메뉴 건너뛰기




Volumn 25, Issue 4, 2013, Pages 190-195

Relationship of aortic annular eccentricity and paravalvular regurgitation post transcatheter aortic valve implantation with CoreValve

Author keywords

annular eccentricity; computed tomography; CoreValve; paravalvular aortic regurgitation; transcatheter aortic valve implantation

Indexed keywords

AGED; AORTA ROOT; AORTA SINUS; AORTA STENOSIS; AORTA VALVE REGURGITATION; AORTIC ANNULAR ECCENTRICITY; AORTOGRAPHY; ARTICLE; BLOOD VESSEL PARAMETERS; COMPUTER ASSISTED TOMOGRAPHY; DISEASE ASSOCIATION; ECHOCARDIOGRAPHY; ELECTROCARDIOGRAM; FEMALE; HEART EJECTION FRACTION; HEART VALVE BIOPROSTHESIS; HUMAN; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PREDICTIVE VALUE; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; TRANSCATHETER AORTIC VALVE IMPLANTATION; VASCULAR RING;

EID: 84875966943     PISSN: 10423931     EISSN: 15572501     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (68)

References (21)
  • 1
    • 34250815116 scopus 로고    scopus 로고
    • Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: Device success and 30-day clinical outcome
    • Grube E, Schuler G, Buellesfeld L, et al. Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome. J Am Coll Cardiol. 2007;50(1):69-76.
    • (2007) J Am Coll Cardiol , vol.50 , Issue.1 , pp. 69-76
    • Grube, E.1    Schuler, G.2    Buellesfeld, L.3
  • 2
    • 33644860328 scopus 로고    scopus 로고
    • Percutaneous aortic valve implantation retrograde from the femoral artery
    • Webb JG, Chandavimol M, Thompson CR, et al. Percutaneous aortic valve implantation retrograde from the femoral artery. Circulation. 2006;113(6):842-850.
    • (2006) Circulation , vol.113 , Issue.6 , pp. 842-850
    • Webb, J.G.1    Chandavimol, M.2    Thompson, C.R.3
  • 3
    • 10744220322 scopus 로고    scopus 로고
    • Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis
    • Cribier A, Eltchaninoff H, Tron C, et al. Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis. J Am Coll Cardiol. 2004;43(4):698-703.
    • (2004) J Am Coll Cardiol , vol.43 , Issue.4 , pp. 698-703
    • Cribier, A.1    Eltchaninoff, H.2    Tron, C.3
  • 4
    • 33644910414 scopus 로고    scopus 로고
    • Treatment of calcific aortic stenosis with the percutaneous heart valve: Mid-term follow-up from the initial feasibility studies: The French experience
    • Cribier A, Eltchaninoff H, Tron C, et al. Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience. J Am Coll Cardiol. 2006;47(6):1214-1223.
    • (2006) J Am Coll Cardiol , vol.47 , Issue.6 , pp. 1214-1223
    • Cribier, A.1    Eltchaninoff, H.2    Tron, C.3
  • 5
    • 79251565276 scopus 로고    scopus 로고
    • Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis
    • Tamburino C, Capodanno D, Ramondo A, et al. Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation. 2011;123(3):299-308.
    • (2011) Circulation. , vol.123 , Issue.3 , pp. 299-308
    • Tamburino, C.1    Capodanno, D.2    Ramondo, A.3
  • 6
    • 84860466759 scopus 로고    scopus 로고
    • Two-year outcomes after transcatheter or surgical aortic-valve replacement
    • Kodali SK, Williams MR, Smith CR, et al. Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med. 2012;366(18):1686-1695.
    • (2012) N Engl J Med , vol.366 , Issue.18 , pp. 1686-1695
    • Kodali, S.K.1    Williams, M.R.2    Smith, C.R.3
  • 7
    • 43649086862 scopus 로고    scopus 로고
    • Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement
    • Tops LF, Wood DA, Delgado V, et al. Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. JACC Cardiovasc Imaging. 2008;1(3):321-330.
    • (2008) JACC Cardiovasc Imaging , vol.1 , Issue.3 , pp. 321-330
    • Tops, L.F.1    Wood, D.A.2    Delgado, V.3
  • 8
    • 79954492455 scopus 로고    scopus 로고
    • Multidetector computed tomography in transcatheter aortic valve implantation
    • Leipsic J, Gurvitch R, Labounty TM, et al. Multidetector computed tomography in transcatheter aortic valve implantation. JACC Cardiovasc Imaging. 2011;4(4):416-429.
    • (2011) JACC Cardiovasc Imaging , vol.4 , Issue.4 , pp. 416-429
    • Leipsic, J.1    Gurvitch, R.2    Labounty, T.M.3
  • 9
    • 77952027747 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function
    • Delgado V, Ng AC, van de Veire NR, et al. Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function. Eur Heart J. 2010;31(9):1114-1123.
    • (2010) Eur Heart J , vol.31 , Issue.9 , pp. 1114-1123
    • Delgado, V.1    Ng, A.C.2    Van De Veire, N.R.3
  • 10
    • 70349396032 scopus 로고    scopus 로고
    • Determinants of significant paravalvular regurgitation after transcatheter aortic valve: Implantation impact of device and annulus discongruence
    • Detaint D, Lepage L, Himbert D, et al. Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence. JACC Cardiovasc Interv. 2009;2(9):821-827.
    • (2009) JACC Cardiovasc Interv , vol.2 , Issue.9 , pp. 821-827
    • Detaint, D.1    Lepage, L.2    Himbert, D.3
  • 11
    • 84859160648 scopus 로고    scopus 로고
    • 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: A multicenter retrospective analysis
    • Willson AB, Webb JG, Labounty TM, et al. 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis. J Am Coll Cardiol. 2012;59(14):1287-1294.
    • (2012) J Am Coll Cardiol , vol.59 , Issue.14 , pp. 1287-1294
    • Willson, A.B.1    Webb, J.G.2    Labounty, T.M.3
  • 12
    • 49749212248 scopus 로고
    • Left retrograde cardioangiography in acquired cardiac disease: Technic, indications and interpretations in 700 cases
    • Sellers RD, Levy MJ, Amplatz K, Lillehei CW. Left retrograde cardioangiography in acquired cardiac disease: technic, indications and interpretations in 700 cases. Am J Cardiol. 1964;14:437-447.
    • (1964) Am J Cardiol , vol.14 , pp. 437-447
    • Sellers, R.D.1    Levy, M.J.2    Amplatz, K.3    Lillehei, C.W.4
  • 13
    • 78751655791 scopus 로고    scopus 로고
    • Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the Medtronic CoreValve bioprosthesis
    • Sherif MA, Abdel-Wahab M, Stocker B, et al. Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the Medtronic CoreValve bioprosthesis. J Am Coll Cardiol. 2010;56(20):1623-1629.
    • (2010) J Am Coll Cardiol. , vol.56 , Issue.20 , pp. 1623-1629
    • Sherif, M.A.1    Abdel-Wahab, M.2    Stocker, B.3
  • 14
    • 78651489907 scopus 로고    scopus 로고
    • Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: A consensus report from the Valve Academic Research Consortium
    • Leon MB, Piazza N, Nikolsky E, et al. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium. Eur Heart J. 2011;32(2):205-217.
    • (2011) Eur Heart J , vol.32 , Issue.2 , pp. 205-217
    • Leon, M.B.1    Piazza, N.2    Nikolsky, E.3
  • 15
    • 84858652989 scopus 로고    scopus 로고
    • Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation
    • Sinning JM, Hammerstingl C, Vasa-Nicotera M, et al. Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation. J Am Coll Cardiol. 2012;59(13):1134-1141.
    • (2012) J Am Coll Cardiol , vol.59 , Issue.13 , pp. 1134-1141
    • Sinning, J.M.1    Hammerstingl, C.2    Vasa-Nicotera, M.3
  • 16
    • 34547919242 scopus 로고    scopus 로고
    • Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis
    • Webb JG, Pasupati S, Humphries K, et al. Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis. Circulation. 2007;116(7):755-763.
    • (2007) Circulation , vol.116 , Issue.7 , pp. 755-763
    • Webb, J.G.1    Pasupati, S.2    Humphries, K.3
  • 17
    • 59049100066 scopus 로고    scopus 로고
    • Early echocardiographic evaluation following percutaneous implantation with the self-expanding CoreValve Revalving System aortic valve bioprosthesis
    • De Jaegere PP, Piazza N, Galema TW, et al. Early echocardiographic evaluation following percutaneous implantation with the self-expanding CoreValve Revalving System aortic valve bioprosthesis. EuroIntervention. 2008;4(3):351-357.
    • (2008) EuroIntervention , vol.4 , Issue.3 , pp. 351-357
    • De Jaegere, P.P.1    Piazza, N.2    Galema, T.W.3
  • 18
    • 79955891681 scopus 로고    scopus 로고
    • Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome. Results from the German transcatheter aortic valve interventions registry
    • Abdel-Wahab M, Zahn R, Horack M, et al. Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry. Heart. 2011;97(11):899-906.
    • (2011) Heart , vol.97 , Issue.11 , pp. 899-906
    • Abdel-Wahab, M.1    Zahn, R.2    Horack, M.3
  • 19
    • 75749129479 scopus 로고    scopus 로고
    • Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography
    • Ng AC, Delgado V, van der Kley F, et al. Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography. Circ Cardiovasc Imaging. 2010;3(1):94-102.
    • (2010) Circ Cardiovasc Imaging. , vol.3 , Issue.1 , pp. 94-102
    • Ng, A.C.1    Delgado, V.2    Van Der Kley, F.3
  • 20
    • 84856498981 scopus 로고    scopus 로고
    • Correlates on MSCT of paravalvular aortic regurgitation after transcatheter aortic valve implantation using the Medtronic CoreValve prosthesis
    • Schultz CJ, Tzikas A, Moelker A, et al. Correlates on MSCT of paravalvular aortic regurgitation after transcatheter aortic valve implantation using the Medtronic CoreValve prosthesis. Catheter Cardiovasc Interv. 2011;78(3):446-455.
    • (2011) Catheter Cardiovasc Interv , vol.78 , Issue.3 , pp. 446-455
    • Schultz, C.J.1    Tzikas, A.2    Moelker, A.3
  • 21
    • 84875982900 scopus 로고    scopus 로고
    • Patient selection for transcatheter aortic valve implantation: An interventional cardiology perspective
    • Mylotte D, Martucci G, Piazza N. Patient selection for transcatheter aortic valve implantation: an interventional cardiology perspective. Ann Cardiothorac Surg. 2012;1:206-215.
    • (2012) Ann Cardiothorac Surg. , vol.1 , pp. 206-215
    • Mylotte, D.1    Martucci, G.2    Piazza, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.