메뉴 건너뛰기




Volumn 27, Issue 5, 2014, Pages 435-443

High-resolution 3D whole-heart coronary MRA: a study on the combination of data acquisition in multiple breath-holds and 1D residual respiratory motion compensation

Author keywords

Compressed sensing; Coronary magnetic resonance angiography; Multiple breath holds; Respiratory motion compensation

Indexed keywords

ANATOMY AND HISTOLOGY; CARDIAC GATED IMAGING; HEART; HUMAN; IMAGE ENHANCEMENT; IMAGE PROCESSING; MAGNETIC RESONANCE ANGIOGRAPHY; MOVEMENT (PHYSIOLOGY); NORMAL HUMAN; PROCEDURES; RESPIRATORY GATED IMAGING; THREE DIMENSIONAL IMAGING;

EID: 84952315549     PISSN: 09685243     EISSN: 13528661     Source Type: Journal    
DOI: 10.1007/s10334-013-0428-x     Document Type: Article
Times cited : (32)

References (35)
  • 2
    • 0344305581 scopus 로고    scopus 로고
    • Whole-heart steady-state free precession coronary artery magnetic resonance angiography
    • PID: 14648570
    • Weber OM, Martin AJ, Higgins CB (2003) Whole-heart steady-state free precession coronary artery magnetic resonance angiography. Magn Reson Med 50:1223–1228
    • (2003) Magn Reson Med , vol.50 , pp. 1223-1228
    • Weber, O.M.1    Martin, A.J.2    Higgins, C.B.3
  • 3
    • 44449106094 scopus 로고    scopus 로고
    • The promise of whole-heart coronary MRI
    • PID: 18417001
    • Hauser TH, Manning WJ (2008) The promise of whole-heart coronary MRI. Curr Cardiol Rep 10:46–50
    • (2008) Curr Cardiol Rep , vol.10 , pp. 46-50
    • Hauser, T.H.1    Manning, W.J.2
  • 4
    • 0030977431 scopus 로고    scopus 로고
    • Prospective navigator correction of image position for coronary MR angiography
    • PID: 9169696, COI: 1:STN:280:DyaK2szhtlSqsA%3D%3D
    • Danias PG, McConnell MV, Khasgiwala VC, Chuang ML, Edelman RR, Manning WJ (1997) Prospective navigator correction of image position for coronary MR angiography. Radiology 203:733–736
    • (1997) Radiology , vol.203 , pp. 733-736
    • Danias, P.G.1    McConnell, M.V.2    Khasgiwala, V.C.3    Chuang, M.L.4    Edelman, R.R.5    Manning, W.J.6
  • 5
    • 0032810872 scopus 로고    scopus 로고
    • Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations
    • PID: 10429721, COI: 1:STN:280:DyaK1MzlvVemsA%3D%3D
    • Stuber M, Botnar RM, Danias PG, Kissinger KV, Manning WJ (1999) Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. Radiology 212:579–587
    • (1999) Radiology , vol.212 , pp. 579-587
    • Stuber, M.1    Botnar, R.M.2    Danias, P.G.3    Kissinger, K.V.4    Manning, W.J.5
  • 6
    • 22744432670 scopus 로고    scopus 로고
    • Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction
    • PID: 16032682, COI: 1:STN:280:DC%2BD2MzotlWjtg%3D%3D
    • Stehning C, Börnert P, Nehrke K, Eggers H, Stuber M (2005) Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction. Magn Reson Med 54:476–480
    • (2005) Magn Reson Med , vol.54 , pp. 476-480
    • Stehning, C.1    Börnert, P.2    Nehrke, K.3    Eggers, H.4    Stuber, M.5
  • 7
    • 84863843182 scopus 로고    scopus 로고
    • Respiratory self-navigation for whole-heart bright-blood coronary MRI: methods for robust isolation and automatic segmentation of the blood pool
    • PID: 22213169
    • Piccini D, Littmann A, Nielles-Vallespin S, Zenge MO (2012) Respiratory self-navigation for whole-heart bright-blood coronary MRI: methods for robust isolation and automatic segmentation of the blood pool. Magn Reson Med 68:571–579
    • (2012) Magn Reson Med , vol.68 , pp. 571-579
    • Piccini, D.1    Littmann, A.2    Nielles-Vallespin, S.3    Zenge, M.O.4
  • 8
    • 0034874006 scopus 로고    scopus 로고
    • Free-breathing cardiac MR imaging: study of implications of respiratory motion—initial results
    • PID: 11526286, COI: 1:STN:280:DC%2BD3MvotlansQ%3D%3D
    • Nehrke K, Börnert P, Manke P, Böck JC (2001) Free-breathing cardiac MR imaging: study of implications of respiratory motion—initial results. Radiology 220:810–815
    • (2001) Radiology , vol.220 , pp. 810-815
    • Nehrke, K.1    Börnert, P.2    Manke, P.3    Böck, J.C.4
  • 9
    • 0027395731 scopus 로고
    • Fat-suppressed breath-hold magnetic resonance coronary angiography
    • PID: 8419029, COI: 1:STN:280:DyaK3s7itFGhsQ%3D%3D
    • Manning WJ, Li W, Boyle NG, Edelman RR (1993) Fat-suppressed breath-hold magnetic resonance coronary angiography. Circulation 87:94–104
    • (1993) Circulation , vol.87 , pp. 94-104
    • Manning, W.J.1    Li, W.2    Boyle, N.G.3    Edelman, R.R.4
  • 10
    • 4344647591 scopus 로고    scopus 로고
    • 3D breath-held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI
    • PID: 15332248
    • Peters DC, Ennis DB, Rohatgi P, Syed MA, McVeigh ER, Arai AE (2004) 3D breath-held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI. JMRI 20:411–416
    • (2004) JMRI , vol.20 , pp. 411-416
    • Peters, D.C.1    Ennis, D.B.2    Rohatgi, P.3    Syed, M.A.4    McVeigh, E.R.5    Arai, A.E.6
  • 12
    • 33645114985 scopus 로고    scopus 로고
    • Coronary MR imaging: breath-hold capability and patterns, coronary artery rest periods, and β-blocker use
    • PID: 16493014
    • Jahnke C, Paetsch I, Achenbach S, Schnackenburg B, Gebker R, Fleck E, Nagel E (2006) Coronary MR imaging: breath-hold capability and patterns, coronary artery rest periods, and β-blocker use. Radiology 239(1):71–78
    • (2006) Radiology , vol.239 , Issue.1 , pp. 71-78
    • Jahnke, C.1    Paetsch, I.2    Achenbach, S.3    Schnackenburg, B.4    Gebker, R.5    Fleck, E.6    Nagel, E.7
  • 15
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: the application of compressed sensing for rapid MR imaging
    • PID: 17969013
    • Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182–1195
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 17
    • 34250320137 scopus 로고    scopus 로고
    • Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint
    • PID: 17534903
    • Block KT, Uecker M, Frahm J (2007) Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint. Magn Reson Med 57:1086–1098
    • (2007) Magn Reson Med , vol.57 , pp. 1086-1098
    • Block, K.T.1    Uecker, M.2    Frahm, J.3
  • 19
    • 0037925300 scopus 로고    scopus 로고
    • Centering the projection reconstruction trajectory: reducing gradient delay errors
    • PID: 12815671
    • Peters DC, Derbyshire JA, McVeigh ER (2003) Centering the projection reconstruction trajectory: reducing gradient delay errors. Magn Reson Med 50(1):1–6
    • (2003) Magn Reson Med , vol.50 , Issue.1 , pp. 1-6
    • Peters, D.C.1    Derbyshire, J.A.2    McVeigh, E.R.3
  • 22
    • 0026219520 scopus 로고
    • Selection of a convolution function for Fourier inversion using gridding
    • PID: 18222850, COI: 1:STN:280:DC%2BD1c%2Fmslyitg%3D%3D
    • Jackson JI, Meyer CH, Nishimura DG, Macovski A (1991) Selection of a convolution function for Fourier inversion using gridding. IEEE Trans Med Imaging 10:473–478
    • (1991) IEEE Trans Med Imaging , vol.10 , pp. 473-478
    • Jackson, J.I.1    Meyer, C.H.2    Nishimura, D.G.3    Macovski, A.4
  • 25
    • 0006450384 scopus 로고
    • A better way to construct the sunflower head
    • Vogel H (1979) A better way to construct the sunflower head. Math Biosci 44:179–189
    • (1979) Math Biosci , vol.44 , pp. 179-189
    • Vogel, H.1
  • 28
    • 80052969467 scopus 로고    scopus 로고
    • Spiral phyllotaxis: the natural way to construct a 3D radial trajectory in MRI
    • PID: 21469185
    • Piccini D, Littmann A, Nielles-Vallespin S, Zenge MO (2011) Spiral phyllotaxis: the natural way to construct a 3D radial trajectory in MRI. Magn Reson Med 66:1049–1056
    • (2011) Magn Reson Med , vol.66 , pp. 1049-1056
    • Piccini, D.1    Littmann, A.2    Nielles-Vallespin, S.3    Zenge, M.O.4
  • 29
    • 0028929929 scopus 로고
    • Respiratory motion of the heart: kinematics and the implications for the spatial resolution in coronary imaging
    • PID: 7596276, COI: 1:STN:280:DyaK2MzhvFeitA%3D%3D
    • Wang Y, Riederer SJ, Ehman RL (1995) Respiratory motion of the heart: kinematics and the implications for the spatial resolution in coronary imaging. Magn Reson Med 33:713–719
    • (1995) Magn Reson Med , vol.33 , pp. 713-719
    • Wang, Y.1    Riederer, S.J.2    Ehman, R.L.3
  • 30
    • 44049111982 scopus 로고
    • Nonlinear total variation based noise removal algorithms
    • Rudin LI, Osher S, Fatemi E (1992) Nonlinear total variation based noise removal algorithms. Physica D 60:259–268
    • (1992) Physica D , vol.60 , pp. 259-268
    • Rudin, L.I.1    Osher, S.2    Fatemi, E.3
  • 31
    • 84966262179 scopus 로고
    • Updating quasi-Newton matrices with limited storage
    • Nocedal J (1980) Updating quasi-Newton matrices with limited storage. Math Comput 35:773–782
    • (1980) Math Comput , vol.35 , pp. 773-782
    • Nocedal, J.1
  • 32
    • 0035084261 scopus 로고    scopus 로고
    • Coronary arteries: magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography
    • PID: 11274569, COI: 1:STN:280:DC%2BD3M7oslKntw%3D%3D
    • Li D, Carr JC, Shea SM, Zheng J, Deshpande VS, Wielopolski PA, Finn JP (2001) Coronary arteries: magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography. Radiology 219:270–277
    • (2001) Radiology , vol.219 , pp. 270-277
    • Li, D.1    Carr, J.C.2    Shea, S.M.3    Zheng, J.4    Deshpande, V.S.5    Wielopolski, P.A.6    Finn, J.P.7
  • 33
    • 84872972575 scopus 로고    scopus 로고
    • Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator
    • PID: 22529009
    • Henningsson M, Smink J, Razavi R, Botnar RM (2013) Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator. Magn Reson Med 69:486–494
    • (2013) Magn Reson Med , vol.69 , pp. 486-494
    • Henningsson, M.1    Smink, J.2    Razavi, R.3    Botnar, R.M.4
  • 34
    • 81355161604 scopus 로고    scopus 로고
    • Nonrigid retrospective respiratory motion correction in whole-heart coronary MRA
    • PID: 21604297
    • Schmidt JFM, Buehrer M, Boesiger P, Kozerke S (2011) Nonrigid retrospective respiratory motion correction in whole-heart coronary MRA. Magn Reson Med 66:1541–1549
    • (2011) Magn Reson Med , vol.66 , pp. 1541-1549
    • Schmidt, J.F.M.1    Buehrer, M.2    Boesiger, P.3    Kozerke, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.