메뉴 건너뛰기




Volumn 10, Issue 1, 2016, Pages 28-36

3D printing based on cardiac CT assists anatomic visualization prior to transcatheter aortic valve replacement

Author keywords

3D printing; Additive manufacturing; Aortic valve; Paraoartic regurgitation; Paravalvular leak; TAVR; Three dimensional

Indexed keywords

ACCURACY; ADULT; AGED; AORTA ROOT; AORTA VALVE REGURGITATION; ARTICLE; CARDIAC GATED IMAGING; CARDIAC IMAGING; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DIGITAL IMAGING AND COMMUNICATIONS IN MEDICINE; ECHOCARDIOGRAPHY; FEASIBILITY STUDY; FEMALE; FOLLOW UP; HUMAN; MALE; PARAVALVULAR LEAK; PREDICTION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; RIGHT CORONARY ARTERY; THREE DIMENSIONAL PRINTING; TRANSCATHETER AORTIC VALVE IMPLANTATION; ANATOMIC MODEL; AORTIC VALVE; AORTIC VALVE INSUFFICIENCY; AORTOGRAPHY; BIOLOGICAL MODEL; CLINICAL TRIAL; COMPUTER INTERFACE; COMPUTER SIMULATION; DEVICE FAILURE ANALYSIS; DEVICES; DIAGNOSTIC IMAGING; HEART VALVE PROSTHESIS; PROCEDURES; PROSTHESIS DESIGN; PROSTHETIC FITTING; THREE DIMENSIONAL IMAGING; TREATMENT OUTCOME; VERY ELDERLY; X-RAY COMPUTED TOMOGRAPHY;

EID: 84958836208     PISSN: 19345925     EISSN: 1876861X     Source Type: Journal    
DOI: 10.1016/j.jcct.2015.12.004     Document Type: Article
Times cited : (171)

References (28)
  • 1
    • 84926117159 scopus 로고    scopus 로고
    • Transcatheter aortic valve replacement for patients with heart failure
    • Himbert D., Vahanian A. Transcatheter aortic valve replacement for patients with heart failure. Heart Fail Clin 2015, 11:231-242. 10.1016/j.hfc.2014.12.003.
    • (2015) Heart Fail Clin , vol.11 , pp. 231-242
    • Himbert, D.1    Vahanian, A.2
  • 2
    • 84881330796 scopus 로고    scopus 로고
    • Standardized imaging for aortic annular sizing: implications for transcatheter valve selection
    • Kasel A.M., Cassese S., Bleiziffer S., et al. Standardized imaging for aortic annular sizing: implications for transcatheter valve selection. JACC Cardiovasc Imaging 2013, 6:249-262. 10.1016/j.jcmg.2012.12.005.
    • (2013) JACC Cardiovasc Imaging , vol.6 , pp. 249-262
    • Kasel, A.M.1    Cassese, S.2    Bleiziffer, S.3
  • 3
    • 84926375201 scopus 로고    scopus 로고
    • Incidence and severity of paravalvular aortic regurgitation with multidetector computed tomography nominal area oversizing or undersizing after transcatheter heart valve replacement with the sapien 3
    • Yang T.-H., Webb J.G., Blanke P., et al. Incidence and severity of paravalvular aortic regurgitation with multidetector computed tomography nominal area oversizing or undersizing after transcatheter heart valve replacement with the sapien 3. JACC Cardiovasc Interv 2015, 8:462-471. 10.1016/j.jcin.2014.10.014.
    • (2015) JACC Cardiovasc Interv , vol.8 , pp. 462-471
    • Yang, T.-H.1    Webb, J.G.2    Blanke, P.3
  • 4
    • 84877102732 scopus 로고    scopus 로고
    • Paravalvular leak after transcatheter aortic valve replacement: the new achilles' heel? A comprehensive review of the literature
    • Généreux P., Head S.J., Hahn R., et al. Paravalvular leak after transcatheter aortic valve replacement: the new achilles' heel? A comprehensive review of the literature. J Am Coll Cardiol 2013, 61:1125-1136. 10.1016/j.jacc.2012.08.1039.
    • (2013) J Am Coll Cardiol , vol.61 , pp. 1125-1136
    • Généreux, P.1    Head, S.J.2    Hahn, R.3
  • 5
    • 84898056725 scopus 로고    scopus 로고
    • Postprocedural aortic regurgitation in balloon-expandable and self-expandable transcatheter aortic valve replacement procedures: analysis of predictors and impact on long-term mortality: insights from the France2 registry
    • Van Belle E., Juthier F., Susen S., et al. Postprocedural aortic regurgitation in balloon-expandable and self-expandable transcatheter aortic valve replacement procedures: analysis of predictors and impact on long-term mortality: insights from the France2 registry. Circulation 2014, 129:1415-1427. 10.1161/CIRCULATIONAHA.113.002677.
    • (2014) Circulation , vol.129 , pp. 1415-1427
    • Van Belle, E.1    Juthier, F.2    Susen, S.3
  • 6
    • 84930662964 scopus 로고    scopus 로고
    • Three-dimensional virtual surgery models for percutaneous coronary intervention (PCI) optimization strategies
    • January
    • Wang H., Liu J., Zheng X., et al. Three-dimensional virtual surgery models for percutaneous coronary intervention (PCI) optimization strategies. Sci Rep 2015, 5:10945. January. 10.1038/srep10945.
    • (2015) Sci Rep , vol.5 , pp. 10945
    • Wang, H.1    Liu, J.2    Zheng, X.3
  • 7
    • 43249126311 scopus 로고    scopus 로고
    • Rapid prototyping: a new tool in understanding and treating structural heart disease
    • Kim M.S., Hansgen A.R., Wink O., Quaife R.a., Carroll J.D. Rapid prototyping: a new tool in understanding and treating structural heart disease. Circulation 2008, 117:2388-2394. 10.1161/CIRCULATIONAHA.107.740977.
    • (2008) Circulation , vol.117 , pp. 2388-2394
    • Kim, M.S.1    Hansgen, A.R.2    Wink, O.3    Quaife, R.A.4    Carroll, J.D.5
  • 8
    • 84900662687 scopus 로고    scopus 로고
    • 3D heart model guides complex stent angioplasty of pulmonary venous baffle obstruction in a Mustard repair of D-TGA
    • Olivieri L., Krieger A., Chen M.Y., Kim P., Kanter J.P. 3D heart model guides complex stent angioplasty of pulmonary venous baffle obstruction in a Mustard repair of D-TGA. Int J Cardiol 2014, 172:e297-e298. 10.1016/j.ijcard.2013.12.192.
    • (2014) Int J Cardiol , vol.172 , pp. e297-e298
    • Olivieri, L.1    Krieger, A.2    Chen, M.Y.3    Kim, P.4    Kanter, J.P.5
  • 9
    • 84925991186 scopus 로고    scopus 로고
    • Three-dimensional printing in cardiac surgery and interventional cardiology: a single-centre experience
    • Schmauss D., Haeberle S., Hagl C., Sodian R. Three-dimensional printing in cardiac surgery and interventional cardiology: a single-centre experience. Eur J Cardio Thoracic Surg 2014, 1-9. 10.1093/ejcts/ezu310.
    • (2014) Eur J Cardio Thoracic Surg , pp. 1-9
    • Schmauss, D.1    Haeberle, S.2    Hagl, C.3    Sodian, R.4
  • 10
    • 84907970411 scopus 로고    scopus 로고
    • Echocardiography derived three-dimensional printing of normal and abnormal mitral annuli
    • Mahmood F., Owais K., Montealegre-Gallegos M., et al. Echocardiography derived three-dimensional printing of normal and abnormal mitral annuli. Ann Card Anaesth 2014, 17:279. 10.4103/0971-9784.142062.
    • (2014) Ann Card Anaesth , vol.17 , pp. 279
    • Mahmood, F.1    Owais, K.2    Montealegre-Gallegos, M.3
  • 11
    • 0033985202 scopus 로고    scopus 로고
    • Stereolithographic biomodeling to create tangible hard copies of cardiac structures from echocardiographic data: in vitro and in vivo validation
    • Binder T.M., Moertl D., Mundigler G., et al. Stereolithographic biomodeling to create tangible hard copies of cardiac structures from echocardiographic data: in vitro and in vivo validation. J Am Coll Cardiol 2000, 35:230-237. 10.1016/S0735-1097(99)00498-2.
    • (2000) J Am Coll Cardiol , vol.35 , pp. 230-237
    • Binder, T.M.1    Moertl, D.2    Mundigler, G.3
  • 12
    • 84905455970 scopus 로고    scopus 로고
    • Three-dimensional ultrasound-derived physical mitral valve modeling
    • Witschey W.R.T., Pouch A.M., McGarvey J.R., et al. Three-dimensional ultrasound-derived physical mitral valve modeling. Ann Thorac Surg 2014, 98:691-694. 10.1016/j.athoracsur.2014.04.094.
    • (2014) Ann Thorac Surg , vol.98 , pp. 691-694
    • Witschey, W.R.T.1    Pouch, A.M.2    McGarvey, J.R.3
  • 13
    • 84903279050 scopus 로고    scopus 로고
    • 3D heart model printing for preparation of percutaneous structural interventions: description of the technology and case report
    • Dankowski R., Baszko A., Sutherland M., et al. 3D heart model printing for preparation of percutaneous structural interventions: description of the technology and case report. Kardiol Pol 2014, 72:546-551. 10.5603/KP.2014.0119.
    • (2014) Kardiol Pol , vol.72 , pp. 546-551
    • Dankowski, R.1    Baszko, A.2    Sutherland, M.3
  • 14
    • 77249095305 scopus 로고    scopus 로고
    • Development of personalized annuloplasty rings: combination of CT images and CAD-CAM tools
    • Díaz Lantada A., Valle-Fernández R., Del Morgado P.L., et al. Development of personalized annuloplasty rings: combination of CT images and CAD-CAM tools. Ann Biomed Eng 2010, 38:280-290. 10.1007/s10439-009-9805-z.
    • (2010) Ann Biomed Eng , vol.38 , pp. 280-290
    • Díaz Lantada, A.1    Valle-Fernández, R.2    Del Morgado, P.L.3
  • 15
    • 84908211777 scopus 로고    scopus 로고
    • Percutaneous pulmonary valve implantation in a native outflow tract: 3-dimensional DynaCT rotational angiographic reconstruction and 3-dimensional printed model
    • Poterucha J.T., Foley T.A., Taggart N.W. Percutaneous pulmonary valve implantation in a native outflow tract: 3-dimensional DynaCT rotational angiographic reconstruction and 3-dimensional printed model. JACC Cardiovasc Interv 2014, 7:e151-e152. 10.1016/j.jcin.2014.03.015.
    • (2014) JACC Cardiovasc Interv , vol.7 , pp. e151-e152
    • Poterucha, J.T.1    Foley, T.A.2    Taggart, N.W.3
  • 16
    • 34250718737 scopus 로고    scopus 로고
    • Use of rapid prototyping models in the planning of percutaneous pulmonary valved stent implantation
    • Armillotta A., Bonhoeffer P., Dubini G., et al. Use of rapid prototyping models in the planning of percutaneous pulmonary valved stent implantation. Proc Inst Mech Eng H 2007, 221:407-416.
    • (2007) Proc Inst Mech Eng H , vol.221 , pp. 407-416
    • Armillotta, A.1    Bonhoeffer, P.2    Dubini, G.3
  • 17
    • 84870743337 scopus 로고    scopus 로고
    • SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR)
    • Achenbach S., Delgado V., Hausleiter J., Schoenhagen P., Min J.K., Leipsic J.a. SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr 2012, 6:366-380. 10.1016/j.jcct.2012.11.002.
    • (2012) J Cardiovasc Comput Tomogr , vol.6 , pp. 366-380
    • Achenbach, S.1    Delgado, V.2    Hausleiter, J.3    Schoenhagen, P.4    Min, J.K.5    Leipsic, J.A.6
  • 19
    • 84155167086 scopus 로고    scopus 로고
    • Three-dimensional echocardiography: novel uses three-dimensional echocardiography in paravalvular aortic regurgitation assessment after transcatheter aortic valve implantation
    • Goncalves A., Almeria C., Marcos-alberca P., et al. Three-dimensional echocardiography: novel uses three-dimensional echocardiography in paravalvular aortic regurgitation assessment after transcatheter aortic valve implantation. J Am Soc Echocardiogr 2012, 25:47-55. 10.1016/j.echo.2011.08.019.
    • (2012) J Am Soc Echocardiogr , vol.25 , pp. 47-55
    • Goncalves, A.1    Almeria, C.2    Marcos-alberca, P.3
  • 20
    • 84958876332 scopus 로고    scopus 로고
    • 2014
    • Rasband WS. ; 1997-2014. http://imagej.nih.gov/ij/.
    • Rasband, W.S.1
  • 21
    • 84920679318 scopus 로고    scopus 로고
    • Stereoscopic three-dimensional visualization applied to multimodal brain images: clinical applications and a functional connectivity atlas
    • November
    • Rojas G.M., GÃlvez M., Vega Potler N., et al. Stereoscopic three-dimensional visualization applied to multimodal brain images: clinical applications and a functional connectivity atlas. Front Neurosci 2014, 8:1-14. November. 10.3389/fnins.2014.00328.
    • (2014) Front Neurosci , vol.8 , pp. 1-14
    • Rojas, G.M.1    GÃlvez, M.2    Vega Potler, N.3
  • 23
    • 80051781298 scopus 로고    scopus 로고
    • Determination of the elastic modulus of ascending thoracic aortic aneurysm at different ranges of pressure using uniaxial tensile testing
    • Khanafer K., Duprey A., Zainal M., Schlicht M., Williams D., Berguer R. Determination of the elastic modulus of ascending thoracic aortic aneurysm at different ranges of pressure using uniaxial tensile testing. J Thorac Cardiovasc Surg 2011, 142:682-686. 10.1016/j.jtcvs.2010.09.068.
    • (2011) J Thorac Cardiovasc Surg , vol.142 , pp. 682-686
    • Khanafer, K.1    Duprey, A.2    Zainal, M.3    Schlicht, M.4    Williams, D.5    Berguer, R.6
  • 24
    • 84875966943 scopus 로고    scopus 로고
    • Relationship of aortic annular eccentricity and paravalvular regurgitation post transcatheter aortic valve implantation with CoreValve
    • Wong D.T.L., Hons M., Bertaso A.G., et al. Relationship of aortic annular eccentricity and paravalvular regurgitation post transcatheter aortic valve implantation with CoreValve. J Invasive Cardiol 2013, 25:190-195. http://www.ncbi.nlm.nih.gov/pubmed/23549493.
    • (2013) J Invasive Cardiol , vol.25 , pp. 190-195
    • Wong, D.T.L.1    Hons, M.2    Bertaso, A.G.3
  • 25
    • 84947201478 scopus 로고    scopus 로고
    • Aortic valve calcium score is a significant predictor for the occurrence of post-interventional paravalvular leakage after transcatheter aortic valve implantation - Results from a single center analysis of 260 consecutive patients
    • Pavicevic J., Nguyen T.D.L., Caliskan E., et al. Aortic valve calcium score is a significant predictor for the occurrence of post-interventional paravalvular leakage after transcatheter aortic valve implantation - Results from a single center analysis of 260 consecutive patients. Int J Cardiol 2015, 181:185-187. 10.1016/j.ijcard.2014.12.032.
    • (2015) Int J Cardiol , vol.181 , pp. 185-187
    • Pavicevic, J.1    Nguyen, T.D.L.2    Caliskan, E.3
  • 26
    • 84908264633 scopus 로고    scopus 로고
    • Extent and distribution of calcification of both the aortic annulus and the left ventricular outflow tract predict aortic regurgitation after transcatheter aortic valve replacement
    • Buellesfeld L., Stortecky S., Heg D., et al. Extent and distribution of calcification of both the aortic annulus and the left ventricular outflow tract predict aortic regurgitation after transcatheter aortic valve replacement. EuroIntervention 2014, 10:732-738.
    • (2014) EuroIntervention , vol.10 , pp. 732-738
    • Buellesfeld, L.1    Stortecky, S.2    Heg, D.3
  • 27
    • 84896532390 scopus 로고    scopus 로고
    • The aortic valve calcium nodule score (AVCNS) independently predicts paravalvular regurgitation after transcatheter aortic valve replacement (TAVR)
    • Azzalini L., Ghoshhajra B.B., Elmariah S., et al. The aortic valve calcium nodule score (AVCNS) independently predicts paravalvular regurgitation after transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr 2014, 8:131-140. 10.1016/j.jcct.2013.12.013.
    • (2014) J Cardiovasc Comput Tomogr , vol.8 , pp. 131-140
    • Azzalini, L.1    Ghoshhajra, B.B.2    Elmariah, S.3
  • 28
    • 84894292720 scopus 로고    scopus 로고
    • Mechanical properties of components fabricated with open-source 3-D printers under realistic environmental conditions
    • Tymrak B.M., Kreiger M., Pearce J.M. Mechanical properties of components fabricated with open-source 3-D printers under realistic environmental conditions. Mater Des 2014, 58:242-246.
    • (2014) Mater Des , vol.58 , pp. 242-246
    • Tymrak, B.M.1    Kreiger, M.2    Pearce, J.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.