Volumn 41, Issue 2, 2015, Pages 460-473

Fast pediatric 3D free-breathing abdominal dynamic contrast enhanced MRI with high spatiotemporal resolution

Author keywords

Compressed sensing; Low rank; Parallel imaging; Pediatric dynamic contrast enhanced abdominal MRI

Indexed keywords

GADOBENATE DIMEGLUMINE; GADOBUTROL; GADOFOSVESET; GADOXETIC ACID; CONTRAST MEDIUM;

EID: 84921827528     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.24551     Document Type: Article
Times cited : (94)

References (43)
  • 1
    • 43549096651 scopus 로고    scopus 로고
    • Imaging of abdominal tumours: CT or MRI?
    • Olsen OE. Imaging of abdominal tumours: CT or MRI? Pediatr Radiol 2008;38(Suppl 3):452-458.
    • (2008) Pediatr Radiol , vol.38 , pp. 452-458
    • Olsen, O.E.1
  • 2
    • 80053055766 scopus 로고    scopus 로고
    • MR imaging of the abdomen and pelvis in infants, children, and adolescents
    • Darge K, Anupindi SA, Jaramillo D. MR imaging of the abdomen and pelvis in infants, children, and adolescents. Radiology 2011;261:12-29.
    • (2011) Radiology , vol.261 , pp. 12-29
    • Darge, K.1    Anupindi, S.A.2    Jaramillo, D.3
  • 3
    • 84856463074 scopus 로고    scopus 로고
    • Advances in pediatric body MRI
    • Vasanawala SS, Lustig M. Advances in pediatric body MRI. Pediatr Radiol 2011;41(Suppl 2):549-554.
    • (2011) Pediatr Radiol , vol.41 , pp. 549-554
    • Vasanawala, S.S.1    Lustig, M.2
  • 4
    • 33644820150 scopus 로고    scopus 로고
    • Dynamic contrast-enhanced MR urography in the evaluation of pediatric hydronephrosis: Part 1. Functional assessment
    • Jones RA, Easley K, Little SB, Scherz H, Kirsch AJ, Grattan-Smith JD. Dynamic contrast-enhanced MR urography in the evaluation of pediatric hydronephrosis: Part 1. Functional assessment. AJR AM J Roentgenol 2005;185:1598-1607.
    • (2005) AJR AM J Roentgenol , vol.185 , pp. 1598-1607
    • Jones, R.A.1    Easley, K.2    Little, S.B.3    Scherz, H.4    Kirsch, A.J.5    Grattan-Smith, J.D.6
  • 6
    • 37249046527 scopus 로고    scopus 로고
    • Deep sedation and minimal anesthesia
    • Sury MR, Smith JH. Deep sedation and minimal anesthesia. Paediatr Anaesth 2008;18:18-24.
    • (2008) Paediatr Anaesth , vol.18 , pp. 18-24
    • Sury, M.R.1    Smith, J.H.2
  • 8
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002;47:1202-1210.
    • (2002) Magn Reson Med , vol.47 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 9
    • 77955102061 scopus 로고    scopus 로고
    • SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space
    • Lustig M, Pauly JM. SPIRiT: iterative self-consistent parallel imaging reconstruction from arbitrary k-space. Magn Reson Med 2010;64:457-471.
    • (2010) Magn Reson Med , vol.64 , pp. 457-471
    • Lustig, M.1    Pauly, J.M.2
  • 10
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007;58:1182-1195.
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 11
    • 84902367741 scopus 로고    scopus 로고
    • Clinical performance of contrast enhanced abdominal pediatric MRI with fast combined parallel imaging compressed sensing reconstruction
    • [Epub ahead of print]
    • Zhang T, Chowdhury S, Lustig M, et al. Clinical performance of contrast enhanced abdominal pediatric MRI with fast combined parallel imaging compressed sensing reconstruction. J Magn Reson Imaging 2013 [Epub ahead of print].
    • (2013) J Magn Reson Imaging
    • Zhang, T.1    Chowdhury, S.2    Lustig, M.3
  • 12
    • 69449097366 scopus 로고    scopus 로고
    • k-t PCA: Temporally constrained k-t BLAST reconstruction using principal component analysis
    • Pedersen H, Kozerke S, Ringgaard S, Nehrke K, Kim WY. k-t PCA: temporally constrained k-t BLAST reconstruction using principal component analysis. Magn Reson Med 2009;62:706-716.
    • (2009) Magn Reson Med , vol.62 , pp. 706-716
    • Pedersen, H.1    Kozerke, S.2    Ringgaard, S.3    Nehrke, K.4    Kim, W.Y.5
  • 14
    • 79955624809 scopus 로고    scopus 로고
    • Accelerated dynamic MRI exploiting sparsity and low-rank structure: k-t SLR
    • Lingala S, Hu Y, DiBella E, Jacob M. Accelerated dynamic MRI exploiting sparsity and low-rank structure: k-t SLR. IEEE Trans Med Imaging 2011;30:1042-1054.
    • (2011) IEEE Trans Med Imaging , vol.30 , pp. 1042-1054
    • Lingala, S.1    Hu, Y.2    DiBella, E.3    Jacob, M.4
  • 18
    • 84921834859 scopus 로고    scopus 로고
    • Accelerating parameter mapping with a locally low rank constraint
    • Zhang T, Pauly JM, Levesque IR. Accelerating parameter mapping with a locally low rank constraint. Magn Reson Med 2013. doi:10.1002/mrm.25105.
    • (2013) Magn Reson Med
    • Zhang, T.1    Pauly, J.M.2    Levesque, I.R.3
  • 20
    • 0031848028 scopus 로고    scopus 로고
    • Hybrid ordered phase encoding (HOPE): An improved approach for respiratory artifact reduction
    • Jhooti P, Wiesmann F, Taylor AM, et al. Hybrid ordered phase encoding (HOPE): an improved approach for respiratory artifact reduction. J Magn Reson Imaging 1998;8:968-980.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 968-980
    • Jhooti, P.1    Wiesmann, F.2    Taylor, A.M.3
  • 22
    • 84921858363 scopus 로고    scopus 로고
    • Improving scan efficiency of respiratory gated imaging using compressed sensing with 3D Cartesian golden angle sampling
    • Doneva M, Stehning C, Nehrke K, Börnert P. Improving scan efficiency of respiratory gated imaging using compressed sensing with 3D Cartesian golden angle sampling. In: Proc 19th Annual Meeting ISMRM, Montréal; 2011. p 3057.
    • Proc 19th Annual Meeting ISMRM, Montréal; 2011 , pp. 3057
    • Doneva, M.1    Stehning, C.2    Nehrke, K.3    Börnert, P.4
  • 23
    • 84921870202 scopus 로고    scopus 로고
    • Nonrigid retrospective respiratory motion correction in whole-heart coronary MRA
    • Schmidt JFM, Buehrer M, Boesiger P, Kozerke S. Nonrigid retrospective respiratory motion correction in whole-heart coronary MRA. Magn Reson Med 2011;15:551-564.
    • (2011) Magn Reson Med , vol.15 , pp. 551-564
    • Schmidt, J.F.M.1    Buehrer, M.2    Boesiger, P.3    Kozerke, S.4
  • 26
    • 46849091615 scopus 로고    scopus 로고
    • Generalized reconstruction by inversion of coupled systems (GRICS) applied to free-breathing MRI
    • Odille F, Vuissoz PA, Marie PY, Felblinger J. Generalized reconstruction by inversion of coupled systems (GRICS) applied to free-breathing MRI. Magn Reson Med 2008;60:146-157.
    • (2008) Magn Reson Med , vol.60 , pp. 146-157
    • Odille, F.1    Vuissoz, P.A.2    Marie, P.Y.3    Felblinger, J.4
  • 27
    • 79958770897 scopus 로고    scopus 로고
    • Hierarchical adaptive local affine registration for fast and robust respiratory motion estimation
    • Buerger C, Schaeffter T, King AP. Hierarchical adaptive local affine registration for fast and robust respiratory motion estimation. Med Image Analysis 2011;15:551-564.
    • (2011) Med Image Analysis , vol.15 , pp. 551-564
    • Buerger, C.1    Schaeffter, T.2    King, A.P.3
  • 28
    • 81355161604 scopus 로고    scopus 로고
    • Nonrigid retrospective respiratory motion correction in whole-heart coronary MRA
    • Schmidt JFM, Buehrer M, Boesiger P, Kozerke S. Nonrigid retrospective respiratory motion correction in whole-heart coronary MRA. Magn Reson Med 2011;66:1541-1549.
    • (2011) Magn Reson Med , vol.66 , pp. 1541-1549
    • Schmidt, J.F.M.1    Buehrer, M.2    Boesiger, P.3    Kozerke, S.4
  • 31
    • 84861227005 scopus 로고    scopus 로고
    • Improved least squares MR image reconstruction using estimates of k-space data consistency
    • Johnson KM, Block WF, Reeder SB, Samsonov A. Improved least squares MR image reconstruction using estimates of k-space data consistency. Magn Reson Med 2012;67:1600-1608.
    • (2012) Magn Reson Med , vol.67 , pp. 1600-1608
    • Johnson, K.M.1    Block, W.F.2    Reeder, S.B.3    Samsonov, A.4
  • 32
    • 84902582014 scopus 로고    scopus 로고
    • ESPIRiT - An Eigenvalue Approach to Autocalibrating Parallel MRI: Where SENSE Meets GRAPPA
    • Epub ahead of print
    • Uecker M, Lai P, Murphy MJ, et al. ESPIRiT - an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA. Magn Reson Med 2013 [Epub ahead of print].
    • (2013) Magn Reson Med
    • Uecker, M.1    Lai, P.2    Murphy, M.J.3
  • 34
    • 71049116435 scopus 로고    scopus 로고
    • Exact matrix completion via convex optimization
    • Candès E, Recht B. Exact matrix completion via convex optimization. Found Comput Math 2009;9:717-772.
    • (2009) Found Comput Math , vol.9 , pp. 717-772
    • Candès, E.1    Recht, B.2
  • 35
    • 77951291046 scopus 로고    scopus 로고
    • A singular value thresholding algorithm for matrix completion
    • Cai J, Candès E, Shen Z. A singular value thresholding algorithm for matrix completion. Siam J Optim 2010;20:1956-1982.
    • (2010) Siam J Optim , vol.20 , pp. 1956-1982
    • Cai, J.1    Candès, E.2    Shen, Z.3
  • 36
    • 84921863495 scopus 로고    scopus 로고
    • Improved time-resolved, 3D phase contrast imaging through variable Poisson sampling and partial respiratory triggering
    • Alley MT, Murphy MJ, Keutzer K, et al.Improved time-resolved, 3D phase contrast imaging through variable Poisson sampling and partial respiratory triggering. In: Proc 19th Annual Meeting ISMRM, Montreal; 2011. p 1218.
    • Proc 19th Annual Meeting ISMRM, Montreal; 2011 , pp. 1218
    • Alley, M.T.1    Murphy, M.J.2    Keutzer, K.3
  • 42
    • 84872910908 scopus 로고    scopus 로고
    • Coil compression for accelerated imaging with Cartesian sampling
    • Zhang T, Pauly JM, Vasanawala SS, Lustig M. Coil compression for accelerated imaging with Cartesian sampling. Magn Reson Med 2013;69:571-582.
    • (2013) Magn Reson Med , vol.69 , pp. 571-582
    • Zhang, T.1    Pauly, J.M.2    Vasanawala, S.S.3    Lustig, M.4
  • 43
    • 0031404162 scopus 로고    scopus 로고
    • Modeling tracer kinetics in dynamics Gd-DTPA MR imaging
    • Tofts PS. Modeling tracer kinetics in dynamics Gd-DTPA MR imaging. J Magn Reson Imaging 1997;7:91-101.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 91-101
    • Tofts, P.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.