메뉴 건너뛰기




Volumn 41, Issue 1, 2012, Pages 64-69

Detection of periodontal bone loss using cone beam CT and intraoral radiography

Author keywords

Alveolar bone loss; Diagnosis; Radiology; Tomography

Indexed keywords

ADULT; AGED; ALVEOLAR BONE LOSS; ANATOMY; ARTICLE; CEPHALOMETRY; COMPARATIVE STUDY; CONE BEAM COMPUTED TOMOGRAPHY; CROSS-SECTIONAL STUDY; FEMALE; HUMAN; IMAGE PROCESSING; JAW; MALE; METHODOLOGY; MIDDLE AGED; RADIOGRAPHY; TOOTH CERVIX; TOOTH RADIOGRAPHY;

EID: 84855291354     PISSN: 0250832X     EISSN: None     Source Type: Journal    
DOI: 10.1259/dmfr/13676777     Document Type: Article
Times cited : (107)

References (27)
  • 1
    • 0029162111 scopus 로고
    • Diagnosis of infra-alveolar bony lesions in the dentate alveolar process with high-resolution computed tomography: Experimental results
    • Langen HJ, Fuhrmann R, Diedrich P, Gunther RW. Diagnosis of infra-alveolar bony lesions in the dentate alveolar process with high-resolution computed tomography: experimental results. Invest Radiol 1995; 30: 421-426.
    • (1995) Invest Radiol , vol.30 , pp. 421-426
    • Langen, H.J.1    Fuhrmann, R.2    Diedrich, P.3    Gunther, R.W.4
  • 2
    • 0028489629 scopus 로고
    • Current concepts in periodontal disease testing
    • Jeffcoat MK. Current concepts in periodontal disease testing. J Am Dent Assoc 1994; 125: 1071-1078.
    • (1994) J Am Dent Assoc , vol.125 , pp. 1071-1078
    • Jeffcoat, M.K.1
  • 3
    • 0027012574 scopus 로고
    • Radiographic methods in the evaluation of periodontal therapy
    • Reddy MS. Radiographic methods in the evaluation of periodontal therapy. J Periodontol 1992; 63: 1078-1084.
    • (1992) J Periodontol , vol.63 , pp. 1078-1084
    • Reddy, M.S.1
  • 5
    • 0026844631 scopus 로고
    • Radiographic methods for the detection of progressive alveolar bone loss
    • Jeffcoat MK. Radiographic methods for the detection of progressive alveolar bone loss. J Periodontol 1992; 63: 367-372.
    • (1992) J Periodontol , vol.63 , pp. 367-372
    • Jeffcoat, M.K.1
  • 6
    • 0022799361 scopus 로고
    • Radiographic quantification of alveolar bone level changes. Comparison of 3 currently used methods
    • Albandar JM, Abbas DK. Radiographic quantification of alveolar bone level changes. Comparison of 3 currently used methods. J Clin Periodontol 1986; 13: 810-813.
    • (1986) J Clin Periodontol , vol.13 , pp. 810-813
    • Albandar, J.M.1    Abbas, D.K.2
  • 7
    • 1542402171 scopus 로고    scopus 로고
    • Imaging methods in periodontology
    • DOI 10.1046/j.0906-6713.2003.003423.x
    • Mol A. Imaging methods in periodontology. Periodontology 2004; 34: 34-48. (Pubitemid 41794528)
    • (2004) Periodontology 2000 , vol.34 , pp. 34-48
    • Mol, A.1
  • 9
    • 33748518930 scopus 로고    scopus 로고
    • Accuracy of cone beam computed tomography for periodontal defect measurements
    • DOI 10.1902/jop.2006.050367
    • Misch KA, Yi ES, Sarment DP. Accuracy of cone beam computed tomography for periodontal defect measurements. J Periodontol 2006; 77: 1261-1266. (Pubitemid 44725035)
    • (2006) Journal of Periodontology , vol.77 , Issue.7 , pp. 1261-1266
    • Misch, K.A.1    Yi, E.S.2    Sarment, D.P.3
  • 11
    • 34547960968 scopus 로고    scopus 로고
    • Diagnostic validity (or acuity) of 2D CCD versus 3D CBCT images for assessing periodontal breakdown
    • Vandenberghe B, Jacobs R, Yang J. Diagnostic validity (or acuity) of 2D CCD versus 3D CBCT images for assessing periodontal breakdown. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007; 104: 395-401.
    • (2007) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.104 , pp. 395-401
    • Vandenberghe, B.1    Jacobs, R.2    Yang, J.3
  • 12
    • 20744434589 scopus 로고    scopus 로고
    • Digital volume tomography in the diagnosis of periodontal defects: An in vitro study on native pig and human mandibles
    • DOI 10.1902/jop.2005.76.5.665
    • Mengel R, Candir M, Shiratori K, Flores-De-Jacoby L. Digital volume tomography in the diagnosis of periodontal defects: an in vitro study of native pigs and human mandibles. J Periodontol 2005; 76: 665-673. (Pubitemid 40852376)
    • (2005) Journal of Periodontology , vol.76 , Issue.5 , pp. 665-673
    • Mengel, R.1    Candir, M.2    Shiratori, K.3    Flores-de-Jacoby, L.4
  • 13
    • 0001589876 scopus 로고
    • The intrabony pocket: Classification and treatment
    • Goldman HM, Cohen DW. The intrabony pocket: classification and treatment. J Periodontol 1957; 29: 272-279.
    • (1957) J Periodontol , vol.29 , pp. 272-279
    • Goldman, H.M.1    Cohen, D.W.2
  • 14
    • 34347354141 scopus 로고    scopus 로고
    • Radiographic study of ethnic variation in alveolar bone height among New Zealand dental students
    • Wong BKJ, Leichter JW, Chandler NP, Cullinan MP, Holborow DW. Radiographic study of ethnic variation in alveolar bone height among New Zealand dental students. J Periodontol 2007; 78: 1070-1074.
    • (2007) J Periodontol , vol.78 , pp. 1070-1074
    • Wong, B.K.J.1    Leichter, J.W.2    Chandler, N.P.3    Cullinan, M.P.4    Holborow, D.W.5
  • 15
    • 0016357403 scopus 로고
    • Prevalence and distribution of alveolar bone loss in a population of 15-year-old school children
    • Lennon MA, Davies RM. Prevalence and distribution of alveolar bone loss in a population of 15-year-old school children. J Clin Periodontol 1974; 1: 175-182.
    • (1974) J Clin Periodontol , vol.1 , pp. 175-182
    • Lennon, M.A.1    Davies, R.M.2
  • 16
    • 0020632262 scopus 로고
    • A radiographic study of chronic periodontitis in 15 year old Queensland children
    • Latcham NL, Powell RN, Jago JD, Seymour GJ, Aikten JF. A radiographic study of chronic periodontitis in 15-year-old Queensland children. J Clin Periodontol 1983; 10: 37-45. (Pubitemid 13114342)
    • (1983) Journal of Clinical Periodontology , vol.10 , Issue.1 , pp. 37-45
    • Latcham, N.L.1    Powell, R.N.2    Jago, J.D.3
  • 17
    • 0000171086 scopus 로고
    • Dimensions and relations of the dentogingival junctions in humans
    • Gargiulo AW, Wentz FM, Orban B. Dimensions and relations of the dentogingival junctions in humans. J Periodontol 1961; 32: 261-267.
    • (1961) J Periodontol , vol.32 , pp. 261-267
    • Gargiulo, A.W.1    Wentz, F.M.2    Orban, B.3
  • 18
    • 0032016339 scopus 로고    scopus 로고
    • Horizontal Alveolar Bone Loss and Vertical Bone Defects in an Adult Patient Population
    • Persson RE, Hollender LG, Laurell L, Persson GR. Horizontal alveolar bone loss and vertical bone defects in an adult patient population. J Periodontol 1998; 69: 348-356. (Pubitemid 128531937)
    • (1998) Journal of Periodontology , vol.69 , Issue.3 , pp. 348-356
    • Persson, R.E.1    Hollender, L.G.2    Laurell, L.3    Persson, G.R.4
  • 19
    • 58349085362 scopus 로고    scopus 로고
    • Comparison of clinical, periapical radiograph, and cone-beam volume tomography measurement techniques for assessing bone level changes following regenerative periodontal therapy
    • Grimard BA, Hoidal MJ, Mills MP, Mellonig JT, Nummikoski PV, Mealey BL. Comparison of clinical, periapical radiograph, and cone-beam volume tomography measurement techniques for assessing bone level changes following regenerative periodontal therapy. J Periodontol 2009; 80: 48-55.
    • (2009) J Periodontol , vol.80 , pp. 48-55
    • Grimard, B.A.1    Hoidal, M.J.2    Mills, M.P.3    Mellonig, J.T.4    Nummikoski, P.V.5    Mealey, B.L.6
  • 20
    • 0028490895 scopus 로고
    • Effective dose and risk assessment from film tomography used for dental implants
    • Frederiksen NL, Benson BW, Sokolowski TW. Effective dose and risk assessment from film tomography used for dental implants. Radiol 1994; 23: 123-127.
    • (1994) Radiol , vol.23 , pp. 123-127
    • Frederiksen, N.L.1    Benson, B.W.2    Sokolowski, T.W.3
  • 22
    • 24944525218 scopus 로고    scopus 로고
    • Two- and three-dimensional orthodontic imaging using limited cone beam-computed tomography
    • Nakajima A, Sameshima GT, Yoshinori A, Homme Y, Shimizu N, Dougherty H. Two and three-dimensional orthodontic imaging using limited cone beam - computed tomography. Angle Orthod 2005; 75: 895-903. (Pubitemid 43127373)
    • (2005) Angle Orthodontist , vol.75 , Issue.6 , pp. 895-903
    • Nakajima, A.1    Sameshima, G.T.2    Arai, Y.3    Homme, Y.4    Shimizu, N.5    Dougherty Sr., H.6
  • 23
    • 7944227238 scopus 로고    scopus 로고
    • Radiographic examination of the temporomandibular joint using cone beam computed tomography
    • Tsiklakis K, Syriopoulos K, Stamatakis HC. Radiographic examination of the temporomandibular joint using cone beam computed tomography. Dentomaxillofac Radiol 2004; 33: 196-201.
    • (2004) Dentomaxillofac Radiol , vol.33 , pp. 196-201
    • Tsiklakis, K.1    Syriopoulos, K.2    Stamatakis, H.C.3
  • 24
    • 33645731806 scopus 로고    scopus 로고
    • Cone-beam computed tomography in orthodontics: Benefits and limitations
    • Holberg C, Steinhauser S, Geis P, Janson-Rudzki I. Cone-beam computed tomography in orthodontics: benefits and limitations. J Orofac Orthop 2005; 66: 434-444.
    • (2005) J Orofac Orthop , vol.66 , pp. 434-444
    • Holberg, C.1    Steinhauser, S.2    Geis, P.3    Janson-Rudzki, I.4
  • 25
    • 59649097468 scopus 로고    scopus 로고
    • Relationship between density variability and imaging volume size in cone-beam computerized tomographic scanning of the maxillofacial region: An in vitro study
    • Katsumata A, Hirukawa A, Okumura S, Naitoh M, Fujishita M, Ariji E, et al. Relationship between density variability and imaging volume size in cone-beam computerized tomographic scanning of the maxillofacial region: an in vitro study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107: 420-425.
    • (2009) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.107 , pp. 420-425
    • Katsumata, A.1    Hirukawa, A.2    Okumura, S.3    Naitoh, M.4    Fujishita, M.5    Ariji, E.6
  • 26
    • 33746041477 scopus 로고    scopus 로고
    • Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT
    • DOI 10.1259/dmfr/14340323
    • Ludlow JB, Davies-Ludlow LE, Brooks SL, Howerton WB. Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT. Dentomaxillofac Radiol 2006; 35: 219-226. (Pubitemid 44076876)
    • (2006) Dentomaxillofacial Radiology , vol.35 , Issue.4 , pp. 219-226
    • Ludlow, J.B.1    Davies-Ludlow, L.E.2    Brooks, S.L.3    Howerton, W.B.4
  • 27
    • 53049104346 scopus 로고    scopus 로고
    • Image distortion and spatial resolution of a commercially available cone-beam computed tomography machine
    • Ballrick JW, Palomo JM, Ruch E, Amberman BD, Hans MG. Image distortion and spatial resolution of a commercially available cone-beam computed tomography machine. Am J Orthod Dentofacial Orthop 2008; 134: 573-582.
    • (2008) Am J Orthod Dentofacial Orthop , vol.134 , pp. 573-582
    • Ballrick, J.W.1    Palomo, J.M.2    Ruch, E.3    Amberman, B.D.4    Hans, M.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.