메뉴 건너뛰기




Volumn 19, Issue 4, 2013, Pages 492-501

A novel 3D guidance system using augmented reality for percutaneous vertebroplasty

Author keywords

Augmented reality; Computer assisted surgery; Percutaneous spinal approach; Percutaneous vertebroplasty; Technique

Indexed keywords

POLY(METHYL METHACRYLATE);

EID: 84885392707     PISSN: 15475654     EISSN: 15475646     Source Type: Journal    
DOI: 10.3171/2013.7.SPINE12917     Document Type: Article
Times cited : (122)

References (27)
  • 1
    • 80655145838 scopus 로고    scopus 로고
    • A novel cost-effective computer-assisted imaging technology for accurate placement of thoracic pedicle screws
    • Abe Y, Ito M, Abumi K, Kotani Y, Sudo H, Minami A: A novel cost-effective computer-assisted imaging technology for accurate placement of thoracic pedicle screws. Technical note. J Neurosurg Spine 15:479-485, 2011.
    • (2011) Technical Note, J Neurosurg Spine , vol.15 , pp. 479-485
    • Abe, Y.1    Ito, M.2    Abumi, K.3    Kotani, Y.4    Sudo, H.5    Minami, A.6
  • 2
    • 0034655411 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for pain relief and spinal stabilization
    • Barr JD, Barr MS, Lemley TJ, McCann RM: Percutaneous vertebroplasty for pain relief and spinal stabilization. Spine (Phila Pa 1976) 25:923-928, 2000.
    • (2000) Spine (Phila Pa 1976) , vol.25 , pp. 923-928
    • Barr, J.D.1    Barr, M.S.2    Lemley, T.J.3    McCann, R.M.4
  • 3
    • 70349863374 scopus 로고    scopus 로고
    • C-arm CT-guided 3D navigation of percutaneous interventions
    • Ger
    • Becker HC, Meissner O, Waggershauser T: [C-arm CT-guided 3D navigation of percutaneous interventions.] Radiologe 49:852-855, 2009 (Ger).
    • (2009) Radiologe , vol.49 , pp. 852-855
    • Becker, H.C.1    Meissner, O.2    Waggershauser, T.3
  • 4
    • 77953084095 scopus 로고    scopus 로고
    • The virtual mirror: A new interaction paradigm for augmented reality environments
    • Bichlmeier C, Heining SM, Feuerstein M, Navab N: The virtual mirror: A new interaction paradigm for augmented reality environments. IEEE Trans Med Imaging 28:1498-1510, 2009.
    • (2009) IEEE Trans Med Imaging , vol.28 , pp. 1498-1510
    • Bichlmeier, C.1    Heining, S.M.2    Feuerstein, M.3    Navab, N.4
  • 5
    • 77954473116 scopus 로고    scopus 로고
    • 3D visualization tool for minimally invasive discectomy assistance
    • Bisson M, Cheriet F, Parent S: 3D visualization tool for minimally invasive discectomy assistance. Stud Health Technol Inform 158:55-60, 2010.
    • (2010) Stud Health Technol Inform , vol.158 , pp. 55-60
    • Bisson, M.1    Cheriet, F.2    Parent, S.3
  • 6
    • 0032846650 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: An open prospective study
    • Cortet B, Cotten A, Boutry N, Flipo RM, Duquesnoy B, Chastanet P, et al: Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: an open prospective study. J Rheumatol 26:2222-2228, 1999.
    • (1999) J Rheumatol , vol.26 , pp. 2222-2228
    • Cortet, B.1    Cotten, A.2    Boutry, N.3    Flipo, R.M.4    Duquesnoy, B.5    Chastanet, P.6
  • 7
    • 0031778659 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty with polymethylmethacrylate, technique, indications, and results
    • Deramond H, Depriester C, Galibert P, Le Gars D: Percutaneous vertebroplasty with polymethylmethacrylate. Technique, indications, and results. Radiol Clin North Am 36:533-546, 1998.
    • (1998) Radiol Clin North Am , vol.36 , pp. 533-546
    • Deramond, H.1    Depriester, C.2    Galibert, P.3    Le, G.D.4
  • 8
    • 84857819539 scopus 로고    scopus 로고
    • Augmented reality visualization with image overlay for MRI-guided intervention: Accuracy for lumbar spinal procedures with a 1.5-T MRI system
    • Fritz J, U-Thainual P, Ungi T, Flammang AJ, Cho NB, Fichtinger G, et al: Augmented reality visualization with image overlay for MRI-guided intervention: accuracy for lumbar spinal procedures with a 1.5-T MRI system. AJR Am J Roentgenol 198:W266-W273, 2012.
    • (2012) AJR Am J Roentgenol , vol.198
    • Fritz, J.1    U-Thainual, P.2    Ungi, T.3    Flammang, A.J.4    Cho, N.B.5    Fichtinger, G.6
  • 9
    • 0043165850 scopus 로고
    • Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty
    • Fr
    • Galibert P, Deramond H, Rosat P, Le Gars D: [Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty.] Neurochirurgie 33:166-168, 1987 (Fr).
    • (1987) Neurochirurgie , vol.33 , pp. 166-168
    • Galibert, P.1    Deramond, H.2    Rosat, P.3    Le Gars, D.4
  • 10
    • 44249116921 scopus 로고    scopus 로고
    • Low cost augmented reality for training of MRI-guided needle biopsy of the spine
    • George S, Kesavadas T: Low cost augmented reality for training of MRI-guided needle biopsy of the spine. Stud Health Technol Inform 132:138-140, 2008.
    • (2008) Stud Health Technol Inform , vol.132 , pp. 138-140
    • George, S.1    Kesavadas, T.2
  • 12
    • 0034918914 scopus 로고    scopus 로고
    • Major neurological complications following percutaneous vertebroplasty with polymethylmethacrylate: A case report
    • Harrington KD: Major neurological complications following percutaneous vertebroplasty with polymethylmethacrylate: A case report. J Bone Joint Surg Am 83-A:1070-1073, 2001.
    • (2001) J Bone Joint Surg Am , vol.83-A , pp. 1070-1073
    • Harrington, K.D.1
  • 13
    • 67651159010 scopus 로고    scopus 로고
    • Computer navigation in balloon kyphoplasty reduces the intraoperative radiation exposure
    • Izadpanah K, Konrad G, Südkamp NP, Oberst M: Computer navigation in balloon kyphoplasty reduces the intraoperative radiation exposure. Spine (Phila Pa 1976) 34:1325-1329, 2009.
    • (2009) Spine (Phila Pa 1976) , vol.34 , pp. 1325-1329
    • Izadpanah, K.1    Konrad, G.2    Südkamp, N.P.3    Oberst, M.4
  • 14
    • 0036782669 scopus 로고    scopus 로고
    • Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: A case report
    • Lee BJ, Lee SR, Yoo TY: Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: A case report. Spine (Phila Pa 1976) 27:E419-E422, 2002.
    • (2002) Spine (Phila Pa 1976) , vol.27
    • Lee, B.J.1    Lee, S.R.2    Yoo, T.Y.3
  • 15
    • 0032783733 scopus 로고    scopus 로고
    • Vertebroplasty: Clinical experience and follow- up results
    • Martin JB, Jean B, Sugiu K, San Millán Ruíz D, Piotin M, Murphy K, et al: Vertebroplasty: clinical experience and follow- up results. Bone 25 (2 Suppl):11S-15S, 1999.
    • (1999) Bone , vol.25 , Issue.2 SUPPL.
    • Martin, J.B.1    Jean, B.2    Sugiu, K.3    San, M.R.D.4    Piotin, M.5    Murphy, K.6
  • 16
    • 1442302381 scopus 로고    scopus 로고
    • Kyphoplasty and vertebroplasty in fractures in the elderly: Effort and effect
    • Ger
    • Meeder PJ, DaFonseca K, Hillmeier J, Grafe I, Noeldge G, Kasperk C: [Kyphoplasty and vertebroplasty in fractures in the elderly: effort and effect.] Chirurg 74:994-999, 2003 (Ger).
    • (2003) Chirurg , vol.74 , pp. 994-999
    • Meeder, P.J.1    Dafonseca, K.2    Hillmeier, J.3    Grafe, I.4    Noeldge, G.5    Kasperk, C.6
  • 17
    • 73249140742 scopus 로고    scopus 로고
    • Cervical pedicle screw insertion using a computed tomography cutout technique, technical note
    • Miyamoto H, Uno K: Cervical pedicle screw insertion using a computed tomography cutout technique. Technical note. J Neurosurg Spine 11:681-687, 2009.
    • (2009) J Neurosurg Spine , vol.11 , pp. 681-687
    • Miyamoto, H.1    Uno, K.2
  • 18
    • 77954224040 scopus 로고    scopus 로고
    • Camera augmented mobile C-arm (CAMC): Calibration, accuracy study, and clinical applications
    • Navab N, Heining SM, Traub J: Camera augmented mobile C-arm (CAMC): calibration, accuracy study, and clinical applications. IEEE Trans Med Imaging 29:1412-1423, 2010.
    • (2010) IEEE Trans Med Imaging , vol.29 , pp. 1412-1423
    • Navab, N.1    Heining, S.M.2    Traub, J.3
  • 19
    • 35648948435 scopus 로고    scopus 로고
    • Rapid prototype patient-specific drill template for cervical pedicle screw placement
    • Owen BD, Christensen GE, Reinhardt JM, Ryken TC: Rapid prototype patient-specific drill template for cervical pedicle screw placement. Comput Aided Surg 12:303-308, 2007.
    • (2007) Comput Aided Surg , vol.12 , pp. 303-308
    • Owen, B.D.1    Christensen, G.E.2    Reinhardt, J.M.3    Ryken, T.C.4
  • 21
    • 18044402604 scopus 로고    scopus 로고
    • Root and spinal cord compression from methylmethacrylate vertebroplasty
    • Ratliff J, Nguyen T, Heiss J: Root and spinal cord compression from methylmethacrylate vertebroplasty. Spine (Phila Pa 1976) 26:E300-E302, 2001.
    • (2001) Spine (Phila Pa 1976) , vol.26
    • Ratliff, J.1    Nguyen, T.2    Heiss, J.3
  • 22
    • 65249175702 scopus 로고    scopus 로고
    • Engineering patient-specific drill templates and bioabsorbable posterior cervical plates: A feasibility study
    • Ryken TC, Kim J, Owen BD, Christensen GE, Reinhardt JM: Engineering patient-specific drill templates and bioabsorbable posterior cervical plates: A feasibility study. Technical note. J Neurosurg Spine 10:129-132, 2009.
    • (2009) Technical Note, J Neurosurg Spine , vol.10 , pp. 129-132
    • Ryken, T.C.1    Kim, J.2    Owen, B.D.3    Christensen, G.E.4    Reinhardt, J.M.5
  • 24
    • 77749292316 scopus 로고    scopus 로고
    • A volumetric model-based 2D to 3D registration method for measuring kinematics of natural knees with single-plane fluoroscopy
    • Tsai TY, Lu TW, Chen CM, Kuo MY, Hsu HC: A volumetric model-based 2D to 3D registration method for measuring kinematics of natural knees with single-plane fluoroscopy. Med Phys 37:1273-1284, 2010.
    • (2010) Med Phys , vol.37 , pp. 1273-1284
    • Tsai, T.Y.1    Lu, T.W.2    Chen, C.M.3    Kuo, M.Y.4    Hsu, H.C.5
  • 25
    • 79952272770 scopus 로고    scopus 로고
    • Augmented reality visualization using Image- Overlay for MR-guided interventions: System description, feasibility, and initial evaluation in a spine phantom
    • Weiss CR, Marker DR, Fischer GS, Fichtinger G, Machado AJ, Carrino JA: Augmented reality visualization using Image- Overlay for MR-guided interventions: system description, feasibility, and initial evaluation in a spine phantom. AJR Am J Roentgenol 196:W305-W307, 2011.
    • (2011) AJR Am J Roentgenol , vol.196
    • Weiss, C.R.1    Marker, D.R.2    Fischer, G.S.3    Fichtinger, G.4    Machado, A.J.5    Carrino, J.A.6
  • 26
    • 69249185700 scopus 로고    scopus 로고
    • Application of navigation template to fixation of sacral fracture using three-dimensional reconstruction and reverse engineering technique
    • Zhang YZ, Lu S, Xu YQ, Shi JH, Li YB, Feng ZL: Application of navigation template to fixation of sacral fracture using three-dimensional reconstruction and reverse engineering technique. Chin J Traumatol 12:214-217, 2009.
    • (2009) Chin J Traumatol , vol.12 , pp. 214-217
    • Zhang, Y.Z.1    Lu, S.2    Xu, Y.Q.3    Shi, J.H.4    Li, Y.B.5    Feng, Z.L.6
  • 27
    • 0036169233 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for osteoporotic compression fractures: Quantitative prospective evaluation of long-term outcomes
    • Zoarski GH, Snow P, Olan WJ, Stallmeyer MJ, Dick BW, Hebel JR, et al: Percutaneous vertebroplasty for osteoporotic compression fractures: quantitative prospective evaluation of long-term outcomes. J Vasc Interv Radiol 13:139-148, 2002.
    • (2002) J Vasc Interv Radiol , vol.13 , pp. 139-148
    • Zoarski, G.H.1    Snow, P.2    Olan, W.J.3    Stallmeyer, M.J.4    Dick, B.W.5    Hebel, J.R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.