-
1
-
-
84855291354
-
Detection of periodontal bone loss using cone beam CT and intraoral radiography
-
de Faria Vasconcelos K, Evangelista KM, Rodrigues CD, Estrela C, de Sousa TO, Silva MA. Detection of periodontal bone loss using cone beam CT and intraoral radiography. Dentomaxillofac Radiol 2012; 41: 64-9. doi: 10.1259/dmfr/13676777
-
(2012)
Dentomaxillofac Radiol
, vol.41
, pp. 64-69
-
-
De Faria Vasconcelos, K.1
Evangelista, K.M.2
Rodrigues, C.D.3
Estrela, C.4
De Sousa, T.O.5
Silva, M.A.6
-
2
-
-
33748518930
-
Accuracy of cone beam computed tomography for periodontal defect measurements
-
Misch KA, Yi ES, Sarment DP. Accuracy of cone beam computed tomography for periodontal defect measurements. J Periodontol 2006; 77: 1261-6. doi: 10.1902/jop.2006.050367
-
(2006)
J Periodontol
, vol.77
, pp. 1261-1266
-
-
Misch, K.A.1
Yi, E.S.2
Sarment, D.P.3
-
3
-
-
62649163779
-
Evaluation of high-resolution cone beam computed tomography in the detection of simulated interradicular bone lesions
-
Noujeim M, Prihoda T, Langlais R, Nummikoski P. Evaluation of high-resolution cone beam computed tomography in the detection of simulated interradicular bone lesions. Dentomaxillofac Radiol 2009; 38: 156-62. doi: 10.1259/dmfr/61676894
-
(2009)
Dentomaxillofac Radiol
, vol.38
, pp. 156-162
-
-
Noujeim, M.1
Prihoda, T.2
Langlais, R.3
Nummikoski, P.4
-
4
-
-
84899506062
-
Diagnostic applications of cone-beam CT for periodontal diseases
-
Aljehani YA. Diagnostic applications of cone-beam CT for periodontal diseases. Int J Dent 2014; 2014: 865079. doi: 10.1155/ 2014/865079.
-
(2014)
Int J Dent
, vol.2014
, pp. 865079
-
-
Aljehani, Y.A.1
-
5
-
-
52049120502
-
In vitro cone beam computed tomography imaging of periodontal bone
-
Mol A, Balasundaram A. In vitro cone beam computed tomography imaging of periodontal bone. Dentomaxillofac Radiol 2008; 37: 319-24. doi: 10.1259/dmfr/26475758
-
(2008)
Dentomaxillofac Radiol
, vol.37
, pp. 319-324
-
-
Mol, A.1
Balasundaram, A.2
-
6
-
-
77954357678
-
Accuracy assessment of three-dimensional surface reconstructions of teeth from cone beam computed tomography scans
-
Al-Rawi B, Hassan B, Vandenberge B, Jacobs R. Accuracy assessment of three-dimensional surface reconstructions of teeth from cone beam computed tomography scans. J Oral Rehabil 2010; 37: 352-8. doi: 10.1111/j.1365-2842.2010.02065.x
-
(2010)
J Oral Rehabil
, vol.37
, pp. 352-358
-
-
Al-Rawi, B.1
Hassan, B.2
Vandenberge, B.3
Jacobs, R.4
-
7
-
-
84887375136
-
In vitro comparison of cone beam computed tomography with different voxel sizes for detection of simulated external root resorption
-
Neves FS, de Freitas DQ, Campos PS, de Almeida SM, Haiter-Neto F. In vitro comparison of cone beam computed tomography with different voxel sizes for detection of simulated external root resorption. J Oral Sci 2012; 54: 219-25.
-
(2012)
J Oral Sci
, vol.54
, pp. 219-225
-
-
Neves, F.S.1
De Freitas, D.Q.2
Campos, P.S.3
De Almeida, S.M.4
Haiter-Neto, F.5
-
8
-
-
0029240902
-
Assessment of the dentate alveolar process with high resolution computed tomography
-
Fuhrmann RAW, Wehrbein H, Langen HJ, Diedrich PR. Assessment of the dentate alveolar process with high resolution computed tomography. Dentomaxillofac Radiol 1995; 24: 50-4. doi: 10.1259/dmfr.24.1.8593909
-
(1995)
Dentomaxillofac Radiol
, vol.24
, pp. 50-54
-
-
Raw, F.1
Wehrbein, H.2
Langen, H.J.3
Diedrich, P.R.4
-
9
-
-
34547960968
-
Diagnostic validity (or acuity) of 2D CCD versus 3D CBCT-images for assessing periodontal breakdown
-
Vandenberghe B, Jacobs R, Yang J. Diagnostic validity (or acuity) of 2D CCD versus 3D CBCT-images for assessing periodontal breakdown. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007; 104: 395-401. doi: 10.1016/j.tripleo.2007.03.012
-
(2007)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.104
, pp. 395-401
-
-
Vandenberghe, B.1
Jacobs, R.2
Yang, J.3
-
10
-
-
59649097468
-
Relationship between density variability and imaging volume size in cone-beam computerized tomographic scanning of the maxillofacial region: An in vitro study
-
Katsumata A, Hirukawa A, Okumura S, Naitoh M, Fujishita M, Ariji E, et al. Relationship between density variability and imaging volume size in cone-beam computerized tomographic scanning of the maxillofacial region: an in vitro study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107: 420-5. doi: 10.1016/j.tripleo.2008.05.049
-
(2009)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.107
, pp. 420-425
-
-
Katsumata, A.1
Hirukawa, A.2
Okumura, S.3
Naitoh, M.4
Fujishita, M.5
Ariji, E.6
-
11
-
-
33746041477
-
Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT
-
Ludlow JB, Davies-Ludlow LE, Brooks SL, Howerton WB. Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT. Dentomaxillofac Radiol 2006; 35: 219-26. doi: 10.1259/dmfr/14340323
-
(2006)
Dentomaxillofac Radiol
, vol.35
, pp. 219-226
-
-
Ludlow, J.B.1
Davies-Ludlow, L.E.2
Brooks, S.L.3
Howerton, W.B.4
-
12
-
-
53049104346
-
Image distortion and spatial resolution of a commercially available cone-beam computed tomography machine
-
Ballrick JW, Palomo JM, Ruch E, Amberman BD, Hans MG. Image distortion and spatial resolution of a commercially available cone-beam computed tomography machine. Am J Orthod Dentofacial Orthop 2008; 134: 573-82. doi: 10.1016/j.ajodo.2007.11.025
-
(2008)
Am J Orthod Dentofacial Orthop
, vol.134
, pp. 573-582
-
-
Ballrick, J.W.1
Palomo, J.M.2
Ruch, E.3
Amberman, B.D.4
Hans, M.G.5
-
13
-
-
84880159916
-
Impact of voxel size variation on CBCT-based diagnostic outcome in dentistry: A systematic review
-
Spin-Neto R, Gotfredsen E, Wenzel A. Impact of voxel size variation on CBCT-based diagnostic outcome in dentistry: a systematic review. J Digit Imaging 2012; 26: 813-20. doi: 10.1007/ s10278-012-9562-7
-
(2012)
J Digit Imaging
, vol.26
, pp. 813-820
-
-
Spin-Neto, R.1
Gotfredsen, E.2
Wenzel, A.3
-
14
-
-
84941011400
-
CBCT-based volume of simulated root resorption-influence of FOV and voxel size
-
Oct. Epub ahead of print
-
Da Silveira PF, Fontana MP, Oliveira HW, Vizzotto MB, Montagner F, Silveira HL, et al. CBCT-based volume of simulated root resorption-influence of FOV and voxel size. Int Endod J Oct 2014. Epub ahead of print. doi: 10.1111/iej.12390
-
(2014)
Int Endod J
-
-
Da Silveira, P.F.1
Fontana, M.P.2
Oliveira, H.W.3
Vizzotto, M.B.4
Montagner, F.5
Silveira, H.L.6
-
17
-
-
38949161444
-
Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions
-
Haiter-Neto F, Wenzel A, Gotfredsen E. Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions. Dentomaxillofac Radiol 2008; 37: 18-22. doi: 10.1259/dmfr/87103878
-
(2008)
Dentomaxillofac Radiol
, vol.37
, pp. 18-22
-
-
Haiter-Neto, F.1
Wenzel, A.2
Gotfredsen, E.3
-
18
-
-
78049344799
-
Operational principles for cone-beam computed tomography
-
Hatcher DC. Operational principles for cone-beam computed tomography. J Am Dent Assoc 2010; 141: 3S-6S. doi: 10.14219/ jada.archive.2010.0359
-
(2010)
J Am Dent Assoc
, vol.141
, pp. 3S-6S
-
-
Hatcher, D.C.1
-
19
-
-
84864022337
-
Maxillofacial cone beam computed tomography: Essence, elements and steps to interpretation
-
Scarfe WC, Li Z, Aboelmaaty W, Scott SA, Farman AG. Maxillofacial cone beam computed tomography: essence, elements and steps to interpretation. Aust Dent J 2012; 57: 46-60. doi: 10.1111/ j.1834-7819.2011.01657.x
-
(2012)
Aust Dent J
, vol.57
, pp. 46-60
-
-
Scarfe, W.C.1
Li, Z.2
Aboelmaaty, W.3
Scott, S.A.4
Farman, A.G.5
-
20
-
-
71849103328
-
Variable-resolution cone beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model
-
Wenzel A, Haiter-Neto F, Frydenberg M, Kirkevang LL. Variable-resolution cone beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 939-45. doi: 10.1016/j. tripleo.2009.07.041
-
(2009)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.108
, pp. 939-945
-
-
Wenzel, A.1
Haiter-Neto, F.2
Frydenberg, M.3
Kirkevang, L.L.4
-
21
-
-
77957987539
-
Diagnostic ability of a cone-beam computed tomography scan to assess longitudinal root fractures in prosthetically treated teeth
-
Melo SL, Bortoluzzi EA, Abreu M Jr, Corrëa LR, Corrëa M. Diagnostic ability of a cone-beam computed tomography scan to assess longitudinal root fractures in prosthetically treated teeth. J Endod 2010; 36: 1879-82. doi: 10.1016/j.joen.2010.08.025
-
(2010)
J Endod
, vol.36
, pp. 1879-1882
-
-
Melo, S.L.1
Bortoluzzi, E.A.2
Abreu, M.3
Corrëa, L.R.4
Corrëa, M.5
-
22
-
-
84871968878
-
Detection of vertical root fractures by conventional radiographic examination and cone beam computed tomography-An in vitro analysis
-
da Silveira PF, Vizzotto MB, Liedke GS, da Silveira HL, Montagner F, da Silveira HE. Detection of vertical root fractures by conventional radiographic examination and cone beam computed tomography-An in vitro analysis. Dent Traumatol 2013; 29: 41-6. doi: 10.1111/j.1600-9657.2012.01126.x
-
(2013)
Dent Traumatol
, vol.29
, pp. 41-46
-
-
Da Silveira, P.F.1
Vizzotto, M.B.2
Liedke, G.S.3
Da Silveira, H.L.4
Montagner, F.5
Da Silveira, H.E.6
-
23
-
-
78650172132
-
Detection of vertical root fractures by using cone beam computed tomography with variable voxel sizes in an in vitro model
-
Özer SY. Detection of vertical root fractures by using cone beam computed tomography with variable voxel sizes in an in vitro model. J Endod 2011; 37: 75-9. doi: 10.1016/j.joen.2010.04.021
-
(2011)
J Endod
, vol.37
, pp. 75-79
-
-
Özer, S.Y.1
-
24
-
-
58249105408
-
Influence of voxel size in the diagnostic ability of cone beam tomography to evaluate simulated external root resorption
-
Liedke GS, da Silveira HE, da Silveira HL, Dutra V, de Figueiredo JA. Influence of voxel size in the diagnostic ability of cone beam tomography to evaluate simulated external root resorption. J Endod 2009; 35: 233-5. doi: 10.1016/j.joen.2008.11.005
-
(2009)
J Endod
, vol.35
, pp. 233-235
-
-
Liedke, G.S.1
Da Silveira, H.E.2
Da Silveira, H.L.3
Dutra, V.4
De Figueiredo, J.A.5
-
25
-
-
84865149154
-
Diagnostic value of two modes of cone-beam computed tomography in evaluation of simulated external root resorption: An in vitro study
-
Dalili Z, Taramsari M, Mousavi Mehr SZ, Salamat F. Diagnostic value of two modes of cone-beam computed tomography in evaluation of simulated external root resorption: an in vitro study. Imaging Sci Dent 2012; 42: 19-24. doi: 10.5624/isd.2012.42.1.19
-
(2012)
Imaging Sci Dent
, vol.42
, pp. 19-24
-
-
Dalili, Z.1
Taramsari, M.2
Mousavi Mehr, S.Z.3
Salamat, F.4
-
26
-
-
77955379961
-
A comparison of the diagnostic accuracy of CBCT images of different voxel resolutions used to detect simulated small internal resorption cavities
-
Kamburǒglu K, Kursun S. A comparison of the diagnostic accuracy of CBCT images of different voxel resolutions used to detect simulated small internal resorption cavities. Int Endod J 2010; 43: 798-807. doi: 10.1111/j.1365-2591.2010.01749.x
-
(2010)
Int Endod J
, vol.43
, pp. 798-807
-
-
Kamburǒglu, K.1
Kursun, S.2
-
27
-
-
77951014892
-
Occlusal caries detection by using a cone-beam CT with different voxel resolutions and a digital intraoral sensor
-
Kamburǒglu K, Murat S, Yüksel SP, Cebeci AR, Paksoy CS. Occlusal caries detection by using a cone-beam CT with different voxel resolutions and a digital intraoral sensor. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: e63-9. doi: 10.1016/j.tripleo.2009.12.048
-
(2010)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.109
, pp. e63-e69
-
-
Kamburǒglu, K.1
Murat, S.2
Yüksel, S.P.3
Cebeci, A.R.4
Paksoy, C.S.5
-
28
-
-
79959969200
-
Cone-beam computed tomography to detect erosions of the temporomandibular joint: Effect of field of view and voxel size on diagnostic efficacy and effective dose
-
Librizzi ZT, Tadinada AS, Valiyaparambil JV, Lurie AG, Mallya SM: Cone-beam computed tomography to detect erosions of the temporomandibular joint: effect of field of view and voxel size on diagnostic efficacy and effective dose. Am J Orthod Dentofacial Orthop 2011; 140: e25-30. doi: 10.1016/j.ajodo.2011.03.012
-
(2011)
Am J Orthod Dentofacial Orthop
, vol.140
, pp. e25-30
-
-
Librizzi, Z.T.1
Tadinada, A.S.2
Valiyaparambil, J.V.3
Lurie, A.G.4
Mallya, S.M.5
-
29
-
-
79551714811
-
Effect of bone thickness on alveolar bone-height measurements from conebeam computed tomography images
-
Sun Z, Smith T, Kortam S, Kim DG, Tee BC, Fields H. Effect of bone thickness on alveolar bone-height measurements from conebeam computed tomography images. Am J Orthod Dentofacial Orthop 2011; 139: 117-27. doi: 10.1016/j.ajodo.2010.08.016
-
(2011)
Am J Orthod Dentofacial Orthop
, vol.139
, pp. 117-127
-
-
Sun, Z.1
Smith, T.2
Kortam, S.3
Kim, D.G.4
Tee, B.C.5
Fields, H.6
-
30
-
-
84555177737
-
Accuracy of cone-beam computed tomography at different resolutions assessed on the bony covering of the mandibular anterior teeth
-
Patcas R,Müller L, Ullrich O, Peltomäki T. Accuracy of cone-beam computed tomography at different resolutions assessed on the bony covering of the mandibular anterior teeth. Am J Orthod Dentofacial Orthop 2012; 141: 41-50. doi: 10.1016/j.ajodo.2011.06.034
-
(2012)
Am J Orthod Dentofacial Orthop
, vol.141
, pp. 41-50
-
-
Patcas, R.1
Müller, L.2
Ullrich, O.3
Peltomäki, T.4
-
31
-
-
84859162468
-
Accuracy of linear measurements in cone beam computed tomography with different voxel sizes
-
Torres MG, Campos PS, Segundo NP, Navarro M, Crusoé-Rebello I. Accuracy of linear measurements in cone beam computed tomography with different voxel sizes. Implant Dent 2012; 21: 150-5. doi: 10.1097/ID.0b013e31824bf93c
-
(2012)
Implant Dent
, vol.21
, pp. 150-155
-
-
Torres, M.G.1
Campos, P.S.2
Segundo, N.P.3
Navarro, M.4
Crusoé-Rebello, I.5
-
32
-
-
77950345598
-
Accuracy and reliability of tooth and root lengths measured on cone-beam computed tomographs
-
Sherrard JF, Rossouw PE, Benson BW, Carrillo R, Buschang PH. Accuracy and reliability of tooth and root lengths measured on cone-beam computed tomographs. Am J Orthod Dentofacial Orthop 2010; 137: 100-8. doi: 10.1016/j.ajodo.2009.03.040
-
(2010)
Am J Orthod Dentofacial Orthop
, vol.137
, pp. 100-108
-
-
Sherrard, J.F.1
Rossouw, P.E.2
Benson, B.W.3
Carrillo, R.4
Buschang, P.H.5
-
33
-
-
72649103006
-
Accuracy of linear measurements from cone-beam computed tomography-derived surface models of different voxel sizes
-
Damstra J, Fourie Z, Huddleston Slater JJ, Ren Y. Accuracy of linear measurements from cone-beam computed tomography-derived surface models of different voxel sizes. Am J Orthod Dentofacial Orthop 2010; 137: 16.e1-16. doi: 10.1016/j.ajodo.2009.06.016
-
(2010)
Am J Orthod Dentofacial Orthop
, vol.137
, pp. 16e1-16e6
-
-
Damstra, J.1
Fourie, Z.2
Huddleston Slater, J.J.3
Ren, Y.4
-
34
-
-
84870887213
-
Detection of periimplant fenestration and dehiscence with the use of two scan modes and the smallest voxel sizes of a cone-beam computed tomography device
-
de-Azevedo-Vaz SL, Vasconcelos Kde F, Neves FS, Melo SL, Campos PS, Haiter-Neto F. Detection of periimplant fenestration and dehiscence with the use of two scan modes and the smallest voxel sizes of a cone-beam computed tomography device. Oral Surg Oral Med Oral Pathol Oral Radiol 2013; 115: 121-7. doi: 10.1016/j.oooo.2012.10.003
-
(2013)
Oral Surg Oral Med Oral Pathol Oral Radiol
, vol.115
, pp. 121-127
-
-
De-Azevedo-Vaz, S.L.1
Vasconcelos Kde, F.2
Neves, F.S.3
Melo, S.L.4
Campos, P.S.5
Haiter-Neto, F.6
|