메뉴 건너뛰기




Volumn 32, Issue 3, 2016, Pages 194-199

Regenerative Peripheral Nerve Interface for Prostheses Control: Electrode Comparison

Author keywords

epimysial patch electrode; intramuscular hook electrode; regenerative peripheral nerve interface

Indexed keywords

ADULT; ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; ELECTRODE; ELECTROMYOGRAPHY; EXTENSOR DIGITORUM LONGUS MUSCLE; MALE; MUSCLE INJURY; MYOELECTRIC CONTROL; NONHUMAN; PERIPHERAL NERVE; PERONEUS NERVE; PRIORITY JOURNAL; PROSTHESIS; RAT; RECORDING; STIMULATION; TIBIAL NERVE; ANIMAL; ELECTROSTIMULATION; FISCHER 344 RAT; HINDLIMB; INNERVATION; NERVE REGENERATION; PHYSIOLOGY; PROCEDURES; SKELETAL MUSCLE; SURGERY;

EID: 84960436241     PISSN: 0743684X     EISSN: 10988947     Source Type: Journal    
DOI: 10.1055/s-0035-1565248     Document Type: Article
Times cited : (11)

References (26)
  • 2
    • 33947221900 scopus 로고    scopus 로고
    • Traumatic below-elbow amputations
    • Freeland A. E., Psonak R. Traumatic below-elbow amputations. Orthopedics: 2007; 30 2 120 126
    • (2007) Orthopedics , vol.30 , Issue.2 , pp. 120-126
    • Freeland, A.E.1    Psonak, R.2
  • 3
    • 84899121347 scopus 로고    scopus 로고
    • Upper extremity limb loss: Functional restoration from prosthesis and targeted reinnervation to transplantation
    • quiz 114
    • Carlsen B. T., Prigge P., Peterson J. Upper extremity limb loss: Functional restoration from prosthesis and targeted reinnervation to transplantation. J Hand Ther: 2014; 27 2 106 113, quiz 114
    • (2014) J Hand Ther , vol.27 , Issue.2 , pp. 106-113
    • Carlsen, B.T.1    Prigge, P.2    Peterson, J.3
  • 4
    • 29644439037 scopus 로고    scopus 로고
    • Direct neural sensory feedback and control of a prosthetic arm
    • Dhillon G. S., Horch K. W. Direct neural sensory feedback and control of a prosthetic arm. IEEE Trans Neural Syst Rehabil Eng: 2005; 13 4 468 472
    • (2005) IEEE Trans Neural Syst Rehabil Eng , vol.13 , Issue.4 , pp. 468-472
    • Dhillon, G.S.1    Horch, K.W.2
  • 6
    • 37349110986 scopus 로고    scopus 로고
    • Upper-limb prosthetics: Critical factors in device abandonment
    • Biddiss E., Chau T. Upper-limb prosthetics: Critical factors in device abandonment. Am J Phys Med Rehabil: 2007; 86 12 977 987
    • (2007) Am J Phys Med Rehabil , vol.86 , Issue.12 , pp. 977-987
    • Biddiss, E.1    Chau, T.2
  • 7
    • 35848949332 scopus 로고    scopus 로고
    • Upper limb prosthesis use and abandonment: A survey of the last 25 years
    • Biddiss E. A., Chau T. T. Upper limb prosthesis use and abandonment: A survey of the last 25 years. Prosthet Orthot Int: 2007; 31 3 236 257
    • (2007) Prosthet Orthot Int , vol.31 , Issue.3 , pp. 236-257
    • Biddiss, E.A.1    Chau, T.T.2
  • 8
    • 0029076241 scopus 로고
    • Prosthetic usage in major upper extremity amputations
    • Wright T. W., Hagen A. D., Wood M. B. Prosthetic usage in major upper extremity amputations. J Hand Surg Am: 1995; 20 4 619 622
    • (1995) J Hand Surg Am , vol.20 , Issue.4 , pp. 619-622
    • Wright, T.W.1    Hagen, A.D.2    Wood, M.B.3
  • 10
    • 78751605802 scopus 로고    scopus 로고
    • Neural interfaces for control of upper limb prostheses: The state of the art and future possibilities
    • Schultz A. E., Kuiken T. A. Neural interfaces for control of upper limb prostheses: The state of the art and future possibilities. PM R: 2011; 3 1 55 67
    • (2011) PM R , vol.3 , Issue.1 , pp. 55-67
    • Schultz, A.E.1    Kuiken, T.A.2
  • 11
    • 84889052521 scopus 로고    scopus 로고
    • Early muscle revascularization and regeneration at the regenerative peripheral nerve interface
    • Baldwin J., Mood J. D., Cederna P. S., Urbanchek M. G. Early muscle revascularization and regeneration at the regenerative peripheral nerve interface. Plast Reconstr Surg: 2012; 130 1S 73
    • (2012) Plast Reconstr Surg , vol.130 , Issue.1 S , pp. 73
    • Baldwin, J.1    Mood, J.D.2    Cederna, P.S.3    Urbanchek, M.G.4
  • 12
    • 84902186800 scopus 로고    scopus 로고
    • Regenerative peripheral nerve interface viability and signal transduction with an implanted electrode
    • Kung T. A., Langhals N. B., Martin D. C., Johnson P. J., Cederna P. S., Urbanchek M. G. Regenerative peripheral nerve interface viability and signal transduction with an implanted electrode. Plast Reconstr Surg: 2014; 133 6 1380 1394
    • (2014) Plast Reconstr Surg , vol.133 , Issue.6 , pp. 1380-1394
    • Kung, T.A.1    Langhals, N.B.2    Martin, D.C.3    Johnson, P.J.4    Cederna, P.S.5    Urbanchek, M.G.6
  • 13
    • 84888987745 scopus 로고    scopus 로고
    • Long-Term Stability of Regenerative Peripheral Nerve Interfaces (RPNI)
    • Urbanchek M. G., Wei B., Baghmanli Z., Sugg K., Cederna P. S. Long-Term Stability of Regenerative Peripheral Nerve Interfaces (RPNI). Plast Reconstr Surg: 2011; 128 4S 88 89
    • (2011) Plast Reconstr Surg , vol.128 , Issue.4 S , pp. 88-89
    • Urbanchek, M.G.1    Wei, B.2    Baghmanli, Z.3    Sugg, K.4    Cederna, P.S.5
  • 15
    • 27644591279 scopus 로고    scopus 로고
    • A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems
    • Navarro X., Krueger T. B., Lago N., Micera S., Stieglitz T., Dario P. A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems. J Peripher Nerv Syst: 2005; 10 3 229 258
    • (2005) J Peripher Nerv Syst , vol.10 , Issue.3 , pp. 229-258
    • Navarro, X.1    Krueger, T.B.2    Lago, N.3    Micera, S.4    Stieglitz, T.5    Dario, P.6
  • 16
    • 84929492597 scopus 로고    scopus 로고
    • Electrically stimulated signals from a long-term regenerative peripheral nerve interface
    • Langhals N. B., Woo S. L., Moon J. D., et al. Electrically stimulated signals from a long-term regenerative peripheral nerve interface. Conf Proc IEEE Eng Med Biol Soc: 2014; 1989 1992
    • (2014) Conf Proc IEEE Eng Med Biol Soc , pp. 1989-1992
    • Langhals, N.B.1    Woo, S.L.2    Moon, J.D.3
  • 17
    • 84929494220 scopus 로고    scopus 로고
    • Quantification of muscle-derived signal interference during monopolar needle electromyography of a peripheral nerve interface in the rat hind limb
    • Woo S. L., Urbanchek M. G., Leach M. K., Moon J. D., Cederna P., Langhals N. B. Quantification of muscle-derived signal interference during monopolar needle electromyography of a peripheral nerve interface in the rat hind limb. Conf Proc IEEE Eng Med Biol Soc: 2014; 4382 4385
    • (2014) Conf Proc IEEE Eng Med Biol Soc , pp. 4382-4385
    • Woo, S.L.1    Urbanchek, M.G.2    Leach, M.K.3    Moon, J.D.4    Cederna, P.5    Langhals, N.B.6
  • 18
    • 0022501701 scopus 로고
    • Architecture, composition, and contractile properties of rat soleus muscle grafts
    • (3 Pt 1)
    • Segal S. S., White T. P., Faulkner J. A. Architecture, composition, and contractile properties of rat soleus muscle grafts. Am J Physiol: 1986; 250 (3 Pt 1): C474 C479
    • (1986) Am J Physiol , vol.250 , pp. C474-C479
    • Segal, S.S.1    White, T.P.2    Faulkner, J.A.3
  • 20
    • 34247366472 scopus 로고    scopus 로고
    • A comparison of surface and intramuscular myoelectric signal classification
    • Hargrove L. J., Englehart K., Hudgins B. A comparison of surface and intramuscular myoelectric signal classification. IEEE Trans Biomed Eng: 2007; 54 5 847 853
    • (2007) IEEE Trans Biomed Eng , vol.54 , Issue.5 , pp. 847-853
    • Hargrove, L.J.1    Englehart, K.2    Hudgins, B.3
  • 21
    • 0019296171 scopus 로고
    • Intramuscular electrical stimulation: Tissue damage
    • Mortimer J. T., Kaufman D., Roessman U. Intramuscular electrical stimulation: Tissue damage. Ann Biomed Eng: 1980; 8 3 235 244
    • (1980) Ann Biomed Eng , vol.8 , Issue.3 , pp. 235-244
    • Mortimer, J.T.1    Kaufman, D.2    Roessman, U.3
  • 22
    • 0025986541 scopus 로고
    • PH-induced effects on median frequency and conduction velocity of the myoelectric signal
    • Brody L. R., Pollock M. T., Roy S. H., De Luca C. J., Celli B. pH-induced effects on median frequency and conduction velocity of the myoelectric signal. J Appl Physiol (1985): 1991; 71 5 1878 1885
    • (1991) J Appl Physiol (1985) , vol.71 , Issue.5 , pp. 1878-1885
    • Brody, L.R.1    Pollock, M.T.2    Roy, S.H.3    De Luca, C.J.4    Celli, B.5
  • 23
    • 0033962326 scopus 로고    scopus 로고
    • Relationship between EMG signals and force in human vastus lateralis muscle using multiple bipolar wire electrodes
    • Onishi H., Yagi R., Akasaka K., Momose K., Ihashi K., Handa Y. Relationship between EMG signals and force in human vastus lateralis muscle using multiple bipolar wire electrodes. J Electromyogr Kinesiol: 2000; 10 1 59 67
    • (2000) J Electromyogr Kinesiol , vol.10 , Issue.1 , pp. 59-67
    • Onishi, H.1    Yagi, R.2    Akasaka, K.3    Momose, K.4    Ihashi, K.5    Handa, Y.6
  • 24
    • 84897744238 scopus 로고    scopus 로고
    • Poly(3,4-ethylenedioxythiophene) on decellular scaffolding interrupts grafted muscle revascularization
    • Baldwin J. F., Washabaugh E. P. IV, Moon J. D., et al. Poly(3,4-ethylenedioxythiophene) on decellular scaffolding interrupts grafted muscle revascularization. 6th Int IEEE EMBS Conf Neural Eng: 2013; 1461 1464
    • (2013) 6th Int IEEE EMBS Conf Neural Eng , pp. 1461-1464
    • Baldwin, J.F.1    Washabaugh, E.P.2    Moon, J.D.3
  • 25
    • 50049093848 scopus 로고    scopus 로고
    • A comparison of the effects of electrode implantation and targeting on pattern classification accuracy for prosthesis control
    • Farrell T. R., Weir R. F. A comparison of the effects of electrode implantation and targeting on pattern classification accuracy for prosthesis control. IEEE Trans Biomed Eng: 2008; 55 9 2198 2211
    • (2008) IEEE Trans Biomed Eng , vol.55 , Issue.9 , pp. 2198-2211
    • Farrell, T.R.1    Weir, R.F.2
  • 26
    • 0028243130 scopus 로고
    • Electrical properties of implant encapsulation tissue
    • Grill W. M., Mortimer J. T. Electrical properties of implant encapsulation tissue. Ann Biomed Eng: 1994; 22 1 23 33
    • (1994) Ann Biomed Eng , vol.22 , Issue.1 , pp. 23-33
    • Grill, W.M.1    Mortimer, J.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.