메뉴 건너뛰기




Volumn 28, Issue 2, 2015, Pages 103-118

Volumetric velocity measurements in restricted geometries using spiral sampling: a phantom study

Author keywords

4D flow; Blood flow quantification; Peak pressure gradient; Peak velocity; Phase contrast; Spiral encoding; Stenosis

Indexed keywords

ALGORITHM; ARTERY; BLOOD FLOW VELOCITY; BLOOD VOLUME; COMPUTER ASSISTED DIAGNOSIS; DEVICES; HUMAN; IMAGE ENHANCEMENT; IMAGE QUALITY; MAGNETIC RESONANCE ANGIOGRAPHY; PATHOLOGY; PATHOPHYSIOLOGY; PERIPHERAL OCCLUSIVE ARTERY DISEASE; PROCEDURES; REPRODUCIBILITY; SAMPLE SIZE; SENSITIVITY AND SPECIFICITY;

EID: 84938900436     PISSN: 09685243     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10334-014-0449-0     Document Type: Article
Times cited : (2)

References (56)
  • 1
    • 0345035202 scopus 로고    scopus 로고
    • Magnetic resonance imaging of valvular heart disease
    • COI: 1:STN:280:DC%2BD3c%2FhvVSmsQ%3D%3D, PID: 10548771
    • Sondergaard L, Stahlberg F, Thomsen C (1999) Magnetic resonance imaging of valvular heart disease. J Magn Reson Imaging 10(5):627–638
    • (1999) J Magn Reson Imaging , vol.10 , Issue.5 , pp. 627-638
    • Sondergaard, L.1    Stahlberg, F.2    Thomsen, C.3
  • 2
    • 0020677838 scopus 로고
    • Noninvasive prediction of transvalvular pressure gradient in patients with pulmonary stenosis by quantitative two-dimensional echocardiographic Doppler studies
    • COI: 1:STN:280:DyaL3s7ivF2jsw%3D%3D, PID: 6825241
    • Lima CO, Sahn DJ, Valdes-Cruz LM, Goldberg SJ, Barron JV, Allen HD, Grenadier E (1983) Noninvasive prediction of transvalvular pressure gradient in patients with pulmonary stenosis by quantitative two-dimensional echocardiographic Doppler studies. Circulation 67(4):866–871
    • (1983) Circulation , vol.67 , Issue.4 , pp. 866-871
    • Lima, C.O.1    Sahn, D.J.2    Valdes-Cruz, L.M.3    Goldberg, S.J.4    Barron, J.V.5    Allen, H.D.6    Grenadier, E.7
  • 3
    • 0017811669 scopus 로고
    • Noninvasive assessment of pressure drop in mitral stenosis by Doppler ultrasound
    • COI: 1:STN:280:DyaE1c7ksVGjtg%3D%3D, PID: 637964
    • Hatle L, Brubakk A, Tromsdal A, Angelsen B (1978) Noninvasive assessment of pressure drop in mitral stenosis by Doppler ultrasound. Br Heart J 40(2):131–140
    • (1978) Br Heart J , vol.40 , Issue.2 , pp. 131-140
    • Hatle, L.1    Brubakk, A.2    Tromsdal, A.3    Angelsen, B.4
  • 4
    • 0036481560 scopus 로고    scopus 로고
    • Recommendations for quantification of Doppler echocardiography: a report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography
    • PID: 11836492
    • Quinones MA, Otto CM, Stoddard M, Waggoner A, Zoghbi WA (2002) Recommendations for quantification of Doppler echocardiography: a report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. J Am Soc Echocardiogr 15(2):167–184
    • (2002) J Am Soc Echocardiogr , vol.15 , Issue.2 , pp. 167-184
    • Quinones, M.A.1    Otto, C.M.2    Stoddard, M.3    Waggoner, A.4    Zoghbi, W.A.5
  • 5
    • 33646907966 scopus 로고    scopus 로고
    • Valvular aortic stenosis: disease severity and timing of intervention
    • PID: 16750677
    • Otto CM (2006) Valvular aortic stenosis: disease severity and timing of intervention. J Am Coll Cardiol 47(11):2141–2151
    • (2006) J Am Coll Cardiol , vol.47 , Issue.11 , pp. 2141-2151
    • Otto, C.M.1
  • 6
    • 79955785234 scopus 로고    scopus 로고
    • Inaccuracy of Doppler echocardiographic estimates of pulmonary artery pressures in patients with pulmonary hypertension: implications for clinical practice
    • PID: 20864617
    • Rich JD, Shah SJ, Swamy RS, Kamp A, Rich S (2011) Inaccuracy of Doppler echocardiographic estimates of pulmonary artery pressures in patients with pulmonary hypertension: implications for clinical practice. Chest 139(5):988–993
    • (2011) Chest , vol.139 , Issue.5 , pp. 988-993
    • Rich, J.D.1    Shah, S.J.2    Swamy, R.S.3    Kamp, A.4    Rich, S.5
  • 7
    • 60549090789 scopus 로고    scopus 로고
    • Cardiovascular magnetic resonance imaging for valvular heart disease: technique and validation
    • PID: 19171869
    • Cawley PJ, Maki JH, Otto CM (2009) Cardiovascular magnetic resonance imaging for valvular heart disease: technique and validation. Circulation 119(3):468–478
    • (2009) Circulation , vol.119 , Issue.3 , pp. 468-478
    • Cawley, P.J.1    Maki, J.H.2    Otto, C.M.3
  • 8
    • 0027423487 scopus 로고
    • Magnetic resonance volume flow and jet velocity mapping in aortic coarctation
    • COI: 1:STN:280:DyaK2c%2FksValtg%3D%3D, PID: 8227813
    • Mohiaddin RH, Kilner PJ, Rees S, Longmore DB (1993) Magnetic resonance volume flow and jet velocity mapping in aortic coarctation. J Am Coll Cardiol 22(5):1515–1521
    • (1993) J Am Coll Cardiol , vol.22 , Issue.5 , pp. 1515-1521
    • Mohiaddin, R.H.1    Kilner, P.J.2    Rees, S.3    Longmore, D.B.4
  • 9
    • 0027568362 scopus 로고
    • Accuracy and precision of MR velocity mapping in measurement of stenotic cross-sectional area, flow rate, and pressure gradient
    • COI: 1:STN:280:DyaK3s7pt1KhtQ%3D%3D, PID: 8448407
    • Sondergaard L, Stahlberg F, Thomsen C, Stensgaard A, Lindvig K, Henriksen O (1993) Accuracy and precision of MR velocity mapping in measurement of stenotic cross-sectional area, flow rate, and pressure gradient. J Magn Reson Imaging 3(2):433–437
    • (1993) J Magn Reson Imaging , vol.3 , Issue.2 , pp. 433-437
    • Sondergaard, L.1    Stahlberg, F.2    Thomsen, C.3    Stensgaard, A.4    Lindvig, K.5    Henriksen, O.6
  • 10
    • 0033026809 scopus 로고    scopus 로고
    • Functional evaluation of extracardiac ventriculopulmonary conduits and of the right ventricle with magnetic resonance imaging and velocity mapping
    • COI: 1:STN:280:DyaK1M3gsVKrtA%3D%3D, PID: 10190411
    • Holmqvist C, Oskarsson G, Stahlberg F, Thilen U, Bjorkhem G, Laurin S (1999) Functional evaluation of extracardiac ventriculopulmonary conduits and of the right ventricle with magnetic resonance imaging and velocity mapping. Am J Cardiol 83(6):926–932
    • (1999) Am J Cardiol , vol.83 , Issue.6 , pp. 926-932
    • Holmqvist, C.1    Oskarsson, G.2    Stahlberg, F.3    Thilen, U.4    Bjorkhem, G.5    Laurin, S.6
  • 11
    • 84867174612 scopus 로고    scopus 로고
    • Evaluation of aortic valve stenosis using cardiovascular magnetic resonance: comparison of an original semiautomated analysis of phase-contrast cardiovascular magnetic resonance with Doppler echocardiography
    • PID: 22798520
    • Defrance C, Bollache E, Kachenoura N, Perdrix L, Hrynchyshyn N, Bruguiere E, Redheuil A, Diebold B, Mousseaux E (2012) Evaluation of aortic valve stenosis using cardiovascular magnetic resonance: comparison of an original semiautomated analysis of phase-contrast cardiovascular magnetic resonance with Doppler echocardiography. Circ Cardiovasc Imaging 5(5):604–612
    • (2012) Circ Cardiovasc Imaging , vol.5 , Issue.5 , pp. 604-612
    • Defrance, C.1    Bollache, E.2    Kachenoura, N.3    Perdrix, L.4    Hrynchyshyn, N.5    Bruguiere, E.6    Redheuil, A.7    Diebold, B.8    Mousseaux, E.9
  • 12
    • 74049152552 scopus 로고    scopus 로고
    • Aortic valve stenotic area calculation from phase contrast cardiovascular magnetic resonance: the importance of short echo time
    • PID: 19925667
    • O’Brien KR, Gabriel RS, Greiser A, Cowan BR, Young AA, Kerr AJ (2009) Aortic valve stenotic area calculation from phase contrast cardiovascular magnetic resonance: the importance of short echo time. J Cardiovasc Magn Reson 11:49
    • (2009) J Cardiovasc Magn Reson , vol.11 , pp. 49
    • O’Brien, K.R.1    Gabriel, R.S.2    Greiser, A.3    Cowan, B.R.4    Young, A.A.5    Kerr, A.J.6
  • 14
    • 69449089427 scopus 로고    scopus 로고
    • Phase contrast ultrashort TE: a more reliable technique for measurement of high-velocity turbulent stenotic jets
    • PID: 19488986
    • O’Brien KR, Myerson SG, Cowan BR, Young AA, Robson MD (2009) Phase contrast ultrashort TE: a more reliable technique for measurement of high-velocity turbulent stenotic jets. Magn Reson Med 62(3):626–636
    • (2009) Magn Reson Med , vol.62 , Issue.3 , pp. 626-636
    • O’Brien, K.R.1    Myerson, S.G.2    Cowan, B.R.3    Young, A.A.4    Robson, M.D.5
  • 15
    • 0042592959 scopus 로고    scopus 로고
    • Rapid quantitation of high-speed flow jets
    • PID: 12876713
    • Nayak KS, Hu BS, Nishimura DG (2003) Rapid quantitation of high-speed flow jets. Magn Reson Med 50(2):366–372
    • (2003) Magn Reson Med , vol.50 , Issue.2 , pp. 366-372
    • Nayak, K.S.1    Hu, B.S.2    Nishimura, D.G.3
  • 16
    • 0031403409 scopus 로고    scopus 로고
    • Combined analysis of spatial and velocity displacement artifacts in phase contrast measurements of complex flows
    • COI: 1:STN:280:DyaK2s3ksF2nug%3D%3D, PID: 9090588
    • Steinman DA, Ethier CR, Rutt BK (1997) Combined analysis of spatial and velocity displacement artifacts in phase contrast measurements of complex flows. J Magn Reson Imaging 7(2):339–346
    • (1997) J Magn Reson Imaging , vol.7 , Issue.2 , pp. 339-346
    • Steinman, D.A.1    Ethier, C.R.2    Rutt, B.K.3
  • 17
    • 0242336201 scopus 로고    scopus 로고
    • Improvements in spiral MR imaging
    • COI: 1:STN:280:DC%2BD3c%2FitFKnsA%3D%3D, PID: 10555171
    • Bornert P, Schomberg H, Aldefeld B, Groen J (1999) Improvements in spiral MR imaging. MAGMA 9(1–2):29–41
    • (1999) MAGMA , vol.9 , Issue.1-2 , pp. 29-41
    • Bornert, P.1    Schomberg, H.2    Aldefeld, B.3    Groen, J.4
  • 18
    • 84886617616 scopus 로고    scopus 로고
    • Accuracy of four-dimensional phase-contrast velocity mapping for blood flow visualizations: a phantom study
    • PID: 23486562
    • Nilsson A, Bloch KM, Toger J, Heiberg E, Stahlberg F (2013) Accuracy of four-dimensional phase-contrast velocity mapping for blood flow visualizations: a phantom study. Acta Radiol 54(6):663–671
    • (2013) Acta Radiol , vol.54 , Issue.6 , pp. 663-671
    • Nilsson, A.1    Bloch, K.M.2    Toger, J.3    Heiberg, E.4    Stahlberg, F.5
  • 19
    • 84859724260 scopus 로고    scopus 로고
    • Analysis and correction of background velocity offsets in phase-contrast flow measurements using magnetic field monitoring
    • PID: 21826731
    • Giese D, Haeberlin M, Barmet C, Pruessmann KP, Schaeffter T, Kozerke S (2012) Analysis and correction of background velocity offsets in phase-contrast flow measurements using magnetic field monitoring. Magn Reson Med 67(5):1294–1302
    • (2012) Magn Reson Med , vol.67 , Issue.5 , pp. 1294-1302
    • Giese, D.1    Haeberlin, M.2    Barmet, C.3    Pruessmann, K.P.4    Schaeffter, T.5    Kozerke, S.6
  • 21
    • 84864692702 scopus 로고    scopus 로고
    • Flow and peak velocity measurements in patients with aortic valve stenosis using phase contrast MR accelerated with k-t BLAST
    • PID: 21724348
    • Thunberg P, Emilsson K, Rask P, Kahari A (2012) Flow and peak velocity measurements in patients with aortic valve stenosis using phase contrast MR accelerated with k-t BLAST. Eur J Radiol 81(9):2203–2207
    • (2012) Eur J Radiol , vol.81 , Issue.9 , pp. 2203-2207
    • Thunberg, P.1    Emilsson, K.2    Rask, P.3    Kahari, A.4
  • 22
    • 0029964796 scopus 로고    scopus 로고
    • Temporally resolved 3D phase-contrast imaging
    • COI: 1:STN:280:DyaK2s%2Fntlartw%3D%3D, PID: 8916033
    • Wigstrom L, Sjoqvist L, Wranne B (1996) Temporally resolved 3D phase-contrast imaging. Magn Reson Med 36(5):800–803
    • (1996) Magn Reson Med , vol.36 , Issue.5 , pp. 800-803
    • Wigstrom, L.1    Sjoqvist, L.2    Wranne, B.3
  • 24
    • 0032751769 scopus 로고    scopus 로고
    • 4D magnetic resonance velocity mapping of blood flow patterns in the aorta in young vs. elderly normal subjects
    • COI: 1:STN:280:DC%2BD3c%2FhvVSrsA%3D%3D, PID: 10548800
    • Bogren HG, Buonocore MH (1999) 4D magnetic resonance velocity mapping of blood flow patterns in the aorta in young vs. elderly normal subjects. J Magn Reson Imaging 10(5):861–869
    • (1999) J Magn Reson Imaging , vol.10 , Issue.5 , pp. 861-869
    • Bogren, H.G.1    Buonocore, M.H.2
  • 25
    • 55749085612 scopus 로고    scopus 로고
    • Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters
    • COI: 1:STN:280:DC%2BD1cjhtVCqtQ%3D%3D, PID: 18956416
    • Stalder AF, Russe MF, Frydrychowicz A, Bock J, Hennig J, Markl M (2008) Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters. Magn Reson Med 60(5):1218–1231
    • (2008) Magn Reson Med , vol.60 , Issue.5 , pp. 1218-1231
    • Stalder, A.F.1    Russe, M.F.2    Frydrychowicz, A.3    Bock, J.4    Hennig, J.5    Markl, M.6
  • 26
    • 51449112368 scopus 로고    scopus 로고
    • Assessment of fluctuating velocities in disturbed cardiovascular blood flow: in vivo feasibility of generalized phase-contrast MRI
    • PID: 18777557
    • Dyverfeldt P, Kvitting JP, Sigfridsson A, Engvall J, Bolger AF, Ebbers T (2008) Assessment of fluctuating velocities in disturbed cardiovascular blood flow: in vivo feasibility of generalized phase-contrast MRI. J Magn Reson Imaging 28(3):655–663
    • (2008) J Magn Reson Imaging , vol.28 , Issue.3 , pp. 655-663
    • Dyverfeldt, P.1    Kvitting, J.P.2    Sigfridsson, A.3    Engvall, J.4    Bolger, A.F.5    Ebbers, T.6
  • 28
    • 44449140570 scopus 로고    scopus 로고
    • Evaluation of bicuspid aortic valve and aortic coarctation with 4D flow magnetic resonance imaging
    • PID: 18506021
    • Hope MD, Meadows AK, Hope TA, Ordovas KG, Reddy GP, Alley MT, Higgins CB (2008) Evaluation of bicuspid aortic valve and aortic coarctation with 4D flow magnetic resonance imaging. Circulation 117(21):2818–2819
    • (2008) Circulation , vol.117 , Issue.21 , pp. 2818-2819
    • Hope, M.D.1    Meadows, A.K.2    Hope, T.A.3    Ordovas, K.G.4    Reddy, G.P.5    Alley, M.T.6    Higgins, C.B.7
  • 31
  • 32
    • 80054793848 scopus 로고    scopus 로고
    • Three-dimensional phase contrast angiography of the mouse aortic arch using spiral MRI
    • PID: 21656547
    • Janiczek RL, Blackman BR, Roy RJ, Meyer CH, Acton ST, Epstein FH (2011) Three-dimensional phase contrast angiography of the mouse aortic arch using spiral MRI. Magn Reson Med 66(5):1382–1390
    • (2011) Magn Reson Med , vol.66 , Issue.5 , pp. 1382-1390
    • Janiczek, R.L.1    Blackman, B.R.2    Roy, R.J.3    Meyer, C.H.4    Acton, S.T.5    Epstein, F.H.6
  • 33
    • 84872848895 scopus 로고    scopus 로고
    • Four-dimensional velocity-encoded magnetic resonance imaging improves blood flow quantification in patients with complex accelerated flow
    • PID: 22976284
    • Nordmeyer S, Riesenkampff E, Messroghli D, Kropf S, Nordmeyer J, Berger F, Kuehne T (2013) Four-dimensional velocity-encoded magnetic resonance imaging improves blood flow quantification in patients with complex accelerated flow. J Magn Reson Imaging 37(1):208–216
    • (2013) J Magn Reson Imaging , vol.37 , Issue.1 , pp. 208-216
    • Nordmeyer, S.1    Riesenkampff, E.2    Messroghli, D.3    Kropf, S.4    Nordmeyer, J.5    Berger, F.6    Kuehne, T.7
  • 34
    • 80052971580 scopus 로고    scopus 로고
    • In vivo noninvasive 4D pressure difference mapping in the human aorta: phantom comparison and application in healthy volunteers and patients
    • PID: 21437978
    • Bock J, Frydrychowicz A, Lorenz R, Hirtler D, Barker AJ, Johnson KM, Arnold R, Burkhardt H, Hennig J, Markl M (2011) In vivo noninvasive 4D pressure difference mapping in the human aorta: phantom comparison and application in healthy volunteers and patients. Magn Reson Med 66(4):1079–1088
    • (2011) Magn Reson Med , vol.66 , Issue.4 , pp. 1079-1088
    • Bock, J.1    Frydrychowicz, A.2    Lorenz, R.3    Hirtler, D.4    Barker, A.J.5    Johnson, K.M.6    Arnold, R.7    Burkhardt, H.8    Hennig, J.9    Markl, M.10
  • 35
    • 80053061798 scopus 로고    scopus 로고
    • Noninvasive assessment of transstenotic pressure gradients in porcine renal artery stenoses by using vastly undersampled phase-contrast MR angiography
    • PID: 21813739
    • Bley TA, Johnson KM, Francois CJ, Reeder SB, Schiebler ML, Landgraf BR, Consigny D, Grist TM, Wieben O (2011) Noninvasive assessment of transstenotic pressure gradients in porcine renal artery stenoses by using vastly undersampled phase-contrast MR angiography. Radiology 261(1):266–273
    • (2011) Radiology , vol.261 , Issue.1 , pp. 266-273
    • Bley, T.A.1    Johnson, K.M.2    Francois, C.J.3    Reeder, S.B.4    Schiebler, M.L.5    Landgraf, B.R.6    Consigny, D.7    Grist, T.M.8    Wieben, O.9
  • 37
    • 77950883773 scopus 로고    scopus 로고
    • Computational simulations and experimental studies of 3D phase-contrast imaging of fluid flow in carotid bifurcation geometries
    • PID: 20373438
    • Marshall I (2010) Computational simulations and experimental studies of 3D phase-contrast imaging of fluid flow in carotid bifurcation geometries. J Magn Reson Imaging 31(4):928–934
    • (2010) J Magn Reson Imaging , vol.31 , Issue.4 , pp. 928-934
    • Marshall, I.1
  • 38
    • 0026912776 scopus 로고
    • Minimizing TE in moment-nulled or flow-encoded two- and three-dimensional gradient-echo imaging
    • COI: 1:STN:280:DyaK3s%2FgsFajsw%3D%3D, PID: 1392252
    • Bernstein MA, Shimakawa A, Pelc NJ (1992) Minimizing TE in moment-nulled or flow-encoded two- and three-dimensional gradient-echo imaging. J Magn Reson Imaging 2(5):583–588
    • (1992) J Magn Reson Imaging , vol.2 , Issue.5 , pp. 583-588
    • Bernstein, M.A.1    Shimakawa, A.2    Pelc, N.J.3
  • 39
    • 84857015934 scopus 로고    scopus 로고
    • Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or k-t BLAST: head to head comparison and validation at 1.5 T and 3 T
    • Carlsson M, Toger J, Kanski M, Bloch KM, Stahlberg F, Heiberg E, Arheden H (2011) Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or k-t BLAST: head to head comparison and validation at 1.5 T and 3 T. J Cardiovasc Magn Reson 13:55
    • (2011) J Cardiovasc Magn Reson , vol.13 , pp. 55
    • Carlsson, M.1    Toger, J.2    Kanski, M.3    Bloch, K.M.4    Stahlberg, F.5    Heiberg, E.6    Arheden, H.7
  • 42
    • 84865655615 scopus 로고    scopus 로고
    • Single-phase and two-phase flow through thin and thick orifices in horizontal pipes
    • Roul MK, Dash SK (2012) Single-phase and two-phase flow through thin and thick orifices in horizontal pipes. J Fluids Eng 134(9):3274
    • (2012) J Fluids Eng , vol.134 , Issue.9 , pp. 3274
    • Roul, M.K.1    Dash, S.K.2
  • 43
    • 33044504607 scopus 로고
    • A calculation procedure for heat, mass and momentum transfer in three-dimensional parabolic flows
    • Patankar SV, Spalding DB (1972) A calculation procedure for heat, mass and momentum transfer in three-dimensional parabolic flows. Int J Heat Mass Transf 15(10):1787–1806
    • (1972) Int J Heat Mass Transf , vol.15 , Issue.10 , pp. 1787-1806
    • Patankar, S.V.1    Spalding, D.B.2
  • 44
    • 0026804722 scopus 로고
    • Development of turbulence models for shear flows by a double expansion technique
    • COI: 1:CAS:528:DyaK38Xkslagurs%3D
    • Yakhot V, Orszag SA, Thangam S, Gatski TB, Speziale CG (1992) Development of turbulence models for shear flows by a double expansion technique. Phys Fluids A Fluid Dyn 4(7):1510–1520
    • (1992) Phys Fluids A Fluid Dyn , vol.4 , Issue.7 , pp. 1510-1520
    • Yakhot, V.1    Orszag, S.A.2    Thangam, S.3    Gatski, T.B.4    Speziale, C.G.5
  • 45
    • 0028486598 scopus 로고
    • 2-Equation eddy-viscosity turbulence models for engineering applications
    • Menter FR (1994) 2-Equation eddy-viscosity turbulence models for engineering applications. AIAA J 32(8):1598–1605
    • (1994) AIAA J , vol.32 , Issue.8 , pp. 1598-1605
    • Menter, F.R.1
  • 46
    • 0026170053 scopus 로고
    • Modeling the pressure strain correlation of turbulence—an invariant dynamic-systems approach
    • Speziale CG, Sarkar S, Gatski TB (1991) Modeling the pressure strain correlation of turbulence—an invariant dynamic-systems approach. J Fluid Mech 227:245–272
    • (1991) J Fluid Mech , vol.227 , pp. 245-272
    • Speziale, C.G.1    Sarkar, S.2    Gatski, T.B.3
  • 48
    • 35448951369 scopus 로고    scopus 로고
    • About Boussinesq’s turbulent viscosity hypothesis: historical remarks and a direct evaluation of its validity
    • COI: 1:CAS:528:DC%2BD2sXht1CnsrzM
    • Schmitt FG (2007) About Boussinesq’s turbulent viscosity hypothesis: historical remarks and a direct evaluation of its validity. CR Mec 335(9–10):617–627
    • (2007) CR Mec , vol.335 , Issue.9-10 , pp. 617-627
    • Schmitt, F.G.1
  • 49
    • 79958830004 scopus 로고    scopus 로고
    • Time resolved velocity measurements of unsteady systems using spiral imaging
    • COI: 1:CAS:528:DC%2BC3MXnsVCksrw%3D, PID: 21514194
    • Tayler AB, Holland DJ, Sederman AJ, Gladden LF (2011) Time resolved velocity measurements of unsteady systems using spiral imaging. J Magn Reson 211(1):1–10
    • (2011) J Magn Reson , vol.211 , Issue.1 , pp. 1-10
    • Tayler, A.B.1    Holland, D.J.2    Sederman, A.J.3    Gladden, L.F.4
  • 50
    • 0028099916 scopus 로고
    • Pulse sequence design for MR velocity mapping of complex flow: notes on the necessity of low echo times
    • COI: 1:STN:280:DyaK2M7lslWmsA%3D%3D, PID: 7854031
    • Stahlberg F, Thomsen C, Sondergaard L, Henriksen O (1994) Pulse sequence design for MR velocity mapping of complex flow: notes on the necessity of low echo times. Magn Reson Imaging 12(8):1255–1262
    • (1994) Magn Reson Imaging , vol.12 , Issue.8 , pp. 1255-1262
    • Stahlberg, F.1    Thomsen, C.2    Sondergaard, L.3    Henriksen, O.4
  • 51
    • 0026953787 scopus 로고
    • Effects of acceleration on the accuracy of MR phase velocity measurements
    • COI: 1:STN:280:DyaK3s%2Fns1Sguw%3D%3D, PID: 1446110
    • Oshinski JN, Ku DN, Bohning DE, Pettigrew RI (1992) Effects of acceleration on the accuracy of MR phase velocity measurements. J Magn Reson Imaging 2(6):665–670
    • (1992) J Magn Reson Imaging , vol.2 , Issue.6 , pp. 665-670
    • Oshinski, J.N.1    Ku, D.N.2    Bohning, D.E.3    Pettigrew, R.I.4
  • 52
    • 0029063215 scopus 로고
    • Motion induced phase shifts in MR: acceleration effects in quantitative flow measurements–a reconsideration
    • COI: 1:STN:280:DyaK2MznvFCluw%3D%3D, PID: 7651112
    • Kouwenhoven M, Hofman MB, Sprenger M (1995) Motion induced phase shifts in MR: acceleration effects in quantitative flow measurements–a reconsideration. Magn Reson Med 33(6):766–777
    • (1995) Magn Reson Med , vol.33 , Issue.6 , pp. 766-777
    • Kouwenhoven, M.1    Hofman, M.B.2    Sprenger, M.3
  • 54
    • 0024588225 scopus 로고
    • Lessons from in vitro models of small, irregular, multiple and tunnel-like stenoses relevant to clinical stenoses of valves and small vessels
    • COI: 1:STN:280:DyaL1M7ktVSqtw%3D%3D, PID: 2645341
    • Popp RL, Teplitsky I (1989) Lessons from in vitro models of small, irregular, multiple and tunnel-like stenoses relevant to clinical stenoses of valves and small vessels. J Am Coll Cardiol 13(3):716–722
    • (1989) J Am Coll Cardiol , vol.13 , Issue.3 , pp. 716-722
    • Popp, R.L.1    Teplitsky, I.2
  • 55
    • 0029263359 scopus 로고
    • Understanding acceleration-induced displacement artifacts in phase-contrast MR velocity measurements
    • COI: 1:STN:280:DyaK2M3osVCmuw%3D%3D, PID: 7766984
    • Frayne R, Rutt BK (1995) Understanding acceleration-induced displacement artifacts in phase-contrast MR velocity measurements. J Magn Reson Imaging 5(2):207–215
    • (1995) J Magn Reson Imaging , vol.5 , Issue.2 , pp. 207-215
    • Frayne, R.1    Rutt, B.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.