메뉴 건너뛰기




Volumn 4, Issue 10, 2011, Pages 1053-1062

Validation and characterization of transcatheter aortic valve effective orifice area measured by doppler echocardiography

Author keywords

aortic stenosis; echocardiography; prosthesis; transcatheter; valves

Indexed keywords

AGED; AORTA STENOSIS; ARTICLE; DOPPLER ECHOCARDIOGRAPHY; HEART VALVE; HEART VALVE PROSTHESIS; HEMODYNAMICS; HOSPITAL DISCHARGE; HUMAN; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSTHORACIC ECHOCARDIOGRAPHY; VALIDATION STUDY;

EID: 80054105495     PISSN: 1936878X     EISSN: 18767591     Source Type: Journal    
DOI: 10.1016/j.jcmg.2011.06.021     Document Type: Article
Times cited : (86)

References (24)
  • 1
    • 61849106967 scopus 로고    scopus 로고
    • Prosthetic heart valves: Selection of the optimal prosthesis and long-term management
    • P. Pibarot, and J.G. Dumesnil Prosthetic heart valves: selection of the optimal prosthesis and long-term management Circulation 119 2009 1034 1048
    • (2009) Circulation , vol.119 , pp. 1034-1048
    • Pibarot, P.1    Dumesnil, J.G.2
  • 2
    • 69549087044 scopus 로고    scopus 로고
    • Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: A report from the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves
    • W.A. Zoghbi, J.B. Chambers, and J.G. Dumesnil Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves J Am Soc Echocardiogr 22 2009 975 1014
    • (2009) J Am Soc Echocardiogr , vol.22 , pp. 975-1014
    • Zoghbi, W.A.1    Chambers, J.B.2    Dumesnil, J.G.3
  • 4
    • 77950526783 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-CoreValve bioprosthesis
    • H. Jilaihawi, D. Chin, and T. Spyt Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-CoreValve bioprosthesis Eur Heart J 31 2010 857 864
    • (2010) Eur Heart J , vol.31 , pp. 857-864
    • Jilaihawi, H.1    Chin, D.2    Spyt, T.3
  • 5
    • 65149088915 scopus 로고    scopus 로고
    • Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis
    • M.A. Clavel, J.G. Webb, and P. Pibarot Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis J Am Coll Cardiol 53 2009 1883 1891
    • (2009) J Am Coll Cardiol , vol.53 , pp. 1883-1891
    • Clavel, M.A.1    Webb, J.G.2    Pibarot, P.3
  • 6
    • 77955691974 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch after transcatheter aortic valve implantation with the medtronic CoreValve system in patients with aortic stenosis
    • A. Tzikas, N. Piazza, and M.L. Geleijnse Prosthesis-patient mismatch after transcatheter aortic valve implantation with the medtronic CoreValve system in patients with aortic stenosis Am J Cardiol 106 2010 255 260
    • (2010) Am J Cardiol , vol.106 , pp. 255-260
    • Tzikas, A.1    Piazza, N.2    Geleijnse, M.L.3
  • 7
    • 0034700972 scopus 로고    scopus 로고
    • Assessment of aortic valve stenosis severity: A new index based on the energy loss concept
    • D. Garcia, P. Pibarot, J.G. Dumesnil, F. Sakr, and L.G. Durand Assessment of aortic valve stenosis severity: a new index based on the energy loss concept Circulation 101 2000 765 771 (Pubitemid 30100083)
    • (2000) Circulation , vol.101 , Issue.7 , pp. 765-771
    • Garcia, D.1    Pibarot, P.2    Dumesnil, J.G.3    Sakr, F.4    Durand, L.-G.5
  • 8
    • 33846887146 scopus 로고    scopus 로고
    • Low-flow, low-gradient aortic stenosis: From evaluation to treatment
    • DOI 10.1097/HCO.0b013e32801466f5, PII 0000157320070300000007
    • I.G. Burwash Low-flow, low-gradient aortic stenosis: from evaluation to treatment Curr Opin Cardiol 22 2007 84 91 (Pubitemid 46220261)
    • (2007) Current Opinion in Cardiology , vol.22 , Issue.2 , pp. 84-91
    • Burwash, I.G.1
  • 9
    • 34249868221 scopus 로고    scopus 로고
    • Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival
    • DOI 10.1161/CIRCULATIONAHA.106.668681
    • Z. Hachicha, J.G. Dumesnil, P. Bogaty, and P. Pibarot Paradoxical low flow, low gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival Circulation 115 2007 2856 2864 (Pubitemid 46869673)
    • (2007) Circulation , vol.115 , Issue.22 , pp. 2856-2864
    • Hachicha, Z.1    Dumesnil, J.G.2    Bogaty, P.3    Pibarot, P.4
  • 10
    • 77957108299 scopus 로고    scopus 로고
    • Inconsistent grading of aortic valve stenosis by current guidelines: Haemodynamic studies in patients with apparently normal left ventricular function
    • J. Minners, M. Allgeier, C. Gohlke-Baerwolf, R.P. Kienzle, F.J. Neumann, and N. Jander Inconsistent grading of aortic valve stenosis by current guidelines: haemodynamic studies in patients with apparently normal left ventricular function Heart 96 2010 1463 1468
    • (2010) Heart , vol.96 , pp. 1463-1468
    • Minners, J.1    Allgeier, M.2    Gohlke-Baerwolf, C.3    Kienzle, R.P.4    Neumann, F.J.5    Jander, N.6
  • 11
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • J.M. Bland, and D.G. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 1986 307 310 (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0022355265 scopus 로고
    • Noninvasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography
    • T. Skjaerpe, L. Hegrenaes, and L. Hatle Noninvasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography Circulation 72 1985 810 818 (Pubitemid 16245191)
    • (1985) Circulation , vol.72 , Issue.4 , pp. 810-818
    • Skjaerpe, T.1    Hegrenaes, L.2    Hatle, L.3
  • 13
    • 0022649162 scopus 로고
    • Determination of the stenotic aortic valve area in adults using Doppler echocardiography
    • C.M. Otto, A.S. Pearlman, K.A. Comess, R.P. Reamer, C.L. Janko, and L.L. Huntsman Determination of the stenotic aortic valve area in adults using Doppler echocardiography J Am Coll Cardiol 7 1986 509 517 (Pubitemid 16164377)
    • (1986) Journal of the American College of Cardiology , vol.7 , Issue.3 , pp. 509-517
    • Otto, C.M.1    Pearlman, A.S.2    Comess, K.A.3
  • 14
    • 0030136999 scopus 로고    scopus 로고
    • An echocardiographic approach to the assessment of aortic stenosis
    • J.E. Bednarz, D. Krauss, and R.M. Lang An echocardiographic approach to the assessment of aortic stenosis J Am Soc Echocardiogr 9 1996 286 294
    • (1996) J Am Soc Echocardiogr , vol.9 , pp. 286-294
    • Bednarz, J.E.1    Krauss, D.2    Lang, R.M.3
  • 15
    • 0141468886 scopus 로고    scopus 로고
    • Valvular heart disease
    • R.W. Weinberg, L.A. Simmons, R. Madrigal, Lippincott-Raven Philadelphia, PA
    • J.K. Oh, J.B. Seward, and A.J. Tajik Valvular heart disease R.W. Weinberg, L.A. Simmons, R. Madrigal, The Echo Manual 1999 Lippincott-Raven Philadelphia, PA 103 132
    • (1999) The Echo Manual , pp. 103-132
    • Oh, J.K.1    Seward, J.B.2    Tajik, A.J.3
  • 16
    • 58149204388 scopus 로고    scopus 로고
    • Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice
    • H. Baumgartner, J. Hung, and J. Bermejo Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice J Am Soc Echocardiogr 22 2009 1 23
    • (2009) J Am Soc Echocardiogr , vol.22 , pp. 1-23
    • Baumgartner, H.1    Hung, J.2    Bermejo, J.3
  • 17
    • 77957945557 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Durability of clinical and hemodynamic outcomes beyond 3 years in a large patient cohort
    • R. Gurvitch, D.A. Wood, and E.L. Tay Transcatheter aortic valve implantation: durability of clinical and hemodynamic outcomes beyond 3 years in a large patient cohort Circulation 122 2010 1319 1327
    • (2010) Circulation , vol.122 , pp. 1319-1327
    • Gurvitch, R.1    Wood, D.A.2    Tay, E.L.3
  • 19
    • 67650088413 scopus 로고    scopus 로고
    • Results of transfemoral or transapical aortic valve implantation following a uniform assessment in high-risk patients with aortic stenosis
    • D. Himbert, F. Descoutures, and N. Al Attar Results of transfemoral or transapical aortic valve implantation following a uniform assessment in high-risk patients with aortic stenosis J Am Coll Cardiol 54 2009 303 311
    • (2009) J Am Coll Cardiol , vol.54 , pp. 303-311
    • Himbert, D.1    Descoutures, F.2    Al Attar, N.3
  • 20
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • M.B. Leon, C.R. Smith, and M. Mack Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery N Engl J Med 363 2010 1597 1607
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    MacK, M.3
  • 21
    • 57949105389 scopus 로고    scopus 로고
    • Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: Influence of age, obesity, and left ventricular dysfunction
    • D. Mohty, J.G. Dumesnil, and N. Echahidi Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: influence of age, obesity, and left ventricular dysfunction J Am Coll Cardiol 53 2009 39 47
    • (2009) J Am Coll Cardiol , vol.53 , pp. 39-47
    • Mohty, D.1    Dumesnil, J.G.2    Echahidi, N.3
  • 24
    • 75749129479 scopus 로고    scopus 로고
    • Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography
    • A.C. Ng, V. Delgado, and K.F. van der Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography Circ Cardiovasc Imaging 3 2010 94 102
    • (2010) Circ Cardiovasc Imaging , vol.3 , pp. 94-102
    • Ng, A.C.1    Delgado, V.2    Van Der, K.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.