-
1
-
-
33750820871
-
Acceleration of the recognition rate between grafted ligands and receptors with magnetic forces
-
Baudry, J.; Rouzeau, C.; Goubault, C.; Robic, C.; Cohen-Tannoudji, L.; Koenig, A.; Bertrand, E.; Bibette, J. Acceleration of the recognition rate between grafted ligands and receptors with magnetic forces Proc. Natl. Acad. Sci. U. S. A. 2006, 103 (44) 16076-16078 10.1073/pnas.0607991103
-
(2006)
Proc. Natl. Acad. Sci. U. S. A.
, vol.103
, Issue.44
, pp. 16076-16078
-
-
Baudry, J.1
Rouzeau, C.2
Goubault, C.3
Robic, C.4
Cohen-Tannoudji, L.5
Koenig, A.6
Bertrand, E.7
Bibette, J.8
-
2
-
-
84862906663
-
Colloidal nanomaterial-based immunoassay
-
Teste, B.; Descroix, S. Colloidal nanomaterial-based immunoassay Nanomedicine 2012, 7 (6) 1917-1923 10.2217/nnm.12.58
-
(2012)
Nanomedicine
, vol.7
, Issue.6
, pp. 1917-1923
-
-
Teste, B.1
Descroix, S.2
-
3
-
-
77049264006
-
The latex fixation test: I. Application to the serologic diagnosis of rheumatoid arthritis
-
Singer, J. M.; Plotz, C. M. The latex fixation test: I. Application to the serologic diagnosis of rheumatoid arthritis Am. J. Med. 1956, 21 (6) 888-892 10.1016/0002-9343(56)90103-6
-
(1956)
Am. J. Med.
, vol.21
, Issue.6
, pp. 888-892
-
-
Singer, J.M.1
Plotz, C.M.2
-
4
-
-
0242354089
-
Femtomolar detection of prostate-specific antigen: an immunoassay based on surface-enhanced Raman scattering and immunogold labels
-
Grubisha, D. S.; Lipert, R. J.; Park, H. Y.; Driskell, J.; Porter, M. D. Femtomolar detection of prostate-specific antigen: an immunoassay based on surface-enhanced Raman scattering and immunogold labels Anal. Chem. 2003, 75 (21) 5936-5943 10.1021/ac034356f
-
(2003)
Anal. Chem.
, vol.75
, Issue.21
, pp. 5936-5943
-
-
Grubisha, D.S.1
Lipert, R.J.2
Park, H.Y.3
Driskell, J.4
Porter, M.D.5
-
5
-
-
58549113984
-
Multiplex protein assays based on real-time magnetic nanotag
-
Osterfeld, S. J.; Yu, H.; Gaster, R. S.; Caramuta, S.; Xu, L.; Han, S. J.; Hall, D. A.; Wilson, R. J.; Sun, S.; White, R. L.; Davis, R. W.; Pourmand, N.; Wang, S. X. Multiplex protein assays based on real-time magnetic nanotag Proc. Natl. Acad. Sci. U. S. A. 2008, 105 (52) 20637-20640 10.1073/pnas.0810822105
-
(2008)
Proc. Natl. Acad. Sci. U. S. A.
, vol.105
, Issue.52
, pp. 20637-20640
-
-
Osterfeld, S.J.1
Yu, H.2
Gaster, R.S.3
Caramuta, S.4
Xu, L.5
Han, S.J.6
Hall, D.A.7
Wilson, R.J.8
Sun, S.9
White, R.L.10
Davis, R.W.11
Pourmand, N.12
Wang, S.X.13
-
6
-
-
77953246142
-
Single-molecule enzyme-linked immunosorbent assay detects serum proteins at subfemtomolar concentrations
-
Rissin, D. M.; Kan, C. W.; Campbell, T. G.; Howes, S. C.; Fournier, D. R.; Song, L.; Piech, T.; Patel, P. P.; Chang, L.; Rivnak, A. J.; Ferrell, E. P.; Randall, J. D.; Provuncher, G. K.; Walt, D. R.; Duffy, D. C. Single-molecule enzyme-linked immunosorbent assay detects serum proteins at subfemtomolar concentrations Nat. Biotechnol. 2010, 28 (6) 595-599 10.1038/nbt.1641
-
(2010)
Nat. Biotechnol.
, vol.28
, Issue.6
, pp. 595-599
-
-
Rissin, D.M.1
Kan, C.W.2
Campbell, T.G.3
Howes, S.C.4
Fournier, D.R.5
Song, L.6
Piech, T.7
Patel, P.P.8
Chang, L.9
Rivnak, A.J.10
Ferrell, E.P.11
Randall, J.D.12
Provuncher, G.K.13
Walt, D.R.14
Duffy, D.C.15
-
7
-
-
0038290677
-
A whole blood immunoassay using gold nanoshells
-
Hirsch, L. R.; Jackson, J. B.; Lee, A.; Halas, N. J.; West, J. L. A whole blood immunoassay using gold nanoshells Anal. Chem. 2003, 75 (10) 2377-2381 10.1021/ac0262210
-
(2003)
Anal. Chem.
, vol.75
, Issue.10
, pp. 2377-2381
-
-
Hirsch, L.R.1
Jackson, J.B.2
Lee, A.3
Halas, N.J.4
West, J.L.5
-
8
-
-
72049107734
-
On-chip immuno-agglutination assay with analyte capture by dynamic manipulation on superparamagnetic beads
-
Moser, Y.; Lehnert, T.; Gijs, M. A. M. On-chip immuno-agglutination assay with analyte capture by dynamic manipulation on superparamagnetic beads Lab Chip 2009, 9 (22) 3261-3267 10.1039/b907724c
-
(2009)
Lab Chip
, vol.9
, Issue.22
, pp. 3261-3267
-
-
Moser, Y.1
Lehnert, T.2
Gijs, M.A.M.3
-
9
-
-
80053338577
-
Single particle technique for one-step homogeneous detection of cancer marker using gold nanoparticle probes
-
Lan, T.; Dong, C.; Huang, X.; Ren, J. Single particle technique for one-step homogeneous detection of cancer marker using gold nanoparticle probes Analyst 2011, 136 (20) 4247-4253 10.1039/c1an15497d
-
(2011)
Analyst
, vol.136
, Issue.20
, pp. 4247-4253
-
-
Lan, T.1
Dong, C.2
Huang, X.3
Ren, J.4
-
10
-
-
84860371249
-
Graphene-based chemiluminescence resonance energy transfer for homogeneous assay
-
Lee, J. S.; Joung, H. A.; Kim, M. G.; Park, C. B. Graphene-based chemiluminescence resonance energy transfer for homogeneous assay ACS Nano 2012, 6 (4) 2978-2983 10.1021/nn300684d
-
(2012)
ACS Nano
, vol.6
, Issue.4
, pp. 2978-2983
-
-
Lee, J.S.1
Joung, H.A.2
Kim, M.G.3
Park, C.B.4
-
11
-
-
84862782130
-
Multiplexed detection of tumor markers with multicolor quantum dots based on fluorescence polarization immunoassay
-
Tian, J.; Zhou, L.; Zhao, Y.; Yang, W.; Peng, Y.; Zhao, S. Multiplexed detection of tumor markers with multicolor quantum dots based on fluorescence polarization immunoassay Talanta 2012, 92, 72-77 10.1016/j.talanta.2012.01.051
-
(2012)
Talanta
, vol.92
, pp. 72-77
-
-
Tian, J.1
Zhou, L.2
Zhao, Y.3
Yang, W.4
Peng, Y.5
Zhao, S.6
-
12
-
-
72849130677
-
Rapid integrated biosensor for multiplexed immunoassays based on actuated magnetic nanoparticles
-
Bruls, T. M.; Evers, T. H.; Kahlman, J. A. H.; Van Lankvelt, P. J. W.; Ovsyanko, M.; Pelssers, E. G. M.; Schleipen, J. J. H. B.; De Theije, F. K.; Verschuren, C. A.; Van der Wijk, T.; van Zon, J. B. A.; Dittmer, W. U.; Immink, A. H. J.; Nieuwenhuis, J. H.; Prins, M. W. J. Rapid integrated biosensor for multiplexed immunoassays based on actuated magnetic nanoparticles Lab Chip 2009, 9 (24) 3504-3510 10.1039/b913960e
-
(2009)
Lab Chip
, vol.9
, Issue.24
, pp. 3504-3510
-
-
Bruls, T.M.1
Evers, T.H.2
Kahlman, J.A.H.3
Van Lankvelt, P.J.W.4
Ovsyanko, M.5
Pelssers, E.G.M.6
Schleipen, J.J.H.B.7
De Theije, F.K.8
Verschuren, C.A.9
Van Der Wijk, T.10
Van Zon, J.B.A.11
Dittmer, W.U.12
Immink, A.H.J.13
Nieuwenhuis, J.H.14
Prins, M.W.J.15
-
13
-
-
79957962523
-
Homogeneous fluorescence-based immunoassay detects antigens within 90 seconds
-
Kreisig, T.; Hoffmann, R.; Zuchner, T. Homogeneous fluorescence-based immunoassay detects antigens within 90 seconds Anal. Chem. 2011, 83 (11) 4281-4287 10.1021/ac200777h
-
(2011)
Anal. Chem.
, vol.83
, Issue.11
, pp. 4281-4287
-
-
Kreisig, T.1
Hoffmann, R.2
Zuchner, T.3
-
14
-
-
79955884077
-
Frequency-selective rotation of two-particle nanoactuators for rapid and sensitive detection of biomolecules
-
Ranzoni, A.; Schleipen, J. J. H. B.; van IJzendoorn, L. J.; Prins, M. W. J. Frequency-selective rotation of two-particle nanoactuators for rapid and sensitive detection of biomolecules Nano Lett. 2009, 9 (22) 2017-2022 10.1021/nl200384p
-
(2009)
Nano Lett.
, vol.9
, Issue.22
, pp. 2017-2022
-
-
Ranzoni, A.1
Schleipen, J.J.H.B.2
Van Ijzendoorn, L.J.3
Prins, M.W.J.4
-
15
-
-
84866996284
-
A Fast and Sensitive Quantitative Lateral Flow Immunoassay for Cry1Ab Based on a Novel Signal Amplification Conjugate
-
Chen, C.; Wu, J. A Fast and Sensitive Quantitative Lateral Flow Immunoassay for Cry1Ab Based on a Novel Signal Amplification Conjugate Sensors 2012, 12 (9) 11684-11696 10.3390/s120911684
-
(2012)
Sensors
, vol.12
, Issue.9
, pp. 11684-11696
-
-
Chen, C.1
Wu, J.2
-
16
-
-
84875867885
-
Vertical flow immunoassay (VFA) biosensor for a rapid one-step immunoassay
-
Oh, Y. K.; Joung, H. A.; Kim, S.; Kim, M. G. Vertical flow immunoassay (VFA) biosensor for a rapid one-step immunoassay Lab Chip 2013, 13 (5) 768-772 10.1039/c2lc41016h
-
(2013)
Lab Chip
, vol.13
, Issue.5
, pp. 768-772
-
-
Oh, Y.K.1
Joung, H.A.2
Kim, S.3
Kim, M.G.4
-
17
-
-
0031682733
-
Measuring two-dimensional receptor-ligand binding kinetics by micropipette
-
Chesla, S. E.; Selvaraj, P.; Zhu, C. Measuring two-dimensional receptor-ligand binding kinetics by micropipette Biophys. J. 1998, 75 (3) 1553-1572 10.1016/S0006-3495(98)74074-3
-
(1998)
Biophys. J.
, vol.75
, Issue.3
, pp. 1553-1572
-
-
Chesla, S.E.1
Selvaraj, P.2
Zhu, C.3
-
18
-
-
40449107402
-
Ligand-receptor interactions in chains of colloid: when reactions are limited by rotational diffusion
-
Lee, N. K.; Johner, A.; Thalmann, F.; Cohen-Tannoudji, L.; Bertrand, E.; Baudry, J.; Bibette, J.; Marques, C. M. Ligand-receptor interactions in chains of colloid: when reactions are limited by rotational diffusion Langmuir 2008, 24 (4) 1296-1307 10.1021/la701639n
-
(2008)
Langmuir
, vol.24
, Issue.4
, pp. 1296-1307
-
-
Lee, N.K.1
Johner, A.2
Thalmann, F.3
Cohen-Tannoudji, L.4
Bertrand, E.5
Baudry, J.6
Bibette, J.7
Marques, C.M.8
-
19
-
-
40849096135
-
Measuring the kinetics of biomolecular recognition with magnetic colloids
-
Cohen-Tannoudji, L.; Bertrand, E.; Baudry, J.; Robic, C.; Goubault, C.; Pellissier, M.; Johner, A.; Thalmann, F.; Lee, N. K.; Marques, C. M.; Bibette, J. Measuring the kinetics of biomolecular recognition with magnetic colloids Phys. Rev. Lett. 2008, 100 (10) 108301 10.1103/PhysRevLett.100.108301
-
(2008)
Phys. Rev. Lett.
, vol.100
, Issue.10
, pp. 108301
-
-
Cohen-Tannoudji, L.1
Bertrand, E.2
Baudry, J.3
Robic, C.4
Goubault, C.5
Pellissier, M.6
Johner, A.7
Thalmann, F.8
Lee, N.K.9
Marques, C.M.10
Bibette, J.11
-
20
-
-
84860358391
-
One-step homogeneous magnetic nanoparticle immunoassay for biomarker detection directly in blood plasma
-
Ranzoni, A.; Sabatte, G.; Van IJzendoorn, L. J.; Prins, M. W. J. One-step homogeneous magnetic nanoparticle immunoassay for biomarker detection directly in blood plasma ACS Nano 2012, 6 (4) 3134-3141 10.1021/nn204913f
-
(2012)
ACS Nano
, vol.6
, Issue.4
, pp. 3134-3141
-
-
Ranzoni, A.1
Sabatte, G.2
Van Ijzendoorn, L.J.3
Prins, M.W.J.4
-
21
-
-
84937968356
-
Optical protein detection based on magnetic clusters rotation
-
Ramiandrisoa, D.; Brient-Litzler, E.; Daynès, A.; Compain, E.; Bibette, J.; Baudry, J. Optical protein detection based on magnetic clusters rotation New Biotechnol. 2015, 32, 467 10.1016/j.nbt.2015.03.013
-
(2015)
New Biotechnol.
, vol.32
, pp. 467
-
-
Ramiandrisoa, D.1
Brient-Litzler, E.2
Daynès, A.3
Compain, E.4
Bibette, J.5
Baudry, J.6
-
22
-
-
60049100246
-
Measuring colloidal forces with the magnetic chaining technique
-
Dreyfus, R.; Lacoste, D.; Bibette, J.; Baudry, J. Measuring colloidal forces with the magnetic chaining technique Eur. Phys. J. E: Soft Matter Biol. Phys. 2009, 28 (2) 113-123 10.1140/epje/i2008-10414-4
-
(2009)
Eur. Phys. J. E: Soft Matter Biol. Phys.
, vol.28
, Issue.2
, pp. 113-123
-
-
Dreyfus, R.1
Lacoste, D.2
Bibette, J.3
Baudry, J.4
-
23
-
-
23044464822
-
Mathematical functions for the analysis of luminescence decays with underlying distributions 1. Kohlrausch decay function (stretched exponential)
-
Berberan-Santos, M. N.; Bodunov, E. N.; Valeur, B. Mathematical functions for the analysis of luminescence decays with underlying distributions 1. Kohlrausch decay function (stretched exponential) Chem. Phys. 2005, 315 (1) 171-182 10.1016/j.chemphys.2005.04.006
-
(2005)
Chem. Phys.
, vol.315
, Issue.1
, pp. 171-182
-
-
Berberan-Santos, M.N.1
Bodunov, E.N.2
Valeur, B.3
-
24
-
-
0347625841
-
Blood pressure, C-reactive protein, and risk of future cardiovascular events
-
Blake, G. J.; Rifai, N.; Buring, J. E.; Ridker, P. M. Blood pressure, C-reactive protein, and risk of future cardiovascular events Circulation 2003, 108 (24) 2993-2999 10.1161/01.CIR.0000104566.10178.AF
-
(2003)
Circulation
, vol.108
, Issue.24
, pp. 2993-2999
-
-
Blake, G.J.1
Rifai, N.2
Buring, J.E.3
Ridker, P.M.4
-
25
-
-
0032704217
-
The C-reactive protein
-
Clyne, B.; Olshaker, J. S. The C-reactive protein J. Emerg. Med. 1999, 17 (6) 1019-1025 10.1016/S0736-4679(99)00135-3
-
(1999)
J. Emerg. Med.
, vol.17
, Issue.6
, pp. 1019-1025
-
-
Clyne, B.1
Olshaker, J.S.2
|