메뉴 건너뛰기




Volumn 25, Issue 7, 2015, Pages 1883-1890

Thyroid doses and risk to paediatric patients undergoing neck CT examinations

Author keywords

Neck; Pediatrics; Radiation Dosage; Spiral Computed; Thyroid Gland; Tomography

Indexed keywords

ADOLESCENT; ARTICLE; CANCER INCIDENCE; CANCER RISK; CHILD; COMPUTER ASSISTED TOMOGRAPHY; DOSIMETRY; FEMALE; HUMAN; IMAGING PHANTOM; INFANT; MAJOR CLINICAL STUDY; MALE; NECK; NEWBORN; PRIORITY JOURNAL; RADIATION DOSE; RADIATION HAZARD; THYROID CANCER; THYROID GLAND; ADVERSE EFFECTS; AGE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRESCHOOL CHILD; PROCEDURES; RADIOGRAPHY; RADIOMETRY; RETROSPECTIVE STUDY; RISK; SECOND CERVICAL VERTEBRA; SEX DIFFERENCE; SOUTH CAROLINA; THYROID NEOPLASMS;

EID: 84930478008     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-015-3590-x     Document Type: Article
Times cited : (10)

References (24)
  • 1
    • 34548184941 scopus 로고    scopus 로고
    • Increasing utilization of computed tomography in the pediatric emergency department, 2000-2006
    • PID: 17505849
    • Broder J, Fordham LA, Warshauer DM (2007) Increasing utilization of computed tomography in the pediatric emergency department, 2000-2006. Emerg Radiol 14:227–232
    • (2007) Emerg Radiol , vol.14 , pp. 227-232
    • Broder, J.1    Fordham, L.A.2    Warshauer, D.M.3
  • 2
    • 70350452390 scopus 로고    scopus 로고
    • The utility of computed tomography as a screening tool for the evaluation of pediatric blunt chest trauma
    • PID: 19590303
    • Markel TA, Kumar R, Koontz NA, Scherer LR, Applegate KE (2009) The utility of computed tomography as a screening tool for the evaluation of pediatric blunt chest trauma. J Trauma 67:23–28
    • (2009) J Trauma , vol.67 , pp. 23-28
    • Markel, T.A.1    Kumar, R.2    Koontz, N.A.3    Scherer, L.R.4    Applegate, K.E.5
  • 3
    • 33847223095 scopus 로고    scopus 로고
    • Pediatric head trauma: changes in use of computed tomography in emergency departments in the United States over time
    • PID: 17145113
    • Blackwell CD, Gorelick M, Holmes JF, Bandyopadhyay S, Kuppermann N (2007) Pediatric head trauma: changes in use of computed tomography in emergency departments in the United States over time. Ann Emerg Med 49:320–324
    • (2007) Ann Emerg Med , vol.49 , pp. 320-324
    • Blackwell, C.D.1    Gorelick, M.2    Holmes, J.F.3    Bandyopadhyay, S.4    Kuppermann, N.5
  • 4
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography–an increasing source of radiation exposure
    • COI: 1:CAS:528:DC%2BD2sXhsVSlurfF, PID: 18046031
    • Brenner DJ, Hall EJ (2007) Computed tomography–an increasing source of radiation exposure. N Engl J Med 357:2277–2284
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 5
    • 84926469643 scopus 로고    scopus 로고
    • Paediatric computed tomography radiation dose: a review of the global dilemma
    • PID: 24578786
    • Almohiy H (2014) Paediatric computed tomography radiation dose: a review of the global dilemma. World J Radiol 6:1–6
    • (2014) World J Radiol , vol.6
    • Almohiy, H.1
  • 6
    • 0035139873 scopus 로고    scopus 로고
    • Estimated risks of radiation-induced fatal cancer from pediatric CT
    • COI: 1:STN:280:DC%2BD3M3isVWktg%3D%3D, PID: 11159059
    • Brenner D, Elliston C, Hall E, Berdon W (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol 176:289–296
    • (2001) AJR Am J Roentgenol , vol.176 , pp. 289-296
    • Brenner, D.1    Elliston, C.2    Hall, E.3    Berdon, W.4
  • 7
    • 84864776903 scopus 로고    scopus 로고
    • Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study
    • PID: 22681860
    • Pearce MS, Salotti JA, Little MP et al (2012) Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet 380:499–505
    • (2012) Lancet , vol.380 , pp. 499-505
    • Pearce, M.S.1    Salotti, J.A.2    Little, M.P.3
  • 8
    • 84878566679 scopus 로고    scopus 로고
    • Cancer risk in 680,000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians
    • PID: 23694687
    • Mathews JD, Forsythe AV, Brady Z et al (2013) Cancer risk in 680,000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians. BMJ 346:f2360
    • (2013) BMJ , vol.346 , pp. 2360
    • Mathews, J.D.1    Forsythe, A.V.2    Brady, Z.3
  • 10
    • 77954423240 scopus 로고    scopus 로고
    • Radiation dose evaluation in head and neck MDCT examinations with a 6-year-old child anthropomorphic phantom
    • PID: 20066408
    • Yamauchi-Kawaura C, Fujii K, Aoyama T, Koyama S, Yamauchi M (2010) Radiation dose evaluation in head and neck MDCT examinations with a 6-year-old child anthropomorphic phantom. Pediatr Radiol 40:1206–1214
    • (2010) Pediatr Radiol , vol.40 , pp. 1206-1214
    • Yamauchi-Kawaura, C.1    Fujii, K.2    Aoyama, T.3    Koyama, S.4    Yamauchi, M.5
  • 11
    • 38049107760 scopus 로고    scopus 로고
    • Comparison of head and body organ doses in CT
    • PID: 18184987
    • Huda W, Ogden KM (2008) Comparison of head and body organ doses in CT. Phys Med Biol 53:N9–N14
    • (2008) Phys Med Biol , vol.53 , pp. 9-14
    • Huda, W.1    Ogden, K.M.2
  • 12
    • 34548581922 scopus 로고    scopus 로고
    • Solid cancer incidence in atomic bomb survivors: 1958-1998
    • COI: 1:CAS:528:DC%2BD2sXntlyku7g%3D, PID: 17722996
    • Preston DL, Ron E, Tokuoka S et al (2007) Solid cancer incidence in atomic bomb survivors: 1958-1998. Radiat Res 168:1–64
    • (2007) Radiat Res , vol.168
    • Preston, D.L.1    Ron, E.2    Tokuoka, S.3
  • 13
    • 84884728949 scopus 로고    scopus 로고
    • Computation of thyroid doses and carcinogenic radiation risks to patients undergoing neck CT examinations
    • COI: 1:CAS:528:DC%2BC3sXhsFOgsLrN
    • Huda W, Spampinato MV, Tipnis SV, Magill D (2013) Computation of thyroid doses and carcinogenic radiation risks to patients undergoing neck CT examinations. Radiat Prot Dosim 156:436–444
    • (2013) Radiat Prot Dosim , vol.156 , pp. 436-444
    • Huda, W.1    Spampinato, M.V.2    Tipnis, S.V.3    Magill, D.4
  • 14
    • 79958794325 scopus 로고    scopus 로고
    • Technical note: estimating absorbed doses to the thyroid in CT
    • PID: 21815384
    • Huda W, Magill D, Spampinato MV (2011) Technical note: estimating absorbed doses to the thyroid in CT. Med Phys 38:3108–3113
    • (2011) Med Phys , vol.38 , pp. 3108-3113
    • Huda, W.1    Magill, D.2    Spampinato, M.V.3
  • 16
    • 0028963996 scopus 로고
    • Thyroid cancer after exposure to external radiation: a pooled analysis of seven studies
    • COI: 1:CAS:528:DyaK2MXjvFGlurw%3D, PID: 7871153
    • Ron E, Lubin JH, Shore RE et al (1995) Thyroid cancer after exposure to external radiation: a pooled analysis of seven studies. Radiat Res 141:259–277
    • (1995) Radiat Res , vol.141 , pp. 259-277
    • Ron, E.1    Lubin, J.H.2    Shore, R.E.3
  • 18
    • 84867954971 scopus 로고    scopus 로고
    • Size Specific Dose Estimates (SSDE) in pediatric and adult body CT examinations
    • College Park, MD
    • American Association of Physicists in Medicine (2011) Size Specific Dose Estimates (SSDE) in pediatric and adult body CT examinations. In: Report of the AAPM task group 204, College Park, MD.
    • (2011) Report of the AAPM task group , pp. 204
  • 20
    • 78649740074 scopus 로고    scopus 로고
    • Patient size and radiation exposure in thoracic, pelvic, and abdominal CT examinations performed with automatic exposure control
    • PID: 21098193
    • Israel GM, Cicchiello L, Brink J, Huda W (2010) Patient size and radiation exposure in thoracic, pelvic, and abdominal CT examinations performed with automatic exposure control. AJR Am J Roentgenol 195:1342–1346
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 1342-1346
    • Israel, G.M.1    Cicchiello, L.2    Brink, J.3    Huda, W.4
  • 23
    • 84862564263 scopus 로고    scopus 로고
    • Estimating thyroid dose in pediatric CT exams from surface dose measurement
    • PID: 22684053
    • Al-Senan R, Mueller DL, Hatab MR (2012) Estimating thyroid dose in pediatric CT exams from surface dose measurement. Phys Med Biol 57:4211–4221
    • (2012) Phys Med Biol , vol.57 , pp. 4211-4221
    • Al-Senan, R.1    Mueller, D.L.2    Hatab, M.R.3
  • 24
    • 34247891691 scopus 로고    scopus 로고
    • Thyroid dose from common head and neck CT examinations in children: is there an excess risk for thyroid cancer induction?
    • PID: 17021703
    • Mazonakis M, Tzedakis A, Damilakis J, Gourtsoyiannis N (2007) Thyroid dose from common head and neck CT examinations in children: is there an excess risk for thyroid cancer induction? Eur Radiol 17:1352–1357
    • (2007) Eur Radiol , vol.17 , pp. 1352-1357
    • Mazonakis, M.1    Tzedakis, A.2    Damilakis, J.3    Gourtsoyiannis, N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.