메뉴 건너뛰기




Volumn 90, Issue , 2015, Pages 97-103

Ultrasonography for confirmation of endotracheal tube placement: A systematic review and meta-analysis

Author keywords

Airway management; Critical care; Intubation; Meta analysis; Resuscitation; Ultrasonography

Indexed keywords

DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DIAGNOSTIC VALUE; ECHOGRAPHY; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; ESOPHAGUS INTUBATION; HUMAN; META ANALYSIS; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC; REVIEW; SENSITIVITY AND SPECIFICITY; SYSTEMATIC REVIEW; ADULT; ENDOSCOPIC ECHOGRAPHY; LUNG; PROCEDURES; STATISTICAL MODEL; TRACHEA;

EID: 84927713726     PISSN: 03009572     EISSN: 18731570     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2015.02.013     Document Type: Review
Times cited : (102)

References (37)
  • 1
    • 0028868095 scopus 로고
    • Death and other complications of emergency airway management in critically ill adults. A prospective investigation of 297 tracheal intubations
    • Schwartz D.E., Matthay M.A., Cohen N.H. Death and other complications of emergency airway management in critically ill adults. A prospective investigation of 297 tracheal intubations. Anesthesiology 1995, 82:367-376.
    • (1995) Anesthesiology , vol.82 , pp. 367-376
    • Schwartz, D.E.1    Matthay, M.A.2    Cohen, N.H.3
  • 2
    • 0031810482 scopus 로고    scopus 로고
    • Unplanned tracheal extubation outside the operating room: a quality improvement audit of hemodynamic and tracheal airway complications associated with emergency tracheal reintubation
    • Mort T.C. Unplanned tracheal extubation outside the operating room: a quality improvement audit of hemodynamic and tracheal airway complications associated with emergency tracheal reintubation. Anesth Analg 1998, 86:1171-1176.
    • (1998) Anesth Analg , vol.86 , pp. 1171-1176
    • Mort, T.C.1
  • 3
    • 12244311198 scopus 로고    scopus 로고
    • The assessment of three methods to verify tracheal tube placement in the emergency setting
    • Takeda T., Tanigawa K., Tanaka H., Hayashi Y., Goto E., Tanaka K. The assessment of three methods to verify tracheal tube placement in the emergency setting. Resuscitation 2003, 56:153-157.
    • (2003) Resuscitation , vol.56 , pp. 153-157
    • Takeda, T.1    Tanigawa, K.2    Tanaka, H.3    Hayashi, Y.4    Goto, E.5    Tanaka, K.6
  • 4
    • 0036284052 scopus 로고    scopus 로고
    • Comparison of three different methods to confirm tracheal tube placement in emergency intubation
    • Grmec S. Comparison of three different methods to confirm tracheal tube placement in emergency intubation. Intensive Care Med 2002, 28:701-704.
    • (2002) Intensive Care Med , vol.28 , pp. 701-704
    • Grmec, S.1
  • 5
    • 0032946318 scopus 로고    scopus 로고
    • The assessment of four different methods to verify tracheal tube placement in the critical care setting
    • Knapp S., Kofler J., Stoiser B., et al. The assessment of four different methods to verify tracheal tube placement in the critical care setting. Anesth Analg 1999, 88:766-770.
    • (1999) Anesth Analg , vol.88 , pp. 766-770
    • Knapp, S.1    Kofler, J.2    Stoiser, B.3
  • 6
    • 78349258536 scopus 로고    scopus 로고
    • Part 8: adult advanced cardiovascular life support: 2010 American Heart Association Guidelines for cardiopulmonary resuscitation and emergency cardiovascular care
    • Neumar R.W., Otto C.W., Link M.S., et al. Part 8: adult advanced cardiovascular life support: 2010 American Heart Association Guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation 2010, 122:S729-S767.
    • (2010) Circulation , vol.122 , pp. S729-S767
    • Neumar, R.W.1    Otto, C.W.2    Link, M.S.3
  • 7
    • 67149115130 scopus 로고    scopus 로고
    • Verification of endotracheal tube placement
    • ACEP Board of Directors Verification of endotracheal tube placement. Ann Emerg Med 2009, 54:141-142.
    • (2009) Ann Emerg Med , vol.54 , pp. 141-142
  • 8
    • 80052962116 scopus 로고    scopus 로고
    • Ultrasound instead of capnometry for confirming tracheal tube placement in an emergency?
    • Zechner P.M., Breitkreutz R. Ultrasound instead of capnometry for confirming tracheal tube placement in an emergency?. Resuscitation 2011, 82:1259-1261.
    • (2011) Resuscitation , vol.82 , pp. 1259-1261
    • Zechner, P.M.1    Breitkreutz, R.2
  • 9
    • 84920264826 scopus 로고    scopus 로고
    • Direct ultrasound methods: a confirmatory technique for proper endotracheal intubation in the emergency department
    • Abbasi S., Farsi D., Zare M.A., Hajimohammadi M., Rezai M., Hafezimoghadam P. Direct ultrasound methods: a confirmatory technique for proper endotracheal intubation in the emergency department. Eur J Emerg Med 2015, 22(1):10-16.
    • (2015) Eur J Emerg Med , vol.22 , Issue.1 , pp. 10-16
    • Abbasi, S.1    Farsi, D.2    Zare, M.A.3    Hajimohammadi, M.4    Rezai, M.5    Hafezimoghadam, P.6
  • 10
    • 84888258115 scopus 로고    scopus 로고
    • Secondary confirmation of endotracheal tube position by diaphragm motion in right subcostal ultrasound view
    • Hosseini J.S., Talebian M.T., Ghafari M.H., Eslami V. Secondary confirmation of endotracheal tube position by diaphragm motion in right subcostal ultrasound view. Int J Crit Illn Inj Sci 2013, 3:113-117.
    • (2013) Int J Crit Illn Inj Sci , vol.3 , pp. 113-117
    • Hosseini, J.S.1    Talebian, M.T.2    Ghafari, M.H.3    Eslami, V.4
  • 11
    • 84887223787 scopus 로고    scopus 로고
    • Real-time tracheal ultrasonography for confirmation of endotracheal tube placement during cardiopulmonary resuscitation
    • Chou H.C., Chong K.M., Sim S.S., et al. Real-time tracheal ultrasonography for confirmation of endotracheal tube placement during cardiopulmonary resuscitation. Resuscitation 2013, 84:1708-1712.
    • (2013) Resuscitation , vol.84 , pp. 1708-1712
    • Chou, H.C.1    Chong, K.M.2    Sim, S.S.3
  • 12
    • 84881225969 scopus 로고    scopus 로고
    • A feasibility study on bedside upper airway ultrasonography compared to waveform capnography for verifying endotracheal tube location after intubation
    • Adi O., Chuan T.W., Rishya M. A feasibility study on bedside upper airway ultrasonography compared to waveform capnography for verifying endotracheal tube location after intubation. Crit Ultrasound J 2013, 5:7.
    • (2013) Crit Ultrasound J , vol.5 , pp. 7
    • Adi, O.1    Chuan, T.W.2    Rishya, M.3
  • 13
    • 84857047395 scopus 로고    scopus 로고
    • Ultrasonographic lung sliding sign in confirming proper endotracheal intubation during emergency intubation
    • Sim S.S., Lien W.C., Chou H.C., et al. Ultrasonographic lung sliding sign in confirming proper endotracheal intubation during emergency intubation. Resuscitation 2012, 83:307-312.
    • (2012) Resuscitation , vol.83 , pp. 307-312
    • Sim, S.S.1    Lien, W.C.2    Chou, H.C.3
  • 14
    • 79955546445 scopus 로고    scopus 로고
    • Use of sonography for rapid identification of esophageal and tracheal intubations in adult patients
    • Muslu B., Sert H., Kaya A., et al. Use of sonography for rapid identification of esophageal and tracheal intubations in adult patients. J Ultrasound Med 2011, 30:671-676.
    • (2011) J Ultrasound Med , vol.30 , pp. 671-676
    • Muslu, B.1    Sert, H.2    Kaya, A.3
  • 15
    • 80052970431 scopus 로고    scopus 로고
    • Tracheal rapid ultrasound exam (T.R.U.E.) for confirming endotracheal tube placement during emergency intubation
    • Chou H.C., Tseng W.P., Wang C.H., et al. Tracheal rapid ultrasound exam (T.R.U.E.) for confirming endotracheal tube placement during emergency intubation. Resuscitation 2011, 82:1279-1284.
    • (2011) Resuscitation , vol.82 , pp. 1279-1284
    • Chou, H.C.1    Tseng, W.P.2    Wang, C.H.3
  • 16
    • 71649088121 scopus 로고    scopus 로고
    • How stylet use can effect confirmation of endotracheal tube position using ultrasound
    • Goksu E., Sayrac V., Oktay C., Kartal M., Akcimen M. How stylet use can effect confirmation of endotracheal tube position using ultrasound. Am J Emerg Med 2010, 28:32-36.
    • (2010) Am J Emerg Med , vol.28 , pp. 32-36
    • Goksu, E.1    Sayrac, V.2    Oktay, C.3    Kartal, M.4    Akcimen, M.5
  • 17
    • 68749109763 scopus 로고    scopus 로고
    • Confirmation of endotracheal intubation by combined ultrasonographic methods in the Emergency Department
    • Park S.C., Ryu J.H., Yeom S.R., Jeong J.W., Cho S.J. Confirmation of endotracheal intubation by combined ultrasonographic methods in the Emergency Department. Emerg Med Australas 2009, 21:293-297.
    • (2009) Emerg Med Australas , vol.21 , pp. 293-297
    • Park, S.C.1    Ryu, J.H.2    Yeom, S.R.3    Jeong, J.W.4    Cho, S.J.5
  • 18
    • 33845795275 scopus 로고    scopus 로고
    • Pilot study to evaluate the accuracy of ultrasonography in confirming endotracheal tube placement
    • Werner S.L., Smith C.E., Goldstein J.R., Jones R.A., Cydulka R.K. Pilot study to evaluate the accuracy of ultrasonography in confirming endotracheal tube placement. Ann Emerg Med 2007, 49:75-80.
    • (2007) Ann Emerg Med , vol.49 , pp. 75-80
    • Werner, S.L.1    Smith, C.E.2    Goldstein, J.R.3    Jones, R.A.4    Cydulka, R.K.5
  • 19
    • 34248149439 scopus 로고    scopus 로고
    • Transtracheal 2-D ultrasound for identification of esophageal intubation
    • Milling T.J., Jones M., Khan T., et al. Transtracheal 2-D ultrasound for identification of esophageal intubation. J Emerg Med 2007, 32:409-414.
    • (2007) J Emerg Med , vol.32 , pp. 409-414
    • Milling, T.J.1    Jones, M.2    Khan, T.3
  • 20
    • 34248175803 scopus 로고    scopus 로고
    • The sensitivity and specificity of transcricothyroid ultrasonography to confirm endotracheal tube placement in a cadaver model
    • Ma G., Davis D.P., Schmitt J., Vilke G.M., Chan T.C., Hayden S.R. The sensitivity and specificity of transcricothyroid ultrasonography to confirm endotracheal tube placement in a cadaver model. J Emerg Med 2007, 32:405-407.
    • (2007) J Emerg Med , vol.32 , pp. 405-407
    • Ma, G.1    Davis, D.P.2    Schmitt, J.3    Vilke, G.M.4    Chan, T.C.5    Hayden, S.R.6
  • 21
    • 33644511139 scopus 로고    scopus 로고
    • Confirmation of endotracheal tube placement after intubation using the ultrasound sliding lung sign
    • Weaver B., Lyon M., Blaivas M. Confirmation of endotracheal tube placement after intubation using the ultrasound sliding lung sign. Acad Emerg Med 2006, 13:239-244.
    • (2006) Acad Emerg Med , vol.13 , pp. 239-244
    • Weaver, B.1    Lyon, M.2    Blaivas, M.3
  • 22
    • 69149107165 scopus 로고    scopus 로고
    • Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement
    • [w64]
    • Moher D., Liberati A., Tetzlaff J., Altman D.G. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Ann Intern Med 2009, 151:264-269. [w64].
    • (2009) Ann Intern Med , vol.151 , pp. 264-269
    • Moher, D.1    Liberati, A.2    Tetzlaff, J.3    Altman, D.G.4
  • 23
    • 33847606952 scopus 로고    scopus 로고
    • Development of AMSTAR: a measurement tool to assess the methodological quality of systematic reviews
    • Shea B.J., Grimshaw J.M., Wells G.A., et al. Development of AMSTAR: a measurement tool to assess the methodological quality of systematic reviews. BMC Med Res Methodol 2007, 7:10.
    • (2007) BMC Med Res Methodol , vol.7 , pp. 10
    • Shea, B.J.1    Grimshaw, J.M.2    Wells, G.A.3
  • 26
    • 52949141475 scopus 로고    scopus 로고
    • An empirical comparison of methods for meta-analysis of diagnostic accuracy showed hierarchical models are necessary
    • Harbord R.M., Whiting P., Sterne J.A., et al. An empirical comparison of methods for meta-analysis of diagnostic accuracy showed hierarchical models are necessary. J Clin Epidemiol 2008, 61:1095-1103.
    • (2008) J Clin Epidemiol , vol.61 , pp. 1095-1103
    • Harbord, R.M.1    Whiting, P.2    Sterne, J.A.3
  • 28
    • 0030922816 scopus 로고    scopus 로고
    • Bias in meta-analysis detected by a simple, graphical test
    • Egger M., Davey Smith G., Schneider M., Minder C. Bias in meta-analysis detected by a simple, graphical test. BMJ 1997, 315:629-634.
    • (1997) BMJ , vol.315 , pp. 629-634
    • Egger, M.1    Davey Smith, G.2    Schneider, M.3    Minder, C.4
  • 30
    • 80054036720 scopus 로고    scopus 로고
    • Ultrasonography in the management of the airway
    • Kristensen M.S. Ultrasonography in the management of the airway. Acta Anaesthesiol Scand 2011, 55:1155-1173.
    • (2011) Acta Anaesthesiol Scand , vol.55 , pp. 1155-1173
    • Kristensen, M.S.1
  • 31
    • 70349303769 scopus 로고    scopus 로고
    • Confirmation of endotracheal tube position: a narrative review
    • Rudraraju P., Eisen L.A. Confirmation of endotracheal tube position: a narrative review. J Intensive Care Med 2009, 24:283-292.
    • (2009) J Intensive Care Med , vol.24 , pp. 283-292
    • Rudraraju, P.1    Eisen, L.A.2
  • 32
    • 0035099882 scopus 로고    scopus 로고
    • Capnography alone is imperfect for endotracheal tube placement confirmation during emergency intubation
    • Li J. Capnography alone is imperfect for endotracheal tube placement confirmation during emergency intubation. J Emerg Med 2001, 20:223-229.
    • (2001) J Emerg Med , vol.20 , pp. 223-229
    • Li, J.1
  • 33
    • 77952869179 scopus 로고    scopus 로고
    • The addition of a brief ultrasound examination to clinical assessment increases the ability to confirm placement of double-lumen endotracheal tubes
    • Sustic A., Protic A., Cicvaric T., Zupan Z. The addition of a brief ultrasound examination to clinical assessment increases the ability to confirm placement of double-lumen endotracheal tubes. J Clin Anesth 2010, 22:246-249.
    • (2010) J Clin Anesth , vol.22 , pp. 246-249
    • Sustic, A.1    Protic, A.2    Cicvaric, T.3    Zupan, Z.4
  • 34
    • 66249096031 scopus 로고    scopus 로고
    • A prospective comparison of diaphragmatic ultrasound and chest radiography to determine endotracheal tube position in a pediatric emergency department
    • Kerrey B.T., Geis G.L., Quinn A.M., Hornung R.W., Ruddy R.M. A prospective comparison of diaphragmatic ultrasound and chest radiography to determine endotracheal tube position in a pediatric emergency department. Pediatrics 2009, 123:e1039-e1044.
    • (2009) Pediatrics , vol.123 , pp. e1039-e1044
    • Kerrey, B.T.1    Geis, G.L.2    Quinn, A.M.3    Hornung, R.W.4    Ruddy, R.M.5
  • 35
    • 7244255763 scopus 로고    scopus 로고
    • Secondary confirmation of endotracheal tube position by ultrasound image
    • Hsieh K.S., Lee C.L., Lin C.C., Huang T.C., Weng K.P., Lu W.H. Secondary confirmation of endotracheal tube position by ultrasound image. Crit Care Med 2004, 32:S374-S377.
    • (2004) Crit Care Med , vol.32 , pp. S374-S377
    • Hsieh, K.S.1    Lee, C.L.2    Lin, C.C.3    Huang, T.C.4    Weng, K.P.5    Lu, W.H.6
  • 37
    • 36849063117 scopus 로고    scopus 로고
    • Use of bedside ultrasonography for endotracheal tube placement in pediatric patients: a feasibility study
    • Galicinao J., Bush A.J., Godambe S.A. Use of bedside ultrasonography for endotracheal tube placement in pediatric patients: a feasibility study. Pediatrics 2007, 120:1297-1303.
    • (2007) Pediatrics , vol.120 , pp. 1297-1303
    • Galicinao, J.1    Bush, A.J.2    Godambe, S.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.