메뉴 건너뛰기




Volumn 23, Issue 12, 2012, Pages 2198-2207

Dynamically harmonized FT-ICR cell with specially shaped electrodes for compensation of inhomogeneity of the magnetic field. Computer simulations of the electric field and ion motion dynamics

Author keywords

FT ICR; FTMS; Simulation

Indexed keywords

CYCLOTRON FREQUENCY; FT-ICR; FT-ICR MASS SPECTROMETRY; FTMS; INHOMOGENEOUS MAGNETIC FIELD; ION-CYCLOTRON FREQUENCY; MAGNETIC FIELD INHOMOGENEITIES; SIMULATION;

EID: 84873969859     PISSN: 10440305     EISSN: 18791123     Source Type: Journal    
DOI: 10.1007/s13361-012-0480-1     Document Type: Article
Times cited : (46)

References (25)
  • 1
    • 80052338649 scopus 로고    scopus 로고
    • Electrically compensated Fourier transform ion cyclotron resonance cell for complex mixture mass analysis
    • 10.1021/ac201546d 1:CAS:528:DC%2BC3MXhtVWhu7zI
    • Kaiser, N.K., Savory, J.J., McKenna, A.M., Quinn, J.P., Hendrickson, C.L., Marshall, A.G.: Electrically compensated Fourier transform ion cyclotron resonance cell for complex mixture mass analysis. Anal. Chem. 83(17), 6907-6910 (2011)
    • (2011) Anal. Chem. , vol.83 , Issue.17 , pp. 6907-6910
    • Kaiser, N.K.1    Savory, J.J.2    McKenna, A.M.3    Quinn, J.P.4    Hendrickson, C.L.5    Marshall, A.G.6
  • 2
    • 0031623267 scopus 로고    scopus 로고
    • Fourier transform ion cyclotron resonance mass spectrometry: A primer
    • 10.1002/(SICI)1098-2787(1998)17:1<1: AID-MAS1>3.0.CO;2-K 1:CAS:528:DyaK1cXmsFantbk%3D
    • Marshall, A.G., Hendrickson, C.L., Jackson, G.S.: Fourier transform ion cyclotron resonance mass spectrometry: a primer. Mass Spectrom Rev. 17(1), 1-35 (1998)
    • (1998) Mass Spectrom Rev. , vol.17 , Issue.1 , pp. 1-35
    • Marshall, A.G.1    Hendrickson, C.L.2    Jackson, G.S.3
  • 3
    • 14744304574 scopus 로고    scopus 로고
    • Proteomics by FTICR mass spectrometry: Top down and bottom up
    • 10.1002/mas.20015 1:CAS:528:DC%2BD2MXit1Wgtrk%3D
    • Bogdanov, B., Smith, R.D.: Proteomics by FTICR mass spectrometry: top down and bottom up. Mass Spectrom. Rev. 24(2), 168-200 (2005)
    • (2005) Mass Spectrom. Rev. , vol.24 , Issue.2 , pp. 168-200
    • Bogdanov, B.1    Smith, R.D.2
  • 4
    • 1642494964 scopus 로고    scopus 로고
    • Petroleomics: The next grand challenge for chemical analysis
    • 10.1021/ar020177t 1:CAS:528:DC%2BD3sXpsFaqs7Y%3D
    • Marshall, A.G., Rodgers, R.P.: Petroleomics: the next grand challenge for chemical analysis. Acc. Chem. Res. 37(1), 53-59 (2004)
    • (2004) Acc. Chem. Res. , vol.37 , Issue.1 , pp. 53-59
    • Marshall, A.G.1    Rodgers, R.P.2
  • 5
    • 0142104156 scopus 로고    scopus 로고
    • Graphical method for analysis of ultrahigh-resolution broadband mass spectra of natural organic matter, the Van Krevelen diagram
    • 10.1021/ac034415p 1:CAS:528:DC%2BD3sXnt1OhsrY%3D
    • Kim, S., Kramer, R.W., Hatcher, P.G.: Graphical method for analysis of ultrahigh-resolution broadband mass spectra of natural organic matter, the Van Krevelen diagram. Anal. Chem. 75, 5336-5344 (2003)
    • (2003) Anal. Chem. , vol.75 , pp. 5336-5344
    • Kim, S.1    Kramer, R.W.2    Hatcher, P.G.3
  • 6
    • 84857831190 scopus 로고    scopus 로고
    • Fine structure in isotopic peak distributions measured using a dynamically harmonized Fourier transform ion cyclotron resonance cell at 7 T
    • 10.1021/ac202804f 1:CAS:528:DC%2BC38XhsVyqu7g%3D
    • Nikolaev, E.N., Jertz, R., Grigoryev, A., Baykut, G.: Fine structure in isotopic peak distributions measured using a dynamically harmonized Fourier transform ion cyclotron resonance cell at 7 T. Anal. Chem. 84(5), 2275-2283 (2012)
    • (2012) Anal. Chem. , vol.84 , Issue.5 , pp. 2275-2283
    • Nikolaev, E.N.1    Jertz, R.2    Grigoryev, A.3    Baykut, G.4
  • 7
    • 0000440188 scopus 로고
    • Open-endcap Penning traps for high precision experiments
    • 10.1016/0168-1176(89)85027-X 1:CAS:528:DyaL1MXkvVGntrc%3D
    • Gabrielse, G., Haarsma, L., Rolston, S.L.: Open-endcap Penning traps for high precision experiments. Int. J. Mass Spectrom. Ion Processes 88, 319-332 (1989)
    • (1989) Int. J. Mass Spectrom. Ion Processes , vol.88 , pp. 319-332
    • Gabrielse, G.1    Haarsma, L.2    Rolston, S.L.3
  • 8
    • 50849142876 scopus 로고    scopus 로고
    • An electrically compensated trap designed to eighth order for FT-ICR mass spectrometry
    • 10.1016/j.jasms.2008.05.016 1:CAS:528:DC%2BD1cXhtVyisb7K
    • Brustkern, A.M., Rempel, D.L., Gross, M.L.: An electrically compensated trap designed to eighth order for FT-ICR mass spectrometry. J. Am. Soc Mass Spectrom 19(9), 1281-1285 (2008)
    • (2008) J. Am. Soc Mass Spectrom , vol.19 , Issue.9 , pp. 1281-1285
    • Brustkern, A.M.1    Rempel, D.L.2    Gross, M.L.3
  • 9
    • 36249009481 scopus 로고    scopus 로고
    • Realistic modeling of ion cloud motion in a Fourier transform ion cyclotron resonance cell by use of a particle-in-cell approach
    • 10.1002/rcm.3234 1:CAS:528:DC%2BD2sXhtlKktLfM
    • Nikolaev, E.N., Heeren, R.M.A., Popov, A.M., Pozdneev, A.V., Chingin, K.S.: Realistic modeling of ion cloud motion in a Fourier transform ion cyclotron resonance cell by use of a particle-in-cell approach. Rapid Commun. Mass Spectrom. 21, 3527-3546 (2007)
    • (2007) Rapid Commun. Mass Spectrom. , vol.21 , pp. 3527-3546
    • Nikolaev, E.N.1    Heeren, R.M.A.2    Popov, A.M.3    Pozdneev, A.V.4    Chingin, K.S.5
  • 10
    • 0001200142 scopus 로고
    • Evolution of an ion cloud in a Fourier transform ion cyclotron resonance mass spectrometer during signal detection: Its influence on spectral line shape and position
    • 10.1016/0168-1176(95)04233-B 1:CAS:528:DyaK2MXhtVShsbvF
    • Nikolaev, E.N., Miluchihin, N., Inoue, M.: Evolution of an ion cloud in a Fourier transform ion cyclotron resonance mass spectrometer during signal detection: its influence on spectral line shape and position. Int. J. Mass Spectrom. Ion Processes 148(3), 145-157 (1995)
    • (1995) Int. J. Mass Spectrom. Ion Processes , vol.148 , Issue.3 , pp. 145-157
    • Nikolaev, E.N.1    Miluchihin, N.2    Inoue, M.3
  • 11
    • 84856283788 scopus 로고    scopus 로고
    • Fourier transform ion cyclotron resonance mass resolution and dynamic range limits calculated by computer modeling of ion cloud motion
    • 10.1007/s13361-011-0268-8 1:CAS:528:DC%2BC38XltVahsro%3D
    • Vladimirov, G., Hendrickson, C.L., Blakney, G.T., Marshall, A.G., Heeren, R.M., Nikolaev, E.N.: Fourier transform ion cyclotron resonance mass resolution and dynamic range limits calculated by computer modeling of ion cloud motion. J. Am. Soc Mass Spectrom. 23(2), 375-384 (2012)
    • (2012) J. Am. Soc Mass Spectrom. , vol.23 , Issue.2 , pp. 375-384
    • Vladimirov, G.1    Hendrickson, C.L.2    Blakney, G.T.3    Marshall, A.G.4    Heeren, R.M.5    Nikolaev, E.N.6
  • 12
    • 78650136454 scopus 로고    scopus 로고
    • Fourier transform ion cyclotron resonance cell with dynamic harmonization of the electric field in the whole volume by shaping of the excitation and detection electrode assembly
    • 10.1002/rcm.4838 1:CAS:528:DC%2BC3cXhsFCksbjK
    • Boldin, I.A., Nikolaev, E.N.: Fourier transform ion cyclotron resonance cell with dynamic harmonization of the electric field in the whole volume by shaping of the excitation and detection electrode assembly. Rapid ¡ommun. Mass Spectrom. 25, 122-126 (2011)
    • (2011) Rapid ¡Ommun. Mass Spectrom. , vol.25 , pp. 122-126
    • Boldin, I.A.1    Nikolaev, E.N.2
  • 13
    • 79959999382 scopus 로고    scopus 로고
    • Initial experimental characterization of a new ultra-high resolution FTICR cell with dynamic harmonization
    • 10.1007/s13361-011-0125-9 1:CAS:528:DC%2BC3MXnt1OhsLg%3D
    • Nikolaev, E.N., Boldin, I.A., Jertz, R., Baykut, G.: Initial experimental characterization of a new ultra-high resolution FTICR cell with dynamic harmonization. J. Am. Soc. Mass Spectrom. 22(7), 1125-1133 (2011)
    • (2011) J. Am. Soc. Mass Spectrom. , vol.22 , Issue.7 , pp. 1125-1133
    • Nikolaev, E.N.1    Boldin, I.A.2    Jertz, R.3    Baykut, G.4
  • 16
    • 0033452574 scopus 로고    scopus 로고
    • Fourier transform ion cyclotron resonance mass spectrometry in a high homogeneity 25 Tesla resistive magnet
    • 10.1016/S1044-0305(98)00152-4 1:CAS:528:DyaK1MXhsFyktLs%3D
    • Shi, S.D.-H., Drader, J.J., Hendrickson, C.L., Marshall, A.G.: Fourier transform ion cyclotron resonance mass spectrometry in a high homogeneity 25 Tesla resistive magnet. J. Am. Soc. Mass Spectrom. 10, 265-268 (1999)
    • (1999) J. Am. Soc. Mass Spectrom. , vol.10 , pp. 265-268
    • Shi, S.-H.1    Drader, J.J.2    Hendrickson, C.L.3    Marshall, A.G.4
  • 18
    • 0348017701 scopus 로고
    • The effects of residual spatial magnetic field gradients on Fourier transform ion cyclotron resonance spectra
    • 10.1016/0168-1176(86)80012-X 1:CAS:528:DyaL2sXkt1Ojtg%3D%3D
    • Laukien, F.H.: The effects of residual spatial magnetic field gradients on Fourier transform ion cyclotron resonance spectra. Int. J. Mass Spectrom. Ion Processes 73, 81-107 (1986)
    • (1986) Int. J. Mass Spectrom. Ion Processes , vol.73 , pp. 81-107
    • Laukien, F.H.1
  • 19
    • 36849118375 scopus 로고
    • Electrical current shims for correcting magnetic fields
    • 10.1063/1.1717338
    • Anderson, W.A.: Electrical current shims for correcting magnetic fields. Rev. Sci. Instrum. 32, 241-250 (1961)
    • (1961) Rev. Sci. Instrum. , vol.32 , pp. 241-250
    • Anderson, W.A.1
  • 24
    • 84887262558 scopus 로고    scopus 로고
    • A family of large-stencil discrete Laplacian approximations in three-dimensions
    • O'Reilly, R.C., Beck, J.M. A family of large-stencil discrete Laplacian approximations in three-dimensions. Int. J. Numer. Methods Eng. 1-16 (2006)
    • (2006) Int. J. Numer. Methods Eng. , pp. 1-16
    • O'Reilly, R.C.1    Beck, J.M.2