메뉴 건너뛰기




Volumn 73, Issue 5, 2015, Pages 1885-1895

Reduction of respiratory motion artifacts for free-breathing whole-heart coronary MRA by weighted iterative reconstruction

Author keywords

compressed sensing; coronary magnetic resonance angiography; motion suppression; weighted iterative reconstruction

Indexed keywords

ANGIOGRAPHY; COMPRESSED SENSING; HEART; IMAGE QUALITY; MAGNETIC RESONANCE; MAGNETISM; NAVIGATION; RESPIRATORY MECHANICS;

EID: 84928089248     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.25321     Document Type: Article
Times cited : (39)

References (36)
  • 1
    • 0344305581 scopus 로고    scopus 로고
    • Whole-heart steady-state free precession coronary artery magnetic resonance angiography
    • Weber OM, Martin AJ, Higgins CB,. Whole-heart steady-state free precession coronary artery magnetic resonance angiography. Magn Reson Med 2003; 50: 1223-1228.
    • (2003) Magn Reson Med , vol.50 , pp. 1223-1228
    • Weber, O.M.1    Martin, A.J.2    Higgins, C.B.3
  • 2
    • 44449106094 scopus 로고    scopus 로고
    • The promise of whole-heart coronary MRI
    • Hauser TH, Manning WJ,. The promise of whole-heart coronary MRI. Curr Cardiol Rep 2008; 10: 46-50.
    • (2008) Curr Cardiol Rep , vol.10 , pp. 46-50
    • Hauser, T.H.1    Manning, W.J.2
  • 3
    • 0021958023 scopus 로고
    • MR image artifacts from periodic motion
    • Wood ML, Henkelman RM,. MR image artifacts from periodic motion. Med Phys 1985; 12: 143-151.
    • (1985) Med Phys , vol.12 , pp. 143-151
    • Wood, M.L.1    Henkelman, R.M.2
  • 5
    • 0032810872 scopus 로고    scopus 로고
    • Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: Comparison of navigator locations
    • Stuber M, Botnar RM, Danias PG, Kissinger KV, Manning WJ,. Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. Radiology 1999; 212: 579-587.
    • (1999) Radiology , vol.212 , pp. 579-587
    • Stuber, M.1    Botnar, R.M.2    Danias, P.G.3    Kissinger, K.V.4    Manning, W.J.5
  • 6
    • 0034874006 scopus 로고    scopus 로고
    • Free-breathing cardiac MR imaging: Study of implications of respiratory motion-initial results
    • Nehrke K, Börnert P, Manke D, Bock JC,. Free-breathing cardiac MR imaging: study of implications of respiratory motion-initial results. Radiology 2001; 220: 810-815.
    • (2001) Radiology , vol.220 , pp. 810-815
    • Nehrke, K.1    Börnert, P.2    Manke, D.3    Bock, J.C.4
  • 7
    • 22744432670 scopus 로고    scopus 로고
    • Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction
    • Stehning C, Börnert P, Nehrke K, Eggers H, Stuber M,. Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction. Magn Reson Med 2005; 54: 476-480.
    • (2005) Magn Reson Med , vol.54 , pp. 476-480
    • Stehning, C.1    Börnert, P.2    Nehrke, K.3    Eggers, H.4    Stuber, M.5
  • 8
    • 51449110126 scopus 로고    scopus 로고
    • A dual-projection respiratory self-gating technique for whole-heart coronary MRA
    • Lai P, Larson AC, Bi X, Jerecic R, Li D,. A dual-projection respiratory self-gating technique for whole-heart coronary MRA. J Magn Reson Imaging 2008; 28: 612-620.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 612-620
    • Lai, P.1    Larson, A.C.2    Bi, X.3    Jerecic, R.4    Li, D.5
  • 9
    • 84863843182 scopus 로고    scopus 로고
    • Respiratory self-navigation for whole-heart bright-blood coronary MRI: Methods for robust isolation and automatic segmentation of the blood pool
    • Piccini D, Littmann A, Nielles-Vallespin S, Zenge MO,. Respiratory self-navigation for whole-heart bright-blood coronary MRI: methods for robust isolation and automatic segmentation of the blood pool. Magn Reson Med 2012; 68: 571-579.
    • (2012) Magn Reson Med , vol.68 , pp. 571-579
    • Piccini, D.1    Littmann, A.2    Nielles-Vallespin, S.3    Zenge, M.O.4
  • 11
    • 27644559864 scopus 로고    scopus 로고
    • Prospective correction of affine motion for arbitrary MR sequences on a clinical scanner
    • Nehrke K, Börnert P,. Prospective correction of affine motion for arbitrary MR sequences on a clinical scanner. Magn Reson Med 2005; 54: 1130-1138.
    • (2005) Magn Reson Med , vol.54 , pp. 1130-1138
    • Nehrke, K.1    Börnert, P.2
  • 12
    • 84861227005 scopus 로고    scopus 로고
    • Improved least squares MR image reconstruction using estimates of k-space data consistency
    • Johnson KM, Block WF, Reeder SB, Samsonov A,. Improved least squares MR image reconstruction using estimates of k-space data consistency. Magn Reson Med 2012; 67: 1600-1608.
    • (2012) Magn Reson Med , vol.67 , pp. 1600-1608
    • Johnson, K.M.1    Block, W.F.2    Reeder, S.B.3    Samsonov, A.4
  • 13
    • 84928084048 scopus 로고    scopus 로고
    • Minimization of respiratory motion artifacts for whole-heart coronary MRI: A combination of self-navigation and weighted compressed sensing reconstruction
    • Melbourne, Australia, p
    • Forman C, Piccini D, Hutter J, Grimm R, Hornegger J, Zenge M O,. Minimization of respiratory motion artifacts for whole-heart coronary MRI: a combination of self-navigation and weighted compressed sensing reconstruction. In Proceedings of the 20th Annual Meeting of ISMRM, Melbourne, Australia, 2012. p. 1160.
    • (2012) Proceedings of the 20th Annual Meeting of ISMRM , pp. 1160
    • Forman, C.1    Piccini, D.2    Hutter, J.3    Grimm, R.4    Hornegger, J.5    Zenge, M.O.6
  • 17
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM,. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58: 1182-1195.
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 19
    • 84922362817 scopus 로고    scopus 로고
    • CS-SENSE or denoised SENSE: The influence of irregular sampling in l1 regularized SENSE reconstruction
    • Melbourne, Australia, p
    • Doneva M, Eggers H, Börnert P,. CS-SENSE or denoised SENSE: the influence of irregular sampling in l1 regularized SENSE reconstruction. In Proceedings of the 20th Annual Meeting of ISMRM, Melbourne, Australia, 2012. p. 2240.
    • (2012) Proceedings of the 20th Annual Meeting of ISMRM , pp. 2240
    • Doneva, M.1    Eggers, H.2    Börnert, P.3
  • 21
    • 84952315549 scopus 로고    scopus 로고
    • High-resolution 3D whole-heart coronary MRA: A study on the combination of data acquisition in multiple breath-holds and 1D residual respiratory motion compensation
    • in press
    • Forman C, Piccini D, Grimm R, Hutter J, Hornegger J, Zenge MO,. High-resolution 3D whole-heart coronary MRA: a study on the combination of data acquisition in multiple breath-holds and 1D residual respiratory motion compensation. Magn Reson Mater Phys Biol Med, in press.
    • Magn Reson Mater Phys Biol Med
    • Forman, C.1    Piccini, D.2    Grimm, R.3    Hutter, J.4    Hornegger, J.5    Zenge, M.O.6
  • 22
    • 84923175010 scopus 로고    scopus 로고
    • Highly efficient respiratory motion compensated free-breathing coronary MRA using golden-step Cartesian acquisition
    • Prieto C, Doneva M, Usman M, Henningsson M, Greil G, Schaeffter T, Botnar RM,. Highly efficient respiratory motion compensated free-breathing coronary MRA using golden-step Cartesian acquisition. J Magn Reson Imaging 2015; 41: 738-746.
    • (2015) J Magn Reson Imaging , vol.41 , pp. 738-746
    • Prieto, C.1    Doneva, M.2    Usman, M.3    Henningsson, M.4    Greil, G.5    Schaeffter, T.6    Botnar, R.M.7
  • 23
    • 79954608056 scopus 로고    scopus 로고
    • 3D radial sampling and 3D affine transform-based respiratory motion correction technique for free-breathing whole-heart coronary MRA with 100% imaging efficiency
    • Bhat H, Ge L, Nielles-Vallespin S, Zuehlsdorff S, Li D,. 3D radial sampling and 3D affine transform-based respiratory motion correction technique for free-breathing whole-heart coronary MRA with 100% imaging efficiency. Magn Reson Med 2011; 65: 1269-1277.
    • (2011) Magn Reson Med , vol.65 , pp. 1269-1277
    • Bhat, H.1    Ge, L.2    Nielles-Vallespin, S.3    Zuehlsdorff, S.4    Li, D.5
  • 24
    • 84890798070 scopus 로고    scopus 로고
    • Whole-heart coronary MRA with 100% respiratory gating efficiency: Self-navigated three-dimensional retrospective image-based motion correction (TRIM)
    • Pang J, Bhat H, Sharif B, Fan Z, Thomson LEJ, LaBounty T, Friedman JD, Min J, Berman DS, Li D,. Whole-heart coronary MRA with 100% respiratory gating efficiency: self-navigated three-dimensional retrospective image-based motion correction (TRIM). Magn Reson Med 2014; 71: 67-74.
    • (2014) Magn Reson Med , vol.71 , pp. 67-74
    • Pang, J.1    Bhat, H.2    Sharif, B.3    Fan, Z.4    Thomson, L.E.J.5    Labounty, T.6    Friedman, J.D.7    Min, J.8    Berman, D.S.9    Li, D.10
  • 25
    • 44049111982 scopus 로고
    • Nonlinear total variation based noise removal algorithms
    • Rudin LI, Osher S, Fatemi E,. Nonlinear total variation based noise removal algorithms. Phys D 1992; 60: 259-268.
    • (1992) Phys D , vol.60 , pp. 259-268
    • Rudin, L.I.1    Osher, S.2    Fatemi, E.3
  • 26
    • 0028929929 scopus 로고
    • Respiratory motion of the heart: Kinematics and the implications for the spatial resolution in coronary imaging
    • Wang Y, Riederer S J, Ehman RL,. Respiratory motion of the heart: kinematics and the implications for the spatial resolution in coronary imaging. Magn Reson Med 1995; 33: 713-719.
    • (1995) Magn Reson Med , vol.33 , pp. 713-719
    • Wang, Y.1    Riederer, J.S.2    Ehman, R.L.3
  • 27
    • 84966262179 scopus 로고
    • Updating quasi-Newton matrices with limited storage
    • Nocedal J,. Updating quasi-Newton matrices with limited storage. Math Comput 1980; 35: 773-782.
    • (1980) Math Comput , vol.35 , pp. 773-782
    • Nocedal, J.1
  • 28
    • 0035084261 scopus 로고    scopus 로고
    • Coronary arteries: Magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography
    • Li D, Carr JC, Shea SM, Zheng J, Deshpande VS, Wielopolski PA, Finn JP,. Coronary arteries: magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography. Radiology 2001; 219: 270-277.
    • (2001) Radiology , vol.219 , pp. 270-277
    • Li, D.1    Carr, J.C.2    Shea, S.M.3    Zheng, J.4    Deshpande, V.S.5    Wielopolski, P.A.6    Finn, J.P.7
  • 29
    • 84893474049 scopus 로고    scopus 로고
    • Respiratory self-navigated postcontrast whole-heart coronary MR angiography: Initial experience in patients
    • Piccini D, Monney P, Sierro C, et al. Respiratory self-navigated postcontrast whole-heart coronary MR angiography: initial experience in patients. Radiology 2014; 270: 378-386.
    • (2014) Radiology , vol.270 , pp. 378-386
    • Piccini, D.1    Monney, P.2    Sierro, C.3
  • 32
    • 46849091615 scopus 로고    scopus 로고
    • Generalized reconstruction by inversion of coupled systems (GRICS) applied to free-breathing MRI
    • Odille F, Vuissoz P-A, Marie P-Y, Felblinger J,. Generalized reconstruction by inversion of coupled systems (GRICS) applied to free-breathing MRI. Magn Reson Med 2008; 60: 146-157.
    • (2008) Magn Reson Med , vol.60 , pp. 146-157
    • Odille, F.1    Vuissoz, P.-A.2    Marie, P.-Y.3    Felblinger, J.4
  • 33
    • 81355161604 scopus 로고    scopus 로고
    • Nonrigid retrospective respiratory motion correction in whole-heart coronary MRA
    • Schmidt JFM, Buehrer M, Boesiger P, Kozerke S,. Nonrigid retrospective respiratory motion correction in whole-heart coronary MRA. Magn Reson Med 2011; 66: 1541-1549.
    • (2011) Magn Reson Med , vol.66 , pp. 1541-1549
    • Schmidt, J.F.M.1    Buehrer, M.2    Boesiger, P.3    Kozerke, S.4
  • 34
    • 34249017511 scopus 로고    scopus 로고
    • K-t SPARSE: High frame rate dynamic MRI exploiting spatio-temporal sparsity
    • Seattle, Washington, USA, p
    • Lustig M, Santos JM, Donoho DL,. k-t SPARSE: high frame rate dynamic MRI exploiting spatio-temporal sparsity. In Proceedings of the 13th Annual Meeting of ISMRM, Seattle, Washington, USA, 2006. p. 2420.
    • (2006) Proceedings of the 13th Annual Meeting of ISMRM , pp. 2420
    • Lustig, M.1    Santos, J.M.2    Donoho, D.L.3
  • 35
    • 84923186673 scopus 로고    scopus 로고
    • Low-rank plus sparse matrix decomposition for accelerated dynamic MRI with separation of background and dynamic components
    • Otazo R, Candes E, Sodickson DK,. Low-rank plus sparse matrix decomposition for accelerated dynamic MRI with separation of background and dynamic components. Magn Reson Med 2015; 73: 1125-1136.
    • (2015) Magn Reson Med , vol.73 , pp. 1125-1136
    • Otazo, R.1    Candes, E.2    Sodickson, D.K.3
  • 36
    • 84921439398 scopus 로고    scopus 로고
    • Accelerating parameter mapping with a locally low-rank constraint
    • Zhang T, Pauly JM, Levesque IR,. Accelerating parameter mapping with a locally low-rank constraint. Magn Reson Med 2015; 73: 655-661.
    • (2015) Magn Reson Med , vol.73 , pp. 655-661
    • Zhang, T.1    Pauly, J.M.2    Levesque, I.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.