메뉴 건너뛰기




Volumn 45, Issue 7, 2015, Pages 1046-1055

Dose reduction in pediatric abdominal CT: use of iterative reconstruction techniques across different CT platforms

Author keywords

ALARA; Computed tomography; Dose reduction; Iterative reconstruction technique; Pediatric

Indexed keywords

ABDOMINAL MASS; ABDOMINAL PAIN; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; DUAL ENERGY COMPUTER ASSISTED TOMOGRAPHY; FEVER; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; INFLAMMATORY BOWEL DISEASE; LIVER INJURY; LYMPHADENOPATHY; NEPHROLITHIASIS; PEDIATRICS; PRIORITY JOURNAL; RADIATION DOSE; RADIATION DOSE REDUCTION; REVIEW; ABDOMINAL RADIOGRAPHY; ADOLESCENT; ALGORITHM; ARTIFACT; CHILD; COMPUTER ASSISTED DIAGNOSIS; FEMALE; IMAGE PROCESSING; INFANT; MALE; PRESCHOOL CHILD; PROCEDURES; REPRODUCIBILITY; THREE DIMENSIONAL IMAGING;

EID: 84933678845     PISSN: 03010449     EISSN: 14321998     Source Type: Journal    
DOI: 10.1007/s00247-014-3235-2     Document Type: Review
Times cited : (46)

References (21)
  • 1
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography — an increasing source of radiation exposure
    • COI: 1:CAS:528:DC%2BD2sXhsVSlurfF, PID: 18046031
    • Brenner DJ, Hall EJ (2007) Computed tomography — an increasing source of radiation exposure. N Engl J Med 357:2277–2284
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 2
    • 0036548719 scopus 로고    scopus 로고
    • (2002) The ALARA (as low as reasonably achievable) concept in pediatric CT intelligent dose reduction. Multidisciplinary conference organized by the Society of [stet] Pediatric Radiology. August 18–19, 2001. Pediatr Radiol 32:217–313
    • (2001) Pediatr Radiol , vol.32 , pp. 217-313
  • 3
    • 77950614409 scopus 로고    scopus 로고
    • Image gently: ten steps you can take to optimize image quality and lower CT dose for pediatric patients
    • PID: 20308484
    • Strauss KJ, Goske MJ, Kaste SC et al (2010) Image gently: ten steps you can take to optimize image quality and lower CT dose for pediatric patients. AJR Am J Roentgenol 194:868–873
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 868-873
    • Strauss, K.J.1    Goske, M.J.2    Kaste, S.C.3
  • 4
    • 84895459914 scopus 로고    scopus 로고
    • Techniques and tactics for optimizing CT dose in adults and children: state of the art and future advances
    • PID: 24589401
    • Lambert J, MacKenzie JD, Cody DD et al (2014) Techniques and tactics for optimizing CT dose in adults and children: state of the art and future advances. J Am Coll Radiol 11:262–266
    • (2014) J Am Coll Radiol , vol.11 , pp. 262-266
    • Lambert, J.1    MacKenzie, J.D.2    Cody, D.D.3
  • 5
    • 84255163675 scopus 로고    scopus 로고
    • CT dose reduction in practice
    • PID: 21847727
    • Callahan MJ (2011) CT dose reduction in practice. Pediatr Radiol 41:488–492
    • (2011) Pediatr Radiol , vol.41 , pp. 488-492
    • Callahan, M.J.1
  • 6
    • 84862490176 scopus 로고    scopus 로고
    • Radiation dose reduction with hybrid iterative reconstruction for pediatric CT
    • PID: 22517962
    • Singh S, Kalra MK, Shenoy-Bhangle AS et al (2012) Radiation dose reduction with hybrid iterative reconstruction for pediatric CT. Radiology 263:537–546
    • (2012) Radiology , vol.263 , pp. 537-546
    • Singh, S.1    Kalra, M.K.2    Shenoy-Bhangle, A.S.3
  • 7
    • 67650077358 scopus 로고    scopus 로고
    • Dose reduction and compliance with pediatric CT protocols adapted to patient size, clinical indication, and number of prior studies
    • PID: 19435938
    • Singh S, Kalra MK, Moore MA et al (2009) Dose reduction and compliance with pediatric CT protocols adapted to patient size, clinical indication, and number of prior studies. Radiology 252:200–208
    • (2009) Radiology , vol.252 , pp. 200-208
    • Singh, S.1    Kalra, M.K.2    Moore, M.A.3
  • 8
    • 84904732266 scopus 로고    scopus 로고
    • Computed tomography (CT) of the chest at less than 1 mSv: an ongoing prospective clinical trial of chest CT at submillisievert radiation doses with iterative model image reconstruction and iDose4 technique
    • PID: 24651746
    • Khawaja RD, Singh S, Gilman M et al (2014) Computed tomography (CT) of the chest at less than 1 mSv: an ongoing prospective clinical trial of chest CT at submillisievert radiation doses with iterative model image reconstruction and iDose4 technique. J Comput Assist Tomogr 38:613–619
    • (2014) J Comput Assist Tomogr , vol.38 , pp. 613-619
    • Khawaja, R.D.1    Singh, S.2    Gilman, M.3
  • 9
    • 84875431776 scopus 로고    scopus 로고
    • Noise-reducing algorithms do not necessarily provide superior dose optimisation for hepatic lesion detection with multidetector CT
    • COI: 1:STN:280:DC%2BC3szmsF2ntA%3D%3D, PID: 23392194
    • Dobeli KL, Lewis SJ, Meikle SR et al (2013) Noise-reducing algorithms do not necessarily provide superior dose optimisation for hepatic lesion detection with multidetector CT. Br J Radiol 86:20120500
    • (2013) Br J Radiol , vol.86 , pp. 20120500
    • Dobeli, K.L.1    Lewis, S.J.2    Meikle, S.R.3
  • 10
    • 84892742975 scopus 로고    scopus 로고
    • Hybrid iterative reconstruction technique for abdominal CT protocols in obese patients: assessment of image quality, radiation dose, and low-contrast detectability in a phantom
    • PID: 24450696
    • Schindera ST, Odedra D, Mercer D et al (2014) Hybrid iterative reconstruction technique for abdominal CT protocols in obese patients: assessment of image quality, radiation dose, and low-contrast detectability in a phantom. AJR Am J Roentgenol 202:W146–W152
    • (2014) AJR Am J Roentgenol , vol.202 , pp. 146-152
    • Schindera, S.T.1    Odedra, D.2    Mercer, D.3
  • 11
    • 84871698536 scopus 로고    scopus 로고
    • Filtered back projection, adaptive statistical iterative reconstruction, and a model-based iterative reconstruction in abdominal CT: an experimental clinical study
    • PID: 23169793
    • Deák Z, Grimm JM, Treitl M et al (2013) Filtered back projection, adaptive statistical iterative reconstruction, and a model-based iterative reconstruction in abdominal CT: an experimental clinical study. Radiology 266:197–206
    • (2013) Radiology , vol.266 , pp. 197-206
    • Deák, Z.1    Grimm, J.M.2    Treitl, M.3
  • 12
    • 84886661454 scopus 로고    scopus 로고
    • Model-based iterative reconstruction and adaptive statistical iterative reconstruction techniques in abdominal CT: comparison of image quality in the detection of colorectal liver metastases
    • PID: 23847252
    • Volders D, Bols A, Haspeslagh M et al (2013) Model-based iterative reconstruction and adaptive statistical iterative reconstruction techniques in abdominal CT: comparison of image quality in the detection of colorectal liver metastases. Radiology 269:469–474
    • (2013) Radiology , vol.269 , pp. 469-474
    • Volders, D.1    Bols, A.2    Haspeslagh, M.3
  • 13
    • 84891053369 scopus 로고    scopus 로고
    • Pediatric CT: implementation of ASIR for substantial radiation dose reduction while maintaining pre-ASIR image noise
    • PID: 23901128
    • Brady SL, Moore BM, Yee BS et al (2014) Pediatric CT: implementation of ASIR for substantial radiation dose reduction while maintaining pre-ASIR image noise. Radiology 270:223–231
    • (2014) Radiology , vol.270 , pp. 223-231
    • Brady, S.L.1    Moore, B.M.2    Yee, B.S.3
  • 14
    • 84893478586 scopus 로고    scopus 로고
    • Model-based iterative reconstruction: effect on patient radiation dose and image quality in pediatric body CT
    • PID: 24091359
    • Smith EA, Dillman JR, Goodsitt MM et al (2014) Model-based iterative reconstruction: effect on patient radiation dose and image quality in pediatric body CT. Radiology 270:526–534
    • (2014) Radiology , vol.270 , pp. 526-534
    • Smith, E.A.1    Dillman, J.R.2    Goodsitt, M.M.3
  • 15
    • 80052626817 scopus 로고    scopus 로고
    • Reducing abdominal CT radiation dose with the adaptive statistical iterative reconstruction technique in children: a feasibility study
    • PID: 21594551
    • Vorona GA, Ceschin RC, Clayton BL et al (2011) Reducing abdominal CT radiation dose with the adaptive statistical iterative reconstruction technique in children: a feasibility study. Pediatr Radiol 41:1174–1182
    • (2011) Pediatr Radiol , vol.41 , pp. 1174-1182
    • Vorona, G.A.1    Ceschin, R.C.2    Clayton, B.L.3
  • 16
    • 84866073350 scopus 로고    scopus 로고
    • Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: a pediatric oncology perspective
    • COI: 1:STN:280:DC%2BC38bltVWjtA%3D%3D, PID: 22957619
    • Brady SL, Yee BS, Kaufman RA (2012) Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: a pediatric oncology perspective. Med Phys 39:5520–5531
    • (2012) Med Phys , vol.39 , pp. 5520-5531
    • Brady, S.L.1    Yee, B.S.2    Kaufman, R.A.3
  • 17
    • 84892746588 scopus 로고    scopus 로고
    • Optimization of hybrid iterative reconstruction level in pediatric body CT
    • PID: 24450687
    • Karmazyn B, Liang Y, Ai H et al (2014) Optimization of hybrid iterative reconstruction level in pediatric body CT. AJR Am J Roentgenol 202:426–431
    • (2014) AJR Am J Roentgenol , vol.202 , pp. 426-431
    • Karmazyn, B.1    Liang, Y.2    Ai, H.3
  • 18
    • 80052615252 scopus 로고    scopus 로고
    • Paediatric cardiac CT examinations: impact of the iterative reconstruction method ASIR on image quality — preliminary findings
    • PID: 21717165
    • Miéville FA, Gudinchet F, Rizzo E et al (2011) Paediatric cardiac CT examinations: impact of the iterative reconstruction method ASIR on image quality — preliminary findings. Pediatr Radiol 41:1154–1164
    • (2011) Pediatr Radiol , vol.41 , pp. 1154-1164
    • Miéville, F.A.1    Gudinchet, F.2    Rizzo, E.3
  • 19
    • 84882275207 scopus 로고    scopus 로고
    • A prospective feasibility study of submillisievert abdominopelvic CT using iterative reconstruction in Crohn's disease
    • PID: 23740025
    • O’Neill SB, McLaughlin PD, Crush L et al (2013) A prospective feasibility study of submillisievert abdominopelvic CT using iterative reconstruction in Crohn's disease. Eur Radiol 23:2503–2512
    • (2013) Eur Radiol , vol.23 , pp. 2503-2512
    • O’Neill, S.B.1    McLaughlin, P.D.2    Crush, L.3
  • 20
    • 58149218228 scopus 로고    scopus 로고
    • CT with a computer-simulated dose reduction technique for detection of pediatric nephroureterolithiasis: comparison of standard and reduced radiation doses
    • PID: 19098193
    • Karmazyn B, Frush DP, Applegate KE et al (2009) CT with a computer-simulated dose reduction technique for detection of pediatric nephroureterolithiasis: comparison of standard and reduced radiation doses. AJR Am J Roentgenol 192:143–149
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 143-149
    • Karmazyn, B.1    Frush, D.P.2    Applegate, K.E.3
  • 21
    • 84884559428 scopus 로고    scopus 로고
    • Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi
    • PID: 23929357
    • Vardhanabhuti V, Ilyas S, Gutteridge C et al (2013) Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi. Insights Imaging 4:661–669
    • (2013) Insights Imaging , vol.4 , pp. 661-669
    • Vardhanabhuti, V.1    Ilyas, S.2    Gutteridge, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.