메뉴 건너뛰기




Volumn 132, Issue 10, 2015, Pages 907-915

Randomized, Controlled Trial of the Safety and Effectiveness of a Contact Force-Sensing Irrigated Catheter for Ablation of Paroxysmal Atrial Fibrillation: Results of the TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASTAR) Study

Author keywords

ablation techniques; atrial fibrillation; catheter ablation

Indexed keywords

ANTIARRHYTHMIC AGENT;

EID: 84941343767     PISSN: 00097322     EISSN: 15244539     Source Type: Journal    
DOI: 10.1161/CIRCULATIONAHA.114.014092     Document Type: Article
Times cited : (327)

References (21)
  • 1
    • 84894163826 scopus 로고    scopus 로고
    • Radiofrequency ablation vs antiarrhythmic drugs as first-line treatment of paroxysmal atrial fibrillation (RAAFT-2): A randomized trial
    • RAAFT-2 Investigators
    • Morillo CA, Verma A, Connolly SJ, Kuck KH, Nair GM, Champagne J, Sterns LD, Beresh H, Healey JS, Natale A; RAAFT-2 Investigators. Radiofrequency Ablation vs Antiarrhythmic Drugs as First-Line Treatment of Paroxysmal Atrial Fibrillation (RAAFT-2): a randomized trial. JAMA. 2014;311:692-700. doi: 10.1001/jama.2014.467.
    • (2014) JAMA , vol.311 , pp. 692-700
    • Morillo, C.A.1    Verma, A.2    Connolly, S.J.3    Kuck, K.H.4    Nair, G.M.5    Champagne, J.6    Sterns, L.D.7    Beresh, H.8    Healey, J.S.9    Natale, A.10
  • 4
    • 84876283750 scopus 로고    scopus 로고
    • Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: First results of the North American Arctic Front (STOP AF) pivotal trial
    • STOP AF Cryoablation Investigators
    • Packer DL, Kowal RC, Wheelan KR, Irwin JM, Champagne J, Guerra PG, Dubuc M, Reddy V, Nelson L, Holcomb RG, Lehmann JW, Ruskin JN; STOP AF Cryoablation Investigators. Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front (STOP AF) pivotal trial. J Am Coll Cardiol. 2013;61:1713-1723. doi: 10.1016/j.jacc.2012.11.064.
    • (2013) J Am Coll Cardiol , vol.61 , pp. 1713-1723
    • Packer, D.L.1    Kowal, R.C.2    Wheelan, K.R.3    Irwin, J.M.4    Champagne, J.5    Guerra, P.G.6    Dubuc, M.7    Reddy, V.8    Nelson, L.9    Holcomb, R.G.10    Lehmann, J.W.11    Ruskin, J.N.12
  • 9
    • 0031436188 scopus 로고    scopus 로고
    • The effects of electrode-tissue contact on radiofrequency lesion generation
    • Avitall B, Mughal K, Hare J, Helms R, Krum D. The effects of electrode-tissue contact on radiofrequency lesion generation. Pacing Clin Electrophysiol. 1997;20(pt 1):2899-2910.
    • (1997) Pacing Clin Electrophysiol , vol.20 , pp. 2899-2910
    • Avitall, B.1    Mughal, K.2    Hare, J.3    Helms, R.4    Krum, D.5
  • 15
    • 77956323154 scopus 로고    scopus 로고
    • Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model
    • Shah DC, Lambert H, Nakagawa H, Langenkamp A, Aeby N, Leo G. Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model. J Cardiovasc Electrophysiol. 2010;21:1038-1043. doi: 10.1111/j.1540-8167.2010.01750.x.
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 1038-1043
    • Shah, D.C.1    Lambert, H.2    Nakagawa, H.3    Langenkamp, A.4    Aeby, N.5    Leo, G.6
  • 17
    • 77954052095 scopus 로고    scopus 로고
    • Importance of catheter contact force during irrigated radiofrequency ablation: Evaluation in a porcine ex vivo model using a force-sensing catheter
    • Thiagalingam A, D'Avila A, Foley L, Guerrero JL, Lambert H, Leo G, Ruskin JN, Reddy VY. Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter. J Cardiovasc Electrophysiol. 2010;21:806-811. doi: 10.1111/j.1540-8167.2009.01693.x.
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 806-811
    • Thiagalingam, A.1    D'Avila, A.2    Foley, L.3    Guerrero, J.L.4    Lambert, H.5    Leo, G.6    Ruskin, J.N.7    Reddy, V.Y.8
  • 21
    • 84925547575 scopus 로고    scopus 로고
    • Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: Electrode amplitude, impedance and electrode temperature are poor predictors of electrode-tissue contact force and lesion size
    • Nakagawa H, Ikeda A, Lambert H, Shah D, Fonck E, Yulzari A, Sharma T, Pitha J, Lazzara R, Jackman W. Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: electrode amplitude, impedance and electrode temperature are poor predictors of electrode-tissue contact force and lesion size. Circ Arrhythm Electrophysiol. 2014;7:1174-1180.
    • (2014) Circ Arrhythm Electrophysiol , vol.7 , pp. 1174-1180
    • Nakagawa, H.1    Ikeda, A.2    Lambert, H.3    Shah, D.4    Fonck, E.5    Yulzari, A.6    Sharma, T.7    Pitha, J.8    Lazzara, R.9    Jackman, W.10


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.