메뉴 건너뛰기




Volumn 6, Issue 2, 2013, Pages 327-333

Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: Results from the EFFICAS i study

Author keywords

Atrial fibrillation; Catheter ablation; Contact force; Gaps

Indexed keywords

ABLATION THERAPY; ADULT; AGED; ARTICLE; CATHETER ABLATION; CATHETER TIP SENSOR; CLINICAL ARTICLE; CONTACT FORCE; CONTROLLED STUDY; FEMALE; FOLLOW UP; FORCE; HEART ATRIUM FIBRILLATION; HEART CONDUCTION; HUMAN; MALE; MULTICENTER STUDY; OPERATOR; PERICARDIAL EFFUSION; PRIORITY JOURNAL; PULMONARY VEIN ISOLATION; RADIOFREQUENCY ABLATION; RADIOFREQUENCY ABLATION DEVICE; SINGLE BLIND PROCEDURE;

EID: 84878091264     PISSN: 19413149     EISSN: 19413084     Source Type: Journal    
DOI: 10.1161/CIRCEP.113.000374     Document Type: Article
Times cited : (393)

References (17)
  • 6
    • 38049161741 scopus 로고    scopus 로고
    • Radiofrequency ablation of atrial fibrillation: Is the persistence of all intraprocedural targets necessary for long-term maintenance of sinus rhythm?
    • Pratola C, Baldo E, Notarstefano P, Toselli T, Ferrari R. Radiofrequency ablation of atrial fibrillation: is the persistence of all intraprocedural targets necessary for long-term maintenance of sinus rhythm? Circulation. 2008;117:136-143.
    • (2008) Circulation , vol.117 , pp. 136-143
    • Pratola, C.1    Baldo, E.2    Notarstefano, P.3    Toselli, T.4    Ferrari, R.5
  • 9
    • 77954052095 scopus 로고    scopus 로고
    • Importance of catheter contact force during irrigated radiofrequency ablation: Evaluation in a porcine ex vivo model using a force-sensing catheter
    • Thiagalingam A, D'Avila A, Foley L, Guerrero JL, Lambert H, Leo G, Ruskin JN, Reddy VY. Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter. J Cardiovasc Electrophysiol. 2010;21: 806-811.
    • (2010) J Cardiovasc Electrophysiol. , vol.21 , pp. 806-811
    • Thiagalingam, A.1    D'Avila, A.2    Foley, L.3    Guerrero, J.L.4    Lambert, H.5    Leo, G.6    Ruskin, J.N.7    Reddy, V.Y.8
  • 10
    • 45149096795 scopus 로고    scopus 로고
    • A systematical analysis of in vivo contact forces on virtual catheter tip/tissue surface contact during cardiac mapping and intervention
    • Okumura Y, Johnson SB, Bunch TJ, Henz BD, O'Brien CJ, Packer DL. A systematical analysis of in vivo contact forces on virtual catheter tip/tissue surface contact during cardiac mapping and intervention. J Cardiovasc Electrophysiol. 2008;19:632-640.
    • (2008) J Cardiovasc Electrophysiol. , vol.19 , pp. 632-640
    • Okumura, Y.1    Johnson, S.B.2    Bunch, T.J.3    Henz, B.D.4    O'Brien, C.J.5    Packer, D.L.6
  • 11
    • 77956323154 scopus 로고    scopus 로고
    • Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model
    • Shah DC, Lambert H, Nakagawa H, Langenkamp A, Aeby N, Leo G. Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model. J Cardiovasc Electrophysiol. 2010;21:1038-1043.
    • (2010) J Cardiovasc Electrophysiol. , vol.21 , pp. 1038-1043
    • Shah, D.C.1    Lambert, H.2    Nakagawa, H.3    Langenkamp, A.4    Aeby, N.5    Leo, G.6
  • 14
    • 41949100939 scopus 로고    scopus 로고
    • Circumferential pulmonary vein isolation: The role of key target sites
    • Wang XH, Shi HF, Sun YM, Gu JN, Zhou L, Liu X. Circumferential pulmonary vein isolation: the role of key target sites. Europace. 2008;10:197-204.
    • (2008) Europace , vol.10 , pp. 197-204
    • Wang, X.H.1    Shi, H.F.2    Sun, Y.M.3    Gu, J.N.4    Zhou, L.5    Liu, X.6
  • 16
    • 0034795809 scopus 로고    scopus 로고
    • Changes in local wall thickness correlate with pathologic lesion size following radiofrequency catheter ablation: An intracardiac echocardiographic imaging study
    • Ren JF, Callans DJ, Schwartzman D, Michele JJ, Marchlinski FE. Changes in local wall thickness correlate with pathologic lesion size following radiofrequency catheter ablation: an intracardiac echocardiographic imaging study. Echocardiography. 2001;18:503-507.
    • (2001) Echocardiography , vol.18 , pp. 503-507
    • Ren, J.F.1    Callans, D.J.2    Schwartzman, D.3    Michele, J.J.4    Marchlinski, F.E.5
  • 17
    • 36249021084 scopus 로고    scopus 로고
    • Electrophysiologic and anatomic characterization of sites resistant to electrical isolation during circumferential pulmonary vein ablation for atrial fibrillation: A prospective study
    • Kistler PM, Ho SY, Rajappan K, Morper M, Harris S, Abrams D, Sporton SC, Schilling RJ. Electrophysiologic and anatomic characterization of sites resistant to electrical isolation during circumferential pulmonary vein ablation for atrial fibrillation: a prospective study. J Cardiovasc Electrophysiol. 2007;18:1282-1288.
    • (2007) J Cardiovasc Electrophysiol. , vol.18 , pp. 1282-1288
    • Kistler, P.M.1    Ho, S.Y.2    Rajappan, K.3    Morper, M.4    Harris, S.5    Abrams, D.6    Sporton, S.C.7    Schilling, R.J.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.