhanced CT for assessment of macrovesicular hepatic steatosis in living liver donors: comparison of visual grading with liver attenuation index
    • [43] Lee, S.W., Park, S.H., Kim, K.W., Choi, E.K., Shin, Y.M., Kim, P.N., Lee, K.H., Yu, E.S., Hwang, S., Lee, S.G., Unenhanced CT for assessment of macrovesicular hepatic steatosis in living liver donors: comparison of visual grading with liver attenuation index. Radiology 244 (2007), 479–485.
    • (2007) Radiology , vol.244 , pp. 479-485
    • Lee, S.W.1    Park, S.H.2    Kim, K.W.3    Choi, E.K.4    Shin, Y.M.5    Kim, P.N.6    Lee, K.H.7    Yu, E.S.8    Hwang, S.9    Lee, S.G.10
  • 44
    • 0019142494 scopus 로고
    • Difference between liver and spleen CT numbers in the normal adult: its usefulness in predicting the presence of diffuse liver disease
    • [44] Piekarski, J., Goldberg, H.I., Royal, S.A., Axel, L., Moss, A.A., Difference between liver and spleen CT numbers in the normal adult: its usefulness in predicting the presence of diffuse liver disease. Radiology 137 (1980), 727–729.
    • (1980) Radiology , vol.137 , pp. 727-729
    • Piekarski, J.1    Goldberg, H.I.2    Royal, S.A.3    Axel, L.4    Moss, A.A.5
  • 45
    • 84867894361 scopus 로고    scopus 로고
    • Evolving concepts on adjusting human resting energy expenditure measurements for body size
    • [45] Heymsfield, S.B., Thomas, D., Bosy-Westphal, A., Shen, W., Peterson, C.M., Muller, M.J., Evolving concepts on adjusting human resting energy expenditure measurements for body size. Obes. Rev. 13 (2012), 1001–1014.
    • (2012) Obes. Rev. , vol.13 , pp. 1001-1014
    • Heymsfield, S.B.1    Thomas, D.2    Bosy-Westphal, A.3    Shen, W.4    Peterson, C.M.5    Muller, M.J.6
  • 47
    • 0030808638 scopus 로고    scopus 로고
    • Relationship between resting metabolic rate and the composition of the fat-free mass
    • [47] Sparti, A., DeLany, J.E., de la Bretonne, J.A., Sander, G.E., Bray, G.A., Relationship between resting metabolic rate and the composition of the fat-free mass. Metabolism 46 (1997), 1225–1230.
    • (1997) Metabolism , vol.46 , pp. 1225-1230
    • Sparti, A.1    DeLany, J.E.2    de la Bretonne, J.A.3    Sander, G.E.4    Bray, G.A.5
  • 48
    • 63649151886 scopus 로고    scopus 로고
    • A viscerally driven cachexia syndrome in patients with advanced colorectal cancer: contributions of organ and tunor mass to whole-body energy demands
    • [48] Liefers, J.R., Mourtzakis, M., Hall, K.D., McCargar, L.J., Prado, C.M.M., Baracos, V.E., A viscerally driven cachexia syndrome in patients with advanced colorectal cancer: contributions of organ and tunor mass to whole-body energy demands. Am. J. Clin. Nutr. 89 (2009), 1173–1179.
    • (2009) Am. J. Clin. Nutr. , vol.89 , pp. 1173-1179
    • Liefers, J.R.1    Mourtzakis, M.2    Hall, K.D.3    McCargar, L.J.4    Prado, C.M.M.5    Baracos, V.E.6
  • 49
    • 0032075742 scopus 로고    scopus 로고
    • Bladder and rectum volume estimations using CT and stereology
    • [49] Mazonakis, M., Damilakis, J., Varveris, H., Bladder and rectum volume estimations using CT and stereology. Comput. Med. Imaging Graph. 22 (1998), 195–201.
    • (1998) Comput. Med. Imaging Graph. , vol.22 , pp. 195-201
    • Mazonakis, M.1    Damilakis, J.2    Varveris, H.3
  • 50
    • 84939977324 scopus 로고    scopus 로고
    • Efficient stereological approaches for the volumetry of a normal or enlarged spleen from MDCT images
    • [50] Mazonakis, M., Stratakis, J., Damilakis, J., Efficient stereological approaches for the volumetry of a normal or enlarged spleen from MDCT images. Eur. Radiol. 25 (2015), 1761–1767.
    • (2015) Eur. Radiol. , vol.25 , pp. 1761-1767
    • Mazonakis, M.1    Stratakis, J.2    Damilakis, J.3
  • 52
    • 34248641980 scopus 로고    scopus 로고
    • An update on the assessment of osteoporosis using radiologic techniques
    • [52] Damilakis, J., Maris, T.G., Karantanas, A.H., An update on the assessment of osteoporosis using radiologic techniques. Eur. Radiol. 17 (2007), 1591–1602.
    • (2007) Eur. Radiol. , vol.17 , pp. 1591-1602
    • Damilakis, J.1    Maris, T.G.2    Karantanas, A.H.3
  • 54
    • 80052898612 scopus 로고    scopus 로고
    • Integrated imaging approach to osteoporosis: state-of-the-art review and update
    • [54] Guglielmi, G., Muscarella, S., Bazzocchi, A., Integrated imaging approach to osteoporosis: state-of-the-art review and update. Radiographics 31 (2011), 1343–1364.
    • (2011) Radiographics , vol.31 , pp. 1343-1364
    • Guglielmi, G.1    Muscarella, S.2    Bazzocchi, A.3
  • 55
    • 84944352246 scopus 로고    scopus 로고
    • Association of osteoloytic lesions, bone mineral loss and trabecular sclerosis with prevalent vertebral fractures in patients with multiple myeloma
    • [55] Borggrefe, J., Giravent, S., Campbell, G., Thomsen, F., Chang, D., Franke, M., Gunther, A., Heller, M., Wulff, A., Association of osteoloytic lesions, bone mineral loss and trabecular sclerosis with prevalent vertebral fractures in patients with multiple myeloma. Eur. J. Radiol. 84 (2015), 2269–2274.
    • (2015) Eur. J. Radiol. , vol.84 , pp. 2269-2274
    • Borggrefe, J.1    Giravent, S.2    Campbell, G.3    Thomsen, F.4    Chang, D.5    Franke, M.6    Gunther, A.7    Heller, M.8    Wulff, A.9
  • 56
    • 77957877373 scopus 로고    scopus 로고
    • Radiation exposure in X-ray-based imaging techniques used in osteoporosis
    • [56] Damilakis, J., Adams, J.E., Guglielmi, G., Link, T.M., Radiation exposure in X-ray-based imaging techniques used in osteoporosis. Eur. Radiol. 20 (2010), 2707–2714.
    • (2010) Eur. Radiol. , vol.20 , pp. 2707-2714
    • Damilakis, J.1    Adams, J.E.2    Guglielmi, G.3    Link, T.M.4
  • 57
    • 77649191493 scopus 로고    scopus 로고
    • Fast segmentation of bone in CT images using 3D adaptive thresholding
    • [57] Zhang, J., Yan, C.H., Chui, C.K., Ong, S.H., Fast segmentation of bone in CT images using 3D adaptive thresholding. Comp. Biol. Med. 40 (2010), 231–236.
    • (2010) Comp. Biol. Med. , vol.40 , pp. 231-236
    • Zhang, J.1    Yan, C.H.2    Chui, C.K.3    Ong, S.H.4
  • 58
    • 0038782206 scopus 로고    scopus 로고
    • A new accurate and precise 3-D segmentation method for skeletal structures in volumetric CT data
    • [58] Kang, Y., Engelke, K., Kalender, W.A., A new accurate and precise 3-D segmentation method for skeletal structures in volumetric CT data. IEEE Trans. Med. Imaging 22 (2003), 586–598.
    • (2003) IEEE Trans. Med. Imaging , vol.22 , pp. 586-598
    • Kang, Y.1    Engelke, K.2    Kalender, W.A.3
  • 59
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography-An increasing source of radiation exposure
    • [59] Brenner, D.J., Hall, E.J., Computed tomography-An increasing source of radiation exposure. N. Engl. J. Med. 357 (2007), 2277–2284.
    • (2007) N. Engl. J. Med. , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 60
    • 84455180605 scopus 로고    scopus 로고
    • The clinical importance of visceral adiposity: a critical review of methods for visceral adipose tissue analysis
    • [60] Shuster, A., Patlas, M., Pinthus, J.H., Mourtzakis, M., The clinical importance of visceral adiposity: a critical review of methods for visceral adipose tissue analysis. Br. J. Radiol. 85 (2012), 1–10.
    • (2012) Br. J. Radiol. , vol.85 , pp. 1-10
    • Shuster, A.1    Patlas, M.2    Pinthus, J.H.3    Mourtzakis, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.