메뉴 건너뛰기




Volumn 108, Issue 2, 2009, Pages 461-465

Airway management in children: Ultrasonography assessment of tracheal intubation in real time?

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; AUSCULTATION; CAPNOGRAPHY; CHILD; CLINICAL ARTICLE; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; FEMALE; GLOTTIS; HUMAN; IMAGE ANALYSIS; INHALATION ANESTHESIA; MALE; PRESCHOOL CHILD; PRIORITY JOURNAL; REAL TIME ECHOGRAPHY; THORAX WALL; TRACHEA; VOCAL CORD; COMPUTER SYSTEM; DIGESTIVE TRACT INTUBATION; ECHOGRAPHY; ESOPHAGUS; INFANT; LARYNGOSCOPY; LUNG;

EID: 59649095365     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/ane.0b013e31819240f5     Document Type: Article
Times cited : (75)

References (27)
  • 2
    • 0033032727 scopus 로고    scopus 로고
    • Does the murphy eye reduce the reliability of chest auscultation in detecting endobronchial intubation?
    • Sugiyama K, Yokoyama K, Satoh K, Nishihara M, Yoshitomi T. Does the murphy eye reduce the reliability of chest auscultation in detecting endobronchial intubation? Anesth Analg 1999; 88:1380-3
    • (1999) Anesth Analg , vol.88 , pp. 1380-1383
    • Sugiyama, K.1    Yokoyama, K.2    Satoh, K.3    Nishihara, M.4    Yoshitomi, T.5
  • 3
    • 0024449624 scopus 로고
    • Comparison of end-tidal carbon dioxide, oxygen saturation and clinical signs for the detection of oesophageal intubation
    • Vaghadia H, Jenkins LC, Ford RW. Comparison of end-tidal carbon dioxide, oxygen saturation and clinical signs for the detection of oesophageal intubation. Can J Anaesth 1989; 36:560-4
    • (1989) Can J Anaesth , vol.36 , pp. 560-564
    • Vaghadia, H.1    Jenkins, L.C.2    Ford, R.W.3
  • 6
    • 0023628368 scopus 로고
    • Ultrasound confirmation of endotracheal tube placement
    • Raphael D, Conard F. Ultrasound confirmation of endotracheal tube placement. J Clin Ultrasound 1987;15:459-62
    • (1987) J Clin Ultrasound , vol.15 , pp. 459-462
    • Raphael, D.1    Conard, F.2
  • 7
    • 0022588082 scopus 로고
    • Endotracheal tubes in neonates: Sonographic positioning
    • Slovis T, Poland R. Endotracheal tubes in neonates: sonographic positioning. Radiology 1986;160:262-3
    • (1986) Radiology , vol.160 , pp. 262-263
    • Slovis, T.1    Poland, R.2
  • 8
    • 0036284052 scopus 로고    scopus 로고
    • Comparison of three different methods to confirm tracheal tube placement in emergency intubation
    • Grmec S. Comparison of three different methods to confirm tracheal tube placement in emergency intubation. Intensive Care Med 2002;28:701-4
    • (2002) Intensive Care Med , vol.28 , pp. 701-704
    • Grmec, S.1
  • 9
    • 17144381219 scopus 로고    scopus 로고
    • Intubation confirmation techniques associated with unrecognized non-tracheal intubations by Prehospital providers
    • Bair AE, Smith D, Lichty L. Intubation confirmation techniques associated with unrecognized non-tracheal intubations by Prehospital providers. J Emerg Med 2005;28:403-7
    • (2005) J Emerg Med , vol.28 , pp. 403-407
    • Bair, A.E.1    Smith, D.2    Lichty, L.3
  • 10
    • 33646535907 scopus 로고    scopus 로고
    • Out-of-Hospital endotracheal intubation: Where are we?
    • Wang HE, Yealy DM. Out-of-Hospital endotracheal intubation: where are we? Ann Emerg Med 2006;47:532-41
    • (2006) Ann Emerg Med , vol.47 , pp. 532-541
    • Wang, H.E.1    Yealy, D.M.2
  • 11
    • 33644516631 scopus 로고    scopus 로고
    • Verification of endotracheal tube placement by prehospital providers: Is a portable fiberoptic bronchoscope of value?
    • Angelotti T, Weiss EL, Lemmens HJM, Brock-Utne J. Verification of endotracheal tube placement by prehospital providers: is a portable fiberoptic bronchoscope of value? Air Med J 2006;25:74-8
    • (2006) Air Med J , vol.25 , pp. 74-78
    • Angelotti, T.1    Weiss, E.L.2    Lemmens, H.J.M.3    Brock-Utne, J.4
  • 12
    • 0032943609 scopus 로고    scopus 로고
    • Evaluation of the SCOTI device for confirming blind nasal intubation
    • Trikha A, Singh C, Rewari V, Arora MK. Evaluation of the SCOTI device for confirming blind nasal intubation. Anaesthesia 1999;54:347-9
    • (1999) Anaesthesia , vol.54 , pp. 347-349
    • Trikha, A.1    Singh, C.2    Rewari, V.3    Arora, M.K.4
  • 13
    • 0036713717 scopus 로고    scopus 로고
    • Clinical Application of Acoustic Reflectometry in Predicting the Difficult Airway
    • Ochroch EA, Eckmann DM. Clinical Application of Acoustic Reflectometry in Predicting the Difficult Airway. Anesth Analg 2002;95:645-9
    • (2002) Anesth Analg , vol.95 , pp. 645-649
    • Ochroch, E.A.1    Eckmann, D.M.2
  • 14
    • 67649145746 scopus 로고    scopus 로고
    • Standards for basic anesthetic monitoring. Directory of Members. Park Ridge, IL: American Society of Anesthesiologists, 1996;394
    • Standards for basic anesthetic monitoring. Directory of Members. Park Ridge, IL: American Society of Anesthesiologists, 1996;394
  • 15
    • 0035099882 scopus 로고    scopus 로고
    • Capnography alone is imperfect for endotracheal tube placement confirmation during emergency intubation
    • Li J. Capnography alone is imperfect for endotracheal tube placement confirmation during emergency intubation. J Emerg Med 2001;20:223-9
    • (2001) J Emerg Med , vol.20 , pp. 223-229
    • Li, J.1
  • 16
    • 0029300520 scopus 로고
    • The use of capnography for recognition of esophageal intubation in the neonatal intensive care unit
    • Roberts WA, Maniscalco WM, Cohen AR, Litman RS, Chhibber A. The use of capnography for recognition of esophageal intubation in the neonatal intensive care unit. Pediatr Pulmonol 1995;19:262-8
    • (1995) Pediatr Pulmonol , vol.19 , pp. 262-268
    • Roberts, W.A.1    Maniscalco, W.M.2    Cohen, A.R.3    Litman, R.S.4    Chhibber, A.5
  • 17
    • 0034097390 scopus 로고    scopus 로고
    • Acoustic reflectometry profiles of endotracheal and esophageal intubation
    • Raphael DT. Acoustic reflectometry profiles of endotracheal and esophageal intubation. Anesthesiology 2000;92:1293-9
    • (2000) Anesthesiology , vol.92 , pp. 1293-1299
    • Raphael, D.T.1
  • 18
    • 0025690459 scopus 로고
    • Use of the oesophageal detector device in children under one year of age
    • Haynes SR, Morton NS. Use of the oesophageal detector device in children under one year of age. Anaesthesia 1990;45:1067-9
    • (1990) Anaesthesia , vol.45 , pp. 1067-1069
    • Haynes, S.R.1    Morton, N.S.2
  • 19
    • 0036891187 scopus 로고    scopus 로고
    • Detection and correction of endotracheal-tube position in premature neonates
    • Lange M, Jonat S, Nikischin W. Detection and correction of endotracheal-tube position in premature neonates. Pediatr Pulmonol 2002;34:455-61
    • (2002) Pediatr Pulmonol , vol.34 , pp. 455-461
    • Lange, M.1    Jonat, S.2    Nikischin, W.3
  • 21
    • 0242659189 scopus 로고    scopus 로고
    • Ultrasound imaging in the preoperative estimation of the size of tracheostomy tube required in specialised operations in children
    • Hardee PS, Ng SY, Cashman M. Ultrasound imaging in the preoperative estimation of the size of tracheostomy tube required in specialised operations in children. Br J Oral Maxillofac Surg 2003;41:312-6
    • (2003) Br J Oral Maxillofac Surg , vol.41 , pp. 312-316
    • Hardee, P.S.1    Ng, S.Y.2    Cashman, M.3
  • 22
    • 0023772962 scopus 로고
    • Sonographic verification of endotracheal tube position in neonates: A modified technique
    • Lingle PA. Sonographic verification of endotracheal tube position in neonates: a modified technique. J Clin Ultrasound 1988;16:605-9
    • (1988) J Clin Ultrasound , vol.16 , pp. 605-609
    • Lingle, P.A.1
  • 23
    • 7244255763 scopus 로고    scopus 로고
    • Secondary confirmation of endotracheal tube position by ultrasound image
    • Hsieh KS, Lee CL, Lin CC, Huang TC, Weng KP, Lu WH. Secondary confirmation of endotracheal tube position by ultrasound image. Crit Care Med 2004;32(9 Suppl): S374-S377
    • (2004) Crit Care Med , vol.32 , Issue.9 SUPPL.
    • Hsieh, K.S.1    Lee, C.L.2    Lin, C.C.3    Huang, T.C.4    Weng, K.P.5    Lu, W.H.6
  • 25
    • 33644511139 scopus 로고    scopus 로고
    • Confirmation of endotracheal tube placement after intubation using the ultrasound sliding lung sign
    • Weaver B, Lyon M, Blaivas M. Confirmation of endotracheal tube placement after intubation using the ultrasound sliding lung sign. Acad Emerg Med 2006;13:239-44
    • (2006) Acad Emerg Med , vol.13 , pp. 239-244
    • Weaver, B.1    Lyon, M.2    Blaivas, M.3
  • 27
    • 33845795275 scopus 로고    scopus 로고
    • Pilot study to evaluate the accuracy of ultrasonography in confirming endotracheal tube placement
    • Werner SL, Smith CE, Goldstein JR, Jones RA, Cydulka RK. Pilot study to evaluate the accuracy of ultrasonography in confirming endotracheal tube placement. Ann Emerg Med 2007;49:75-80
    • (2007) Ann Emerg Med , vol.49 , pp. 75-80
    • Werner, S.L.1    Smith, C.E.2    Goldstein, J.R.3    Jones, R.A.4    Cydulka, R.K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.