메뉴 건너뛰기




Volumn 15, Issue 8, 2015, Pages 19212-19224

Electrochemical impedance immunosensor based on self-assembled monolayers for rapid detection of Escherichia coli O157:H7 with signal amplification using lectin

Author keywords

Escherichia coli O157:H7; Impedance immunosensor; Lectin; Screen printed interdigitated microelectrode

Indexed keywords

BINDING SITES; BIOSENSORS; CHEMICAL CONTAMINATION; CHEMICAL SENSORS; COSTS; ELECTRODES; ESCHERICHIA COLI; FOOD MICROBIOLOGY; FOOD SAFETY; IMMUNOSENSORS; MICROELECTRODES; PATHOGENS; PROTEINS; SIGNAL DETECTION; SIGNAL PROCESSING;

EID: 84938842072     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s150819212     Document Type: Article
Times cited : (84)

References (39)
  • 1
    • 78049291873 scopus 로고    scopus 로고
    • Escherichia coli O157
    • Pennington, H. Escherichia coli O157. Lancet 2010, 376, 1428-1435.
    • (2010) Lancet , vol.376 , pp. 1428-1435
    • Pennington, H.1
  • 3
    • 84855432040 scopus 로고    scopus 로고
    • Economic burden from health losses due to foodborne illness in the United States
    • Scharff, R.L. Economic burden from health losses due to foodborne illness in the United States. J. Food Protect. 2012, 75, 123-131.
    • (2012) J. Food Protect , vol.75 , pp. 123-131
    • Scharff, R.L.1
  • 4
    • 0026398187 scopus 로고
    • The epidemiology of infections caused by Escherichia coli O157: H7, other enterohemorrhagic E. coli, and the associated hemolytic uremic syndrome
    • Griffin, P.M.; Tauxe, R.V. The epidemiology of infections caused by Escherichia coli O157: H7, other enterohemorrhagic E. coli, and the associated hemolytic uremic syndrome. Epidemiol. Rev. 1991, 13, 60-98.
    • (1991) Epidemiol. Rev , vol.13 , pp. 60-98
    • Griffin, P.M.1    Tauxe, R.V.2
  • 5
    • 35748941946 scopus 로고    scopus 로고
    • Immunosensors for rapid detection of Escherichia coli O157: H7-Perspectives for use in the meat processing industry
    • Tokarskyy, O.; Marshall, D.L. Immunosensors for rapid detection of Escherichia coli O157: H7-Perspectives for use in the meat processing industry. Food Microbiol. 2008, 25, 1-12.
    • (2008) Food Microbiol , vol.25 , pp. 1-12
    • Tokarskyy, O.1    Marshall, D.L.2
  • 6
    • 0032485801 scopus 로고    scopus 로고
    • Quantitative risk assessment for Escherichia coli O157: H7 in ground beef hamburgers
    • Cassin, M.H.; Lammerding, A.M.; Todd, E.C.; Ross, W.; McColl, R.S. Quantitative risk assessment for Escherichia coli O157: H7 in ground beef hamburgers. Int. J. Food Microbiol. 1998, 41, 21-44.
    • (1998) Int. J. Food Microbiol , vol.41 , pp. 21-44
    • Cassin, M.H.1    Lammerding, A.M.2    Todd, E.C.3    Ross, W.4    McColl, R.S.5
  • 7
    • 0033178514 scopus 로고    scopus 로고
    • Survival of enterohemorrhagic Escherichia coli O157: H7 in bovine feces applied to lettuce and the effectiveness of chlorinated water as a disinfectant
    • Beuchat, L.R. Survival of enterohemorrhagic Escherichia coli O157: H7 in bovine feces applied to lettuce and the effectiveness of chlorinated water as a disinfectant. J. Food Protect. 1999, 62, 845-849.
    • (1999) J. Food Protect , vol.62 , pp. 845-849
    • Beuchat, L.R.1
  • 8
    • 1242291836 scopus 로고    scopus 로고
    • Serotypes, virulence genes, and intimin types of Shiga toxin (verotoxin)-producing Escherichia coli isolates from cattle in Spain and identification of a new intimin variant gene (eae-ξ)
    • Blanco, M.; Blanco, J.; Mora, A.; Dahbi, G.; Alonso, M.; González, E.; Bernárdez, M.; Blanco, J. Serotypes, virulence genes, and intimin types of Shiga toxin (verotoxin)-producing Escherichia coli isolates from cattle in Spain and identification of a new intimin variant gene (eae-ξ). J. Clin. Microbiol. 2004, 42, 645-651.
    • (2004) J. Clin. Microbiol , vol.42 , pp. 645-651
    • Blanco, M.1    Blanco, J.2    Mora, A.3    Dahbi, G.4    Alonso, M.5    González, E.6    Bernárdez, M.7    Blanco, J.8
  • 9
    • 84892775474 scopus 로고    scopus 로고
    • Sensitive chemiluminescence immunoassay for E. coli O157:H7 detection with signal dual-amplification using glucose oxidase and laccase
    • Zhang, Y.; Tan, C.; Fei, R.; Liu, X.; Zhou, Y.; Chen, J.; Chen, H.; Zhou, R.; Hu, Y. Sensitive chemiluminescence immunoassay for E. coli O157:H7 detection with signal dual-amplification using glucose oxidase and laccase. Anal. Chem. 2014, 86, 1115-1122.
    • (2014) Anal. Chem , vol.86 , pp. 1115-1122
    • Zhang, Y.1    Tan, C.2    Fei, R.3    Liu, X.4    Zhou, Y.5    Chen, J.6    Chen, H.7    Zhou, R.8    Hu, Y.9
  • 10
    • 84922511435 scopus 로고    scopus 로고
    • Achieving reproducible performance of electrochemical, folding aptamer-based sensors on microelectrodes: Challenges and prospects
    • Liu, J.; Wagan, S.; Dávila, M.M.; Taylor, J.; White, R.J. Achieving reproducible performance of electrochemical, folding aptamer-based sensors on microelectrodes: challenges and prospects. Anal. Chem. 2014, 86, 11417-11424.
    • (2014) Anal. Chem , vol.86 , pp. 11417-11424
    • Liu, J.1    Wagan, S.2    Dávila, M.M.3    Taylor, J.4    White, R.J.5
  • 11
    • 0036947839 scopus 로고    scopus 로고
    • Electrochemical sensors based on carbon nanotubes
    • Zhao, Q.; Gan, Z.; Zhuang, Q. Electrochemical sensors based on carbon nanotubes. Electroanalysis 2002, 14, 1609-1613.
    • (2002) Electroanalysis , vol.14 , pp. 1609-1613
    • Zhao, Q.1    Gan, Z.2    Zhuang, Q.3
  • 12
    • 78651073285 scopus 로고    scopus 로고
    • Quantum-dots-based fluoroimmunoassay for the rapid and sensitive detection of avian influenza virus subtype H5N1
    • Chen, L.; Sheng, Z.; Zhang, A.; Guo, X.; Li, J.; Han, H.; Jin, M. Quantum-dots-based fluoroimmunoassay for the rapid and sensitive detection of avian influenza virus subtype H5N1. Luminescence 2010, 25, 419-423.
    • (2010) Luminescence , vol.25 , pp. 419-423
    • Chen, L.1    Sheng, Z.2    Zhang, A.3    Guo, X.4    Li, J.5    Han, H.6    Jin, M.7
  • 13
    • 77953295630 scopus 로고    scopus 로고
    • Graphene based electrochemical sensors and biosensors: A review
    • Shao, Y.; Wang, J.; Wu, H.; Liu, J.; Aksay, I.A.; Lin, Y. Graphene based electrochemical sensors and biosensors: A review. Electroanalysis 2010, 22, 1027-1036.
    • (2010) Electroanalysis , vol.22 , pp. 1027-1036
    • Shao, Y.1    Wang, J.2    Wu, H.3    Liu, J.4    Aksay, I.A.5    Lin, Y.6
  • 14
    • 84890847574 scopus 로고    scopus 로고
    • Ultrasensitive electrochemical aptasensor for ochratoxin A based on two-level cascaded signal amplification strategy
    • Yang, X.; Qian, J.; Jiang, L.; Yan, Y.; Wang, K.; Liu, Q.; Wang, K. Ultrasensitive electrochemical aptasensor for ochratoxin A based on two-level cascaded signal amplification strategy. Bioelectrochemistry 2014, 96, 7-13.
    • (2014) Bioelectrochemistry , vol.96 , pp. 7-13
    • Yang, X.1    Qian, J.2    Jiang, L.3    Yan, Y.4    Wang, K.5    Liu, Q.6    Wang, K.7
  • 15
    • 84861234929 scopus 로고    scopus 로고
    • An electrochemical immunosensor for ochratoxin A determination in wines based on a monoclonal antibody and paramagnetic microbeads
    • Vidal, J.C.; Bonel, L.; Ezquerra, A.; Duato, P.; Castillo, J.R. An electrochemical immunosensor for ochratoxin A determination in wines based on a monoclonal antibody and paramagnetic microbeads. Anal. Bioanal. Chem. 2012, 403, 1585-1593.
    • (2012) Anal. Bioanal. Chem , vol.403 , pp. 1585-1593
    • Vidal, J.C.1    Bonel, L.2    Ezquerra, A.3    Duato, P.4    Castillo, J.R.5
  • 16
    • 67349271849 scopus 로고    scopus 로고
    • Gold screen-printed-based impedimetric immunobiosensors for direct and sensitive Escherichia coli quantisation
    • Escamilla-Gómez, V.; Campuzano, S.; Pedrero, M.; Pingarrón, J.M. Gold screen-printed-based impedimetric immunobiosensors for direct and sensitive Escherichia coli quantisation. Biosens. Bioelectron. 2009, 24, 3365-3371.
    • (2009) Biosens. Bioelectron , vol.24 , pp. 3365-3371
    • Escamilla-Gómez, V.1    Campuzano, S.2    Pedrero, M.3    Pingarrón, J.M.4
  • 17
    • 84858952604 scopus 로고    scopus 로고
    • New trends in impedimetric biosensors for the detection of foodborne pathogenic bacteria
    • Wang, Y.; Ye, Z.; Ying, Y. New trends in impedimetric biosensors for the detection of foodborne pathogenic bacteria. Sensors 2012, 12, 3449-3471.
    • (2012) Sensors , vol.12 , pp. 3449-3471
    • Wang, Y.1    Ye, Z.2    Ying, Y.3
  • 18
    • 79951684094 scopus 로고    scopus 로고
    • Determination of mercury in ambient water samples by anodic stripping voltammetry on screen-printed gold electrodes
    • Bernalte, E.; Sánchez, C.M.; Gil, E.P. Determination of mercury in ambient water samples by anodic stripping voltammetry on screen-printed gold electrodes. Anal. Chim. Acta 2011, 689, 60-64.
    • (2011) Anal. Chim. Acta , vol.689 , pp. 60-64
    • Bernalte, E.1    Sánchez, C.M.2    Gil, E.P.3
  • 19
  • 20
    • 84874350269 scopus 로고    scopus 로고
    • A nanoporous membrane-based impedimetric immunosensor for label-free detection of pathogenic bacteria in whole milk
    • Joung, C.K.; Kim, H.N.; Lim, M.C.; Jeon, T.J.; Kim, H.Y.; Kim, Y.R. A nanoporous membrane-based impedimetric immunosensor for label-free detection of pathogenic bacteria in whole milk. Biosens. Bioelectron. 2013, 44, 210-215.
    • (2013) Biosens. Bioelectron , vol.44 , pp. 210-215
    • Joung, C.K.1    Kim, H.N.2    Lim, M.C.3    Jeon, T.J.4    Kim, H.Y.5    Kim, Y.R.6
  • 21
    • 84887966491 scopus 로고    scopus 로고
    • A micromachined impedance biosensor for accurate and rapid detection of E. coli O157:H7
    • Dastider, S.G.; Barizuddin, S.; Dweik, M.; Almasri, M. A micromachined impedance biosensor for accurate and rapid detection of E. coli O157:H7. RSC Adv. 2013, 3, 26297-26306.
    • (2013) RSC Adv , vol.3 , pp. 26297-26306
    • Dastider, S.G.1    Barizuddin, S.2    Dweik, M.3    Almasri, M.4
  • 22
    • 29144528944 scopus 로고    scopus 로고
    • A mixed self-assembled monolayer-based surface plasmon immunosensor for detection of E. coli O157: H7
    • Subramanian, A.; Irudayaraj, J.; Ryan, T. A mixed self-assembled monolayer-based surface plasmon immunosensor for detection of E. coli O157: H7. Biosens. Bioelectron. 2006, 21, 998-1006.
    • (2006) Biosens. Bioelectron , vol.21 , pp. 998-1006
    • Subramanian, A.1    Irudayaraj, J.2    Ryan, T.3
  • 23
    • 0345735487 scopus 로고    scopus 로고
    • A self-assembled monolayer-based piezoelectric immunosensor for rapid detection of Escherichia coli O157:H7
    • Su, X.; Li, Y. A self-assembled monolayer-based piezoelectric immunosensor for rapid detection of Escherichia coli O157:H7. Biosens. Bioelectron. 2004, 19, 563-574.
    • (2004) Biosens. Bioelectron , vol.19 , pp. 563-574
    • Su, X.1    Li, Y.2
  • 24
    • 79954617313 scopus 로고    scopus 로고
    • Immobilization of bio-macromolecules on self-assembled monolayers: Methods and sensor applications
    • Samanta, D.; Sarkar, A. Immobilization of bio-macromolecules on self-assembled monolayers: methods and sensor applications. Chem. Soc. Rev. 2011, 40, 2567-2592.
    • (2011) Chem. Soc. Rev , vol.40 , pp. 2567-2592
    • Samanta, D.1    Sarkar, A.2
  • 25
    • 67349115176 scopus 로고    scopus 로고
    • Interdigitated array microelectrodes based impedance biosensors for detection of bacterial cells
    • Varshney, M.; Li, Y. Interdigitated array microelectrodes based impedance biosensors for detection of bacterial cells. Biosens. Bioelectron. 2009, 24, 2951-2960.
    • (2009) Biosens. Bioelectron , vol.24 , pp. 2951-2960
    • Varshney, M.1    Li, Y.2
  • 26
    • 84875145245 scopus 로고    scopus 로고
    • A disposable electrochemical immunosensor arrays using 4-channel screen-printed carbon electrode for simultaneous detection of Escherichia coli O157:H7 and Enterobacter sakazakii
    • Dou, W.; Tang, W.; Zhao, G. A disposable electrochemical immunosensor arrays using 4-channel screen-printed carbon electrode for simultaneous detection of Escherichia coli O157:H7 and Enterobacter sakazakii. Electrochim. Acta 2013, 97, 79-85.
    • (2013) Electrochim. Acta , vol.97 , pp. 79-85
    • Dou, W.1    Tang, W.2    Zhao, G.3
  • 27
    • 40349083705 scopus 로고    scopus 로고
    • Modified fabrication process of protein chips using a short-chain self-assembled monolayer
    • Jang, L.S.; Keng, H.K. Modified fabrication process of protein chips using a short-chain self-assembled monolayer. Biomed. Microdevices 2008, 10, 203-211.
    • (2008) Biomed. Microdevices , vol.10 , pp. 203-211
    • Jang, L.S.1    Keng, H.K.2
  • 28
    • 34548836006 scopus 로고    scopus 로고
    • Mass spectrometric identification of N-linked glycopeptides using lectin-mediated affinity capture and glycosylation site-specific stable isotope tagging
    • Kaji, H.; Yamauchi, Y.; Takahashi, N.; Isobe, T. Mass spectrometric identification of N-linked glycopeptides using lectin-mediated affinity capture and glycosylation site-specific stable isotope tagging. Nat. Protocols 2007, 1, 3019-3027.
    • (2007) Nat. Protocols , vol.1 , pp. 3019-3027
    • Kaji, H.1    Yamauchi, Y.2    Takahashi, N.3    Isobe, T.4
  • 29
    • 33947360777 scopus 로고    scopus 로고
    • Nonlabeled quartz crystal microbalance biosensor for bacterial detection using carbohydrate and lectin recognitions
    • Shen, Z.; Huang, M.; Xiao, C.; Zhang, Y.; Zeng, X.; Wang, P.G. Nonlabeled quartz crystal microbalance biosensor for bacterial detection using carbohydrate and lectin recognitions. Anal. Chem. 2007, 79, 2312-2319.
    • (2007) Anal. Chem , vol.79 , pp. 2312-2319
    • Shen, Z.1    Huang, M.2    Xiao, C.3    Zhang, Y.4    Zeng, X.5    Wang, P.G.6
  • 30
    • 84879728517 scopus 로고    scopus 로고
    • Impedimetric immunosensor based on gold nanoparticles modified graphene paper for label-free detection of Escherichia coli O157:H7
    • Wang, Y.; Ping, J.; Ye, Z.; Wu, J.; Ying, Y. Impedimetric immunosensor based on gold nanoparticles modified graphene paper for label-free detection of Escherichia coli O157:H7. Biosens. Bioelectron. 2013, 49, 492-498.
    • (2013) Biosens. Bioelectron , vol.49 , pp. 492-498
    • Wang, Y.1    Ping, J.2    Ye, Z.3    Wu, J.4    Ying, Y.5
  • 31
    • 14644444164 scopus 로고    scopus 로고
    • Enzyme-based impedimetric detection of PCR products using oligonucleotide-modified screen-printed gold electrodes
    • Lucarelli, F.; Marrazza, G.; Mascini, M. Enzyme-based impedimetric detection of PCR products using oligonucleotide-modified screen-printed gold electrodes. Biosens. Bioelectron. 2005, 20, 2001-2009.
    • (2005) Biosens. Bioelectron , vol.20 , pp. 2001-2009
    • Lucarelli, F.1    Marrazza, G.2    Mascini, M.3
  • 32
    • 83655192625 scopus 로고    scopus 로고
    • Electrochemical biosensors employing an internal electrode attachment site and achieving reversible, high gain detection of specific nucleic acid sequences
    • Rowe, A.A.; Chuh, K.N.; Lubin, A.A.; Miller, E.A.; Cook, B.; Hollis, D.; Plaxco, K.W. Electrochemical biosensors employing an internal electrode attachment site and achieving reversible, high gain detection of specific nucleic acid sequences. Anal. Chem. 2011, 83, 9462-9466.
    • (2011) Anal. Chem , vol.83 , pp. 9462-9466
    • Rowe, A.A.1    Chuh, K.N.2    Lubin, A.A.3    Miller, E.A.4    Cook, B.5    Hollis, D.6    Plaxco, K.W.7
  • 33
    • 78650516799 scopus 로고    scopus 로고
    • Mesoporous nickel electrodes plated with gold for the detection of glucose
    • Ling, T.R.; Li, C.S.; Jow, J.J.; Lee, J.F. Mesoporous nickel electrodes plated with gold for the detection of glucose. Electrochim. Acta 2011, 56, 1043-1050.
    • (2011) Electrochim. Acta , vol.56 , pp. 1043-1050
    • Ling, T.R.1    Li, C.S.2    Jow, J.J.3    Lee, J.F.4
  • 34
    • 33947579554 scopus 로고    scopus 로고
    • Electrochemical detection of 17β-estradiol using DNA aptamer immobilized gold electrode chip
    • Kim, Y.S.; Jung, H.S.; Matsuura, T.; Lee, H.Y.; Kawai, T.; Gu, M.B. Electrochemical detection of 17β-estradiol using DNA aptamer immobilized gold electrode chip. Biosens. Bioelectron. 2007, 22, 2525-2531.
    • (2007) Biosens. Bioelectron , vol.22 , pp. 2525-2531
    • Kim, Y.S.1    Jung, H.S.2    Matsuura, T.3    Lee, H.Y.4    Kawai, T.5    Gu, M.B.6
  • 35
    • 78049325365 scopus 로고    scopus 로고
    • Electrochemiluminescent aptamer biosensor for the determination of ochratoxin A at a gold-nanoparticles-modified gold electrode using N-(aminobutyl)-N-ethylisoluminol as a luminescent label
    • Wang, Z.; Duan, N.; Hun, X.; Wu, S. Electrochemiluminescent aptamer biosensor for the determination of ochratoxin A at a gold-nanoparticles-modified gold electrode using N-(aminobutyl)-N-ethylisoluminol as a luminescent label. Anal. Bioanal. Chem. 2010, 398, 2125-2132.
    • (2010) Anal. Bioanal. Chem , vol.398 , pp. 2125-2132
    • Wang, Z.1    Duan, N.2    Hun, X.3    Wu, S.4
  • 36
    • 41049087198 scopus 로고    scopus 로고
    • Self-assembled monolayers-based immunosensor for detection of Escherichia coli using electrochemical impedance spectroscopy
    • Geng, P.; Zhang, X.; Meng, W.; Wang, Q.; Zhang, W.; Jin, L.; Feng, Z.; Wu, Z. Self-assembled monolayers-based immunosensor for detection of Escherichia coli using electrochemical impedance spectroscopy. Electrochim. Acta 2008, 53, 4663-4668.
    • (2008) Electrochim. Acta , vol.53 , pp. 4663-4668
    • Geng, P.1    Zhang, X.2    Meng, W.3    Wang, Q.4    Zhang, W.5    Jin, L.6    Feng, Z.7    Wu, Z.8
  • 37
    • 54549090153 scopus 로고    scopus 로고
    • TiO2 nanowire bundle microelectrode based impedance immunosensor for rapid and sensitive detection of Listeria monocytogenes
    • Wang, R.; Ruan, C.; Kanayeva, D.; Lassiter, K.; Li, Y. TiO2 nanowire bundle microelectrode based impedance immunosensor for rapid and sensitive detection of Listeria monocytogenes. Nano Lett. 2008, 8, 2625-2631.
    • (2008) Nano Lett , vol.8 , pp. 2625-2631
    • Wang, R.1    Ruan, C.2    Kanayeva, D.3    Lassiter, K.4    Li, Y.5
  • 38
    • 63949086656 scopus 로고    scopus 로고
    • Microorganismsrecognition and quantification by lectin adsorptive affinity impedance
    • Gamella, M.; Campuzano, S.; Parrado, C.; Reviejo, A.J.; Pingarron, J.M. Microorganismsrecognition and quantification by lectin adsorptive affinity impedance. Talanta 2009, 78, 1303-1309.
    • (2009) Talanta , vol.78 , pp. 1303-1309
    • Gamella, M.1    Campuzano, S.2    Parrado, C.3    Reviejo, A.J.4    Pingarron, J.M.5
  • 39
    • 84867900986 scopus 로고    scopus 로고
    • Monitoring of Escherichia coli O157:H7 in food samples using lectin based surface plasmon resonance biosensor
    • Wang, Y., Ye, Z., Si, C., Ying, Y. Monitoring of Escherichia coli O157:H7 in food samples using lectin based surface plasmon resonance biosensor. Food Chem. 2013, 136, 1303-1308.
    • (2013) Food Chem , vol.136 , pp. 1303-1308
    • Wang, Y.1    Ye, Z.2    Si, C.3    Ying, Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.