메뉴 건너뛰기




Volumn 8498 LNCS, Issue , 2014, Pages 100-107

The 'augmented' circles: A video-guided solution for the down-the-beam positioning of im nail holes

Author keywords

down the beam positioning; freehand distal locking; interlocking of intramedullary nailing; medical augmented reality; orthopedic and trauma surgery; visualization

Indexed keywords

AUGMENTED REALITY; FLOW VISUALIZATION; LOCKS (FASTENERS);

EID: 84958535931     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-319-07521-1_11     Document Type: Conference Paper
Times cited : (9)

References (10)
  • 1
    • 84995309330 scopus 로고    scopus 로고
    • Online at, http://emedicine.medscape.com/article/1248857-overview 0199
  • 4
    • 77954224040 scopus 로고    scopus 로고
    • Camera Augmented Mobile C-arm (CAMC): Calibration, accuracy study and clinical applications
    • Navab, N., Heining, S. M., Traub, J.: Camera Augmented Mobile C-arm (CAMC): Calibration, Accuracy Study and Clinical Applications. IEEE Trans. Med. Imag. 29 (7) (2009)
    • (2009) IEEE Trans. Med. Imag. , vol.29 , Issue.7
    • Navab, N.1    Heining, S.M.2    Traub, J.3
  • 5
    • 54449098074 scopus 로고    scopus 로고
    • Novel technique for distal locking of intramedullary nail based on two non-constrained fluoroscopic images and navigation
    • Leloup, T., El Kazzi, W., Schuind, F., Warzée, N.: Novel Technique for Distal Locking of Intramedullary Nail Based on Two Non-constrained Fluoroscopic Images and Navigation. IEEE Trans. Med. Imaging 27(9), 1202-1212 (2008)
    • (2008) IEEE Trans. Med. Imaging , vol.27 , Issue.9 , pp. 1202-1212
    • Leloup, T.1    El Kazzi, W.2    Schuind, F.3    Warzée, N.4
  • 6
    • 34249901541 scopus 로고    scopus 로고
    • Accurate and reliable pose recovery of distal locking holes in computer-assisted intra-medullary nailing of femoral shaft fractures: A preliminary study
    • Zheng, G., Zhang, X., Haschtmann, D., Gédet, P., Langlotz, F., Nolte, L.: Accurate and reliable pose recovery of distal locking holes in computer-assisted intra-medullary nailing of femoral shaft fractures: A preliminary study. Computer Aided Surgery 12(3), 138-151 (2007)
    • (2007) Computer Aided Surgery , vol.12 , Issue.3 , pp. 138-151
    • Zheng, G.1    Zhang, X.2    Haschtmann, D.3    Gédet, P.4    Langlotz, F.5    Nolte, L.6
  • 7
    • 80051490301 scopus 로고    scopus 로고
    • Assessment of the accuracy of infrared and electromagnetic navigation using an industrial robot: Which factors are influencing the accuracy of navigation?
    • Liodakis, E., Chu, K., Westphal, R., Krettek, C., Citak, M., Gosling, T., Kenawey, M.: Assessment of the accuracy of infrared and electromagnetic navigation using an industrial robot: Which factors are influencing the accuracy of navigation? Journal of Orthopaedic Research 29(10), 1476-1483 (2011)
    • (2011) Journal of Orthopaedic Research , vol.29 , Issue.10 , pp. 1476-1483
    • Liodakis, E.1    Chu, K.2    Westphal, R.3    Krettek, C.4    Citak, M.5    Gosling, T.6    Kenawey, M.7
  • 9
    • 84872583865 scopus 로고    scopus 로고
    • Radiation-free drill guidance in interlocking of intramedullary nails
    • Ayache, N., Delingette, H., Golland, P., Mori, K. eds., Springer, Heidelberg
    • Diotte, B., Fallavollita, P., Wang, L., Weidert, S., Thaller, P.-H., Euler, E., Navab, N.: Radiation-Free Drill Guidance in Interlocking of Intramedullary Nails. In: Ayache, N., Delingette, H., Golland, P., Mori, K. (eds.) MICCAI 2012, Part I. LNCS, vol. 7510, pp. 18-25. Springer, Heidelberg (2012)
    • (2012) MICCAI 2012, Part I. LNCS , vol.7510 , pp. 18-25
    • Diotte, B.1    Fallavollita, P.2    Wang, L.3    Weidert, S.4    Thaller, P.-H.5    Euler, E.6    Navab, N.7
  • 10
    • 80053203559 scopus 로고    scopus 로고
    • Angle estimation of simultaneous orthogonal rotations from 3D gyroscope measurements
    • doi:10.3390/s110908536
    • Stančin, S.: Angle Estimation of Simultaneous Orthogonal Rotations from 3D Gyroscope Measurements. Sensors (2011), doi:10.3390/s110908536
    • (2011) Sensors
    • Stančin, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.