메뉴 건너뛰기




Volumn 18, Issue 8, 2015, Pages 1501-1514

Maximum wind power generation in a power system imposed by system inertia and primary reserve requirements

Author keywords

ancillary services; primary reserve; system inertia; wind power generation; wind power penetration

Indexed keywords

ELECTRIC POWER GENERATION;

EID: 84937163203     PISSN: 10954244     EISSN: 10991824     Source Type: Journal    
DOI: 10.1002/we.1773     Document Type: Article
Times cited : (24)

References (28)
  • 2
    • 34948878227 scopus 로고    scopus 로고
    • Field tests of wind turbines submitted to real voltage dips under the new Spanish grid code requirements
    • Gõmez E, Fuentes JA, Molina-García A, Ruz F, Jiménez F,. Field tests of wind turbines submitted to real voltage dips under the new Spanish grid code requirements. Wind Energy 2007; 10: 483-495.
    • (2007) Wind Energy , vol.10 , pp. 483-495
    • Gõmez, E.1    Fuentes, J.A.2    Molina-García, A.3    Ruz, F.4    Jiménez, F.5
  • 3
    • 84860222524 scopus 로고    scopus 로고
    • Review of international grid codes for wind power integration: Diversity, technology and a case for global standard
    • Mohseni M, Islam SM,. Review of international grid codes for wind power integration: diversity, technology and a case for global standard. Renewable and Sustainable Energy Reviews 2012; 16: 3876-3890.
    • (2012) Renewable and Sustainable Energy Reviews , vol.16 , pp. 3876-3890
    • Mohseni, M.1    Islam, S.M.2
  • 4
    • 70349579256 scopus 로고    scopus 로고
    • A review of grid code technical requirements for wind farms
    • Tsili M, Papathanassiou S,. A review of grid code technical requirements for wind farms. IET Renewable Power Generation 2009; 3: 308-332.
    • (2009) IET Renewable Power Generation , vol.3 , pp. 308-332
    • Tsili, M.1    Papathanassiou, S.2
  • 5
    • 10244250325 scopus 로고    scopus 로고
    • Comparison of the response of doubly fed and fixed-speed induction generator wind turbines to changes in network frequency
    • Ekanayake J, Jenkins N,. Comparison of the response of doubly fed and fixed-speed induction generator wind turbines to changes in network frequency. IEEE Transactions on Energy Conversion 2004; 19: 800-802.
    • (2004) IEEE Transactions on Energy Conversion , vol.19 , pp. 800-802
    • Ekanayake, J.1    Jenkins, N.2
  • 6
    • 67349262621 scopus 로고    scopus 로고
    • Dynamic contribution of DFIG-based wind plants to system frequency disturbances
    • Kayikci M, Milanovic JV,. Dynamic contribution of DFIG-based wind plants to system frequency disturbances. IEEE Transactions on Power Systems 2009; 24: 859-867.
    • (2009) IEEE Transactions on Power Systems , vol.24 , pp. 859-867
    • Kayikci, M.1    Milanovic, J.V.2
  • 9
    • 34548030937 scopus 로고    scopus 로고
    • Participation of doubly fed induction wind generators in system frequency regulation
    • de Almeida RG, Lopes JAP,. Participation of doubly fed induction wind generators in system frequency regulation. IEEE Transactions on Power Systems 2007; 22: 944-950.
    • (2007) IEEE Transactions on Power Systems , vol.22 , pp. 944-950
    • De Almeida, R.G.1    Lopes, J.A.P.2
  • 10
    • 55149102780 scopus 로고    scopus 로고
    • Experiment of a wind generator participation to frequency control
    • Courtecuisse V, Sprooten J, Robyns B, Deuse J,. Experiment of a wind generator participation to frequency control. EPE Journal 2008; 18: 14-24.
    • (2008) EPE Journal , vol.18 , pp. 14-24
    • Courtecuisse, V.1    Sprooten, J.2    Robyns, B.3    Deuse, J.4
  • 11
    • 70350716320 scopus 로고    scopus 로고
    • Wind farms with HVDC delivery in load frequency control
    • Fan L, Miao Z, Osborn D,. Wind farms with HVDC delivery in load frequency control. IEEE Transactions on Power Systems 2009; 24: 1894-1895.
    • (2009) IEEE Transactions on Power Systems , vol.24 , pp. 1894-1895
    • Fan, L.1    Miao, Z.2    Osborn, D.3
  • 14
    • 34748845857 scopus 로고    scopus 로고
    • Influence of wind turbine behaviour on the primary frequency control of the British transmission grid
    • Pearmine R, Song YH, Chebbo A,. Influence of wind turbine behaviour on the primary frequency control of the British transmission grid. IET Renewable Power Generation 2007; 1: 142-150.
    • (2007) IET Renewable Power Generation , vol.1 , pp. 142-150
    • Pearmine, R.1    Song, Y.H.2    Chebbo, A.3
  • 17
  • 18
    • 33947685476 scopus 로고    scopus 로고
    • Value of bulk energy storage for managing wind power fluctuations
    • Black M, Strbac G,. Value of bulk energy storage for managing wind power fluctuations. IEEE Transactions on Energy Conversion 2007; 22: 197-205.
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , pp. 197-205
    • Black, M.1    Strbac, G.2
  • 19
    • 60149087287 scopus 로고    scopus 로고
    • Estimating the spinning reserve requirements in systems with significant wind power generation penetration
    • Ortega-Vazquez M, Kirschen DS,. Estimating the spinning reserve requirements in systems with significant wind power generation penetration. IEEE Transactions on Power Systems 2009; 24: 114-124.
    • (2009) IEEE Transactions on Power Systems , vol.24 , pp. 114-124
    • Ortega-Vazquez, M.1    Kirschen, D.S.2
  • 22
    • 78650367251 scopus 로고    scopus 로고
    • Red Eléctrica de España - REE (Spanish TSO)
    • Red Eléctrica de España-REE (Spanish TSO). Electricity market data. 2010. Available: http://www.esios.ree.es.
    • (2010) Electricity Market Data
  • 26
    • 9244235532 scopus 로고    scopus 로고
    • A Monte-Carlo simulation method for setting the underfrequency load shedding relays and selecting the spinning reserve policy in autonomous power systems
    • Thalassinakis EJ, Dialynas EN,. A Monte-Carlo simulation method for setting the underfrequency load shedding relays and selecting the spinning reserve policy in autonomous power systems. IEEE Transactions on Power Systems 2004; 19: 2044.
    • (2004) IEEE Transactions on Power Systems , vol.19 , pp. 2044
    • Thalassinakis, E.J.1    Dialynas, E.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.