메뉴 건너뛰기




Volumn 5, Issue , 2015, Pages

Quantification of NS1 dengue biomarker in serum via optomagnetic nanocluster detection

Author keywords

[No Author keywords available]

Indexed keywords

BIOLOGICAL MARKER; MAGNETITE NANOPARTICLE; MONOCLONAL ANTIBODY; VIRAL PROTEIN; VIRUS ANTIBODY; VIRUS ANTIGEN;

EID: 84946593699     PISSN: None     EISSN: 20452322     Source Type: Journal    
DOI: 10.1038/srep16145     Document Type: Article
Times cited : (68)

References (36)
  • 2
    • 84876804736 scopus 로고    scopus 로고
    • The global distribution and burden of dengue
    • Bhatt, S. et al. The global distribution and burden of dengue. Nature 496, 504-507 (2013).
    • (2013) Nature , vol.496 , pp. 504-507
    • Bhatt, S.1
  • 4
    • 84866068905 scopus 로고    scopus 로고
    • Dengue tools: Innovative tools and strategies for the surveillance and control of dengue
    • Wilder-Smith, A. et al. Dengue tools: Innovative tools and strategies for the surveillance and control of dengue. Glob. Health Action 5, 1-9 (2012).
    • (2012) Glob. Health Action , vol.5 , pp. 1-9
    • Wilder-Smith, A.1
  • 5
    • 80053453368 scopus 로고    scopus 로고
    • Evaluation of diagnostic tests: Dengue
    • Peeling, R. W. et al. Evaluation of diagnostic tests: dengue. Nat. Rev. Microbiol. 8, S30-S37 (2010).
    • (2010) Nat. Rev. Microbiol. , vol.8 , pp. S30-S37
    • Peeling, R.W.1
  • 6
    • 14744290930 scopus 로고    scopus 로고
    • Laboratory diagnosis of dengue virus infection: Current and future perspectives in clinical diagnosis and public health
    • Kao, C.-L., King, C.-C., Chao, D.-Y., Wu, H.-L. & Chang, G.-J. J. Laboratory diagnosis of dengue virus infection: current and future perspectives in clinical diagnosis and public health. J. Microbiol. Immunol. Infect. 38, 5-16 (2005).
    • (2005) J. Microbiol. Immunol. Infect. , vol.38 , pp. 5-16
    • Kao, C.-L.1    King, C.-C.2    Chao, D.-Y.3    Wu, H.-L.4    Chang, G.-J.J.5
  • 7
    • 0036164518 scopus 로고    scopus 로고
    • Enzyme-linked immunosorbent assay specific to dengue virus type 1 nonstructural protein NS1 reveals circulation of the antigen in the blood during the acute phase of disease in patients experiencing primary or secondary infections
    • Alcon, S. et al. Enzyme-linked immunosorbent assay specific to dengue virus type 1 nonstructural protein NS1 reveals circulation of the antigen in the blood during the acute phase of disease in patients experiencing primary or secondary infections. J. Clin. Microbiol. 40, 376-381 (2002).
    • (2002) J. Clin. Microbiol. , vol.40 , pp. 376-381
    • Alcon, S.1
  • 8
    • 77957094065 scopus 로고    scopus 로고
    • Early diagnosis of dengue infection using a commercial dengue duo rapid test kit for the detection of NS1, IGM, and IGG
    • Wang, S. M. & Sekaran, S. D. Early diagnosis of dengue infection using a commercial dengue duo rapid test kit for the detection of NS1, IGM, and IGG. Am. J. Trop. Med. Hyg. 83, 690-695 (2010).
    • (2010) Am. J. Trop. Med. Hyg. , vol.83 , pp. 690-695
    • Wang, S.M.1    Sekaran, S.D.2
  • 9
    • 77952735699 scopus 로고    scopus 로고
    • Comparison of two dengue NS1 rapid tests for sensitivity, specificity and relationship to viraemia and antibody responses
    • Tricou, V. et al. Comparison of two dengue NS1 rapid tests for sensitivity, specificity and relationship to viraemia and antibody responses. BMC Infect. Dis. 10, 142 (2010).
    • (2010) BMC Infect. Dis. , vol.10 , pp. 142
    • Tricou, V.1
  • 10
    • 79960967477 scopus 로고    scopus 로고
    • Clinical and virological factors influencing the performance of a NS1 antigen-capture assay and potential use as a marker of dengue disease severity
    • Duong, V. et al. Clinical and virological factors influencing the performance of a NS1 antigen-capture assay and potential use as a marker of dengue disease severity. PLoS Negl. Trop. Dis. 5, 1244 (2011).
    • (2011) PLoS Negl. Trop. Dis. , vol.5 , pp. 1244
    • Duong, V.1
  • 11
    • 65549138517 scopus 로고    scopus 로고
    • Diagnostic accuracy of NS1 ELISA and lateral flow rapid tests for dengue sensitivity, specificity and relationship to viraemia and antibody responses
    • Hang, V. T. et al. Diagnostic accuracy of NS1 ELISA and lateral flow rapid tests for dengue sensitivity, specificity and relationship to viraemia and antibody responses. PLoS Negl. Trop. Dis. 3, 1-7 (2009).
    • (2009) PLoS Negl. Trop. Dis. , vol.3 , pp. 1-7
    • Hang, V.T.1
  • 12
    • 84885184664 scopus 로고    scopus 로고
    • Laboratory diagnostics of dengue fever: An emphasis on the role of commercial dengue virus nonstructural protein 1 antigen rapid test
    • Huang, C.-H. et al. Laboratory diagnostics of dengue fever: an emphasis on the role of commercial dengue virus nonstructural protein 1 antigen rapid test. J. Microbiol. Immunol. Infect. 46, 358-365 (2013).
    • (2013) J. Microbiol. Immunol. Infect. , vol.46 , pp. 358-365
    • Huang, C.-H.1
  • 13
    • 84870780557 scopus 로고    scopus 로고
    • Immunospot assay based on fluorescent nanoparticles for Dengue fever detection
    • Linares, E. M., Pannuti, C. S., Kubota, L. T. & Thalhammer, S. Immunospot assay based on fluorescent nanoparticles for Dengue fever detection. Biosens. Bioelectron. 41, 180-185 (2013).
    • (2013) Biosens. Bioelectron. , vol.41 , pp. 180-185
    • Linares, E.M.1    Pannuti, C.S.2    Kubota, L.T.3    Thalhammer, S.4
  • 14
    • 84884129421 scopus 로고    scopus 로고
    • Comparison of surface plasmon resonance, resonant waveguide grating biosensing and enzyme linked immunosorbent assay (ELISA) in the evaluation of a dengue virus immunoassay
    • Hu, D. et al. Comparison of surface plasmon resonance, resonant waveguide grating biosensing and enzyme linked immunosorbent assay (ELISA) in the evaluation of a dengue virus immunoassay. Biosensors 3, 297-311 (2013).
    • (2013) Biosensors , vol.3 , pp. 297-311
    • Hu, D.1
  • 15
    • 84912532959 scopus 로고    scopus 로고
    • Electrochemical detection of dengue virus NS1 protein with a poly(allylamine)/carbon nanotube layered immunoelectrode
    • Silva, M. M. S. et al. Electrochemical detection of dengue virus NS1 protein with a poly(allylamine)/carbon nanotube layered immunoelectrode. J. Chem. Technol. Biotechnol. 90, 194-200 (2014).
    • (2014) J. Chem. Technol. Biotechnol. , vol.90 , pp. 194-200
    • Silva, M.M.S.1
  • 16
    • 84923076305 scopus 로고    scopus 로고
    • Electrical detection of dengue biomarker using egg yolk immunoglobulin as the biological recognition element
    • Figueiredo, A. et al. Electrical detection of dengue biomarker using egg yolk immunoglobulin as the biological recognition element. Sci. Rep. 5, 7865 (2015).
    • (2015) Sci. Rep. , vol.5 , pp. 7865
    • Figueiredo, A.1
  • 17
    • 84963941002 scopus 로고    scopus 로고
    • Novel readout method for molecular diagnostic assays based on optical measurements of magnetic nanobead dynamics
    • Donolato, M. et al. Novel readout method for molecular diagnostic assays based on optical measurements of magnetic nanobead dynamics. Anal. Chem. 87, 1622-1629 (2015).
    • (2015) Anal. Chem. , vol.87 , pp. 1622-1629
    • Donolato, M.1
  • 18
    • 84922327017 scopus 로고    scopus 로고
    • Evaluation of direct versus multi-layer passivation and capture chemistries for nanoparticle-based biosensor applications
    • Sanjaya, K. C., Ranzoni, A., Watterson, D., Young, P. & Cooper, M. A. Evaluation of direct versus multi-layer passivation and capture chemistries for nanoparticle-based biosensor applications. Biosens. Bioelectron. 67, 769-774 (2015).
    • (2015) Biosens. Bioelectron. , vol.67 , pp. 769-774
    • Sanjaya, K.C.1    Ranzoni, A.2    Watterson, D.3    Young, P.4    Cooper, M.A.5
  • 19
    • 84922322857 scopus 로고    scopus 로고
    • Quantification of rolling circle amplified DNA using magnetic nanobeads and a Blu-ray optical pick-up unit
    • Donolato, M. et al. Quantification of rolling circle amplified DNA using magnetic nanobeads and a Blu-ray optical pick-up unit. Biosens. Bioelectron. 67, 649-655 (2014).
    • (2014) Biosens. Bioelectron. , vol.67 , pp. 649-655
    • Donolato, M.1
  • 20
    • 84934919633 scopus 로고    scopus 로고
    • Improved immunoassay sensitivity in serum as a result of polymer-entrapped quantum dots: "Papaya particles"
    • Ranzoni, A., den Hamer, A., Karoli, T., Buechler, J. & Cooper, M. A. Improved immunoassay sensitivity in serum as a result of polymer-entrapped quantum dots: "papaya particles". Anal. Chem. 87, 6150-6157 (2015).
    • (2015) Anal. Chem. , vol.87 , pp. 6150-6157
    • Ranzoni, A.1    Den Hamer, A.2    Karoli, T.3    Buechler, J.4    Cooper, M.A.5
  • 21
    • 84860358391 scopus 로고    scopus 로고
    • One-step homogeneous magnetic nanoparticle immunoassay for biomarker detection directly in blood plasma
    • Ranzoni, A., Sabatte, G., van Ijzendoorn, L. J. & Prins, M. W. J. One-step homogeneous magnetic nanoparticle immunoassay for biomarker detection directly in blood plasma. ACS Nano 6, 3134-3141 (2012).
    • (2012) ACS Nano , vol.6 , pp. 3134-3141
    • Ranzoni, A.1    Sabatte, G.2    Van Ijzendoorn, L.J.3    Prins, M.W.J.4
  • 22
    • 84914145953 scopus 로고    scopus 로고
    • Turn-on optomagnetic bacterial DNA sequence detection using volume-amplified magnetic nanobeads
    • Bejhed, R. S. et al. Turn-on optomagnetic bacterial DNA sequence detection using volume-amplified magnetic nanobeads. Biosens. Bioelectron. 66, 405-411 (2014).
    • (2014) Biosens. Bioelectron. , vol.66 , pp. 405-411
    • Bejhed, R.S.1
  • 23
    • 84877835595 scopus 로고    scopus 로고
    • Click chemistry for drug development and diverse chemical - Biology applications
    • Thirumurugan, P., Matosiuk, D. & Jozwiak, K. Click chemistry for drug development and diverse chemical - biology applications. Chem. Rev. 133, 4905-4979 (2013).
    • (2013) Chem. Rev. , vol.133 , pp. 4905-4979
    • Thirumurugan, P.1    Matosiuk, D.2    Jozwiak, K.3
  • 25
    • 33750820871 scopus 로고    scopus 로고
    • Acceleration of the recognition rate between grafted ligands and receptors with magnetic forces
    • Baudry, J. et al. Acceleration of the recognition rate between grafted ligands and receptors with magnetic forces. Proc. Natl. Acad. Sci. USA 103, 16076-8 (2006).
    • (2006) Proc. Natl. Acad. Sci. USA , vol.103 , pp. 16076-16078
    • Baudry, J.1
  • 26
    • 47749106439 scopus 로고    scopus 로고
    • Factors affecting the antigen-antibody reaction
    • Reverberi, R. & Reverberi, L. Factors affecting the antigen-antibody reaction. Blood Transfus. 5, 227-240 (2007).
    • (2007) Blood Transfus. , vol.5 , pp. 227-240
    • Reverberi, R.1    Reverberi, L.2
  • 27
    • 84902455423 scopus 로고    scopus 로고
    • Magnetic sensing technology for molecular analyses
    • Issadore, D. et al. Magnetic sensing technology for molecular analyses. Lab Chip 14, 2385-97 (2014).
    • (2014) Lab Chip , vol.14 , pp. 2385-2397
    • Issadore, D.1
  • 28
    • 79958830224 scopus 로고    scopus 로고
    • Miniature magnetic resonance system for point-of-care diagnostics
    • Issadore, D. et al. Miniature magnetic resonance system for point-of-care diagnostics. Lab Chip 11, 2282-2287 (2011).
    • (2011) Lab Chip , vol.11 , pp. 2282-2287
    • Issadore, D.1
  • 29
    • 84938632349 scopus 로고    scopus 로고
    • Fast magnetic field-enhanced linear colloidal agglutination immunoassay
    • 150714134125008
    • Daynès, A. et al. Fast magnetic field-enhanced linear colloidal agglutination immunoassay. Anal. Chem. 150714134125008 (2015). doi: 10.1021/acs.analchem.5b00279
    • (2015) Anal. Chem.
    • Daynès, A.1
  • 31
    • 84877267150 scopus 로고    scopus 로고
    • A magneto-DNA nanoparticle system for rapid detection and phenotyping of bacteria
    • Chung, H. J., Castro, C. M., Im, H., Lee, H. & Weissleder, R. A magneto-DNA nanoparticle system for rapid detection and phenotyping of bacteria. Nat. Nanotechnol. 8, 369-75 (2013).
    • (2013) Nat. Nanotechnol. , vol.8 , pp. 369-375
    • Chung, H.J.1    Castro, C.M.2    Im, H.3    Lee, H.4    Weissleder, R.5
  • 32
    • 84877752883 scopus 로고    scopus 로고
    • Magnetic barcode assay for genetic detection of pathogens
    • Liong, M. et al. Magnetic barcode assay for genetic detection of pathogens. Nat. Commun. 4, 1752 (2013).
    • (2013) Nat. Commun. , vol.4 , pp. 1752
    • Liong, M.1
  • 33
    • 84912087074 scopus 로고    scopus 로고
    • Assessing positivity and circulating levels of NS1 in samples from a 2012 dengue outbreak in Rio de Janeiro, Brazil
    • Allonso, D., Meneses, M. D. F., Fernandes, C. a., Ferreira, D. F. & Mohana-Borges, R. Assessing positivity and circulating levels of NS1 in samples from a 2012 dengue outbreak in Rio de Janeiro, Brazil. PLoS One 9, e113634 (2014).
    • (2014) PLoS One , vol.9 , pp. e113634
    • Allonso, D.1    Meneses, M.D.F.2    Fernandes, C.A.3    Ferreira, D.F.4    Mohana-Borges, R.5
  • 34
    • 79955602230 scopus 로고    scopus 로고
    • Dengue: A continuing global threat
    • Guzman, M. G. et al. Dengue: a continuing global threat. Nat. Rev. Microbiol. 8, S7-16 (2010).
    • (2010) Nat. Rev. Microbiol. , vol.8 , pp. S7-16
    • Guzman, M.G.1
  • 35
    • 0025911266 scopus 로고
    • Production of dimer-specific and dengue virus group cross-reactive mouse monoclonal antibodies to the dengue 2 virus non-structural glycoprotein NS1
    • Falconar, a. K. I. & Young, P. R. Production of dimer-specific and dengue virus group cross-reactive mouse monoclonal antibodies to the dengue 2 virus non-structural glycoprotein NS1. J. Gen. Virol. 72, 961-965 (1991).
    • (1991) J. Gen. Virol. , vol.72 , pp. 961-965
    • Falconar, A.K.I.1    Young, P.R.2
  • 36
    • 0027977656 scopus 로고
    • Precise location of sequential dengue virus subcomplex and complex B cell epitopes on the nonstructural-1 glycoprotein
    • Falconar, A. K. I., Young, P. R. & Miles, M. A. Precise location of sequential dengue virus subcomplex and complex B cell epitopes on the nonstructural-1 glycoprotein. Arch. Virol. 137, 315-326 (1994).
    • (1994) Arch. Virol. , vol.137 , pp. 315-326
    • Falconar, A.K.I.1    Young, P.R.2    Miles, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.