Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: Electrogram amplitude, impedance, and electrode temperature are poor predictors of electrode-tissue contact force and lesion size

Author keywords

Atrial fibrillation; Catheter ablation; Radiofrequency; Ventricular tachycardia

Indexed keywords

ABLATION CATHETER; ARTICLE; BIOSENSOR; ELECTRODE; ELECTROGRAPHY; FORCE; HEART BEAT; HEART INJURY; HEART LEFT VENTRICLE; HEART RIGHT VENTRICLE; IMPEDANCE; PRIORITY JOURNAL; RADIOFREQUENCY ABLATION; TEMPERATURE; TIME; ADVERSE EFFECTS; ANIMAL; ANIMAL MODEL; CATHETER ABLATION; DEVICES; DOG; HEART CATHETER; HEART FUNCTION TEST; HEART VENTRICLE; HEAT; MECHANICAL STRESS; NOISE; PATHOLOGY; PREDICTIVE VALUE; RISK FACTOR; SURGERY; THERMOGRAPHY; WATER VAPOR;

EID: 84925547575     PISSN: 19413149     EISSN: 19413084     Source Type: Journal    
DOI: 10.1161/CIRCEP.113.001094     Document Type: Article
Times cited : (200)

References (14)
  • 1
    • 0031436188 scopus 로고    scopus 로고
    • The effects of electrode- tissue contact on radiofrequency lesion generation
    • Avitall B, Mughal K, Hare J, Helms R, Krum D. The effects of electrode- tissue contact on radiofrequency lesion generation. PACE. 1997;20:2899-2910.
    • (1997) PACE , vol.20 , pp. 2899-2910
    • Avitall, B.1    Mughal, K.2    Hare, J.3    Helms, R.4    Krum, D.5
  • 2
    • 0026325244 scopus 로고
    • Determinants of lesion size during radiofrequency catheter ablation: The role of electrode-tissue contact force and duration of energy delivery
    • Haines DE. Determinants of lesion size during radiofrequency catheter ablation: the role of electrode-tissue contact force and duration of energy delivery. J Cardiovasc Electrophysiol. 1991;2:509-515.
    • (1991) J Cardiovasc Electrophysiol , vol.2 , pp. 509-515
    • Haines, D.E.1
  • 5
    • 0031770673 scopus 로고    scopus 로고
    • The LETRPrinciple: A novel method to assess electrode-tissue contact in radiofrequency ablation
    • Eick OJ, Wittkampf FH, Bronneberg T, Schumacher B. The LETRPrinciple: a novel method to assess electrode-tissue contact in radiofrequency ablation. J Cardiovasc Electrophysiol. 1998;9:1180-1185.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 1180-1185
    • Eick, O.J.1    Wittkampf, F.H.2    Bronneberg, T.3    Schumacher, B.4
  • 6
    • 33750682650 scopus 로고    scopus 로고
    • RF catheter ablation: Lessons on lesions
    • Wittkampf FH, Nakagawa H. RF catheter ablation: lessons on lesions. Pacing Clin Electrophysiol. 2006;29:1285-1297. doi: 10.1111/j.1540-8159.2006.00533.x.
    • (2006) Pacing Clin Electrophysiol , vol.29 , pp. 1285-1297
    • Wittkampf, F.H.1    Nakagawa, H.2
  • 9
    • 77956323154 scopus 로고    scopus 로고
    • Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model
    • Shah DC, Lambert H, Nakagawa H, Langenkamp A, Aeby N, Leo G. Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model. J Cardiovasc Electrophysiol. 2010;21:1038-1043. doi: 10.1111/j.1540-8167.2010.01750.x.
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 1038-1043
    • Shah, D.C.1    Lambert, H.2    Nakagawa, H.3    Langenkamp, A.4    Aeby, N.5    Leo, G.6
  • 10
    • 77954052095 scopus 로고    scopus 로고
    • Importance of catheter contact force during irrigated radiofrequency ablation: Evaluation in a porcine ex vivo model using a force-sensing catheter
    • Thiagalingam A, D'Avila A, Foley L, Guerrero JL, Lambert H, Leo G, Ruskin JN, Reddy VY. Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter. J Cardiovasc Electrophysiol. 2010;21:806-811. doi: 10.1111/j.1540-8167.2009.01693.x.
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 806-811
    • Thiagalingam, A.1    D'Avila, A.2    Foley, L.3    Guerrero, J.L.4    Lambert, H.5    Leo, G.6    Ruskin, J.N.7    Reddy, V.Y.8
  • 13
    • 79958821392 scopus 로고    scopus 로고
    • Assessment of catheter tip contact force resulting in cardiac perforation in swine atria using force sensing technology
    • Perna F, Heist EK, Danik SB, Barrett CD, Ruskin JN, Mansour M. Assessment of catheter tip contact force resulting in cardiac perforation in swine atria using force sensing technology. Circ Arrhythm Electrophysiol. 2011;4:218-224. doi: 10.1161/CIRCEP.110.959429.
    • (2011) Circ Arrhythm Electrophysiol , vol.4 , pp. 218-224
    • Perna, F.1    Heist, E.K.2    Danik, S.B.3    Barrett, C.D.4    Ruskin, J.N.5    Mansour, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.