메뉴 건너뛰기




Volumn 40, Issue 7, 2010, Pages 1206-1214

Radiation dose evaluation in head and neck MDCT examinations with a 6-year-old child anthropomorphic phantom

Author keywords

Children; Dose; Head; MDCT; Neck

Indexed keywords

ANTHROPOMETRY; ARTICLE; BRAIN; CASE REPORT; CHILD; DOSE RESPONSE; DOSIMETER; FEMALE; HEAD; HUMAN; LENS; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; NECK; PHANTOM; PRESCHOOL CHILD; PRIORITY JOURNAL; RADIATION DOSE; THYROID GLAND; BODY BURDEN; COMPUTER ASSISTED TOMOGRAPHY; DEVICES; IMAGE QUALITY; PROCEDURES; RADIOGRAPHY; RADIOMETRY; RELATIVE BIOLOGIC EFFECTIVENESS;

EID: 77954423240     PISSN: 03010449     EISSN: 14321998     Source Type: Journal    
DOI: 10.1007/s00247-009-1495-z     Document Type: Article
Times cited : (15)

References (29)
  • 1
    • 0035139873 scopus 로고    scopus 로고
    • Estimated risks of radiation-induced fatal cancer from pediatric CT
    • 1:STN:280:DC%2BD3M3isVWktg%3D%3D 11159059
    • DJ Brenner CD Elliston EJ Hall, et al. 2001 Estimated risks of radiation-induced fatal cancer from pediatric CT AJR 176 289 296 1:STN:280:DC%2BD3M3isVWktg%3D%3D 11159059
    • (2001) AJR , vol.176 , pp. 289-296
    • Brenner, D.J.1    Elliston, C.D.2    Hall, E.J.3
  • 2
    • 33748110985 scopus 로고    scopus 로고
    • Organ and effective dose evaluation in diagnostic radiology based on in-phantom dose measurements with novel photodiode-dosemeters
    • DOI 10.1093/rpd/nci372
    • C Kawaura T Aoyama S Koyama, et al. 2006 Organ and effective dose evaluation in diagnostic radiology based on in-phantom dose measurements with novel photodiode-dosemeters Radiat Prot Dosimetry 118 421 430 10.1093/rpd/nci372 16439515 (Pubitemid 44304863)
    • (2006) Radiation Protection Dosimetry , vol.118 , Issue.4 , pp. 421-430
    • Kawaura, C.1    Aoyama, T.2    Koyama, S.3    Achiwa, M.4    Mori, M.5
  • 3
    • 0038480004 scopus 로고    scopus 로고
    • Survey of effective dose levels from typical paediatric CT protocols
    • DOI 10.1046/j.0004-8461.2003.01141.x
    • D McLean N Malitz S Lewis 2003 Survey of effective dose levels from typical pediatric CT protocols Australas Radiol 47 135 142 10.1046/j.0004-8461. 2003.01141.x 12780441 (Pubitemid 36783108)
    • (2003) Australasian Radiology , vol.47 , Issue.2 , pp. 135-142
    • McLean, D.1    Malitz, N.2    Lewis, S.3
  • 4
    • 0345392722 scopus 로고    scopus 로고
    • CT doses in children: A multicentre study
    • DOI 10.1259/bjr/92706933
    • J Pages N Buls M Osteaux 2003 CT doses in children: multicentre study Br J Radiol 76 803 811 10.1259/bjr/92706933 1:STN:280:DC%2BD3srktlKltA%3D%3D 14623782 (Pubitemid 37479339)
    • (2003) British Journal of Radiology , vol.76 , Issue.911 , pp. 803-811
    • Pages, J.1    Buls, N.2    Osteaux, M.3
  • 5
    • 26944442074 scopus 로고    scopus 로고
    • Current practice of pediatric MDCT in Japan: Survey results of demographics and age-based dose reduction
    • 16119782
    • O Miyazaki M Kitamura H Masaki, et al. 2005 Current practice of pediatric MDCT in Japan: survey results of demographics and age-based dose reduction Nippon Igaku Hoshasen Gakkai Zasshi 65 216 223 16119782
    • (2005) Nippon Igaku Hoshasen Gakkai Zasshi , vol.65 , pp. 216-223
    • Miyazaki, O.1    Kitamura, M.2    Masaki, H.3
  • 7
    • 49149102462 scopus 로고    scopus 로고
    • Pediatric body MDCT: A 5-year follow-up survey of scanning parameters used by pediatric radiologists
    • 10.2214/AJR.07.2989 18647940
    • ME Arch DP Frush 2008 Pediatric body MDCT: a 5-year follow-up survey of scanning parameters used by pediatric radiologists AJR 191 611 617 10.2214/AJR.07.2989 18647940
    • (2008) AJR , vol.191 , pp. 611-617
    • Arch, M.E.1    Frush, D.P.2
  • 8
    • 49049113873 scopus 로고    scopus 로고
    • CT radiation dose in children: A survey to establish age-based diagnostic reference levels in Switzerland
    • 10.1007/s00330-008-0963-4 18389242
    • FR Verdun D Gutierrez JP Vader, et al. 2008 CT radiation dose in children: a survey to establish age-based diagnostic reference levels in Switzerland Eur Radiol 18 1980 1986 10.1007/s00330-008-0963-4 18389242
    • (2008) Eur Radiol , vol.18 , pp. 1980-1986
    • Verdun, F.R.1    Gutierrez, D.2    Vader, J.P.3
  • 9
    • 65349161716 scopus 로고    scopus 로고
    • CT exposure from pediatric MDCT: Results from the 2007-2008 SFIPP/ISRN survey
    • 10.1016/S0221-0363(09)72471-0 1:STN:280:DC%2BD1M3ivVCqsA%3D%3D 19308005
    • HJ Brisse B Aubert 2009 CT exposure from pediatric MDCT: results from the 2007-2008 SFIPP/ISRN survey J Radiol 90 207 215 10.1016/S0221-0363(09)72471-0 1:STN:280:DC%2BD1M3ivVCqsA%3D%3D 19308005
    • (2009) J Radiol , vol.90 , pp. 207-215
    • Brisse, H.J.1    Aubert, B.2
  • 10
    • 59449094822 scopus 로고    scopus 로고
    • Effective dose estimation in whole-body multislice CT in paediatric trauma patients
    • 10.1007/s00247-008-1091-7 19148630
    • RD Munk PC Strohm U Saueressig, et al. 2009 Effective dose estimation in whole-body multislice CT in paediatric trauma patients Pediatr Radiol 39 245 252 10.1007/s00247-008-1091-7 19148630
    • (2009) Pediatr Radiol , vol.39 , pp. 245-252
    • Munk, R.D.1    Strohm, P.C.2    Saueressig, U.3
  • 11
    • 2942555605 scopus 로고    scopus 로고
    • Survey of CT practice in Japan and collective effective dose estimation
    • 15148792
    • K Nishizawa M Matsumoto K Iwai, et al. 2004 Survey of CT practice in Japan and collective effective dose estimation Nippon Igaku Hoshasen Gakkai Zasshi 64 151 158 15148792
    • (2004) Nippon Igaku Hoshasen Gakkai Zasshi , vol.64 , pp. 151-158
    • Nishizawa, K.1    Matsumoto, M.2    Iwai, K.3
  • 15
    • 33646663535 scopus 로고    scopus 로고
    • The basic data of materials for human body phantom
    • T Hiraoka 1999 The basic data of materials for human body phantom Iyou Hyoujun Senryou 4 23 28
    • (1999) Iyou Hyoujun Senryou , vol.4 , pp. 23-28
    • Hiraoka, T.1
  • 16
    • 34948891972 scopus 로고    scopus 로고
    • Comparative evaluation of organ and effective doses for paediatric patients with those for adults in chest and abdominal CT examinations
    • DOI 10.1259/bjr/97260522
    • K Fujii T Aoyama S Koyama, et al. 2007 Comparative evaluation of organ and effective doses for paediatric patients with those for adults in chest and abdominal CT examinations Br J Radiol 80 657 667 10.1259/bjr/97260522 1:STN:280:DC%2BD2srhtFCktw%3D%3D 17762056 (Pubitemid 47517811)
    • (2007) British Journal of Radiology , vol.80 , Issue.956 , pp. 657-667
    • Fujii, K.1    Aoyama, T.2    Koyama, S.3    Kawaura, C.4
  • 17
    • 77954426789 scopus 로고    scopus 로고
    • St George's Hospital, London, UK. Accessed 14 Sep 2009
    • ImPACT-CT patient dosimetry calculator version 1.0. (2009) http://www.impactscan.org. St George's Hospital, London, UK. Accessed 14 Sep 2009
    • (2009) ImPACT-CT Patient Dosimetry Calculator Version 1.0
  • 18
    • 33846529471 scopus 로고    scopus 로고
    • National survey of doses from CT in the UK: 2003
    • DOI 10.1259/bjr/93277434
    • PC Shrimpton MC Hillier MA Lewis, et al. 2006 National survey of doses from CT in the UK: 2003 Br J Radiol 79 968 980 10.1259/bjr/93277434 1:STN:280:DC%2BD2s%2Fhs1OksA%3D%3D 17213302 (Pubitemid 46157358)
    • (2006) British Journal of Radiology , vol.79 , Issue.948 , pp. 968-980
    • Shrimpton, P.C.1    Hillier, M.C.2    Lewis, M.A.3    Dunn, M.4
  • 19
    • 0036943614 scopus 로고    scopus 로고
    • Estimating cancer risks from pediatric CT: Going from the qualitative to the quantitative
    • DOI 10.1007/s00247-002-0671-1
    • DJ Brenner 2002 Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative Pediatr Radiol 32 228 231 10.1007/s00247-002- 0671-1 11956700 (Pubitemid 36075689)
    • (2002) Pediatric Radiology , vol.32 , Issue.4 , pp. 228-231
    • Brenner, D.J.1
  • 20
    • 0023097495 scopus 로고
    • Normalized pediatric organ-absorbed doses from CT examinations
    • 1:STN:280:DyaL2s%2FntlSnsw%3D%3D 3491508
    • T Fearon J Vucich 1987 Normalized pediatric organ-absorbed doses from CT examinations AJR 148 171 174 1:STN:280:DyaL2s%2FntlSnsw%3D%3D 3491508
    • (1987) AJR , vol.148 , pp. 171-174
    • Fearon, T.1    Vucich, J.2
  • 21
    • 34247891691 scopus 로고    scopus 로고
    • Thyroid dose from common head and neck CT examinations in children: Is there an excess risk for thyroid cancer induction?
    • DOI 10.1007/s00330-006-0417-9
    • M Mazonakis A Tzedakis J Damilakis, et al. 2007 Thyroid dose from common head and neck CT examinations in children: is there an excess risk for thyroid cancer induction? Eur Radiol 17 1352 1357 10.1007/s00330-006-0417-9 17021703 (Pubitemid 46691966)
    • (2007) European Radiology , vol.17 , Issue.5 , pp. 1352-1357
    • Mazonakis, M.1    Tzedakis, A.2    Damilakis, J.3    Gourtsoyiannis, N.4
  • 23
    • 71549173737 scopus 로고    scopus 로고
    • Radiation dose evaluation in 64-slice CT examinations with adult and pediatric anthropomorphic phantoms
    • Fujii K, Aoyama T, Yamauchi-Kawaura C et al (2009) Radiation dose evaluation in 64-slice CT examinations with adult and pediatric anthropomorphic phantoms. Br J Radiol 82:1010-1018
    • (2009) Br J Radiol , vol.82 , pp. 1010-1018
    • Fujii, K.1    Aoyama, T.2    Yamauchi-Kawaura, C.3
  • 25
    • 0036145023 scopus 로고    scopus 로고
    • Effective dose in paediatric computed tomography
    • DOI 10.1088/0031-9155/47/1/308, PII S0031915502258522
    • CL Chapple S Willis J Frame 2002 Effective dose in paediatric computed tomography Phys Med Biol 47 107 115 10.1088/0031-9155/47/1/308 1:STN:280:DC%2BD38%2FptFCisw%3D%3D 11820223 (Pubitemid 34071351)
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.1 , pp. 107-115
    • Chapple, C.-L.1    Willis, S.2    Frame, J.3
  • 27
    • 43149119002 scopus 로고    scopus 로고
    • Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: A simple estimation method
    • 10.1007/s00247-008-0794-0 18392817
    • KE Thomas B Wang 2008 Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method Pediatr Radiol 38 645 656 10.1007/s00247-008-0794-0 18392817
    • (2008) Pediatr Radiol , vol.38 , pp. 645-656
    • Thomas, K.E.1    Wang, B.2
  • 28
    • 84977453512 scopus 로고    scopus 로고
    • ICRP publication 73: Radiological protection and safety in medicine
    • ICRP. Elsevier Oxford
    • ICRP (1997) ICRP Publication 73: radiological protection and safety in medicine. Annals of the ICRP 261. Elsevier, Oxford
    • (1997) Annals of the ICRP 261
  • 29
    • 1642417360 scopus 로고    scopus 로고
    • Patient size and x-ray technique factors in head computed tomography examinations. I. Radiation doses
    • DOI 10.1118/1.1646232
    • W Huda KA Lieberman J Chang, et al. 2004 Patient size and x-ray technique factors in head computed tomography examinations. I. Radiation doses Med Phys 31 588 594 10.1118/1.1646232 15070258 (Pubitemid 38381022)
    • (2004) Medical Physics , vol.31 , Issue.3 , pp. 588-594
    • Huda, W.1    Lieberman, K.A.2    Chang, J.3    Roskopf, M.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.