-
1
-
-
0028912061
-
Percutaneous iliosacral screw fixation: early treatment for unstable posterior pelvic ring disruptions
-
COI: 1:STN:280:DyaK2M3gsFCqtg%3D%3D, PID: 7897737
-
Shuler TE, Boone DC, Gruen GS, Peitzman AB (1995) Percutaneous iliosacral screw fixation: early treatment for unstable posterior pelvic ring disruptions. J Trauma 38:453–458
-
(1995)
J Trauma
, vol.38
, pp. 453-458
-
-
Shuler, T.E.1
Boone, D.C.2
Gruen, G.S.3
Peitzman, A.B.4
-
2
-
-
0029314802
-
Early results of percutaneous iliosacral screws placed with the patient in the supine position
-
PID: 7623172
-
Routt ML Jr, Kregor PJ, Simonian PT, Mayo KA (1995) Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma 9:207–214
-
(1995)
J Orthop Trauma
, vol.9
, pp. 207-214
-
-
Routt, M.L.1
Kregor, P.J.2
Simonian, P.T.3
Mayo, K.A.4
-
3
-
-
84881218795
-
Minimally invasive treatment for pubic ramus fractures combined with a sacroiliac joint complex injury
-
PID: 23756715
-
Yu X, Tang M, Zhou Z, Peng X, Wu T, Sun Y (2013) Minimally invasive treatment for pubic ramus fractures combined with a sacroiliac joint complex injury. Int Orthop 37:1547–1554. doi:10.1007/s00264-013-1954-x
-
(2013)
Int Orthop
, vol.37
, pp. 1547-1554
-
-
Yu, X.1
Tang, M.2
Zhou, Z.3
Peng, X.4
Wu, T.5
Sun, Y.6
-
4
-
-
84872790260
-
Intraoperative computed tomography with integrated navigation in percutaneous iliosacral screwing
-
PID: 23068140
-
Peng KT, Li YY, Hsu WH, Wu MH, Yang JT, Hsu CH, Huang TJ (2013) Intraoperative computed tomography with integrated navigation in percutaneous iliosacral screwing. Injury 44:203–208. doi:10.1016/j.injury.2012.09.017
-
(2013)
Injury
, vol.44
, pp. 203-208
-
-
Peng, K.T.1
Li, Y.Y.2
Hsu, W.H.3
Wu, M.H.4
Yang, J.T.5
Hsu, C.H.6
Huang, T.J.7
-
5
-
-
0036172601
-
Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws
-
Hinsche AF, Giannoudis PV, Smith RM (2002) Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws. Clin Orthop Relat Res 135–144
-
(2002)
Clin Orthop Relat Res
, pp. 135-144
-
-
Hinsche, A.F.1
Giannoudis, P.V.2
Smith, R.M.3
-
6
-
-
0029789346
-
Proximity of iliosacral screws to neurovascular structures after internal fixation
-
Templeman D, Schmidt A, Freese J, Weisman I (1996) Proximity of iliosacral screws to neurovascular structures after internal fixation. Clin Orthop Relat Res 194–198
-
(1996)
Clin Orthop Relat Res
, pp. 194-198
-
-
Templeman, D.1
Schmidt, A.2
Freese, J.3
Weisman, I.4
-
7
-
-
84886719351
-
An evaluation of three-dimensional image-guided technologies in percutaneous pelvic and acetabular lag screw placement
-
PID: 23830362
-
Xu P, Wang H, Liu ZY, Mu WD, Xu SH, Wang LB, Chen C, Cavanaugh JM (2013) An evaluation of three-dimensional image-guided technologies in percutaneous pelvic and acetabular lag screw placement. J Surg Res 185:338–346. doi:10.1016/j.jss.2013.05.074
-
(2013)
J Surg Res
, vol.185
, pp. 338-346
-
-
Xu, P.1
Wang, H.2
Liu, Z.Y.3
Mu, W.D.4
Xu, S.H.5
Wang, L.B.6
Chen, C.7
Cavanaugh, J.M.8
-
8
-
-
80054011171
-
Factors influencing the accuracy of iliosacral screw placement in trauma patients
-
PID: 20640933
-
Grossterlinden L, Rueger J, Catala-Lehnen P, Rupprecht M, Lehmann W, Rucker A, Briem D (2011) Factors influencing the accuracy of iliosacral screw placement in trauma patients. Int Orthop 35:1391–1396. doi:10.1007/s00264-010-1092-7
-
(2011)
Int Orthop
, vol.35
, pp. 1391-1396
-
-
Grossterlinden, L.1
Rueger, J.2
Catala-Lehnen, P.3
Rupprecht, M.4
Lehmann, W.5
Rucker, A.6
Briem, D.7
-
9
-
-
84864367875
-
Screw placement for acetabular fractures: which navigation modality (2-dimensional vs. 3-dimensional) should be used? An experimental study
-
PID: 22357092
-
Gras F, Marintschev I, Klos K, Muckley T, Hofmann GO, Kahler DM (2012) Screw placement for acetabular fractures: which navigation modality (2-dimensional vs. 3-dimensional) should be used? An experimental study. J Orthop Trauma 26:466–473. doi:10.1097/Bot.0b013e318234d443
-
(2012)
J Orthop Trauma
, vol.26
, pp. 466-473
-
-
Gras, F.1
Marintschev, I.2
Klos, K.3
Muckley, T.4
Hofmann, G.O.5
Kahler, D.M.6
-
10
-
-
84878636475
-
Cement augmentation of the navigated iliosacral screw in the treatment of insufficiency fractures of the sacrum. A new method using modified implants
-
PID: 23553117
-
Wahnert D, Raschke MJ, Fuchs T (2013) Cement augmentation of the navigated iliosacral screw in the treatment of insufficiency fractures of the sacrum. A new method using modified implants. Int Orthop 37:1147–1150. doi:10.1007/s00264-013-1875-8
-
(2013)
Int Orthop
, vol.37
, pp. 1147-1150
-
-
Wahnert, D.1
Raschke, M.J.2
Fuchs, T.3
-
11
-
-
2542497793
-
Computer-guidance in percutaneous screw stabilization of the iliosacral joint
-
Arand M, Kinzl L, Gebhard F (2004) Computer-guidance in percutaneous screw stabilization of the iliosacral joint. Clin Orthop Relat Res 201–207. doi:10.1097/01.blo.0000128644.46013.08
-
(2004)
Clin Orthop Relat Res
, pp. 201-207
-
-
Arand, M.1
Kinzl, L.2
Gebhard, F.3
-
12
-
-
84898832152
-
Iliosacral screw insertion using CT-3D-fluoroscopy matching navigation
-
Takao M, Nishii T, Sakai T, Yoshikawa H, Sugano N (2014) Iliosacral screw insertion using CT-3D-fluoroscopy matching navigation. Inj Int J Care Inj 45:988–994. doi:10.1016/j.injury.2014.01.015
-
(2014)
Inj Int J Care Inj
, vol.45
, pp. 988-994
-
-
Takao, M.1
Nishii, T.2
Sakai, T.3
Yoshikawa, H.4
Sugano, N.5
-
13
-
-
84895066105
-
The use of a head-mounted display in oral implantology: a feasibility study
-
PID: 23784224
-
Vigh B, Muller S, Ristow O, Deppe H, Holdstock S, den Hollander J, Navab N, Steiner T, Hohlweg-Majert B (2014) The use of a head-mounted display in oral implantology: a feasibility study. Int J Comput Assist Radiol Surg 9:71–78. doi:10.1007/s11548-013-0912-9
-
(2014)
Int J Comput Assist Radiol Surg
, vol.9
, pp. 71-78
-
-
Vigh, B.1
Muller, S.2
Ristow, O.3
Deppe, H.4
Holdstock, S.5
den Hollander, J.6
Navab, N.7
Steiner, T.8
Hohlweg-Majert, B.9
-
14
-
-
84941733771
-
Augmented reality-guided neurosurgery: accuracy and intraoperative application of an image projection technique
-
Besharati Tabrizi L, Mahvash M (2015) Augmented reality-guided neurosurgery: accuracy and intraoperative application of an image projection technique. J Neurosurg 1–6. doi:10.3171/2014.9.JNS141001
-
(2015)
J Neurosurg
, pp. 1-6
-
-
Besharati Tabrizi, L.1
Mahvash, M.2
-
15
-
-
84903633127
-
Stereoscopic augmented reality for laparoscopic surgery
-
PID: 24488352
-
Kang X, Azizian M, Wilson E, Wu K, Martin AD, Kane TD, Peters CA, Cleary K, Shekhar R (2014) Stereoscopic augmented reality for laparoscopic surgery. Surg Endosc 28:2227–2235. doi:10.1007/s00464-014-3433-x
-
(2014)
Surg Endosc
, vol.28
, pp. 2227-2235
-
-
Kang, X.1
Azizian, M.2
Wilson, E.3
Wu, K.4
Martin, A.D.5
Kane, T.D.6
Peters, C.A.7
Cleary, K.8
Shekhar, R.9
-
16
-
-
84919608979
-
Precise positioning of an intraoral distractor using augmented reality in patients with hemifacial microsomia
-
Qu M, Hou Y, Xu Y, Shen C, Zhu M, Xie L, Wang H, Zhang Y, Chai G (2015) Precise positioning of an intraoral distractor using augmented reality in patients with hemifacial microsomia. J Cranio-Maxillofac Surg: Off Publ Eur Assoc Cranio-Maxillofac Surg 43:106–112. doi:10.1016/j.jcms.2014.10.019
-
(2015)
J Cranio-Maxillofac Surg: Off Publ Eur Assoc Cranio-Maxillofac Surg
, vol.43
, pp. 106-112
-
-
Qu, M.1
Hou, Y.2
Xu, Y.3
Shen, C.4
Zhu, M.5
Xie, L.6
Wang, H.7
Zhang, Y.8
Chai, G.9
-
17
-
-
84881574937
-
Real-time in situ three-dimensional integral videography and surgical navigation using augmented reality: a pilot study
-
PID: 23703710
-
Suenaga H, Hoang Tran H, Liao H, Masamune K, Dohi T, Hoshi K, Mori Y, Takato T (2013) Real-time in situ three-dimensional integral videography and surgical navigation using augmented reality: a pilot study. Int J Oral Sci 5:98–102. doi:10.1038/ijos.2013.26
-
(2013)
Int J Oral Sci
, vol.5
, pp. 98-102
-
-
Suenaga, H.1
Hoang Tran, H.2
Liao, H.3
Masamune, K.4
Dohi, T.5
Hoshi, K.6
Mori, Y.7
Takato, T.8
-
18
-
-
84885392707
-
A novel 3D guidance system using augmented reality for percutaneous vertebroplasty: technical note
-
PID: 23952323
-
Abe Y, Sato S, Kato K, Hyakumachi T, Yanagibashi Y, Ito M, Abumi K (2013) A novel 3D guidance system using augmented reality for percutaneous vertebroplasty: technical note. J Neurosurg Spine 19:492–501. doi:10.3171/2013.7.spine12917
-
(2013)
J Neurosurg Spine
, vol.19
, pp. 492-501
-
-
Abe, Y.1
Sato, S.2
Kato, K.3
Hyakumachi, T.4
Yanagibashi, Y.5
Ito, M.6
Abumi, K.7
-
19
-
-
84930699188
-
Development of a surgical navigation system based on augmented reality using an optical see-through head-mounted display
-
PID: 25882923
-
Chen X, Xu L, Wang Y, Wang H, Wang F, Zeng X, Wang Q, Egger J (2015) Development of a surgical navigation system based on augmented reality using an optical see-through head-mounted display. J Biomed Inform 55:124–131. doi:10.1016/j.jbi.2015.04.003
-
(2015)
J Biomed Inform
, vol.55
, pp. 124-131
-
-
Chen, X.1
Xu, L.2
Wang, Y.3
Wang, H.4
Wang, F.5
Zeng, X.6
Wang, Q.7
Egger, J.8
-
20
-
-
30944447863
-
An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws
-
PID: 16418646
-
Smith HE, Yuan PS, Sasso R, Papadopolous S, Vaccaro AR (2006) An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws. Spine 31:234–238
-
(2006)
Spine
, vol.31
, pp. 234-238
-
-
Smith, H.E.1
Yuan, P.S.2
Sasso, R.3
Papadopolous, S.4
Vaccaro, A.R.5
-
21
-
-
84930381406
-
Fluoroscopically assisted computer navigation enables accurate percutaneous screw placement for pelvic and acetabular fracture fixation
-
PID: 25683211
-
Wong JM, Bewsher S, Yew J, Bucknill A, de Steiger R (2015) Fluoroscopically assisted computer navigation enables accurate percutaneous screw placement for pelvic and acetabular fracture fixation. Injury 46:1064–1068. doi:10.1016/j.injury.2015.01.038
-
(2015)
Injury
, vol.46
, pp. 1064-1068
-
-
Wong, J.M.1
Bewsher, S.2
Yew, J.3
Bucknill, A.4
de Steiger, R.5
-
22
-
-
67649791453
-
Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure
-
PID: 19034594
-
Zwingmann J, Konrad G, Kotter E, Sudkamp NP, Oberst M (2009) Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure. Clin Orthop Relat Res 467:1833–1838. doi:10.1007/s11999-008-0632-6
-
(2009)
Clin Orthop Relat Res
, vol.467
, pp. 1833-1838
-
-
Zwingmann, J.1
Konrad, G.2
Kotter, E.3
Sudkamp, N.P.4
Oberst, M.5
-
23
-
-
0031266643
-
Iliosacral screw fixation: early complications of the percutaneous technique
-
PID: 9415865
-
Routt ML Jr, Simonian PT, Mills WJ (1997) Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma 11:584–589
-
(1997)
J Orthop Trauma
, vol.11
, pp. 584-589
-
-
Routt, M.L.1
Simonian, P.T.2
Mills, W.J.3
-
24
-
-
0346688142
-
Optical versus video see-through mead-mounted displays in medical visualization
-
Rolland JP, Fuchs H (2000) Optical versus video see-through mead-mounted displays in medical visualization. Presence Teleop Virt 9:287–309. doi:10.1162/105474600566808
-
(2000)
Presence Teleop Virt
, vol.9
, pp. 287-309
-
-
Rolland, J.P.1
Fuchs, H.2
-
25
-
-
0842309828
-
Augmented reality in surgery
-
PID: 14769575
-
Shuhaiber JH (2004) Augmented reality in surgery. Arch Surg 139:170–174. doi:10.1001/archsurg.139.2.170
-
(2004)
Arch Surg
, vol.139
, pp. 170-174
-
-
Shuhaiber, J.H.1
|