메뉴 건너뛰기




Volumn 27, Issue 6, 2014, Pages 590-597

Hemodynamic performance during exercise of the new St. Jude trifecta aortic bioprosthesis: Results from a French multicenter study

Author keywords

Bioprosthesis; Echocardiography; Exercise

Indexed keywords

AGED; AORTA BIOPROSTHESIS; AORTA PROSTHESIS; AORTA STENOSIS; AORTA VALVE REPLACEMENT; ARTICLE; BIOPROSTHESIS; CARDIOPULMONARY BYPASS; CORONARY ARTERY BYPASS GRAFT; DOPPLER ECHOCARDIOGRAPHY; EXERCISE; EXERCISE INTENSITY; FEMALE; HEART LEFT VENTRICLE EJECTION FRACTION; HEMODYNAMIC PARAMETERS; HUMAN; MAJOR CLINICAL STUDY; MALE; MULTICENTER STUDY; AORTA VALVE; AORTIC VALVE STENOSIS; CLINICAL TRIAL; ECHOGRAPHY; HEART VALVE PROSTHESIS; HEMODYNAMICS; PATHOPHYSIOLOGY; PHYSIOLOGY; PROSTHESIS; VERY ELDERLY;

EID: 84901633328     PISSN: 08947317     EISSN: 10976795     Source Type: Journal    
DOI: 10.1016/j.echo.2014.01.022     Document Type: Article
Times cited : (27)

References (18)
  • 1
    • 33746393625 scopus 로고    scopus 로고
    • Prosthesis patient mismatch: Definition, clinical impact, and prevention
    • P. Pibarot, and J. Dumesnil Prosthesis patient mismatch: definition, clinical impact, and prevention Heart 92 2006 1022 1029
    • (2006) Heart , vol.92 , pp. 1022-1029
    • Pibarot, P.1    Dumesnil, J.2
  • 2
    • 0031971981 scopus 로고    scopus 로고
    • Impact of prosthesis-patient mismatch on hemodynamic and symptomatic status, morbidity and mortality after aoric valve replacement with a bioprosthetic heart valve
    • P. Pibarot, J. Dusmenil, M. Lemieux, P. Cartier, J. Metras, and L. Durand Impact of prosthesis-patient mismatch on hemodynamic and symptomatic status, morbidity and mortality after aoric valve replacement with a bioprosthetic heart valve J Heart valve Dis 7 1998 211 218
    • (1998) J Heart Valve Dis , vol.7 , pp. 211-218
    • Pibarot, P.1    Dusmenil, J.2    Lemieux, M.3    Cartier, P.4    Metras, J.5    Durand, L.6
  • 3
    • 84872721209 scopus 로고    scopus 로고
    • Clinical and echocardiographic outcomes after implantation of the Trifecta aortic bioprosthesis: An initial single-centre experience
    • A. Dell'Aquila, D. Schlarb, S. Schneider, J. Sindermann, A. Hoffmeier, and G. Kaleschke et al. Clinical and echocardiographic outcomes after implantation of the Trifecta aortic bioprosthesis: an initial single-centre experience Interact Cardiovasc Thorac Surg 16 2013 112 115
    • (2013) Interact Cardiovasc Thorac Surg , vol.16 , pp. 112-115
    • Dell'Aquila, A.1    Schlarb, D.2    Schneider, S.3    Sindermann, J.4    Hoffmeier, A.5    Kaleschke, G.6
  • 4
    • 84892372695 scopus 로고    scopus 로고
    • The St Jude Medical Trifecta aortic pericardial valve: Results from a global, multicenter, prospective clinical study
    • J.E. Bavaria, N.D. Desai, A. Cheung, M.R. Petracek, M.A. Groh, and M.A. Borger et al. The St Jude Medical Trifecta aortic pericardial valve: results from a global, multicenter, prospective clinical study J Thorac Cardiovasc Surg 147 2014 590 597
    • (2014) J Thorac Cardiovasc Surg , vol.147 , pp. 590-597
    • Bavaria, J.E.1    Desai, N.D.2    Cheung, A.3    Petracek, M.R.4    Groh, M.A.5    Borger, M.A.6
  • 5
    • 67650872879 scopus 로고    scopus 로고
    • Effects of age on pulmonary artery systolic pressure at rest and during exercise in normal adults
    • H. Mahjoub, F. Levy, M. Cassol, P. Meimoun, M. Peltier, and D. Rusinaru et al. Effects of age on pulmonary artery systolic pressure at rest and during exercise in normal adults Eur J Echocardiogr 10 2009 635 640
    • (2009) Eur J Echocardiogr , vol.10 , pp. 635-640
    • Mahjoub, H.1    Levy, F.2    Cassol, M.3    Meimoun, P.4    Peltier, M.5    Rusinaru, D.6
  • 6
    • 0024723470 scopus 로고
    • Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms
    • N. Schiller, P. Shah, M. Crawford, A. DeMaria, R. Devereux, and H. Feigenbaum et al. Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms J Am Soc Echocardiograph 2 1989 358 367
    • (1989) J Am Soc Echocardiograph , vol.2 , pp. 358-367
    • Schiller, N.1    Shah, P.2    Crawford, M.3    Demaria, A.4    Devereux, R.5    Feigenbaum, H.6
  • 7
    • 29244432482 scopus 로고    scopus 로고
    • Recommendations for chamber quantification: A report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology
    • R. Lang, M. Bierig, R. Devereux, F. Flachskampf, E. Foster, and P. Pellikka et al. Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology J Am Soc Echocardiogr 18 2005 1440 1463
    • (2005) J Am Soc Echocardiogr , vol.18 , pp. 1440-1463
    • Lang, R.1    Bierig, M.2    Devereux, R.3    Flachskampf, F.4    Foster, E.5    Pellikka, P.6
  • 8
    • 0021173362 scopus 로고
    • Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: Clinical validation of two new methods using the apical window
    • J. Lewis, L. Kuo, J. Nelson, M. Limacher, and M. Quinones Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window Circulation 70 1984 425 431
    • (1984) Circulation , vol.70 , pp. 425-431
    • Lewis, J.1    Kuo, L.2    Nelson, J.3    Limacher, M.4    Quinones, M.5
  • 9
    • 0021816125 scopus 로고
    • Continuous-wave Doppler echocardiographic assessment of severity of calcific aortic stenosis: A simultaneous Doppler-catheter correlative study in 100 adult patients
    • P.J. Currie, J.B. Seward, G.S. Reeder, R.E. Vlietstra, D.R. Bresnahan, and J.F. Bresnahan et al. Continuous-wave Doppler echocardiographic assessment of severity of calcific aortic stenosis: a simultaneous Doppler-catheter correlative study in 100 adult patients Circulation 71 1985 1162 1169
    • (1985) Circulation , vol.71 , pp. 1162-1169
    • Currie, P.J.1    Seward, J.B.2    Reeder, G.S.3    Vlietstra, R.E.4    Bresnahan, D.R.5    Bresnahan, J.F.6
  • 10
    • 0022355265 scopus 로고
    • Noninvasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography
    • T. Skjaerpe, L. Hegrenaes, and L. Hatle Noninvasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography Circulation 72 1985 810 818
    • (1985) Circulation , vol.72 , pp. 810-818
    • Skjaerpe, T.1    Hegrenaes, L.2    Hatle, L.3
  • 11
    • 0042859863 scopus 로고    scopus 로고
    • Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement
    • C. Blais, J. Dumesnil, R. Baillot, S. Simard, D. Doyle, and P. Pibarot Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement Circulation 108 2003 983 988
    • (2003) Circulation , vol.108 , pp. 983-988
    • Blais, C.1    Dumesnil, J.2    Baillot, R.3    Simard, S.4    Doyle, D.5    Pibarot, P.6
  • 12
    • 18244372666 scopus 로고    scopus 로고
    • Exercise hemodynamics of bovine versus porcine bioprostheses: A prospective randomized comparison of the Mosaic and Perimount aortic valves
    • W.B. Eichinger, F. Botzenhardt, A. Keithahn, R. Guenzinger, S. Bleiziffer, and I. Wagner et al. Exercise hemodynamics of bovine versus porcine bioprostheses: a prospective randomized comparison of the Mosaic and Perimount aortic valves J Thorac Cardiovasc Surg 129 2005 1056 1063
    • (2005) J Thorac Cardiovasc Surg , vol.129 , pp. 1056-1063
    • Eichinger, W.B.1    Botzenhardt, F.2    Keithahn, A.3    Guenzinger, R.4    Bleiziffer, S.5    Wagner, I.6
  • 13
    • 0034109387 scopus 로고    scopus 로고
    • Comparative rest and exercise hemodynamics of 23-mm stentless versus 23-mm stented aortic bioprostheses
    • R. Fries, O. Wendler, H. Schieffer, and H. Schäfers Comparative rest and exercise hemodynamics of 23-mm stentless versus 23-mm stented aortic bioprostheses Ann Thorac Surg 69 2000 817 822
    • (2000) Ann Thorac Surg , vol.69 , pp. 817-822
    • Fries, R.1    Wendler, O.2    Schieffer, H.3    Schäfers, H.4
  • 14
    • 72849115650 scopus 로고    scopus 로고
    • Exercise echocardiography in cryopreserved aortic homografts: Comparison of a prototype stentless, a stented bioprosthesis, and native aortic valves
    • A. Cordovil, O. Campos Filho, J. de Andrade, A. Rodrigues, L. Gerola, and V. Moises et al. Exercise echocardiography in cryopreserved aortic homografts: comparison of a prototype stentless, a stented bioprosthesis, and native aortic valves Echocardiography 26 2009 1204 1210
    • (2009) Echocardiography , vol.26 , pp. 1204-1210
    • Cordovil, A.1    Campos Filho, O.2    De Andrade, J.3    Rodrigues, A.4    Gerola, L.5    Moises, V.6
  • 15
    • 84877265392 scopus 로고    scopus 로고
    • Prognostic significance of exercise-induced right ventricular dysfunction in asymptomatic degenerative mitral regurgitation
    • K. Kusunose, Z.B. Popovic, H. Motoki, and T.H. Marwick Prognostic significance of exercise-induced right ventricular dysfunction in asymptomatic degenerative mitral regurgitation Circ Cardiovasc Imaging 6 2013 167 176
    • (2013) Circ Cardiovasc Imaging , vol.6 , pp. 167-176
    • Kusunose, K.1    Popovic, Z.B.2    Motoki, H.3    Marwick, T.H.4
  • 16
    • 0033231145 scopus 로고    scopus 로고
    • Hemodynamic and physical performance during maximal exercise in patients with an aortic bioprosthetic valve: Comparison of stentless versus stented bioprostheses
    • P. Pibarot, J. Dumesnil, J. Jobin, P. Cartier, G. Honos, and L. Durand Hemodynamic and physical performance during maximal exercise in patients with an aortic bioprosthetic valve: comparison of stentless versus stented bioprostheses J Am Coll Cardiol 34 1999 1609 1617
    • (1999) J Am Coll Cardiol , vol.34 , pp. 1609-1617
    • Pibarot, P.1    Dumesnil, J.2    Jobin, J.3    Cartier, P.4    Honos, G.5    Durand, L.6
  • 17
    • 29344463664 scopus 로고    scopus 로고
    • Flow-dependent changes in Doppler-derived aortic valve effective orifice area are real and not due to artifact
    • L. Kadem, R. Rieu, J. Dumesnil, L. Durand, and P. Pibarot Flow-dependent changes in Doppler-derived aortic valve effective orifice area are real and not due to artifact J Am Coll Cardiol 47 2006 131 137
    • (2006) J Am Coll Cardiol , vol.47 , pp. 131-137
    • Kadem, L.1    Rieu, R.2    Dumesnil, J.3    Durand, L.4    Pibarot, P.5
  • 18
    • 0025552864 scopus 로고
    • Discrepancies between Doppler and catheter gradients in aortic prosthetic valves in vitro. A manifestation of localized gradients and pressure recovery
    • H. Baumgartner, S. Khan, M. DeRobertis, L. Czer, and G. Maurer Discrepancies between Doppler and catheter gradients in aortic prosthetic valves in vitro. A manifestation of localized gradients and pressure recovery Circulation 82 1990 1467 1475
    • (1990) Circulation , vol.82 , pp. 1467-1475
    • Baumgartner, H.1    Khan, S.2    Derobertis, M.3    Czer, L.4    Maurer, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.