메뉴 건너뛰기




Volumn 3, Issue 48, 2013, Pages 26297-26306

A micromachined impedance biosensor for accurate and rapid detection of E. Coli O157:H7

Author keywords

[No Author keywords available]

Indexed keywords

ANTIGEN-ANTIBODY BINDING; ESCHERICHIA COLI O157:H7; IMMOBILIZED ANTIBODIES; IMPEDIMETRIC DETECTIONS; INTERDIGITATED ELECTRODES; MEASUREMENT SENSITIVITY; POSITIVE DIELECTROPHORESIS; STANDARD PHOTOLITHOGRAPHY;

EID: 84887966491     PISSN: None     EISSN: 20462069     Source Type: Journal    
DOI: 10.1039/c3ra44724c     Document Type: Article
Times cited : (56)

References (46)
  • 1
    • 84887952320 scopus 로고    scopus 로고
    • http://www.cdc.gov/foodborneburden/, 2012
    • (2012)
  • 2
    • 84887935930 scopus 로고    scopus 로고
    • http://www.cdc.gov/outbreaknet/outbreaks.html, 2012
    • (2012)
  • 3
    • 84887949028 scopus 로고    scopus 로고
    • http://www.cdc.gov/salmonella/outbreaks.html, 2012
    • (2012)
  • 4
    • 84855432040 scopus 로고    scopus 로고
    • Economic Burden from Health Losses Due to Foodborne Illness in the United States
    • R. L. Scharff Economic Burden from Health Losses Due to Foodborne Illness in the United States J. Food Prot. 2012 75 1 123 131
    • (2012) J. Food Prot. , vol.75 , Issue.1 , pp. 123-131
    • Scharff, R.L.1
  • 5
    • 0035068949 scopus 로고    scopus 로고
    • Escherichia coli O157: H7 as an emerging foodborne pathogen: A literature review
    • S. S. Park R. W. Worobo R. A. Durst Escherichia coli O157: H7 as an emerging foodborne pathogen: a literature review Crit. Rev. Biotechnol. 2001 21 27 48
    • (2001) Crit. Rev. Biotechnol. , vol.21 , pp. 27-48
    • Park, S.S.1    Worobo, R.W.2    Durst, R.A.3
  • 6
    • 33645104244 scopus 로고    scopus 로고
    • Environmental survival mechanisms of the foodborne pathogen Campylobacter jejuni
    • C. Murphy C. Carroll K. N. Jordan Environmental survival mechanisms of the foodborne pathogen Campylobacter jejuni J. Appl. Microbiol. 2006 100 623 632
    • (2006) J. Appl. Microbiol. , vol.100 , pp. 623-632
    • Murphy, C.1    Carroll, C.2    Jordan, K.N.3
  • 7
    • 74449087608 scopus 로고    scopus 로고
    • An overview of foodborne pathogen detection: In the perspective of biosensors
    • V. Velusamy K. Arshak O. Korostynska K. Oliwa C. Adley An overview of foodborne pathogen detection: in the perspective of biosensors Biotechnol. Adv. 2010 28 232 254
    • (2010) Biotechnol. Adv. , vol.28 , pp. 232-254
    • Velusamy, V.1    Arshak, K.2    Korostynska, O.3    Oliwa, K.4    Adley, C.5
  • 8
    • 5544274041 scopus 로고    scopus 로고
    • Foodborne disease significance of Escherichia coli O157:H7 and other enterohemorrhagic E. Coli
    • R. L. Buchanan M. P. Doyle Foodborne disease significance of Escherichia coli O157:H7 and other enterohemorrhagic E. Coli Food Technol. 1997 51 10 69 76
    • (1997) Food Technol. , vol.51 , Issue.10 , pp. 69-76
    • Buchanan, R.L.1    Doyle, M.P.2
  • 9
    • 38349133990 scopus 로고    scopus 로고
    • Electrical/electrochemical impedance for rapid detection of foodborne pathogenic bacteria
    • L. Yang R. Bashir Electrical/electrochemical impedance for rapid detection of foodborne pathogenic bacteria Biotechnol. Adv. 2008 26 135 150
    • (2008) Biotechnol. Adv. , vol.26 , pp. 135-150
    • Yang, L.1    Bashir, R.2
  • 10
    • 0034818367 scopus 로고    scopus 로고
    • The detection of Salmonella serovars from animal feed and raw chicken using a combined immunomagnetic separation and ELISA method
    • L. P. Mansfield S. J. Forsythe The detection of Salmonella serovars from animal feed and raw chicken using a combined immunomagnetic separation and ELISA method Food Microbiol. 2001 18 4 361 366
    • (2001) Food Microbiol. , vol.18 , Issue.4 , pp. 361-366
    • Mansfield, L.P.1    Forsythe, S.J.2
  • 11
    • 0034630153 scopus 로고    scopus 로고
    • Molecular beacons: A real-time polymerase chain reaction assay for detecting Salmonella
    • W. Chen G. Martinez. A. Mulchandani Molecular beacons: a real-time polymerase chain reaction assay for detecting Salmonella Anal. Biochem. 2000 280 2 166 172
    • (2000) Anal. Biochem. , vol.280 , Issue.2 , pp. 166-172
    • Chen, W.1    Martinez, G.2    Mulchandani, A.3
  • 12
    • 84871502231 scopus 로고    scopus 로고
    • Successful Identification of Pathogens by Polymerase Chain Reaction (PCR)-Based Electron Spray Ionization Time-of-Flight Mass Spectrometry (ESI-TOF-MS) in Culture-Negative Periprosthetic Joint Infection
    • C. L. Jacovides R. Kreft B. S. Bahar Adeli B. Hozack G. D. Ehrlich J. Parvizi Successful Identification of Pathogens by Polymerase Chain Reaction (PCR)-Based Electron Spray Ionization Time-of-Flight Mass Spectrometry (ESI-TOF-MS) in Culture-Negative Periprosthetic Joint Infection J. Bone Jt. Surg. 2012 94 24 2247 2254
    • (2012) J. Bone Jt. Surg. , vol.94 , Issue.24 , pp. 2247-2254
    • Jacovides, C.L.1    Kreft, R.2    Bahar Adeli, B.S.3    Hozack, B.4    Ehrlich, G.D.5    Parvizi, J.6
  • 13
    • 78651395629 scopus 로고    scopus 로고
    • Detection of pathogens in foods: The current state-of-the-art and future directions
    • H. P. Dwivedi L. A. Jaykus Detection of pathogens in foods: the current state-of-the-art and future directions Crit. Rev. Microbiol. 2011 37 1 40 63
    • (2011) Crit. Rev. Microbiol. , vol.37 , Issue.1 , pp. 40-63
    • Dwivedi, H.P.1    Jaykus, L.A.2
  • 14
    • 50149098413 scopus 로고    scopus 로고
    • A PDMS microfluidic chip with nanostructures for bacteria concentration and fast detection
    • 272-275
    • J. J. Yu, L. D. Xiao and M. Yang, A PDMS microfluidic chip with nanostructures for bacteria concentration and fast detection, IEEE MEMS 2008 Conference, 2008, pp. 272-275
    • (2008) IEEE MEMS 2008 Conference
    • Yu, J.J.1    Xiao, L.D.2    Yang, M.3
  • 15
    • 33750385639 scopus 로고    scopus 로고
    • Quantitative and simultaneous detection of four foodborne bacterial pathogens with a multi-channel SPR sensor
    • A. D. Taylor J. Ladd Q. Yu S. Chen J. Homola S. Jiang Quantitative and simultaneous detection of four foodborne bacterial pathogens with a multi-channel SPR sensor Biosens. Bioelectron. 2006 22 752 758
    • (2006) Biosens. Bioelectron. , vol.22 , pp. 752-758
    • Taylor, A.D.1    Ladd, J.2    Yu, Q.3    Chen, S.4    Homola, J.5    Jiang, S.6
  • 16
    • 0345735487 scopus 로고    scopus 로고
    • A self-assembled monolayer-based piezoelectric immunosensor for rapid detection of Escherichia coli O157:H7
    • X. Su Y. Li A self-assembled monolayer-based piezoelectric immunosensor for rapid detection of Escherichia coli O157:H7 Biosens. Bioelectron. 2004 19 6 563 574
    • (2004) Biosens. Bioelectron. , vol.19 , Issue.6 , pp. 563-574
    • Su, X.1    Li, Y.2
  • 17
    • 33745699462 scopus 로고    scopus 로고
    • A micro-scale multi-frequency reactance measurement technique to detect bacterial growth at low bio-particle concentrations
    • S. Sengupta D. A. Battigelli H.-C. Chang A micro-scale multi-frequency reactance measurement technique to detect bacterial growth at low bio-particle concentrations Lab Chip 2006 5 682 692
    • (2006) Lab Chip , vol.5 , pp. 682-692
    • Sengupta, S.1    Battigelli, D.A.2    Chang, H.-C.3
  • 18
    • 27144548070 scopus 로고    scopus 로고
    • Impedance microbiology-on-a-chip: Microfluidic bioprocessor for rapid detection of bacterial metabolism
    • R. Gomez D. T. Morisette R. Bashir Impedance microbiology-on-a-chip: microfluidic bioprocessor for rapid detection of bacterial metabolism J. Microelectromech. Syst. 2005 14 829 838
    • (2005) J. Microelectromech. Syst. , vol.14 , pp. 829-838
    • Gomez, R.1    Morisette, D.T.2    Bashir, R.3
  • 19
    • 84864325687 scopus 로고    scopus 로고
    • Miniaturization through lab-on-a-chip: Utopia or reality for routine laboratories? A review
    • Á. Rios M. Zougaghb M. Avila Miniaturization through lab-on-a-chip: utopia or reality for routine laboratories? A review Anal. Chim. Acta 2012 740 1 11
    • (2012) Anal. Chim. Acta , vol.740 , pp. 1-11
    • Rios, Á.1    Zougaghb, M.2    Avila, M.3
  • 20
    • 84871647317 scopus 로고    scopus 로고
    • Electrochemical impedance spectroscopic technique with a functionalized microwire sensor for rapid detection of foodborne pathogens
    • L. Lu G. Chee K. Yamada S. Jun Electrochemical impedance spectroscopic technique with a functionalized microwire sensor for rapid detection of foodborne pathogens Biosens. Bioelectron. 2013 42 492 495
    • (2013) Biosens. Bioelectron. , vol.42 , pp. 492-495
    • Lu, L.1    Chee, G.2    Yamada, K.3    Jun, S.4
  • 21
    • 78650593740 scopus 로고    scopus 로고
    • Electrical detection of pathogenic bacteria via immobilized antimicrobial peptides
    • M. S. Mannoor S. Zhang A. J. Link M. C. McAlpine Electrical detection of pathogenic bacteria via immobilized antimicrobial peptides Proc. Natl. Acad. Sci. U. S. A. 2010 107 45 19207 19212
    • (2010) Proc. Natl. Acad. Sci. U. S. A. , vol.107 , Issue.45 , pp. 19207-19212
    • Mannoor, M.S.1    Zhang, S.2    Link, A.J.3    McAlpine, M.C.4
  • 22
    • 78049254897 scopus 로고    scopus 로고
    • A review on viral biosensors to detect human pathogens
    • R. L. Caygill G. E. Blair P. A. Millner A review on viral biosensors to detect human pathogens Anal. Chim. Acta 2010 681 1-2 8 15
    • (2010) Anal. Chim. Acta , vol.681 , Issue.12 , pp. 8-15
    • Caygill, R.L.1    Blair, G.E.2    Millner, P.A.3
  • 23
    • 79961052769 scopus 로고    scopus 로고
    • A Polymer-Based Electrochemical DNA Biosensor for Salmonella: Preparation, Characterization and Calibration
    • M. Díaz-Serrano A. Rosado J. delPilar M. Arias A. R. Guadalupe A Polymer-Based Electrochemical DNA Biosensor for Salmonella: Preparation, Characterization and Calibration Electroanalysis 2011 23 8 1830 1841
    • (2011) Electroanalysis , vol.23 , Issue.8 , pp. 1830-1841
    • Díaz-Serrano, M.1    Rosado, A.2    Delpilar, J.3    Arias, M.4    Guadalupe, A.R.5
  • 24
    • 84860523437 scopus 로고    scopus 로고
    • A quantitative study of detection mechanism of a label-free impedance biosensor using ultrananocrystalline diamond microelectrode array
    • S. Siddiqui Z. Dai C. J. Stavis H. Zeng N. Moldovan R. J. Hamers J. A. Carlisle P. U. Arumugam A quantitative study of detection mechanism of a label-free impedance biosensor using ultrananocrystalline diamond microelectrode array Biosens. Bioelectron. 2012 35 1 284 290
    • (2012) Biosens. Bioelectron. , vol.35 , Issue.1 , pp. 284-290
    • Siddiqui, S.1    Dai, Z.2    Stavis, C.J.3    Zeng, H.4    Moldovan, N.5    Hamers, R.J.6    Carlisle, J.A.7    Arumugam, P.U.8
  • 25
    • 84855710870 scopus 로고    scopus 로고
    • Functionalized gold nanoparticle supported sensory mechanisms applied in detection of chemical and biological threat agents: A review
    • V. K. K. Upadhyayula Functionalized gold nanoparticle supported sensory mechanisms applied in detection of chemical and biological threat agents: a review Anal. Chim. Acta 2012 715 1 18
    • (2012) Anal. Chim. Acta , vol.715 , pp. 1-18
    • Upadhyayula, V.K.K.1
  • 26
    • 79958785745 scopus 로고    scopus 로고
    • Genetic analysis of H1N1 influenza virus from throat swab samples in a microfluidic system for point-of-care diagnostics
    • B. S. Ferguson S. F. Buchsbaum T.-T. Wu K. Hsieh Y. Xiao R. Sun H. T. Soh Genetic analysis of H1N1 influenza virus from throat swab samples in a microfluidic system for point-of-care diagnostics J. Am. Chem. Soc. 2011 133 23 9129 9135
    • (2011) J. Am. Chem. Soc. , vol.133 , Issue.23 , pp. 9129-9135
    • Ferguson, B.S.1    Buchsbaum, S.F.2    Wu, T.-T.3    Hsieh, K.4    Xiao, Y.5    Sun, R.6    Soh, H.T.7
  • 27
    • 84871649242 scopus 로고    scopus 로고
    • An integrated solution for rapid biosensing with robust linker free covalent binding surfaces
    • Y. Yin M. M. M. Bilek K. Fisher C. Guo D. McKenzie An integrated solution for rapid biosensing with robust linker free covalent binding surfaces Biosens. Bioelectron. 2013 42 1 447 452
    • (2013) Biosens. Bioelectron. , vol.42 , Issue.1 , pp. 447-452
    • Yin, Y.1    Bilek, M.M.M.2    Fisher, K.3    Guo, C.4    McKenzie, D.5
  • 28
    • 84870826149 scopus 로고    scopus 로고
    • Development of a rapid low cost fluorescent biosensor for the detection of food contaminants
    • T. F. McGrath K. Andersson K. Campbell T. L. Fodey C. T. Elliott Development of a rapid low cost fluorescent biosensor for the detection of food contaminants Biosens. Bioelectron. 2013 41 1 96 102
    • (2013) Biosens. Bioelectron. , vol.41 , Issue.1 , pp. 96-102
    • McGrath, T.F.1    Andersson, K.2    Campbell, K.3    Fodey, T.L.4    Elliott, C.T.5
  • 31
    • 80053106655 scopus 로고    scopus 로고
    • Fluorescent europium-modified polymer nanoparticles for rapid and sensitive anthrax sensors
    • W.-K. Oh Y. S. Jeong J. Song J. Jang Fluorescent europium-modified polymer nanoparticles for rapid and sensitive anthrax sensors Biosens. Bioelectron. 2011 29 1 172 177
    • (2011) Biosens. Bioelectron. , vol.29 , Issue.1 , pp. 172-177
    • Oh, W.-K.1    Jeong, Y.S.2    Song, J.3    Jang, J.4
  • 32
    • 80755139520 scopus 로고    scopus 로고
    • A novel biosensor based on serum antibody immobilization for rapid detection of viral antigens
    • T. Q. Huy N. T. H. Hanh N. T. Thuy P. V. Chung P. T. Nga M. A. Tuan A novel biosensor based on serum antibody immobilization for rapid detection of viral antigens Talanta 2011 86 1 271 277
    • (2011) Talanta , vol.86 , Issue.1 , pp. 271-277
    • Huy, T.Q.1    Hanh, N.T.H.2    Thuy, N.T.3    Chung, P.V.4    Nga, P.T.5    Tuan, M.A.6
  • 33
    • 80155137448 scopus 로고    scopus 로고
    • A symmetric metamaterial element-based RF biosensor for rapid and label-free detection
    • H.-J. Lee J.-H. Lee H.-I. Jung A symmetric metamaterial element-based RF biosensor for rapid and label-free detection Appl. Phys. Lett. 2011 99 16 163703
    • (2011) Appl. Phys. Lett. , vol.99 , Issue.16 , pp. 163703
    • Lee, H.-J.1    Lee, J.-H.2    Jung, H.-I.3
  • 34
    • 58149170697 scopus 로고    scopus 로고
    • Fluorescent bio-barcode DNA assay for the detection of Salmonella enteric serovar enteritidis
    • D. Zhang D. J. Carr E. C. Alocilja Fluorescent bio-barcode DNA assay for the detection of Salmonella enteric serovar enteritidis Biosens. Bioelectron. 2009 24 5 1377 1381
    • (2009) Biosens. Bioelectron. , vol.24 , Issue.5 , pp. 1377-1381
    • Zhang, D.1    Carr, D.J.2    Alocilja, E.C.3
  • 35
    • 84855813503 scopus 로고    scopus 로고
    • Biosensing using dynamic-mode cantilever sensors: A review
    • B. N. Johnson R. Mutharasan Biosensing using dynamic-mode cantilever sensors: a review Biosens. Bioelectron. 2012 32 1 1 18
    • (2012) Biosens. Bioelectron. , vol.32 , Issue.1 , pp. 1-18
    • Johnson, B.N.1    Mutharasan, R.2
  • 36
    • 82555171680 scopus 로고    scopus 로고
    • Multi-material bio-fabrication of hydrogel cantilevers and actuators with stereolithography
    • V. Chan J. H. Jeong P. Bajaj M. Collens T. Saif H. Kong R. Bashir Multi-material bio-fabrication of hydrogel cantilevers and actuators with stereolithography Lab Chip 2012 12 1 88 98
    • (2012) Lab Chip , vol.12 , Issue.1 , pp. 88-98
    • Chan, V.1    Jeong, J.H.2    Bajaj, P.3    Collens, M.4    Saif, T.5    Kong, H.6    Bashir, R.7
  • 37
    • 80051489275 scopus 로고    scopus 로고
    • Cantilever array sensors detect specific carbohydrate-protein interactions with picomolar sensitivity
    • K. Gruber T. Horlacher R. Castelli A. Mader P. H. Seeberger B. A. Hermann Cantilever array sensors detect specific carbohydrate-protein interactions with picomolar sensitivity ACS Nano 2011 5 5 3670 3678
    • (2011) ACS Nano , vol.5 , Issue.5 , pp. 3670-3678
    • Gruber, K.1    Horlacher, T.2    Castelli, R.3    Mader, A.4    Seeberger, P.H.5    Hermann, B.A.6
  • 39
    • 84857448187 scopus 로고    scopus 로고
    • DNA thin film coated optical fiber biosensor
    • R. Amin A. Kulkarni T. Kim S. H. Park DNA thin film coated optical fiber biosensor Curr. Appl. Phys. 2012 12 3 841 845
    • (2012) Curr. Appl. Phys. , vol.12 , Issue.3 , pp. 841-845
    • Amin, R.1    Kulkarni, A.2    Kim, T.3    Park, S.H.4
  • 42
    • 84864390358 scopus 로고    scopus 로고
    • A piezoelectric immunosensor for specific capture and enrichment of viable pathogens by quartz crystal microbalance sensor, followed by detection with antibody-functionalized gold nanoparticles
    • X. Guo C.-S. Lin S.-H. Chen R. Ye V. C. H. Wu A piezoelectric immunosensor for specific capture and enrichment of viable pathogens by quartz crystal microbalance sensor, followed by detection with antibody-functionalized gold nanoparticles Biosens. Bioelectron. 2012 38 1 177 183
    • (2012) Biosens. Bioelectron. , vol.38 , Issue.1 , pp. 177-183
    • Guo, X.1    Lin, C.-S.2    Chen, S.-H.3    Ye, R.4    Wu, V.C.H.5
  • 43
    • 82555171694 scopus 로고    scopus 로고
    • Piezoelectric microelectromechanical resonant sensors for chemical and biological detection
    • W. Pang H. Zhao E. S. Kim H. Zhang H. Yu X. Hu Piezoelectric microelectromechanical resonant sensors for chemical and biological detection Lab Chip 2012 12 1 29 44
    • (2012) Lab Chip , vol.12 , Issue.1 , pp. 29-44
    • Pang, W.1    Zhao, H.2    Kim, E.S.3    Zhang, H.4    Yu, H.5    Hu, X.6
  • 45
    • 65949096098 scopus 로고    scopus 로고
    • Continuous particle separation by size via AC-dielectrophoresis using a lab-on-a-chip device with 3-D electrodes
    • B. Cetin Y. Kang Z. Wu D. Li Continuous particle separation by size via AC-dielectrophoresis using a lab-on-a-chip device with 3-D electrodes Electrophoresis 2009 30 5 766 772
    • (2009) Electrophoresis , vol.30 , Issue.5 , pp. 766-772
    • Cetin, B.1    Kang, Y.2    Wu, Z.3    Li, D.4
  • 46
    • 84862777346 scopus 로고    scopus 로고
    • Specific and targeted detection of viable Escherichia coli O157:H7using a sensitive and reusable impedance biosensor with dose and time response studies
    • M. Dweik R. C. Stringer S. Ghosh Dastider Y. Wu M. Almasri S. Barizuddin Specific and targeted detection of viable Escherichia coli O157:H7using a sensitive and reusable impedance biosensor with dose and time response studies Talanta 2012 94 84 89
    • (2012) Talanta , vol.94 , pp. 84-89
    • Dweik, M.1    Stringer, R.C.2    Ghosh Dastider, S.3    Wu, Y.4    Almasri, M.5    Barizuddin, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.