메뉴 건너뛰기




Volumn 35, Issue 2, 2016, Pages 219-258

Fourier transform ion cyclotron resonance (FT ICR) mass spectrometry: Theory and simulations

Author keywords

FT ICR; MS; non neutral plasma; simulation

Indexed keywords

CYCLOTRON RESONANCE; CYCLOTRONS; ELECTRON CYCLOTRON RESONANCE; MASS SPECTROMETERS; MASS SPECTROMETRY; MOLECULAR BIOLOGY; SIGNAL PROCESSING; SPECTROMETERS; SUPERCOMPUTERS;

EID: 84957435480     PISSN: 02777037     EISSN: 10982787     Source Type: Journal    
DOI: 10.1002/mas.21422     Document Type: Review
Times cited : (155)

References (115)
  • 1
    • 57449121190 scopus 로고    scopus 로고
    • Rodgers Petroleomics: Chemistry of the underworld
    • Alan G. Marshall, Ryan P,. 2008. Rodgers Petroleomics: Chemistry of the underworld. Proc Natl Acad Sci USA 105 (47): 18090-18095.
    • (2008) Proc Natl Acad Sci USA , vol.105 , Issue.47 , pp. 18090-18095
    • Alan, G.M.1    Ryan, P.2
  • 3
    • 36849118375 scopus 로고
    • Electrical current shims for correcting magnetic fields
    • Anderson WA,. 1961. Electrical current shims for correcting magnetic fields. Rev Sci Instrum 32 (3): 241-250.
    • (1961) Rev Sci Instrum , vol.32 , Issue.3 , pp. 241-250
    • Anderson, W.A.1
  • 4
    • 0000244140 scopus 로고    scopus 로고
    • Experimental methods to alleviate ion coupling effects in matrix-assisted laser desorption ionization Fourier transform ion cyclotron resonance mass spectrometry
    • Anderson JS, Laude DA,. 1996. Experimental methods to alleviate ion coupling effects in matrix-assisted laser desorption ionization Fourier transform ion cyclotron resonance mass spectrometry. Int J Mass Spectrom Ion Processes 157: 163-174.
    • (1996) Int J Mass Spectrom Ion Processes , vol.157 , pp. 163-174
    • Anderson, J.S.1    Laude, D.A.2
  • 5
    • 59649116308 scopus 로고    scopus 로고
    • Simulation of ion trajectories using the surface-charge method on a special purpose computer
    • Aoki J, Kubo A, Ishihara M, Toyoda M,. 2009. Simulation of ion trajectories using the surface-charge method on a special purpose computer. Nucl Instrum Methods Phys Res Sect A 600 (2): 466-470.
    • (2009) Nucl Instrum Methods Phys Res Sect A , vol.600 , Issue.2 , pp. 466-470
    • Aoki, J.1    Kubo, A.2    Ishihara, M.3    Toyoda, M.4
  • 6
    • 0014422511 scopus 로고
    • Ion cyclotron resonance spectroscopy
    • Baldeschwieler JD,. 1968. Ion cyclotron resonance spectroscopy. Science 159 (3812): 263-273.
    • (1968) Science , vol.159 , Issue.3812 , pp. 263-273
    • Baldeschwieler, J.D.1
  • 7
    • 0036943308 scopus 로고    scopus 로고
    • Linearizing" an ion cyclotron resonance cell
    • Barlow SE, Tinkle MD,. 2002. " Linearizing" an ion cyclotron resonance cell. Rev Sci Instrum 73 (12): 4185-4200.
    • (2002) Rev Sci Instrum , vol.73 , Issue.12 , pp. 4185-4200
    • Barlow, S.E.1    Tinkle, M.D.2
  • 8
    • 30844435912 scopus 로고    scopus 로고
    • The ion cyclotron resonance frequency of short, single-species plasmas in Penning traps
    • Barlow SE, Tinkle MD,. 2006. The ion cyclotron resonance frequency of short, single-species plasmas in Penning traps. J Appl Phys 99 (1): 013306-013306.
    • (2006) J Appl Phys , vol.99 , Issue.1 , pp. 013306
    • Barlow, S.E.1    Tinkle, M.D.2
  • 9
    • 0026140546 scopus 로고
    • Particle-in-cell charged-particle simulations, plus Monte Carlo collisions with neutral atoms, PIC-MCC
    • Birdsall CK,. 1991. Particle-in-cell charged-particle simulations, plus Monte Carlo collisions with neutral atoms, PIC-MCC. IEEE Trans Plasma Sci 19 (2): 65-85.
    • (1991) IEEE Trans Plasma Sci , vol.19 , Issue.2 , pp. 65-85
    • Birdsall, C.K.1
  • 11
    • 14744304574 scopus 로고    scopus 로고
    • Proteomics by FTICR mass spectrometry: Top down and bottom up
    • Bogdanov B, Smith RD,. 2005. Proteomics by FTICR mass spectrometry: Top down and bottom up. Mass Spectrom Rev 24 (2): 168-200.
    • (2005) Mass Spectrom Rev , vol.24 , Issue.2 , pp. 168-200
    • Bogdanov, B.1    Smith, R.D.2
  • 12
    • 70350510309 scopus 로고    scopus 로고
    • Theory of peak coalescence in Fourier transform ion cyclotron resonance mass spectrometry
    • Boldin IA, Nikolaev EN,. 2009. Theory of peak coalescence in Fourier transform ion cyclotron resonance mass spectrometry. Rapid Commun Mass Spectrom 23 (19): 3213-3219.
    • (2009) Rapid Commun Mass Spectrom , vol.23 , Issue.19 , pp. 3213-3219
    • Boldin, I.A.1    Nikolaev, E.N.2
  • 13
    • 78650136454 scopus 로고    scopus 로고
    • Fourier transform ion cyclotron resonance cell with dynamic harmonization of the electric field in the whole volume by shaping of the excitation and detection electrode assembly
    • Boldin IA, Nikolaev EN,. 2011. Fourier transform ion cyclotron resonance cell with dynamic harmonization of the electric field in the whole volume by shaping of the excitation and detection electrode assembly. Rapid Commun Mass Spectrom 25 (1): 122-126.
    • (2011) Rapid Commun Mass Spectrom , vol.25 , Issue.1 , pp. 122-126
    • Boldin, I.A.1    Nikolaev, E.N.2
  • 15
    • 34250900735 scopus 로고
    • Geonium theory: Physics of a single electron or ion in a Penning trap
    • Brown LS, Gabrielse G,. 1986. Geonium theory: Physics of a single electron or ion in a Penning trap. Rev Modern Phys 58 (1): 233.
    • (1986) Rev Modern Phys , vol.58 , Issue.1 , pp. 233
    • Brown, L.S.1    Gabrielse, G.2
  • 16
    • 50849142876 scopus 로고    scopus 로고
    • An electrically compensated trap designed to 8th order for FT-ICR mass spectrometry
    • Brustkern AM, Rempel DL, Gross ML,. 2008. An electrically compensated trap designed to 8th order for FT-ICR mass spectrometry. J Am Soc Mass Spectrom 19 (9): 1281-1285.
    • (2008) J Am Soc Mass Spectrom , vol.19 , Issue.9 , pp. 1281-1285
    • Brustkern, A.M.1    Rempel, D.L.2    Gross, M.L.3
  • 19
    • 84990661885 scopus 로고
    • Modelling coulomb effects in Fourier-transform ion cyclotron resonance mass spectrometry by charged disks and charged cylinders
    • Chen SP, Comisarow MB,. 1992. Modelling coulomb effects in Fourier-transform ion cyclotron resonance mass spectrometry by charged disks and charged cylinders. Rapid Commun Mass Spectrom 6 (1): 1-3.
    • (1992) Rapid Commun Mass Spectrom , vol.6 , Issue.1 , pp. 1-3
    • Chen, S.P.1    Comisarow, M.B.2
  • 20
    • 0000292366 scopus 로고
    • Fourier transform ion cyclotron resonance spectroscopy
    • Comisarow MB,. 1980. Fourier transform ion cyclotron resonance spectroscopy. Adv Mass Spectrom 8 (1698): 1706.
    • (1980) Adv Mass Spectrom , vol.8 , Issue.1698 , pp. 1706
    • Comisarow, M.B.1
  • 21
    • 0001557679 scopus 로고
    • Cubic trapped-ion cell for ion cyclotron resonance
    • Comisarow MB,. 1981. Cubic trapped-ion cell for ion cyclotron resonance. Int J Mass Spectrom Ion Phys 37 (2): 251-257.
    • (1981) Int J Mass Spectrom Ion Phys , vol.37 , Issue.2 , pp. 251-257
    • Comisarow, M.B.1
  • 22
    • 0001268221 scopus 로고
    • Fourier transform ion cyclotron resonance spectroscopy
    • Comisarow MB, Marshall AG,. 1974a. Fourier transform ion cyclotron resonance spectroscopy. Chem Phys Lett 25 (2): 282-283.
    • (1974) Chem Phys Lett , vol.25 , Issue.2 , pp. 282-283
    • Comisarow, M.B.1    Marshall, A.G.2
  • 23
    • 49549153202 scopus 로고
    • Frequency-sweep Fourier transform ion cyclotron resonance spectroscopy
    • Comisarow MB, Marshall AG,. 1974b. Frequency-sweep Fourier transform ion cyclotron resonance spectroscopy. Chem Phys Lett 26 (4): 489-490.
    • (1974) Chem Phys Lett , vol.26 , Issue.4 , pp. 489-490
    • Comisarow, M.B.1    Marshall, A.G.2
  • 24
    • 84968470212 scopus 로고
    • An algorithm for the machine calculation of complex Fourier series
    • Cooley JW, Tukey JW,. 1965. An algorithm for the machine calculation of complex Fourier series. Math Comput 19 (90): 297-301.
    • (1965) Math Comput , vol.19 , Issue.90 , pp. 297-301
    • Cooley, J.W.1    Tukey, J.W.2
  • 25
    • 0034716185 scopus 로고    scopus 로고
    • SIMION for the personal computer in reflection
    • Dahl DA,. 2000. SIMION for the personal computer in reflection. Int J Mass Spectrom 200 (1): 3-25.
    • (2000) Int J Mass Spectrom , vol.200 , Issue.1 , pp. 3-25
    • Dahl, D.A.1
  • 26
  • 27
    • 0033083537 scopus 로고    scopus 로고
    • Routine part-per-million mass accuracy for high-mass ions: Space-charge effects in MALDI FT-ICR
    • Easterling ML, Mize TH, Amster IJ,. 1999. Routine part-per-million mass accuracy for high-mass ions: Space-charge effects in MALDI FT-ICR. Anal Chem 71 (3): 624-632.
    • (1999) Anal Chem , vol.71 , Issue.3 , pp. 624-632
    • Easterling, M.L.1    Mize, T.H.2    Amster, I.J.3
  • 29
    • 0002688673 scopus 로고
    • Cylindrical Penning traps with orthogonalized anharmonicity compensation
    • Gabrielse G, MacKintosh FC,. 1984. Cylindrical Penning traps with orthogonalized anharmonicity compensation. Int J Mass Spectrom Ion Processes 57 (1): 1-17.
    • (1984) Int J Mass Spectrom Ion Processes , vol.57 , Issue.1 , pp. 1-17
    • Gabrielse, G.1    MacKintosh, F.C.2
  • 31
    • 30844449820 scopus 로고
    • Optimal cyclotron radius for high resolution FT-ICR spectrometry
    • Gorshkov MV, Nikolaev EN,. 1993. Optimal cyclotron radius for high resolution FT-ICR spectrometry. Int J Mass Spectrom Ion Processes 125 (1): 1-8.
    • (1993) Int J Mass Spectrom Ion Processes , vol.125 , Issue.1 , pp. 1-8
    • Gorshkov, M.V.1    Nikolaev, E.N.2
  • 32
    • 0008758173 scopus 로고
    • Cyclotron orbital radius determination in Fourier transform ion cyclotron resonance mass spectrometry
    • Grosshans PB, Marshall AG,. 1992. Cyclotron orbital radius determination in Fourier transform ion cyclotron resonance mass spectrometry. Int J Mass Spectrom Ion Processes 115 (1): 1-1-19.
    • (1992) Int J Mass Spectrom Ion Processes , vol.115 , Issue.1 , pp. 1-119
    • Grosshans, P.B.1    Marshall, A.G.2
  • 33
    • 0001196937 scopus 로고
    • Comprehensive theory of the Fourier transform ion cyclotron resonance signal for all ion trap geometries
    • Grosshans PB, Shields PJ, Marshall AG,. 1991. Comprehensive theory of the Fourier transform ion cyclotron resonance signal for all ion trap geometries. J Chem Phys 94: 5341.
    • (1991) J Chem Phys , vol.94 , pp. 5341
    • Grosshans, P.B.1    Shields, P.J.2    Marshall, A.G.3
  • 34
    • 0027600624 scopus 로고
    • Stored waveform inverse Fourier transform (SWIFT) axial excitation/ejection for quadrupole ion trap mass spectrometry
    • Guan S, Marshall AG,. Stored waveform inverse Fourier transform (SWIFT) axial excitation/ejection for quadrupole ion trap mass spectrometry. Anal Chem 1993. 65: 1288-1294.
    • (1993) Anal Chem , vol.65 , pp. 1288-1294
    • Guan, S.1    Marshall, A.G.2
  • 35
    • 58149209966 scopus 로고
    • Ion traps for Fourier transform ion cyclotron resonance mass spectrometry: Principles and design of geometric and electric configurations
    • Guan S, Marshall AG,. 1995. Ion traps for Fourier transform ion cyclotron resonance mass spectrometry: Principles and design of geometric and electric configurations. Int J Mass Spectrom Ion Processes 146: 261-296.
    • (1995) Int J Mass Spectrom Ion Processes , vol.146 , pp. 261-296
    • Guan, S.1    Marshall, A.G.2
  • 36
    • 0003115745 scopus 로고
    • Off-axis injection into an ICR ion trap: A means for efficient capture of a continuous beam of externally generated ions
    • Guan S, Paša-Tolic L, Marshall AG, Xiang X,. 1994a. Off-axis injection into an ICR ion trap: A means for efficient capture of a continuous beam of externally generated ions. Int J Mass Spectrom Ion Processes 139: 75-86.
    • (1994) Int J Mass Spectrom Ion Processes , vol.139 , pp. 75-86
    • Guan, S.1    Paša-Tolic, L.2    Marshall, A.G.3    Xiang, X.4
  • 37
    • 0000173772 scopus 로고
    • Xiang Xinzhen Shrink-wrapping an ion cloud for high-performance Fourier transform ion cyclotron resonance mass spectrometry
    • Guan S, Kim HS, Marshall AG, Wahl MC, Wood TD,. 1994b. Xiang Xinzhen Shrink-wrapping an ion cloud for high-performance Fourier transform ion cyclotron resonance mass spectrometry. Chem Rev 94 (8): 2161-2182.
    • (1994) Chem Rev , vol.94 , Issue.8 , pp. 2161-2182
    • Guan, S.1    Kim, H.S.2    Marshall, A.G.3    Wahl, M.C.4    Wood, T.D.5
  • 38
    • 0001666207 scopus 로고    scopus 로고
    • Effect of ion-neutral collision mechanism on the trapped-ion equation of motion: A new mass spectral line shape for high-mass trapped ions
    • Guan S, Li G-Z, Marshall AG,. 1997. Effect of ion-neutral collision mechanism on the trapped-ion equation of motion: A new mass spectral line shape for high-mass trapped ions. Int J Mass Spectrom Ion Processes 167-168: 185-193.
    • (1997) Int J Mass Spectrom Ion Processes , vol.167-168 , pp. 185-193
    • Guan, S.1    Li, G.-Z.2    Marshall, A.G.3
  • 39
    • 0008901390 scopus 로고
    • An ion trajectory model for Fourier transform ion cyclotron resonance mass spectrometry
    • Hearn BA, Watson CH, Baykut G, Eyler JR,. 1990. An ion trajectory model for Fourier transform ion cyclotron resonance mass spectrometry. Int J Mass Spectrom Ion processes 95 (3): 299-316.
    • (1990) Int J Mass Spectrom Ion Processes , vol.95 , Issue.3 , pp. 299-316
    • Hearn, B.A.1    Watson, C.H.2    Baykut, G.3    Eyler, J.R.4
  • 40
    • 0000181170 scopus 로고
    • Two-dimensional Coulomb-induced frequency modulation in Fourier transform ion cyclotron resonance: A mechanism for line broadening at high mass and for large ion populations
    • Hendrickson CL, Beu SC, Laude DA Jr., 1993. Two-dimensional Coulomb-induced frequency modulation in Fourier transform ion cyclotron resonance: A mechanism for line broadening at high mass and for large ion populations. J Am Soc Mass Spectrom 4 (12): 909-916.
    • (1993) J Am Soc Mass Spectrom , vol.4 , Issue.12 , pp. 909-916
    • Hendrickson, C.L.1    Beu, S.C.2    Laude, D.A.3
  • 41
    • 45149137811 scopus 로고
    • Limits to Fourier transform - Ion cyclotron resonance mass spectrometry for atomic mass measurements
    • Herold LK, Kouzes RT,. 1990. Limits to Fourier transform-Ion cyclotron resonance mass spectrometry for atomic mass measurements. Int J Mass Spectrom Ion Processes 96 (3): 247-289.
    • (1990) Int J Mass Spectrom Ion Processes , vol.96 , Issue.3 , pp. 247-289
    • Herold, L.K.1    Kouzes, R.T.2
  • 43
    • 0042174991 scopus 로고
    • Dynamics of ion coupling in an FTMS ion trap and resulting effects on mass spectra, including isotope ratios
    • Huang J, Tiedemann PW, Land DP, McIver RT, Hemminger JC,. 1994. Dynamics of ion coupling in an FTMS ion trap and resulting effects on mass spectra, including isotope ratios. Int J Mass Spectrom Ion Processes 134 (1): 11-21.
    • (1994) Int J Mass Spectrom Ion Processes , vol.134 , Issue.1 , pp. 11-21
    • Huang, J.1    Tiedemann, P.W.2    Land, D.P.3    McIver, R.T.4    Hemminger, J.C.5
  • 44
    • 0037103713 scopus 로고    scopus 로고
    • Resolution of 11 000 compositionally distinct components in a single electrospray ionization Fourier transform ion cyclotron resonance mass spectrum of crude oil
    • Hughey CA, Rodgers RP, Marshall AG,. 2002. Resolution of 11 000 compositionally distinct components in a single electrospray ionization Fourier transform ion cyclotron resonance mass spectrum of crude oil. Anal Chem 74 (16): 4145-4149.
    • (2002) Anal Chem , vol.74 , Issue.16 , pp. 4145-4149
    • Hughey, C.A.1    Rodgers, R.P.2    Marshall, A.G.3
  • 45
    • 0001912777 scopus 로고
    • Multiparticle simulation of ion motion in the ion trap mass spectrometer: Resonant and direct current pulse excitation
    • Julian RK, Nappi M, Weil C, Cooks RG,. 1995. Multiparticle simulation of ion motion in the ion trap mass spectrometer: Resonant and direct current pulse excitation. J Am Soc Mass Spectrom 6 (1): 57-70.
    • (1995) J Am Soc Mass Spectrom , vol.6 , Issue.1 , pp. 57-70
    • Julian, R.K.1    Nappi, M.2    Weil, C.3    Cooks, R.G.4
  • 46
    • 80052338649 scopus 로고    scopus 로고
    • Electrically compensated Fourier transform ion cyclotron resonance cell for complex mixture mass analysis
    • Kaiser NK, Savory JJ, McKenna AM, Quinn JP, Hendrickson CL, Marshall AG,. 2011. Electrically compensated Fourier transform ion cyclotron resonance cell for complex mixture mass analysis. Anal Chem 83 (17): 6907-6910.
    • (2011) Anal Chem , vol.83 , Issue.17 , pp. 6907-6910
    • Kaiser, N.K.1    Savory, J.J.2    McKenna, A.M.3    Quinn, J.P.4    Hendrickson, C.L.5    Marshall, A.G.6
  • 47
    • 84871727778 scopus 로고    scopus 로고
    • Tailored ion radius distribution for increased dynamic range in FT-ICR mass analysis of complex mixtures
    • Kaiser NK, McKenna AM, Savory JJ, Hendrickson CL, Marshall AG,. 2012. Tailored ion radius distribution for increased dynamic range in FT-ICR mass analysis of complex mixtures. Anal Chem 85 (1): 265-272.
    • (2012) Anal Chem , vol.85 , Issue.1 , pp. 265-272
    • Kaiser, N.K.1    McKenna, A.M.2    Savory, J.J.3    Hendrickson, C.L.4    Marshall, A.G.5
  • 48
    • 84862556418 scopus 로고    scopus 로고
    • Performance of Orbitrap mass analyzer at various space charge and non-ideal field conditions: Simulation approach
    • Kharchenko A, Vladimirov G, Heeren RM, Nikolaev EN,. 2012. Performance of Orbitrap mass analyzer at various space charge and non-ideal field conditions: Simulation approach. J Am Soc Mass Spectrom 23 (5): 977-987.
    • (2012) J Am Soc Mass Spectrom , vol.23 , Issue.5 , pp. 977-987
    • Kharchenko, A.1    Vladimirov, G.2    Heeren, R.M.3    Nikolaev, E.N.4
  • 49
    • 0142104156 scopus 로고    scopus 로고
    • Graphical method for analysis of ultrahigh-resolution broadband mass spectra of natural organic matter, the van Krevelen diagram
    • Kim S, Kramer RW, Hatcher PG,. 2003. Graphical method for analysis of ultrahigh-resolution broadband mass spectra of natural organic matter, the van Krevelen diagram. Anal Chem 75 (20): 5336-5344.
    • (2003) Anal Chem , vol.75 , Issue.20 , pp. 5336-5344
    • Kim, S.1    Kramer, R.W.2    Hatcher, P.G.3
  • 50
    • 43949162266 scopus 로고
    • Suppression, amplification and application of the third harmonic of the cyclotron frequency in ion cyclotron resonance spectrometry
    • Knobeler M, Wanczek KP,. 1993. Suppression, amplification and application of the third harmonic of the cyclotron frequency in ion cyclotron resonance spectrometry. Int J Mass Spectrom Ion Processes 125 (2): 127-134.
    • (1993) Int J Mass Spectrom Ion Processes , vol.125 , Issue.2 , pp. 127-134
    • Knobeler, M.1    Wanczek, K.P.2
  • 52
    • 84878647630 scopus 로고    scopus 로고
    • Simple atmospheric hydrogen/deuterium exchange method for enumeration of labile hydrogens by electrospray ionization mass spectrometry
    • Kostyukevich Y, Kononikhin A, Popov I, Nikolaev E,. 2013a. Simple atmospheric hydrogen/deuterium exchange method for enumeration of labile hydrogens by electrospray ionization mass spectrometry. Anal Chem 85 (11): 5330-5334.
    • (2013) Anal Chem , vol.85 , Issue.11 , pp. 5330-5334
    • Kostyukevich, Y.1    Kononikhin, A.2    Popov, I.3    Nikolaev, E.4
  • 53
    • 84888388585 scopus 로고    scopus 로고
    • Enumeration of labile hydrogens in natural organic matter by use of hydrogen/deuterium exchange Fourier transform ion cyclotron resonance mass spectrometry
    • Kostyukevich Y, Kononikhin A, Popov I, Kharybin O, Perminova I, Konstantinov A, Nikolaev E,. 2013b. Enumeration of labile hydrogens in natural organic matter by use of hydrogen/deuterium exchange Fourier transform ion cyclotron resonance mass spectrometry. Anal Chem 85 (22): 11007-11013.
    • (2013) Anal Chem , vol.85 , Issue.22 , pp. 11007-11013
    • Kostyukevich, Y.1    Kononikhin, A.2    Popov, I.3    Kharybin, O.4    Perminova, I.5    Konstantinov, A.6    Nikolaev, E.7
  • 55
    • 0348017701 scopus 로고
    • The effects of residual spatial magnetic field gradients on Fourier transform ion cyclotron resonance spectra
    • Laukien FH,. 1986. The effects of residual spatial magnetic field gradients on Fourier transform ion cyclotron resonance spectra. Int J Mass Spectrom Ion Processes 73 (1): 81-107.
    • (1986) Int J Mass Spectrom Ion Processes , vol.73 , Issue.1 , pp. 81-107
    • Laukien, F.H.1
  • 56
    • 74249089408 scopus 로고    scopus 로고
    • Comparison of particle-in-cell simulations with experimentally observed frequency shifts between ions of the same mass-to-charge in Fourier transform ion cyclotron resonance mass spectrometry
    • Leach, FE III, Kharchenko A, Heeren R, Nikolaev E, Amster IJ,. 2010. Comparison of particle-in-cell simulations with experimentally observed frequency shifts between ions of the same mass-to-charge in Fourier transform ion cyclotron resonance mass spectrometry. J Am Soc Mass Spectrom 21 (2): 203-208.
    • (2010) J Am Soc Mass Spectrom , vol.21 , Issue.2 , pp. 203-208
    • Leach, F.E.1    Kharchenko, A.2    Heeren, R.3    Nikolaev, E.4    Amster, I.J.5
  • 58
    • 0021705942 scopus 로고
    • Space charge effects in Fourier transform mass spectrometry. II. Mass calibration
    • Ledford EB Jr, Rempel DL, Gross ML,. 1984. Space charge effects in Fourier transform mass spectrometry. II. Mass calibration. Anal Chem 56 (14): 2744-2748.
    • (1984) Anal Chem , vol.56 , Issue.14 , pp. 2744-2748
    • Ledford, E.B.1    Rempel, D.L.2    Gross, M.L.3
  • 59
    • 84912777501 scopus 로고
    • Measurement of the mass difference between tritium and helium-3 ions by a high-resolution ion-cyclotron-resonance method
    • Lippmaa ET, Pikver FT, Suurmaa ER, Past YO, Puskar YK, Koppel IA, Tammik AA,. 1984. Measurement of the mass difference between tritium and helium-3 ions by a high-resolution ion-cyclotron-resonance method. JETP Lett 39 (11): 646-648.
    • (1984) JETP Lett , vol.39 , Issue.11 , pp. 646-648
    • Lippmaa, E.T.1    Pikver, F.T.2    Suurmaa, E.R.3    Past, Y.O.4    Puskar, Y.K.5    Koppel, I.A.6    Tammik, A.A.7
  • 60
    • 0000328369 scopus 로고
    • Computer simulation of single-ion trajectories in Paul-type ion traps
    • Londry FA, Alfred RL, March RE,. 1993. Computer simulation of single-ion trajectories in Paul-type ion traps. J Am Soc Mass Spectrom 4 (9): 687-705.
    • (1993) J Am Soc Mass Spectrom , vol.4 , Issue.9 , pp. 687-705
    • Londry, F.A.1    Alfred, R.L.2    March, R.E.3
  • 62
    • 0001330120 scopus 로고    scopus 로고
    • Harmonic inversion of time signals its applications
    • Mandelshtam VA, Taylor HS,. Harmonic inversion of time signals its applications, J Chem Phys 1997. 107: 6756-6769.
    • (1997) J Chem Phys , vol.107 , pp. 6756-6769
    • Mandelshtam, V.A.1    Taylor, H.S.2
  • 63
    • 0000143445 scopus 로고
    • Fourier transform ion cyclotron resonance mass spectrometry: The teenage years
    • Marshal AG, Grosshans PB,. 1991. Fourier transform ion cyclotron resonance mass spectrometry: The teenage years. Anal Chem 63 (4): 215A-229A.
    • (1991) Anal Chem , vol.63 , Issue.4 , pp. 215A-229A
    • Marshal, A.G.1    Grosshans, P.B.2
  • 64
    • 0030468505 scopus 로고    scopus 로고
    • Advantages of high magnetic field for Fourier transform ion cyclotron resonance mass spectrometry
    • Marshall AG, Guan S,. 1996. Advantages of high magnetic field for Fourier transform ion cyclotron resonance mass spectrometry. Rapid Commun Mass Spectrom 10 (14): 1819-1823.
    • (1996) Rapid Commun Mass Spectrom , vol.10 , Issue.14 , pp. 1819-1823
    • Marshall, A.G.1    Guan, S.2
  • 66
    • 0031623267 scopus 로고    scopus 로고
    • Fourier transform ion cyclotron resonance mass spectrometry: A primer
    • Marshall AG, Hendrickson CL, Jackson GS,. 1998. Fourier transform ion cyclotron resonance mass spectrometry: A primer. Mass Spectrom Rev 17 (1): 1-35.
    • (1998) Mass Spectrom Rev , vol.17 , Issue.1 , pp. 1-35
    • Marshall, A.G.1    Hendrickson, C.L.2    Jackson, G.S.3
  • 68
    • 36449006911 scopus 로고
    • Wall and Daniel Neuhauser Extraction, through filter diagonalization, of general quantum eigenvalues or classical normal mode frequencies from a small number of residues or a short time segment of a signal. I. Theory and application to a quantum dynamics model
    • Michael R,. 1995. Wall and Daniel Neuhauser Extraction, through filter diagonalization, of general quantum eigenvalues or classical normal mode frequencies from a small number of residues or a short time segment of a signal. I. Theory and application to a quantum dynamics model J Chem Phys 102: 8011.
    • (1995) J Chem Phys , vol.102 , pp. 8011
    • Michael, R.1
  • 69
    • 84865450970 scopus 로고    scopus 로고
    • Tsybin Yury O sidebands in Fourier transform ion cyclotron resonance mass spectra
    • Miladinovica SM, Kozhinov AN, Tsybinb OY,. 2012. Tsybin Yury O sidebands in Fourier transform ion cyclotron resonance mass spectra. Int J Mass Spectrom 325-327: 10-18.
    • (2012) Int J Mass Spectrom , vol.325-327 , pp. 10-18
    • Miladinovica, S.M.1    Kozhinov, A.N.2    Tsybinb, O.Y.3
  • 70
    • 84990636402 scopus 로고
    • Application of a parallel computer to simulation of ion trajectories in an ion cyclotron resonance spectrometer
    • Miluchihin NV, Miura K, Inoue M,. 1993. Application of a parallel computer to simulation of ion trajectories in an ion cyclotron resonance spectrometer. Rapid Commun Mass Spectrom 7 (11): 966-970.
    • (1993) Rapid Commun Mass Spectrom , vol.7 , Issue.11 , pp. 966-970
    • Miluchihin, N.V.1    Miura, K.2    Inoue, M.3
  • 71
    • 0033392170 scopus 로고    scopus 로고
    • Realistic simulation of the ion cyclotron resonance mass spectrometer using a distributed three-dimensional particle-in-cell code
    • Mitchell DW,. 1999. Realistic simulation of the ion cyclotron resonance mass spectrometer using a distributed three-dimensional particle-in-cell code. J Am Soc Mass Spectrom 10 (2): 136-152.
    • (1999) J Am Soc Mass Spectrom , vol.10 , Issue.2 , pp. 136-152
    • Mitchell, D.W.1
  • 72
    • 0001365594 scopus 로고
    • Cyclotron motion of two Coulombically interacting ion clouds with implications to Fourier-transform ion cyclotron resonance mass spectrometry
    • Mitchell DW, Smith RD,. 1995. Cyclotron motion of two Coulombically interacting ion clouds with implications to Fourier-transform ion cyclotron resonance mass spectrometry. Phys Rev E 52 (4): 4366.
    • (1995) Phys Rev e , vol.52 , Issue.4 , pp. 4366
    • Mitchell, D.W.1    Smith, R.D.2
  • 73
    • 0029679968 scopus 로고    scopus 로고
    • Prediction of a space charge induced upper molecular mass limit towards achieving unit mass resolution in Fourier transform ion cyclotron resonance mass spectrometry
    • Mitchell DW, Smith RD,. 1996. Prediction of a space charge induced upper molecular mass limit towards achieving unit mass resolution in Fourier transform ion cyclotron resonance mass spectrometry. J Mass Spectrom 31 (7): 771-790.
    • (1996) J Mass Spectrom , vol.31 , Issue.7 , pp. 771-790
    • Mitchell, D.W.1    Smith, R.D.2
  • 74
    • 4243358034 scopus 로고    scopus 로고
    • Two dimensional many particle simulation of trapped ions
    • Mitchell DW, Smith RD,. 1997. Two dimensional many particle simulation of trapped ions. Int J Mass Spectrom Ion Processes 165: 271-297.
    • (1997) Int J Mass Spectrom Ion Processes , vol.165 , pp. 271-297
    • Mitchell, D.W.1    Smith, R.D.2
  • 75
    • 0003375301 scopus 로고
    • Peak confluence phenomenon in Fourier transform ion cyclotron resonance mass spectrometry
    • Naito Y, Inoue M,. 1994. Peak confluence phenomenon in Fourier transform ion cyclotron resonance mass spectrometry. J Mass Spectrom Soc Jpn 42 (1): 1-9.
    • (1994) J Mass Spectrom Soc Jpn , vol.42 , Issue.1 , pp. 1-9
    • Naito, Y.1    Inoue, M.2
  • 76
    • 0030850070 scopus 로고    scopus 로고
    • Non-linear effects on Fourier transform ion cyclotron resonance mass spectra induced by off-resonance excitations
    • Naito Y, Inoue M,. 1997. Non-linear effects on Fourier transform ion cyclotron resonance mass spectra induced by off-resonance excitations. Rapid Commun Mass Spectrom 11 (6): 578-586.
    • (1997) Rapid Commun Mass Spectrom , vol.11 , Issue.6 , pp. 578-586
    • Naito, Y.1    Inoue, M.2
  • 77
    • 26644461986 scopus 로고
    • Ion cyclotron resonance measurement of the mass difference between tritium and helium-3
    • Nikolaev EN, Neronov YI, Gorshkov MV, Tal'Roze VL,. 1984. Ion cyclotron resonance measurement of the mass difference between tritium and helium-3. JETP Lett 39 (9): 534-536.
    • (1984) JETP Lett , vol.39 , Issue.9 , pp. 534-536
    • Nikolaev, E.N.1    Neronov, Y.I.2    Gorshkov, M.V.3    Tal'Roze, V.L.4
  • 78
    • 0001200142 scopus 로고
    • Evolution of an ion cloud in a Fourier transform ion cyclotron resonance mass spectrometer during signal detection: Its influence on spectral line shape and position
    • Nikolaev EN, Miluchihin NV, Inoue M,. 1995. Evolution of an ion cloud in a Fourier transform ion cyclotron resonance mass spectrometer during signal detection: Its influence on spectral line shape and position. Int J Mass Spectrom Ion Processes 148 (3): 145-157.
    • (1995) Int J Mass Spectrom Ion Processes , vol.148 , Issue.3 , pp. 145-157
    • Nikolaev, E.N.1    Miluchihin, N.V.2    Inoue, M.3
  • 79
    • 36249009481 scopus 로고    scopus 로고
    • Realistic modeling of ion cloud motion in a Fourier transform ion cyclotron resonance cell by use of a particle-in-cell approach
    • Nikolaev EN, Heeren R, Popov AM, Pozdneev AV, Chingin KS,. 2007. Realistic modeling of ion cloud motion in a Fourier transform ion cyclotron resonance cell by use of a particle-in-cell approach. Rapid Commun Mass Spectrom 21 (22): 3527-3546.
    • (2007) Rapid Commun Mass Spectrom , vol.21 , Issue.22 , pp. 3527-3546
    • Nikolaev, E.N.1    Heeren, R.2    Popov, A.M.3    Pozdneev, A.V.4    Chingin, K.S.5
  • 80
    • 79959999382 scopus 로고    scopus 로고
    • Initial experimental characterization of a new ultra-high resolution FTICR cell with dynamic harmonization
    • Nikolaev EN, Boldin IA, Jertz R, Baykut G,. 2011. Initial experimental characterization of a new ultra-high resolution FTICR cell with dynamic harmonization. J Am Soc Mass Spectrom 22 (7): 1125-1133.
    • (2011) J Am Soc Mass Spectrom , vol.22 , Issue.7 , pp. 1125-1133
    • Nikolaev, E.N.1    Boldin, I.A.2    Jertz, R.3    Baykut, G.4
  • 81
    • 84857831190 scopus 로고    scopus 로고
    • Fine structure in isotopic peak distributions measured using a dynamically harmonized Fourier transform ion cyclotron resonance cell at 7 T
    • Nikolaev EN, Jertz R, Grigoryev A, Baykut G,. 2012. Fine structure in isotopic peak distributions measured using a dynamically harmonized Fourier transform ion cyclotron resonance cell at 7 T. Anal Chem 84 (5): 2275-2283.
    • (2012) Anal Chem , vol.84 , Issue.5 , pp. 2275-2283
    • Nikolaev, E.N.1    Jertz, R.2    Grigoryev, A.3    Baykut, G.4
  • 83
    • 84899559917 scopus 로고    scopus 로고
    • From supercomputer modeling to highest mass resolution in FT-ICR
    • Nikolaev EN, Vladimirov GN, Jertz R, Baykut G,. 2013a. From supercomputer modeling to highest mass resolution in FT-ICR. Mass Spectrom 2: S0010.
    • (2013) Mass Spectrom , vol.2 , pp. S0010
    • Nikolaev, E.N.1    Vladimirov, G.N.2    Jertz, R.3    Baykut, G.4
  • 85
    • 0008743904 scopus 로고
    • Plasmas with a single sign of charge (an overview)
    • O'Neil TM,. 1995. Plasmas with a single sign of charge (an overview). Phys Scrip 1995 (T59): 341.
    • (1995) Phys Scrip , vol.1995 T59 , pp. 341
    • O'Neil, T.M.1
  • 86
    • 0029062588 scopus 로고
    • Ultrahigh-resolution matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectra of peptides
    • Paša-Tolic L, Huang Y, Guan S, Kim HS, Marshall AG,. 1995. Ultrahigh-resolution matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectra of peptides. J Mass Spectrom 30 (6): 825-833.
    • (1995) J Mass Spectrom , vol.30 , Issue.6 , pp. 825-833
    • Paša-Tolic, L.1    Huang, Y.2    Guan, S.3    Kim, H.S.4    Marshall, A.G.5
  • 87
    • 0000294342 scopus 로고
    • Long-term coherence of the cyclotron mode in a trapped ion cloud
    • Peurrung AJ, Kouzes RT,. 1994. Long-term coherence of the cyclotron mode in a trapped ion cloud. Phys Rev E 49 (5): 4362.
    • (1994) Phys Rev e , vol.49 , Issue.5 , pp. 4362
    • Peurrung, A.J.1    Kouzes, R.T.2
  • 88
    • 0000153240 scopus 로고
    • Analysis of space-charge effects in cyclotron resonance mass spectrometry as coupled gyrator phenomena
    • Peurrung AJ, Kouzes RT,. 1995. Analysis of space-charge effects in cyclotron resonance mass spectrometry as coupled gyrator phenomena. Int J Mass Spectrom Ion Processes 145 (3): 139-153.
    • (1995) Int J Mass Spectrom Ion Processes , vol.145 , Issue.3 , pp. 139-153
    • Peurrung, A.J.1    Kouzes, R.T.2
  • 89
    • 33845278744 scopus 로고
    • Broad-band two-dimensional Fourier transform ion cyclotron resonance
    • Pfaendler P, Bodenhausen G, Rapin J, Walser ME, Gaeumann T,. 1988. Broad-band two-dimensional Fourier transform ion cyclotron resonance. J Am Chem Soc 110 (17): 5625-5628.
    • (1988) J Am Chem Soc , vol.110 , Issue.17 , pp. 5625-5628
    • Pfaendler, P.1    Bodenhausen, G.2    Rapin, J.3    Walser, M.E.4    Gaeumann, T.5
  • 90
    • 0001249667 scopus 로고
    • Discrete Fourier transforms when the number of data samples is prime
    • Rader CM,. 1968. Discrete Fourier transforms when the number of data samples is prime, Proc IEEE 56: 1107-1108.
    • (1968) Proc IEEE , vol.56 , pp. 1107-1108
    • Rader, C.M.1
  • 91
    • 0038236968 scopus 로고    scopus 로고
    • Two ions in one trap: Ultra-high precision mass spectrometry
    • Rainville S, Thompson JK, Pritchard DE,. 2003. Two ions in one trap: Ultra-high precision mass spectrometry ? IEEE Trans Instrum Meas 52 (2): 292-296.
    • (2003) IEEE Trans Instrum Meas , vol.52 , Issue.2 , pp. 292-296
    • Rainville, S.1    Thompson, J.K.2    Pritchard, D.E.3
  • 92
    • 44949150382 scopus 로고    scopus 로고
    • High-performance mass spectrometry: Fourier transform ion cyclotron resonance at 14.5 Tesla
    • Schaub TM, Hendrickson CL, Horning S, Quinn JP, Senko MW, Marshall AG,. 2008. High-performance mass spectrometry: Fourier transform ion cyclotron resonance at 14.5 Tesla. Anal Chem 80 (11): 3985-3990.
    • (2008) Anal Chem , vol.80 , Issue.11 , pp. 3985-3990
    • Schaub, T.M.1    Hendrickson, C.L.2    Horning, S.3    Quinn, J.P.4    Senko, M.W.5    Marshall, A.G.6
  • 93
    • 0033452574 scopus 로고    scopus 로고
    • Fourier transform ion cyclotron resonance mass spectrometry in a high homogeneity 25 Tesla resistive magnet
    • Shi SDH, Drader JJ, Hendrickson CL, Marshall AG,. 1999. Fourier transform ion cyclotron resonance mass spectrometry in a high homogeneity 25 Tesla resistive magnet. J Am Soc Mass Spectrom 10 (3): 265-268.
    • (1999) J Am Soc Mass Spectrom , vol.10 , Issue.3 , pp. 265-268
    • Shi, S.D.H.1    Drader, J.J.2    Hendrickson, C.L.3    Marshall, A.G.4
  • 94
    • 84957455800 scopus 로고    scopus 로고
    • SIMION. Supplemental Documentation
    • SIMION. Supplemental Documentation. http://simion.com/info/.
  • 95
    • 0028225529 scopus 로고
    • Trapping, detection and reaction of very large single molecular ions by mass spectrometry
    • Smith RD, Cheng X, Brace JE, Hofstadler SA, Anderson GA,. 1994. Trapping, detection and reaction of very large single molecular ions by mass spectrometry. Nature 369 (6476): 137-139.
    • (1994) Nature , vol.369 , Issue.6476 , pp. 137-139
    • Smith, R.D.1    Cheng, X.2    Brace, J.E.3    Hofstadler, S.A.4    Anderson, G.A.5
  • 96
    • 36149016028 scopus 로고
    • The measurement of e/m by cyclotron resonance
    • Sommer H, Thomas HA, Hipple JA,. 1951. The measurement of e/m by cyclotron resonance. Phys Rev 82 (5): 697.
    • (1951) Phys Rev , vol.82 , Issue.5 , pp. 697
    • Sommer, H.1    Thomas, H.A.2    Hipple, J.A.3
  • 98
    • 0001106904 scopus 로고    scopus 로고
    • Minimizing peak coalescence: High-resolution separation of isotope peaks in partially deamidated peptides by matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry
    • Stults JT,. 1997. Minimizing peak coalescence: High-resolution separation of isotope peaks in partially deamidated peptides by matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry. Anal Chem 69 (10): 1815-1819.
    • (1997) Anal Chem , vol.69 , Issue.10 , pp. 1815-1819
    • Stults, J.T.1
  • 99
    • 79958195509 scopus 로고    scopus 로고
    • TOF systems with two-directional isochronous motion
    • Sudakov M, Kumashiro S,. 2011. TOF systems with two-directional isochronous motion. Nucl Instrum Methods Phys Res Sect A 645 (1): 210-215.
    • (2011) Nucl Instrum Methods Phys Res Sect A , vol.645 , Issue.1 , pp. 210-215
    • Sudakov, M.1    Kumashiro, S.2
  • 101
    • 0000536312 scopus 로고
    • Space charge effects on relative peak heights in fourier transform-ion cyclotron resonance spectra
    • Uechi GT, Dunbar RC,. 1992. Space charge effects on relative peak heights in fourier transform-ion cyclotron resonance spectra. J Am Soc Mass Spectrom 3 (7): 734-741.
    • (1992) J Am Soc Mass Spectrom , vol.3 , Issue.7 , pp. 734-741
    • Uechi, G.T.1    Dunbar, R.C.2
  • 102
    • 33744568742 scopus 로고
    • Electron magnetic moment from geonium spectra: Early experiments and background concepts
    • Van Dyck RS Jr, Schwinberg PB, Dehmelt HG,. 1986. Electron magnetic moment from geonium spectra: Early experiments and background concepts. Phys Rev D 34 (3): 722.
    • (1986) Phys Rev D , vol.34 , Issue.3 , pp. 722
    • Van Dyck, R.S.1    Schwinberg, P.B.2    Dehmelt, H.G.3
  • 105
    • 84856283788 scopus 로고    scopus 로고
    • Fourier transform ion cyclotron resonance mass resolution and dynamic range limits calculated by computer modeling of ion cloud motion
    • Vladimirov G, Hendrickson CL, Blakney GT, Marshall AG, Heeren RM, Nikolaev EN,. 2012. Fourier transform ion cyclotron resonance mass resolution and dynamic range limits calculated by computer modeling of ion cloud motion. J Am Soc Mass Spectrom 23 (2): 375-384.
    • (2012) J Am Soc Mass Spectrom , vol.23 , Issue.2 , pp. 375-384
    • Vladimirov, G.1    Hendrickson, C.L.2    Blakney, G.T.3    Marshall, A.G.4    Heeren, R.M.5    Nikolaev, E.N.6
  • 106
    • 0003869496 scopus 로고
    • Ion cyclotron resonance spectrometry - A review
    • Wanczek KP,. 1984. Ion cyclotron resonance spectrometry-A review. Int J Mass Spectrom Ion Processes 60 (1): 11-60.
    • (1984) Int J Mass Spectrom Ion Processes , vol.60 , Issue.1 , pp. 11-60
    • Wanczek, K.P.1
  • 107
    • 0002325174 scopus 로고
    • ICR spectrometry - A review of new developments in theory, instrumentation, and applications. I. 1983-1986
    • Wanczek KP,. 1989. ICR spectrometry-A review of new developments in theory, instrumentation, and applications. I. 1983-1986. Int J Mass Spectrom Ion Processes 95 (1): 1-38.
    • (1989) Int J Mass Spectrom Ion Processes , vol.95 , Issue.1 , pp. 1-38
    • Wanczek, K.P.1
  • 108
    • 0000331290 scopus 로고
    • Coulomb broadening in Fourier transform ion cyclotron resonance mass spectrometry
    • Wang TC, Marshall AG,. 1986. Coulomb broadening in Fourier transform ion cyclotron resonance mass spectrometry. Int J Mass Spectrom Ion Processes 68 (3): 287-301.
    • (1986) Int J Mass Spectrom Ion Processes , vol.68 , Issue.3 , pp. 287-301
    • Wang, T.C.1    Marshall, A.G.2
  • 109
    • 0022990528 scopus 로고
    • Extension of dynamic range in Fourier transform ion cyclotron resonance mass spectrometry via stored waveform inverse Fourier transform excitation
    • Wang TCL, Ricca TL, Marshall AG,. 1986. Extension of dynamic range in Fourier transform ion cyclotron resonance mass spectrometry via stored waveform inverse Fourier transform excitation. Anal Chem 58 (14): 2935-2938.
    • (1986) Anal Chem , vol.58 , Issue.14 , pp. 2935-2938
    • Wang, T.C.L.1    Ricca, T.L.2    Marshall, A.G.3
  • 111
    • 0000497952 scopus 로고
    • Ion cyclotron resonance spectrometer
    • Wobschall D,. 1965. Ion cyclotron resonance spectrometer. Rev Sci Instrum 36 (4): 466-475.
    • (1965) Rev Sci Instrum , vol.36 , Issue.4 , pp. 466-475
    • Wobschall, D.1
  • 112
    • 0000528174 scopus 로고
    • Ion cyclotron resonance and the determination of collision cross sections
    • Wobschall D, Graham JR Jr, Malone DP,. 1963. Ion cyclotron resonance and the determination of collision cross sections. Phys Rev 131 (4): 1565.
    • (1963) Phys Rev , vol.131 , Issue.4 , pp. 1565
    • Wobschall, D.1    Graham, J.R.2    Malone, D.P.3
  • 113
    • 33745641097 scopus 로고    scopus 로고
    • Ion trajectory simulations of axial ac dipolar excitation in the Orbitrap
    • Wu G, Noll RJ, Plass WR, Hu Q, Perry RH, Cooks RG,. 2006. Ion trajectory simulations of axial ac dipolar excitation in the Orbitrap. Int J Mass Spectrom 254 (1): 53-62.
    • (2006) Int J Mass Spectrom , vol.254 , Issue.1 , pp. 53-62
    • Wu, G.1    Noll, R.J.2    Plass, W.R.3    Hu, Q.4    Perry, R.H.5    Cooks, R.G.6
  • 114
    • 0000607392 scopus 로고
    • Simulated ion trajectory and induced signal in ion cyclotron resonance ion traps. Effect of ion initial axial position on ion coherence, induced signal, and radial or z ejection in a cubic trap
    • Xiang X, Marshall AG,. 1994. Simulated ion trajectory and induced signal in ion cyclotron resonance ion traps. effect of ion initial axial position on ion coherence, induced signal, and radial or z ejection in a cubic trap. J Am Soc Mass Spectrom 5 (9): 807-813.
    • (1994) J Am Soc Mass Spectrom , vol.5 , Issue.9 , pp. 807-813
    • Xiang, X.1    Marshall, A.G.2
  • 115
    • 0008908949 scopus 로고
    • Simulated ion trajectory and induced signal in ion cyclotron resonance ion traps
    • Xiang X, Guan S, Marshall AG,. 1994. Simulated ion trajectory and induced signal in ion cyclotron resonance ion traps. J Am Soc Mass Spectrom 5 (4): 238-249.
    • (1994) J Am Soc Mass Spectrom , vol.5 , Issue.4 , pp. 238-249
    • Xiang, X.1    Guan, S.2    Marshall, A.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.