메뉴 건너뛰기




Volumn 17, Issue 6, 2015, Pages 1-12

Echocardiographic Evaluation of Prosthetic Heart Valves

Author keywords

Doppler echocardiography; Prosthetic heart valves; Regurgitation; Stenosis; Transcatheter heart valves

Indexed keywords

AORTA VALVE REGURGITATION; BIOCOMPATIBILITY; BODY SURFACE; DEVICE FAILURE; DEVICE SAFETY; DOPPLER ECHOCARDIOGRAPHY; EFFECTIVE ORIFICE AREA; FOLLOW UP; HEART EJECTION FRACTION; HEART HEMODYNAMICS; HEART LEFT VENTRICLE OUTFLOW TRACT; HEART STROKE VOLUME; HEART VALVE; HEART VALVE PROSTHESIS; HUMAN; MEDICAL DEVICE COMPLICATION; MITRAL VALVE REGURGITATION; PROSTHESIS PATIENT MISMATCH; PROSTHETIC VALVE THROMBOSIS; PULSE WAVE; REVIEW; STRESS ECHOCARDIOGRAPHY; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSCATHETER VALVE STENOSIS; TRANSTHORACIC ECHOCARDIOGRAPHY; ADVERSE EFFECTS; ECHOCARDIOGRAPHY; ECHOGRAPHY; PROSTHESIS FAILURE; STATISTICS AND NUMERICAL DATA; STENOSIS, OCCLUSION AND OBSTRUCTION; THROMBOSIS; TREATMENT OUTCOME; VALVULAR HEART DISEASE;

EID: 84958182658     PISSN: 15233782     EISSN: 15343170     Source Type: Journal    
DOI: 10.1007/s11886-015-0602-z     Document Type: Review
Times cited : (8)

References (27)
  • 1
    • 20344395652 scopus 로고    scopus 로고
    • Will heart valve tissue engineering change the world?
    • COI: 1:STN:280:DC%2BD2MrosFyhug%3D%3D, PID: 16265355
    • Yacoub MH, Takkenberg JJ. Will heart valve tissue engineering change the world? Nat Clin Pract Cardiovasc Med. 2005;2:60–1.
    • (2005) Nat Clin Pract Cardiovasc Med , vol.2 , pp. 60-61
    • Yacoub, M.H.1    Takkenberg, J.J.2
  • 2
    • 84885591143 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation (TAVI): valve design and evolution
    • PID: 23972363
    • Fanning JP, Platts DG, Walters DL, Fraser JF. Transcatheter aortic valve implantation (TAVI): valve design and evolution. Int J Cardiol. 2013;168:1822–31.
    • (2013) Int J Cardiol , vol.168 , pp. 1822-1831
    • Fanning, J.P.1    Platts, D.G.2    Walters, D.L.3    Fraser, J.F.4
  • 3
    • 69549087044 scopus 로고    scopus 로고
    • Zoghbi WA, Chambers JB, Dumesnil JG, et al. Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: a report From the American Society of Echocardiography’s Guidelines and Standards Committee and the Task Force on Prosthetic Valves. J Am Soc Echocardiogr. 2009;22:975–1014. quiz 1082–4. This article represents the most recent guidelines of the American Society of Echocardiography for the Doppler-echocardiographic assessment of prosthetic valves
    • Zoghbi WA, Chambers JB, Dumesnil JG, et al. Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: a report From the American Society of Echocardiography’s Guidelines and Standards Committee and the Task Force on Prosthetic Valves. J Am Soc Echocardiogr. 2009;22:975–1014. quiz 1082–4. This article represents the most recent guidelines of the American Society of Echocardiography for the Doppler-echocardiographic assessment of prosthetic valves.
  • 4
    • 0034474806 scopus 로고    scopus 로고
    • Transesophageal echocardiographic (TEE) evaluation of prosthetic valves
    • COI: 1:STN:280:DC%2BD3M3lvVKgsg%3D%3D, PID: 11236164
    • Bach DS. Transesophageal echocardiographic (TEE) evaluation of prosthetic valves. Cardiol Clin. 2000;18:751–71.
    • (2000) Cardiol Clin , vol.18 , pp. 751-771
    • Bach, D.S.1
  • 5
    • 84884525186 scopus 로고    scopus 로고
    • Now you see it, now you don’t: 3D echocardiographic evaluation of a prosthetic aortic valve
    • PID: 24054193
    • Gerstein NS, Copeland SG, Kratzert WB, Deriy L, Windsor J. Now you see it, now you don’t: 3D echocardiographic evaluation of a prosthetic aortic valve. J Cardiothorac Vasc Anesth. 2013;27:1060–3.
    • (2013) J Cardiothorac Vasc Anesth , vol.27 , pp. 1060-1063
    • Gerstein, N.S.1    Copeland, S.G.2    Kratzert, W.B.3    Deriy, L.4    Windsor, J.5
  • 6
    • 84891697303 scopus 로고    scopus 로고
    • Dysfunction of bileaflet aortic prosthesis: accuracy of echocardiography versus fluoroscopy
    • This study shows that the difference between measured EOA and normal reference EOA as well as the ratio of acceleration time to LV ejection time are the most useful Doppler-echocardiographic parameters to identify prosthetic valve stenosis
    • Muratori M, Montorsi P, Maffessanti F, et al. Dysfunction of bileaflet aortic prosthesis: accuracy of echocardiography versus fluoroscopy. J Am Coll Cardiol Img. 2013;6:196–205. This study shows that the difference between measured EOA and normal reference EOA as well as the ratio of acceleration time to LV ejection time are the most useful Doppler-echocardiographic parameters to identify prosthetic valve stenosis.
    • (2013) J Am Coll Cardiol Img , vol.6 , pp. 196-205
    • Muratori, M.1    Montorsi, P.2    Maffessanti, F.3
  • 7
    • 61849106967 scopus 로고    scopus 로고
    • Prosthetic heart valves: selection of the optimal prosthesis and long-term management
    • PID: 19237674
    • Pibarot P, Dumesnil JG. Prosthetic heart valves: selection of the optimal prosthesis and long-term management. Circulation. 2009;119:1034–48.
    • (2009) Circulation , vol.119 , pp. 1034-1048
    • Pibarot, P.1    Dumesnil, J.G.2
  • 8
    • 34249868221 scopus 로고    scopus 로고
    • Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival
    • PID: 17533183
    • Hachicha Z, Dumesnil JG, Bogaty P, Pibarot P. Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival. Circulation. 2007;115:2856–64.
    • (2007) Circulation , vol.115 , pp. 2856-2864
    • Hachicha, Z.1    Dumesnil, J.G.2    Bogaty, P.3    Pibarot, P.4
  • 9
    • 80052572953 scopus 로고    scopus 로고
    • EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease
    • PID: 21885465, This paper presents the recommendations of the European Association of Echocardiography and American Society of Echocardiography for the Doppler-echocardiographic assessment of transcatheter heart valves and devices
    • Zamorano JL, Badano LP, Bruce C, et al. EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease. Eur Heart J. 2011;32:2189–214. This paper presents the recommendations of the European Association of Echocardiography and American Society of Echocardiography for the Doppler-echocardiographic assessment of transcatheter heart valves and devices.
    • (2011) Eur Heart J , vol.32 , pp. 2189-2214
    • Zamorano, J.L.1    Badano, L.P.2    Bruce, C.3
  • 10
    • 84879412489 scopus 로고    scopus 로고
    • Localized transvalvular pressure gradients in mitral bileaflet mechanical heart valves and impact on gradient overestimation by Doppler
    • PID: 23611059, This in vitro study provides some new insights regarding the localization and magnitude of the localized high velocities within the central orifice of mitral bileaflet mechanical valves
    • Evin M, Pibarot P, Guivier-Curien C, Tanne D, Kadem L, Rieu R. Localized transvalvular pressure gradients in mitral bileaflet mechanical heart valves and impact on gradient overestimation by Doppler. J Am Soc Echocardiogr. 2013;26:791–800. This in vitro study provides some new insights regarding the localization and magnitude of the localized high velocities within the central orifice of mitral bileaflet mechanical valves.
    • (2013) J Am Soc Echocardiogr , vol.26 , pp. 791-800
    • Evin, M.1    Pibarot, P.2    Guivier-Curien, C.3    Tanne, D.4    Kadem, L.5    Rieu, R.6
  • 11
    • 84055216928 scopus 로고    scopus 로고
    • Doppler echocardiographic evaluation of prosthetic valve function
    • PID: 22140059
    • Pibarot P, Dumesnil JG. Doppler echocardiographic evaluation of prosthetic valve function. Heart. 2012;98:69–78.
    • (2012) Heart , vol.98 , pp. 69-78
    • Pibarot, P.1    Dumesnil, J.G.2
  • 12
    • 84892925016 scopus 로고    scopus 로고
    • Accuracy of Doppler-echocardiographic parameters for the detection of aortic bileaflet mechanical prosthetic valve dysfunction
    • Smadi O, Garcia J, Pibarot P, Gaillard E, Hassan I, Kadem L. Accuracy of Doppler-echocardiographic parameters for the detection of aortic bileaflet mechanical prosthetic valve dysfunction. Eur Heart J Cardiovasc Imaging. 2014;15:142–51
    • (2014) Eur Heart J Cardiovasc Imaging , vol.15 , pp. 142-151
    • Smadi, O.1    Garcia, J.2    Pibarot, P.3    Gaillard, E.4    Hassan, I.5    Kadem, L.6
  • 13
    • 81255162882 scopus 로고    scopus 로고
    • Flow acceleration time and ratio of acceleration time to ejection time for prosthetic aortic valve function
    • Ben Zekry S, Saad RM, Ozkan M, et al. Flow acceleration time and ratio of acceleration time to ejection time for prosthetic aortic valve function. J Am Coll Cardiol Img. 2011;4:1161–70.
    • (2011) J Am Coll Cardiol Img , vol.4 , pp. 1161-1170
    • Ben Zekry, S.1    Saad, R.M.2    Ozkan, M.3
  • 14
    • 84873634842 scopus 로고    scopus 로고
    • ApoB/ApoA-I ratio is associated with increased risk of bioprosthetic valve degeneration
    • COI: 1:CAS:528:DC%2BC3sXisVaksrY%3D, PID: 23410546
    • Mahjoub H, Mathieu P, Senechal M, et al. ApoB/ApoA-I ratio is associated with increased risk of bioprosthetic valve degeneration. J Am Coll Cardiol. 2013;61:752–61.
    • (2013) J Am Coll Cardiol , vol.61 , pp. 752-761
    • Mahjoub, H.1    Mathieu, P.2    Senechal, M.3
  • 15
    • 70549098124 scopus 로고    scopus 로고
    • The emerging role of exercise testing and stress echocardiography in valvular heart disease
    • PID: 19958961
    • Picano E, Pibarot P, Lancellotti P, Monin JL, Bonow RO. The emerging role of exercise testing and stress echocardiography in valvular heart disease. J Am Coll Cardiol. 2009;54:2251–60.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 2251-2260
    • Picano, E.1    Pibarot, P.2    Lancellotti, P.3    Monin, J.L.4    Bonow, R.O.5
  • 16
    • 84901633328 scopus 로고    scopus 로고
    • Hemodynamic performance during exercise of the new St. Jude Trifecta aortic bioprosthesis: results from a French multicenter study
    • PID: 24656322
    • Levy F, Donal E, Biere L, et al. Hemodynamic performance during exercise of the new St. Jude Trifecta aortic bioprosthesis: results from a French multicenter study. J Am Soc Echocardiogr. 2014;27:590–7.
    • (2014) J Am Soc Echocardiogr , vol.27 , pp. 590-597
    • Levy, F.1    Donal, E.2    Biere, L.3
  • 17
    • 0027075062 scopus 로고
    • Comparison of transthoracic and transesophageal echocardiography in evaluation of 47 Starr-Edwards prosthetic valves
    • COI: 1:STN:280:DyaK3s%2FosFSmug%3D%3D, PID: 1452923
    • Alton ME, Pasierski TJ, Orsinelli DA, Eaton GM, Pearson AC. Comparison of transthoracic and transesophageal echocardiography in evaluation of 47 Starr-Edwards prosthetic valves. J Am Coll Cardiol. 1992;20:1503–11.
    • (1992) J Am Coll Cardiol , vol.20 , pp. 1503-1511
    • Alton, M.E.1    Pasierski, T.J.2    Orsinelli, D.A.3    Eaton, G.M.4    Pearson, A.C.5
  • 18
    • 0025332554 scopus 로고
    • Comparison of transthoracic and transesophageal assessment of prosthetic valve dysfunction
    • COI: 1:STN:280:DyaK38bgtVGlsw%3D%3D, PID: 10149194
    • Daniel LB, Grigg LE, Weisel RD, Rakowski H. Comparison of transthoracic and transesophageal assessment of prosthetic valve dysfunction. Echocardiography. 1990;7:83–95.
    • (1990) Echocardiography , vol.7 , pp. 83-95
    • Daniel, L.B.1    Grigg, L.E.2    Weisel, R.D.3    Rakowski, H.4
  • 19
    • 1942436241 scopus 로고    scopus 로고
    • Assessment of severity of mechanical prosthetic mitral regurgitation by transoesophageal echocardiography
    • COI: 1:STN:280:DC%2BD2c7ovVyhug%3D%3D, PID: 15084553
    • Vitarelli A, Conde Y, Cimino E, et al. Assessment of severity of mechanical prosthetic mitral regurgitation by transoesophageal echocardiography. Heart. 2004;90:539–44.
    • (2004) Heart , vol.90 , pp. 539-544
    • Vitarelli, A.1    Conde, Y.2    Cimino, E.3
  • 20
    • 84867283287 scopus 로고    scopus 로고
    • Guidelines on the management of valvular heart disease (version 2012)
    • PID: 22922415
    • Vahanian A, Alfieri O, Andreotti F, et al. Guidelines on the management of valvular heart disease (version 2012). Eur Heart J. 2012;33:2451–96.
    • (2012) Eur Heart J , vol.33 , pp. 2451-2496
    • Vahanian, A.1    Alfieri, O.2    Andreotti, F.3
  • 21
    • 84893710306 scopus 로고    scopus 로고
    • Incremental value of 3-D transesophageal echocardiographic imaging of the mitral valve
    • PID: 24292888
    • Jain S, Malouf JF. Incremental value of 3-D transesophageal echocardiographic imaging of the mitral valve. Curr Cardiol Rep. 2014;16:439.
    • (2014) Curr Cardiol Rep , vol.16 , pp. 439
    • Jain, S.1    Malouf, J.F.2
  • 22
    • 84859567725 scopus 로고    scopus 로고
    • A practical guide to multimodality imaging of transcatheter aortic valve replacement
    • Bloomfield GS, Gillam LD, Hahn RT, et al. A practical guide to multimodality imaging of transcatheter aortic valve replacement. J Am Coll Cardiol Img. 2012;5:441–55.
    • (2012) J Am Coll Cardiol Img , vol.5 , pp. 441-455
    • Bloomfield, G.S.1    Gillam, L.D.2    Hahn, R.T.3
  • 23
    • 80054105495 scopus 로고    scopus 로고
    • Validation and characterization of transcatheter aortic valve effective orifice area measured by Doppler echocardiography
    • This is the first validation of the method to measure the EOA of transcatheter aortic valves by Doppler-echocardiography
    • Clavel MA, Rodes-Cabau J, Dumont E, et al. Validation and characterization of transcatheter aortic valve effective orifice area measured by Doppler echocardiography. J Am Coll Cardiol Img. 2011;4:1053–62. This is the first validation of the method to measure the EOA of transcatheter aortic valves by Doppler-echocardiography.
    • (2011) J Am Coll Cardiol Img , vol.4 , pp. 1053-1062
    • Clavel, M.A.1    Rodes-Cabau, J.2    Dumont, E.3
  • 24
    • 84871211131 scopus 로고    scopus 로고
    • Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document
    • PID: 23084102, This article presents the recommendations for the Doppler-echocardiographic assessment of transcatheter aortic valves
    • Kappetein AP, Head SJ, Genereux P, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. J Thorac Cardiovasc Surg. 2013;145:6–23. This article presents the recommendations for the Doppler-echocardiographic assessment of transcatheter aortic valves.
    • (2013) J Thorac Cardiovasc Surg , vol.145 , pp. 6-23
    • Kappetein, A.P.1    Head, S.J.2    Genereux, P.3
  • 25
    • 84875975723 scopus 로고    scopus 로고
    • Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature
    • PID: 23500308, This meta-analysis reports the prevalence and impact on prognosis of paravalvular regurgitation following TAVI
    • Athappan G, Patvardhan E, Tuzcu EM, et al. Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol. 2013;61:1585–95. This meta-analysis reports the prevalence and impact on prognosis of paravalvular regurgitation following TAVI.
    • (2013) J Am Coll Cardiol , vol.61 , pp. 1585-1595
    • Athappan, G.1    Patvardhan, E.2    Tuzcu, E.M.3
  • 26
    • 84922482081 scopus 로고    scopus 로고
    • Cardiac magnetic resonance versus transthoracic echocardiography for the assessment and quantification of aortic regurgitation in patients undergoing transcatheter aortic valve implantation
    • Ribeiro HB, Le Ven F, Larose E et al. Cardiac magnetic resonance versus transthoracic echocardiography for the assessment and quantification of aortic regurgitation in patients undergoing transcatheter aortic valve implantation. Heart. 2014;100:1924–32.
    • (2014) Heart , vol.100 , pp. 1924-1932
    • Ribeiro, H.B.1    Le Ven, F.2    Larose, E.3
  • 27
    • 84155167086 scopus 로고    scopus 로고
    • Three-dimensional echocardiography in paravalvular aortic regurgitation assessment after transcatheter aortic valve implantation
    • PID: 21962448
    • Goncalves A, Almeria C, Marcos-Alberca P, et al. Three-dimensional echocardiography in paravalvular aortic regurgitation assessment after transcatheter aortic valve implantation. J Am Soc Echocardiogr. 2012;25:47–55.
    • (2012) J Am Soc Echocardiogr , vol.25 , pp. 47-55
    • Goncalves, A.1    Almeria, C.2    Marcos-Alberca, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.