메뉴 건너뛰기




Volumn 120, Issue 6, 2007, Pages 1297-1303

Use of bedside ultrasonography for endotracheal tube placement in pediatric patients: A feasibility study

Author keywords

End tidal carbon dioxide detector; Endotracheal tube; Intubation; Ultrasonography

Indexed keywords

ADOLESCENT; ARTICLE; CHILD; COLORIMETRY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; ECHOGRAPHY; EMERGENCY WARD; END TIDAL CARBON DIOXIDE TENSION; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; EXTUBATION; FALSE NEGATIVE RESULT; FEMALE; HUMAN; IMAGE QUALITY; INFANT; MAJOR CLINICAL STUDY; MALE; NEWBORN; POINT OF CARE TESTING; PRIORITY JOURNAL; SAMPLE SIZE; THORAX RADIOGRAPHY; TRACHEA MUSCLE; ULTRASOUND TRANSDUCER;

EID: 36849063117     PISSN: 00314005     EISSN: 02105721     Source Type: Journal    
DOI: 10.1542/peds.2006-2959     Document Type: Article
Times cited : (91)

References (19)
  • 1
    • 0033853383 scopus 로고    scopus 로고
    • Carbon dioxide kinetics and capnography during critical care
    • Anderson CT, Breen PH. Carbon dioxide kinetics and capnography during critical care. Crit Care. 2000;4:207-215
    • (2000) Crit Care , vol.4 , pp. 207-215
    • Anderson, C.T.1    Breen, P.H.2
  • 2
    • 0031898108 scopus 로고    scopus 로고
    • Portable devices used to detect endotracheal intubation during emergency situations: A review
    • Cardoso MM, Banner MJ, Melker RJ, Bjoraker DG. Portable devices used to detect endotracheal intubation during emergency situations: a review. Crit Care Med. 1998;26:957-964
    • (1998) Crit Care Med , vol.26 , pp. 957-964
    • Cardoso, M.M.1    Banner, M.J.2    Melker, R.J.3    Bjoraker, D.G.4
  • 3
    • 0025300671 scopus 로고
    • End tidal carbon dioxide detector for monitoring cardiopulmonary resuscitation
    • Muir JD, Randalls PB, Smith GB. End tidal carbon dioxide detector for monitoring cardiopulmonary resuscitation. BMJ. 1990;301:41-42
    • (1990) BMJ , vol.301 , pp. 41-42
    • Muir, J.D.1    Randalls, P.B.2    Smith, G.B.3
  • 4
    • 0026538036 scopus 로고
    • Multicenter study of a portable, hand-size, colorimetric end-tidal carbon dioxide detection device
    • Ornato JP, Shipley JB, Racht EM, et al. Multicenter study of a portable, hand-size, colorimetric end-tidal carbon dioxide detection device. Ann Emerg Med. 1992;21:518-523
    • (1992) Ann Emerg Med , vol.21 , pp. 518-523
    • Ornato, J.P.1    Shipley, J.B.2    Racht, E.M.3
  • 5
    • 0031800984 scopus 로고    scopus 로고
    • End-tidal carbon dioxide monitoring in emergency medicine, part 1: Basic principles
    • Ward KR, Yealy DM. End-tidal carbon dioxide monitoring in emergency medicine, part 1: basic principles. Acad Emerg Med. 1998;5:628-636
    • (1998) Acad Emerg Med , vol.5 , pp. 628-636
    • Ward, K.R.1    Yealy, D.M.2
  • 6
    • 0028907202 scopus 로고
    • Colorimetric end-tidal carbon dioxide detector
    • Bhende MS. Colorimetric end-tidal carbon dioxide detector. Pediatr Emerg Care. 1995;11:58-61
    • (1995) Pediatr Emerg Care , vol.11 , pp. 58-61
    • Bhende, M.S.1
  • 7
    • 0031981865 scopus 로고    scopus 로고
    • Glottic positioning of the endotracheal tube tip: A diagnostic dilemma
    • Werman HA, Falcone RE. Glottic positioning of the endotracheal tube tip: a diagnostic dilemma. Ann Emerg Med. 1998;31:643-646
    • (1998) Ann Emerg Med , vol.31 , pp. 643-646
    • Werman, H.A.1    Falcone, R.E.2
  • 8
    • 0034084158 scopus 로고    scopus 로고
    • Identification and description of esophageal intubation using ultrasound
    • Drescher MJ, Conard FU, Schamban NE. Identification and description of esophageal intubation using ultrasound. Acad Emerg Med. 2000;7:722-725
    • (2000) Acad Emerg Med , vol.7 , pp. 722-725
    • Drescher, M.J.1    Conard, F.U.2    Schamban, N.E.3
  • 9
    • 0023628368 scopus 로고
    • Ultrasound confirmation of endotracheal tube placement
    • Raphael DT, Conard FU III. Ultrasound confirmation of endotracheal tube placement. J Clin Ultrasound. 1987;15:459-462
    • (1987) J Clin Ultrasound , vol.15 , pp. 459-462
    • Raphael, D.T.1    Conard III, F.U.2
  • 10
    • 0022588082 scopus 로고
    • Endotracheal tubes in neonates: Sonographic positioning
    • Slovis TL, Poland RL. Endotracheal tubes in neonates: sonographic positioning. Radiology. 1986;160:262-263
    • (1986) Radiology , vol.160 , pp. 262-263
    • Slovis, T.L.1    Poland, R.L.2
  • 11
    • 0023772962 scopus 로고
    • Sonographic verification of endotracheal tube position in neonates: A modified technique
    • Lingle PA. Sonographic verification of endotracheal tube position in neonates: a modified technique. J Clin Ultrasound. 1988;16:605-609
    • (1988) J Clin Ultrasound , vol.16 , pp. 605-609
    • Lingle, P.A.1
  • 12
    • 7244255763 scopus 로고    scopus 로고
    • Secondary confirmation of endotracheal tube position by ultrasound image
    • Hsieh KS, Lee CL, Lin CC, Huang TC, Weng KP, Lu WH. Secondary confirmation of endotracheal tube position by ultrasound image. Crit Care Med. 2004;32(suppl):S374-S377
    • (2004) Crit Care Med , vol.32 , Issue.SUPPL.
    • Hsieh, K.S.1    Lee, C.L.2    Lin, C.C.3    Huang, T.C.4    Weng, K.P.5    Lu, W.H.6
  • 13
    • 13744251530 scopus 로고    scopus 로고
    • Where's the tube? Evaluation of hand-held ultrasound in confirming endotracheal tube placement
    • Chun R, Kirkpatrick AW, Sirois M, et al. Where's the tube? Evaluation of hand-held ultrasound in confirming endotracheal tube placement. Prehosp Disaster Med. 2004;19:366-369
    • (2004) Prehosp Disaster Med , vol.19 , pp. 366-369
    • Chun, R.1    Kirkpatrick, A.W.2    Sirois, M.3
  • 14
    • 33644511139 scopus 로고    scopus 로고
    • Confirmation of endotracheal tube placement after intubation using the ultrasound sliding lung sign
    • Weaver B, Lyon M, Blaivas M. Confirmation of endotracheal tube placement after intubation using the ultrasound sliding lung sign. Acad Emerg Med. 2006;13:239-244
    • (2006) Acad Emerg Med , vol.13 , pp. 239-244
    • Weaver, B.1    Lyon, M.2    Blaivas, M.3
  • 15
    • 0002156078 scopus 로고    scopus 로고
    • The difficult and failed airway
    • Walls RM, Luten RC, Murphy MF, Schneider RE, eds, Philadelphia, PA: Lippincott Williams & Wilkins;
    • Murphy MF, Walls RM. The difficult and failed airway. In: Walls RM, Luten RC, Murphy MF, Schneider RE, eds. Manual of Emergency Airway Management. Philadelphia, PA: Lippincott Williams & Wilkins; 2000:31-43
    • (2000) Manual of Emergency Airway Management , pp. 31-43
    • Murphy, M.F.1    Walls, R.M.2
  • 16
    • 0001109910 scopus 로고
    • Grading of patients for surgical procedures
    • Saklad M. Grading of patients for surgical procedures. Anesthesiology. 1941;2:281-284
    • (1941) Anesthesiology , vol.2 , pp. 281-284
    • Saklad, M.1
  • 18
    • 0033950423 scopus 로고    scopus 로고
    • Effect of out-ofhospital pediatric endotracheal intubation on survival and neurological outcome: A controlled clinical trial
    • Gausche M, Lewis RJ, Stratton SJ, et al. Effect of out-ofhospital pediatric endotracheal intubation on survival and neurological outcome: a controlled clinical trial. JAMA. 2000;283:783-790
    • (2000) JAMA , vol.283 , pp. 783-790
    • Gausche, M.1    Lewis, R.J.2    Stratton, S.J.3
  • 19
    • 33845795275 scopus 로고    scopus 로고
    • Pilot study to evaluate the accuracy of ultrasonography in confirming endotracheal tube placement
    • Werner SL, Smith CE, Goldstein JR, Jones RA, Cydulka RK. Pilot study to evaluate the accuracy of ultrasonography in confirming endotracheal tube placement. Ann Emerg Med. 2007;49:75-80
    • (2007) Ann Emerg Med , vol.49 , pp. 75-80
    • Werner, S.L.1    Smith, C.E.2    Goldstein, J.R.3    Jones, R.A.4    Cydulka, R.K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.