메뉴 건너뛰기




Volumn 16, Issue 7, 2016, Pages 835-841

Differences in bone mineral density of fixation points between lumbar cortical and traditional pedicle screws

Author keywords

Bone mineral density; Cortical bone trajectory screw; Hounsfield units; Lumbar cortical screw; Lumbar pedicle screw; Quantitative computed tomogaphy

Indexed keywords

AGED; ARTICLE; BONE DENSITY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CORTICAL BONE; CORTICAL BONE TRAJECTORY PEDICLE SCREW; CROSS-SECTIONAL STUDY; FEMALE; FRACTURE FIXATION; GROUPS BY AGE; HUMAN; LUMBAR VERTEBRA; MAJOR CLINICAL STUDY; MALE; OBSERVATIONAL STUDY; PEDICLE SCREW; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; TRADITIONAL LUMBAR PEDICLE SCREW; ADULT; ADVERSE EFFECTS; COMPARATIVE STUDY; DEVICES; DIAGNOSTIC IMAGING; MIDDLE AGED; PROCEDURES; SPINE FUSION; SURGERY; VERY ELDERLY; X-RAY COMPUTED TOMOGRAPHY;

EID: 84954306152     PISSN: 15299430     EISSN: 18781632     Source Type: Journal    
DOI: 10.1016/j.spinee.2015.11.034     Document Type: Article
Times cited : (53)

References (28)
  • 1
    • 34447305748 scopus 로고    scopus 로고
    • Complications of thoracic pedicle screws in scoliosis treatment
    • [1] Di Silvestre, M., Parisini, P., Lolli, F., Bakaloudis, G., Complications of thoracic pedicle screws in scoliosis treatment. Spine 32 (2007), 1655–1661.
    • (2007) Spine , vol.32 , pp. 1655-1661
    • Di Silvestre, M.1    Parisini, P.2    Lolli, F.3    Bakaloudis, G.4
  • 2
    • 0027509721 scopus 로고
    • Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report
    • [2] McLain, R.F., Sparling, E., Benson, D.R., Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report. J Bone Joint Surg Am 75 (1993), 162–167.
    • (1993) J Bone Joint Surg Am , vol.75 , pp. 162-167
    • McLain, R.F.1    Sparling, E.2    Benson, D.R.3
  • 3
    • 64849089881 scopus 로고    scopus 로고
    • Cortical bone trajectory for lumbar pedicle screws
    • [3] Santoni, B.G., Hynes, R.A., McGilvray, K.C., et al. Cortical bone trajectory for lumbar pedicle screws. Spine J 9 (2009), 366–373.
    • (2009) Spine J , vol.9 , pp. 366-373
    • Santoni, B.G.1    Hynes, R.A.2    McGilvray, K.C.3
  • 4
    • 84908436166 scopus 로고    scopus 로고
    • Effect of physiological loads on cortical and traditional pedicle screw fixation
    • [4] Baluch, D.A., Patel, A.A., Lullo, B., et al. Effect of physiological loads on cortical and traditional pedicle screw fixation. Spine 39 (2014), E1297–302.
    • (2014) Spine , vol.39 , pp. E1297-302
    • Baluch, D.A.1    Patel, A.A.2    Lullo, B.3
  • 5
    • 84881012172 scopus 로고    scopus 로고
    • The “medio-latero-superior trajectory technique”: an alternative cortical trajectory for pedicle fixation
    • [5] Mobbs, R.J., The “medio-latero-superior trajectory technique”: an alternative cortical trajectory for pedicle fixation. Orthop Surg 5 (2013), 56–59.
    • (2013) Orthop Surg , vol.5 , pp. 56-59
    • Mobbs, R.J.1
  • 7
    • 84933496667 scopus 로고    scopus 로고
    • Short-term results of transforaminal lumbar interbody fusion using pedicle screw with cortical bone trajectory compared with conventional trajectory
    • [7] Kasukawa, Y., Miyakoshi, N., Hongo, M., Ishikawa, Y., Kudo, D., Shimada, Y., Short-term results of transforaminal lumbar interbody fusion using pedicle screw with cortical bone trajectory compared with conventional trajectory. Asian Spine J 9 (2015), 440–448.
    • (2015) Asian Spine J , vol.9 , pp. 440-448
    • Kasukawa, Y.1    Miyakoshi, N.2    Hongo, M.3    Ishikawa, Y.4    Kudo, D.5    Shimada, Y.6
  • 8
    • 84897667745 scopus 로고    scopus 로고
    • Novel placement of cortical bone trajectory screws in previously instrumented pedicles for adjacent-segment lumbar disease using CT image-guided navigation
    • [8] Rodriguez, A., Neal, M.T., Liu, A., Somasundaram, A., Hsu, W., Branch, C.L. Jr, Novel placement of cortical bone trajectory screws in previously instrumented pedicles for adjacent-segment lumbar disease using CT image-guided navigation. Neurosurg Focus, 36, 2014, E9.
    • (2014) Neurosurg Focus , vol.36 , pp. E9
    • Rodriguez, A.1    Neal, M.T.2    Liu, A.3    Somasundaram, A.4    Hsu, W.5    Branch, C.L.6
  • 9
    • 84862946227 scopus 로고    scopus 로고
    • The insertional torque of a pedicle screw has a positive correlation with bone mineral density in posterior lumbar pedicle screw fixation
    • [9] Lee, J., Lee, J., Park, J., Shin, Y., The insertional torque of a pedicle screw has a positive correlation with bone mineral density in posterior lumbar pedicle screw fixation. J Bone Joint Surg Br 94 (2012), 93–97.
    • (2012) J Bone Joint Surg Br , vol.94 , pp. 93-97
    • Lee, J.1    Lee, J.2    Park, J.3    Shin, Y.4
  • 10
    • 0025988460 scopus 로고
    • An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine
    • [10] Soshi, S., Shiba, R., Kondo, H., Murota, K., An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 16 (1991), 1335–1341.
    • (1991) Spine , vol.16 , pp. 1335-1341
    • Soshi, S.1    Shiba, R.2    Kondo, H.3    Murota, K.4
  • 11
    • 67749110199 scopus 로고    scopus 로고
    • An anatomical study of the mid-lateral pars relative to the pedicle footprint in the lower lumbar spine
    • [11] Su, B.W., Kim, P.D., Cha, T.D., et al. An anatomical study of the mid-lateral pars relative to the pedicle footprint in the lower lumbar spine. Spine 34 (2009), 1355–1362.
    • (2009) Spine , vol.34 , pp. 1355-1362
    • Su, B.W.1    Kim, P.D.2    Cha, T.D.3
  • 12
    • 84935458017 scopus 로고    scopus 로고
    • Pedicle screw placement in the lumbar spine: effect of trajectory and screw design on acute biomechanical purchase
    • [12] Wray, S., Mimran, R., Vadapalli, S., Shetye, S.S., McGilvray, K.C., Puttlitz, C.M., Pedicle screw placement in the lumbar spine: effect of trajectory and screw design on acute biomechanical purchase. J Neurosurg Spine 22 (2015), 503–510.
    • (2015) J Neurosurg Spine , vol.22 , pp. 503-510
    • Wray, S.1    Mimran, R.2    Vadapalli, S.3    Shetye, S.S.4    McGilvray, K.C.5    Puttlitz, C.M.6
  • 13
    • 2442652872 scopus 로고    scopus 로고
    • In vitro and in vivo spiral CT to determine bone mineral density: initial experience in patients at risk for osteoporosis 1
    • [13] Link, T.M., Koppers, B.B., Licht, T., Bauer, J., Lu, Y., Rummeny, E.J., In vitro and in vivo spiral CT to determine bone mineral density: initial experience in patients at risk for osteoporosis 1. Radiology 231 (2004), 805–811.
    • (2004) Radiology , vol.231 , pp. 805-811
    • Link, T.M.1    Koppers, B.B.2    Licht, T.3    Bauer, J.4    Lu, Y.5    Rummeny, E.J.6
  • 14
    • 0036139134 scopus 로고    scopus 로고
    • Measurement of bone mineral density at the spine and proximal femur by volumetric quantitative computed tomography and dual-energy X-ray absorptiometry in elderly women with and without vertebral fractures
    • [14] Lang, T., Guglielmi, G., Van Kuijk, C., De Serio, A., Cammisa, M., Genant, H., Measurement of bone mineral density at the spine and proximal femur by volumetric quantitative computed tomography and dual-energy X-ray absorptiometry in elderly women with and without vertebral fractures. Bone 30 (2002), 247–250.
    • (2002) Bone , vol.30 , pp. 247-250
    • Lang, T.1    Guglielmi, G.2    Van Kuijk, C.3    De Serio, A.4    Cammisa, M.5    Genant, H.6
  • 15
    • 84890826380 scopus 로고    scopus 로고
    • Correlation between bone mineral density measured by dual-energy X-ray absorptiometry and Hounsfield units measured by diagnostic CT in lumbar spine
    • [15] Lee, S., Chung, C.K., Oh, S.H., Park, S.B., Correlation between bone mineral density measured by dual-energy X-ray absorptiometry and Hounsfield units measured by diagnostic CT in lumbar spine. J Korean Neurosurg Soc 54 (2013), 384–389.
    • (2013) J Korean Neurosurg Soc , vol.54 , pp. 384-389
    • Lee, S.1    Chung, C.K.2    Oh, S.H.3    Park, S.B.4
  • 16
    • 84904862285 scopus 로고    scopus 로고
    • Use of computed tomography for assessing bone mineral density
    • [16] Schreiber, J.J., Anderson, P.A., Hsu, W.K., Use of computed tomography for assessing bone mineral density. Neurosurg Focus, 37, 2014, E4.
    • (2014) Neurosurg Focus , vol.37 , pp. E4
    • Schreiber, J.J.1    Anderson, P.A.2    Hsu, W.K.3
  • 17
    • 33144465965 scopus 로고    scopus 로고
    • Cortical and trabecular load sharing in the human vertebral body
    • [17] Eswaran, S.K., Gupta, A., Adams, M.F., Keaveny, T.M., Cortical and trabecular load sharing in the human vertebral body. J Bone Miner Res 21 (2006), 307–314.
    • (2006) J Bone Miner Res , vol.21 , pp. 307-314
    • Eswaran, S.K.1    Gupta, A.2    Adams, M.F.3    Keaveny, T.M.4
  • 18
    • 84908439823 scopus 로고    scopus 로고
    • Lumbar pedicle cortical bone trajectory screw
    • [18] Song, T., Hsu, W.K., Ye, T., Lumbar pedicle cortical bone trajectory screw. Chin Med J (Engl) 127 (2014), 3808–3813.
    • (2014) Chin Med J (Engl) , vol.127 , pp. 3808-3813
    • Song, T.1    Hsu, W.K.2    Ye, T.3
  • 19
    • 84896723365 scopus 로고    scopus 로고
    • In vivo analysis of insertional torque during pedicle screwing using cortical bone trajectory technique
    • [19] Matsukawa, K., Yato, Y., Kato, T., Imabayashi, H., Asazuma, T., Nemoto, K., In vivo analysis of insertional torque during pedicle screwing using cortical bone trajectory technique. Spine 39 (2014), E240–5.
    • (2014) Spine , vol.39 , pp. E240-5
    • Matsukawa, K.1    Yato, Y.2    Kato, T.3    Imabayashi, H.4    Asazuma, T.5    Nemoto, K.6
  • 20
    • 79961074746 scopus 로고    scopus 로고
    • Hounsfield units for assessing bone mineral density and strength: a tool for osteoporosis management
    • [20] Schreiber, J.J., Anderson, P.A., Rosas, H.G., Buchholz, A.L., Au, A.G., Hounsfield units for assessing bone mineral density and strength: a tool for osteoporosis management. J Bone Joint Surg Am 93 (2011), 1057–1063.
    • (2011) J Bone Joint Surg Am , vol.93 , pp. 1057-1063
    • Schreiber, J.J.1    Anderson, P.A.2    Rosas, H.G.3    Buchholz, A.L.4    Au, A.G.5
  • 21
    • 0028895230 scopus 로고
    • Spinal bone mineral assessment in postmenopausal women: a comparison between dual X-ray absorptiometry and quantitative computed tomography
    • [21] Yu, W., Glüer, C., Grampp, S., et al. Spinal bone mineral assessment in postmenopausal women: a comparison between dual X-ray absorptiometry and quantitative computed tomography. Osteoporos Int 5 (1995), 433–439.
    • (1995) Osteoporos Int , vol.5 , pp. 433-439
    • Yu, W.1    Glüer, C.2    Grampp, S.3
  • 22
    • 0031427801 scopus 로고    scopus 로고
    • Internal fixation in the osteoporotic spine
    • [22] Hu, S.S., Internal fixation in the osteoporotic spine. Spine 22 (1997), 43S–48S.
    • (1997) Spine , vol.22 , pp. 43S-48S
    • Hu, S.S.1
  • 23
    • 34247194211 scopus 로고    scopus 로고
    • Incidence and economic burden of osteoporosis-related fractures in the United States, 2005–2025
    • [23] Burge, R., Dawson-Hughes, B., Solomon, D.H., Wong, J.B., King, A., Tosteson, A., Incidence and economic burden of osteoporosis-related fractures in the United States, 2005–2025. J Bone Miner Res 22 (2007), 465–475.
    • (2007) J Bone Miner Res , vol.22 , pp. 465-475
    • Burge, R.1    Dawson-Hughes, B.2    Solomon, D.H.3    Wong, J.B.4    King, A.5    Tosteson, A.6
  • 24
    • 18144371647 scopus 로고    scopus 로고
    • Hydroxyapatite-coating of pedicle screws improves resistance against pull-out force in the osteoporotic canine lumbar spine model: a pilot study
    • [24] Hasegawa, T., Inufusa, A., Imai, Y., Mikawa, Y., Lim, T.-H., An, H.S., Hydroxyapatite-coating of pedicle screws improves resistance against pull-out force in the osteoporotic canine lumbar spine model: a pilot study. Spine J 5 (2005), 239–243.
    • (2005) Spine J , vol.5 , pp. 239-243
    • Hasegawa, T.1    Inufusa, A.2    Imai, Y.3    Mikawa, Y.4    Lim, T.-H.5    An, H.S.6
  • 25
    • 34748828574 scopus 로고    scopus 로고
    • Increasing pedicle screw anchoring in the osteoporotic spine by cement injection through the implant
    • [25] Fransen, P., Increasing pedicle screw anchoring in the osteoporotic spine by cement injection through the implant. J Neurosurg Spine 7 (2007), 366–369.
    • (2007) J Neurosurg Spine , vol.7 , pp. 366-369
    • Fransen, P.1
  • 26
    • 0032810055 scopus 로고    scopus 로고
    • The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures
    • [26] Bai, B., Jazrawi, L.M., Kummer, F.J., Spivak, J.M., The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures. Spine, 24, 1999, 1521.
    • (1999) Spine , vol.24 , pp. 1521
    • Bai, B.1    Jazrawi, L.M.2    Kummer, F.J.3    Spivak, J.M.4
  • 27
    • 0025100436 scopus 로고
    • Cancellous bone remodeling in type I (postmenopausal) osteoporosis: quantitative assessment of rates of formation, resorption, and bone loss at tissue and cellular levels
    • [27] Eriksen, E.F., Hodgson, S.F., Eastell, R., Riggs, B.L., Cedel, S.L., O'Fallon, W.M., Cancellous bone remodeling in type I (postmenopausal) osteoporosis: quantitative assessment of rates of formation, resorption, and bone loss at tissue and cellular levels. J Bone Miner Res 5 (1990), 311–319.
    • (1990) J Bone Miner Res , vol.5 , pp. 311-319
    • Eriksen, E.F.1    Hodgson, S.F.2    Eastell, R.3    Riggs, B.L.4    Cedel, S.L.5    O'Fallon, W.M.6
  • 28
    • 0029758799 scopus 로고    scopus 로고
    • The role of imaging and in situ biomechanical testing in assessing pedicle screw pull-out strength
    • [28] Myers, B.S., Belmont, P.J. Jr, Richardson, W.J., Yu, J.R., Harper, K.D., Nightingale, R.W., The role of imaging and in situ biomechanical testing in assessing pedicle screw pull-out strength. Spine 21 (1996), 1962–1968.
    • (1996) Spine , vol.21 , pp. 1962-1968
    • Myers, B.S.1    Belmont, P.J.2    Richardson, W.J.3    Yu, J.R.4    Harper, K.D.5    Nightingale, R.W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.