메뉴 건너뛰기




Volumn 202, Issue 2, 2014, Pages 426-431

Optimization of hybrid iterative reconstruction level in pediatric body CT

Author keywords

ALARA; CT; Iterative reconstruction; Noise level; Pediatric imaging

Indexed keywords

ADOLESCENT; ADULT; AORTA; ARTICLE; BODY WEIGHT; CHILD; COMPUTED TOMOGRAPHY SCANNER; FEMALE; FILTERED BACK PROJECTION; HUMAN; HYBRID ITERATIVE RECONSTRUCTION; IMAGE RECONSTRUCTION; INFANT; INTERMETHOD COMPARISON; LIVER; MAJOR CLINICAL STUDY; MALE; MUSCLE; NEWBORN; NOISE MEASUREMENT; NOISE REDUCTION; PRIORITY JOURNAL; RADIOLOGIST; RETROSPECTIVE STUDY; SUBCUTANEOUS FAT; WHOLE BODY CT;

EID: 84892746588     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.13.10721     Document Type: Article
Times cited : (18)

References (21)
  • 1
    • 73149113560 scopus 로고    scopus 로고
    • Projected cancer risks from computed tomographic scans performed in the United States in 2007
    • Berrington de González A, Mahesh M, Kim KP, et al. Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 2009; 169:2071-2077
    • (2009) Arch Intern Med , vol.169 , pp. 2071-2077
    • Berrington De González, A.1    Mahesh, M.2    Kim, K.P.3
  • 2
    • 67649641621 scopus 로고    scopus 로고
    • NCRP report no. 160: Ionizing radiation exposure of the population of the United States, medical exposure - Are we doing less with more, and is there a role for health physicists?
    • Schauer DA, Linton OW. NCRP report no. 160: ionizing radiation exposure of the population of the United States, medical exposure - are we doing less with more, and is there a role for health physicists? Health Phys 2009; 97:1-5
    • (2009) Health Phys , vol.97 , pp. 1-5
    • Schauer, D.A.1    Linton, O.W.2
  • 3
    • 0035139873 scopus 로고    scopus 로고
    • Estimated risks of radiation-induced fatal cancer from pediatric CT
    • Brenner D, Elliston C, Hall E, Berdon W. Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR 2001; 176:289-296
    • (2001) AJR , vol.176 , pp. 289-296
    • Brenner, D.1    Elliston, C.2    Hall, E.3    Berdon, W.4
  • 4
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography: An increasing source of radiation exposure
    • Brenner DJ, Hall EJ. Computed tomography: an increasing source of radiation exposure. N Engl J Med 2007; 357:2277-2284
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 5
    • 0141993779 scopus 로고    scopus 로고
    • Computed tomography and radiation risks: What pediatric health care providers should know
    • Frush DP, Donnelly LF, Rosen NS. Computed tomography and radiation risks: what pediatric health care providers should know. Pediatrics 2003; 112:951-957
    • (2003) Pediatrics , vol.112 , pp. 951-957
    • Frush, D.P.1    Donnelly, L.F.2    Rosen, N.S.3
  • 6
    • 84864776903 scopus 로고    scopus 로고
    • Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: A retrospective cohort study
    • Pearce MS, Salotti JA, Little MP, et al. Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet 2012; 380:499-505
    • (2012) Lancet , vol.380 , pp. 499-505
    • Pearce, M.S.1    Salotti, J.A.2    Little, M.P.3
  • 7
    • 74749087439 scopus 로고    scopus 로고
    • Innovations in CT dose reduction strategy: Application of the adaptive statistical iterative reconstruction algorithm
    • Silva AC, Lawder HJ, Hara A, Kujak J, Pavlicek W. Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. AJR 2010; 194:191-199
    • (2010) AJR , vol.194 , pp. 191-199
    • Silva, A.C.1    Lawder, H.J.2    Hara, A.3    Kujak, J.4    Pavlicek, W.5
  • 8
    • 80052615252 scopus 로고    scopus 로고
    • Paediatric cardiac CT examinations: Impact of the iterative reconstruction method ASIR on image quality - Preliminary findings
    • Miéville FA, Gudinchet F, Rizzo E, et al. Paediatric cardiac CT examinations: impact of the iterative reconstruction method ASIR on image quality - preliminary findings. Pediatr Radiol 2011; 41:1154-1164
    • (2011) Pediatr Radiol , vol.41 , pp. 1154-1164
    • Miéville, F.A.1    Gudinchet, F.2    Rizzo, E.3
  • 9
    • 84866073350 scopus 로고    scopus 로고
    • Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: A pediatric oncology perspective
    • Brady SL, Yee BS, Kaufman RA. Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: a pediatric oncology perspective. Med Phys 2012; 39:5520-5531
    • (2012) Med Phys , vol.39 , pp. 5520-5531
    • Brady, S.L.1    Yee, B.S.2    Kaufman, R.A.3
  • 10
    • 84862490176 scopus 로고    scopus 로고
    • Radiation dose reduction with hybrid iterative reconstruction for pediatric CT
    • Singh S, Kalra MK, Shenoy-Bhangle AS, et al. Radiation dose reduction with hybrid iterative reconstruction for pediatric CT. Radiology 2012; 263:537-546
    • (2012) Radiology , vol.263 , pp. 537-546
    • Singh, S.1    Kalra, M.K.2    Shenoy-Bhangle, A.S.3
  • 11
    • 84864656284 scopus 로고    scopus 로고
    • Radiation dose reduction with the adaptive statistical iterative reconstruction (ASIR) technique for chest CT in children: An intra-individual comparison
    • Lee SH, Kim MJ, Yoon CS, Lee MJ. Radiation dose reduction with the adaptive statistical iterative reconstruction (ASIR) technique for chest CT in children: an intra-individual comparison. Eur J Radiol 2012; 81:e938-e943
    • (2012) Eur J Radiol , vol.81
    • Lee, S.H.1    Kim, M.J.2    Yoon, C.S.3    Lee, M.J.4
  • 12
    • 84864341805 scopus 로고    scopus 로고
    • Low contrast agent and radiation dose protocol for hepatic dynamic CT of thin adults at 256-detector row CT: Effect of low tube voltage and hybrid iterative reconstruction algorithm on image quality
    • Nakaura T, Nakamura S, Maruyama N, et al. Low contrast agent and radiation dose protocol for hepatic dynamic CT of thin adults at 256-detector row CT: effect of low tube voltage and hybrid iterative reconstruction algorithm on image quality. Radiology 2012; 264:445-454
    • (2012) Radiology , vol.264 , pp. 445-454
    • Nakaura, T.1    Nakamura, S.2    Maruyama, N.3
  • 13
    • 69949096664 scopus 로고    scopus 로고
    • Iterative reconstruction technique for reducing body radiation dose at CT: Feasibility study
    • Hara AK, Paden RG, Silva AC, Kujak JL, Lawder HJ, Pavlicek W. Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR 2009; 193:764-771
    • (2009) AJR , vol.193 , pp. 764-771
    • Hara, A.K.1    Paden, R.G.2    Silva, A.C.3    Kujak, J.L.4    Lawder, H.J.5    Pavlicek, W.6
  • 14
    • 84860319410 scopus 로고    scopus 로고
    • A hybrid iterative reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography
    • Oda S, Utsunomiya D, Funama Y, et al. A hybrid iterative reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography. AJR 2012; 198:1126-1131
    • (2012) AJR , vol.198 , pp. 1126-1131
    • Oda, S.1    Utsunomiya, D.2    Funama, Y.3
  • 15
    • 77958569748 scopus 로고    scopus 로고
    • Abdominal CT: Comparison of adaptive statistical iterative and filtered back projection reconstruction techniques
    • Singh S, Kalra MK, Hsieh J, et al. Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques. Radiology 2010; 257:373-383
    • (2010) Radiology , vol.257 , pp. 373-383
    • Singh, S.1    Kalra, M.K.2    Hsieh, J.3
  • 16
    • 77954708865 scopus 로고    scopus 로고
    • Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: A pilot study
    • Flicek KT, Hara AK, Silva AC, Wu Q, Peter MB, Johnson CD. Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study. AJR 2010; 195:126-131
    • (2010) AJR , vol.195 , pp. 126-131
    • Flicek, K.T.1    Hara, A.K.2    Silva, A.C.3    Wu, Q.4    Peter, M.B.5    Johnson, C.D.6
  • 17
    • 77949865226 scopus 로고    scopus 로고
    • Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique
    • Prakash P, Kalra MK, Kambadakone AK, et al. Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique. Invest Radiol 2010; 45:202-210
    • (2010) Invest Radiol , vol.45 , pp. 202-210
    • Prakash, P.1    Kalra, M.K.2    Kambadakone, A.K.3
  • 18
    • 75349092506 scopus 로고    scopus 로고
    • Low-tube-voltage, high-tube-current multidetector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm - Initial clinical experience
    • Marin D, Nelson RC, Schindera ST, et al. Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm - initial clinical experience. Radiology 2010; 254:145-153
    • (2010) Radiology , vol.254 , pp. 145-153
    • Marin, D.1    Nelson, R.C.2    Schindera, S.T.3
  • 19
    • 82455199803 scopus 로고    scopus 로고
    • Philips Healthcare website. Published February Accessed September 26, 2013
    • 4 iterative reconstruction technique: white paper. Philips Healthcare website. http://acceptance.netforum.healthcare. philips.com/Clinical/global/Explore/White-Papers/CT/iDose4-iterative- reconstruction-technique. Published February 2011. Accessed September 26, 2013
    • (2011) 4 Iterative Reconstruction Technique: White Paper
    • Scibelli, A.1
  • 20
    • 84876036668 scopus 로고    scopus 로고
    • Image quality assessment of standard- and low-dose chest CT using filtered back projection, adaptive statistical iterative reconstruction, and novel model-based iterative reconstruction algorithms
    • Vardhanabhuti V, Loader RJ, Mitchell GR, Riordan RD, Roobottom CA. Image quality assessment of standard- and low-dose chest CT using filtered back projection, adaptive statistical iterative reconstruction, and novel model-based iterative reconstruction algorithms. AJR 2013; 200:545-552
    • (2013) AJR , vol.200 , pp. 545-552
    • Vardhanabhuti, V.1    Loader, R.J.2    Mitchell, G.R.3    Riordan, R.D.4    Roobottom, C.A.5
  • 21
    • 84876669811 scopus 로고    scopus 로고
    • Model-based iterative reconstruction in pediatric chest CT: Assessment of image quality in a prospective study of children with cystic fibrosis
    • Miéville FA, Berteloot L, Grandjean A, et al. Model-based iterative reconstruction in pediatric chest CT: assessment of image quality in a prospective study of children with cystic fibrosis. Pediatr Radiol 2013; 43:558-567
    • (2013) Pediatr Radiol , vol.43 , pp. 558-567
    • Miéville, F.A.1    Berteloot, L.2    Grandjean, A.3