1
-
-
70349354109
-
Advanced cardiovascular life support: Section 3. Adjuncts for oxygenation, ventilation and airway control. the American Heart Association in collaboration with the International Liaison Committee on Resuscitation
-
Guidelines 2000 for Cardiopulmonary Resuscitation Emergency Cardiovascular Care: Part 6
-
Guidelines 2000 for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care: Part 6. Advanced cardiovascular life support: Section 3. Adjuncts for oxygenation, ventilation and airway control. The American Heart Association in collaboration with the International Liaison Committee on Resuscitation. Circulation. 2000 ; 102 (S8). 195-1104.
-
(2000)
Circulation
, vol.102
, Issue.S8
, pp. 195-1104
-
-
-
2
-
-
0027672059
-
Oesophageal intubation: An analysis of 2000 incident reports
-
Holland R., Webb RK, Runciman WB Oesophageal intubation: an analysis of 2000 incident reports. Anaesth Intensive Care. 1993 ; 21 (5). 608-610. (Pubitemid 23311291)
-
(1993)
Anaesthesia and Intensive Care
, vol.21
, Issue.5
, pp. 608-610
-
-
Holland, R.1
Webb, R.K.2
Runciman, W.B.3
-
3
-
-
2942564583
-
Emergency physician-verified out-of-hospital intubation: Miss rates by paramedics
-
Jones JH, Murphy MP, Dickson RL, Somerville GG, Brizendine EJ Emergency physician-verified out-of-hospital intubation: miss rates by paramedics. Acad Emerg Med. 2004 ; 11 (6). 707-709.
-
(2004)
Acad Emerg Med
, vol.11
, Issue.6
, pp. 707-709
-
-
Jones, J.H.1
Murphy, M.P.2
Dickson, R.L.3
Somerville, G.G.4
Brizendine, E.J.5
-
4
-
-
0035148486
-
Misplaced endotracheal tubes by paramedics in an urban emergency medical services system
-
Katz SH, Falk JL Misplaced endotracheal tubes by paramedics in an urban emergency medical services system. Ann Emerg Med. 2001 ; 37 (1). 32-37.
-
(2001)
Ann Emerg Med
, vol.37
, Issue.1
, pp. 32-37
-
-
Katz, S.H.1
Falk, J.L.2
-
5
-
-
20444414506
-
Esophageal intubation with indirect clinical tests during emergency tracheal intubation: A report on patient morbidity
-
Mort TC Esophageal intubation with indirect clinical tests during emergency tracheal intubation: a report on patient morbidity. J Clin Anesth. 2005 ; 17 (4). 255-262.
-
(2005)
J Clin Anesth
, vol.17
, Issue.4
, pp. 255-262
-
-
Mort, T.C.1
-
6
-
-
0031007604
-
Out-of-hospital experience with the syringe esophageal detector device
-
Pelucio M., Halligan L., Dhindsa H. Out-of-hospital experience with the syringe esophageal detector device. Acad Emerg Med. 1997 ; 4 (6). 563-568.
-
(1997)
Acad Emerg Med
, vol.4
, Issue.6
, pp. 563-568
-
-
Pelucio, M.1
Halligan, L.2
Dhindsa, H.3
-
7
-
-
0347359223
-
Endotracheal intubation and esophageal tracheal Combitube insertion by regular ambulance attendants: A comparative trial
-
Rumball C., Macdonald D., Barber P., Wong H., Smecher C. Endotracheal intubation and esophageal tracheal Combitube insertion by regular ambulance attendants: a comparative trial. Prehosp Emerg Care. 2004 ; 8 (1). 15-22.
-
(2004)
Prehosp Emerg Care
, vol.8
, Issue.1
, pp. 15-22
-
-
Rumball, C.1
MacDonald, D.2
Barber, P.3
Wong, H.4
Smecher, C.5
-
8
-
-
0043151094
-
Field trial of endotracheal intubation by basic EMTs
-
Sayre MR, Sakles JC, Mistler AF, Evans JL, Kramer AT, Pancioli AM Field trial of endotracheal intubation by basic EMTs. Ann Emerg Med. 1998 ; 31 (2). 228-233.
-
(1998)
Ann Emerg Med
, vol.31
, Issue.2
, pp. 228-233
-
-
Sayre, M.R.1
Sakles, J.C.2
Mistler, A.F.3
Evans, J.L.4
Kramer, A.T.5
Pancioli, A.M.6
-
9
-
-
0019954801
-
Endotracheal tube misplacement
-
Stirt JA Endotracheal tube misplacement. Anaesth Intensive Care. 1982 ; 10 (3). 274-276.
-
(1982)
Anaesth Intensive Care
, vol.10
, Issue.3
, pp. 274-276
-
-
Stirt, J.A.1
-
10
-
-
33847212454
-
The out-of-hospital esophageal and endobronchial intubations performed by emergency physicians
-
Timmermann A., Russo SG, Eich C., et al. The out-of-hospital esophageal and endobronchial intubations performed by emergency physicians. Anesth Analg. 2007 ; 104 (3). 619-623.
-
(2007)
Anesth Analg
, vol.104
, Issue.3
, pp. 619-623
-
-
Timmermann, A.1
Russo, S.G.2
Eich, C.3
-
11
-
-
0027452158
-
The Australian incident monitoring study: An analysis of 2000 incident reports
-
Webb RK, Currie M., Morgan C., et al. The Australian incident monitoring study - An analysis of 2000 incident reports. Anaesth Intensive Care. 1993 ; 21 (5). 520-528. (Pubitemid 23311279)
-
(1993)
Anaesthesia and Intensive Care
, vol.21
, Issue.5
, pp. 520-528
-
-
Webb, R.K.1
Currie, M.2
Morgan, C.A.3
Williamson, J.A.4
Mackay, P.5
Russell, W.J.6
Runciman, W.B.7
-
12
-
-
34047155109
-
Unrecognized misplacement of endotracheal tubes by ground prehospital providers
-
Wirtz DD, Ortiz C., Newman DH, Zhitomirsky I. Unrecognized misplacement of endotracheal tubes by ground prehospital providers. Prehosp Emerg Care. 2007 ; 11 (2). 213-218.
-
(2007)
Prehosp Emerg Care
, vol.11
, Issue.2
, pp. 213-218
-
-
Wirtz, D.D.1
Ortiz, C.2
Newman, D.H.3
Zhitomirsky, I.4
-
13
-
-
0018948468
-
Signs of endotracheal intubation
-
Howells TH, Riethmuller RJ Signs of endotracheal intubation. Anaesthesia. 1980 ; 35 (10). 984-986.
-
(1980)
Anaesthesia
, vol.35
, Issue.10
, pp. 984-986
-
-
Howells, T.H.1
Riethmuller, R.J.2
-
14
-
-
0024461731
-
Assessment of routine chest roetgenograms and the physical examination to confirm endotracheal tube position
-
Brunel W., Coleman DL, Schwartz DE, Peper E., Cohen NH Assessment of routine chest roetgenograms and the physical examination to confirm endotracheal tube position. Chest. 1989 ; 96 (5). 1043-1045.
-
(1989)
Chest
, vol.96
, Issue.5
, pp. 1043-1045
-
-
Brunel, W.1
Coleman, D.L.2
Schwartz, D.E.3
Peper, E.4
Cohen, N.H.5
-
15
-
-
17144381219
-
Intubation confirmation techniques associated with unrecognized non-tracheal intubations by pre-hospital providers
-
Bair AE, Smith D., Lichty L. Intubation confirmation techniques associated with unrecognized non-tracheal intubations by pre-hospital providers. J Emerg Med. 2005 ; 28 (4). 403-407.
-
(2005)
J Emerg Med
, vol.28
, Issue.4
, pp. 403-407
-
-
Bair, A.E.1
Smith, D.2
Lichty, L.3
-
16
-
-
0022512624
-
Esophageal intubation: A review of detection techniques
-
Birmingham PL, Cheney FW, Ward RJ Esophageal intubation: a review of detection techniques. Anesth Analg. 1986 ; 65 (8). 886-891.
-
(1986)
Anesth Analg
, vol.65
, Issue.8
, pp. 886-891
-
-
Birmingham, P.L.1
Cheney, F.W.2
Ward, R.J.3
-
17
-
-
0035215821
-
Verification of endotracheal tube position
-
Salem MR Verification of endotracheal tube position. Anesth Clin North Am. 2001 ; 19 (4). 813-839.
-
(2001)
Anesth Clin North Am
, vol.19
, Issue.4
, pp. 813-839
-
-
Salem, M.R.1
-
18
-
-
0018849860
-
Accidental intubation of the oesophagus
-
Pollard BJ, Junius F. Accidental intubation of the oesophagus. Anaesth Intensive Care. 1980 ; 8 (2). 183-186.
-
(1980)
Anaesth Intensive Care
, vol.8
, Issue.2
, pp. 183-186
-
-
Pollard, B.J.1
Junius, F.2
-
19
-
-
0038101658
-
Clinical test to confirm tracheal intubation: A new method to confirm endotracheal intubation in the absence of capnography
-
Baigel G., Safranski J. Clinical test to confirm tracheal intubation: a new method to confirm endotracheal intubation in the absence of capnography. Eur J Anaesthesiol. 2003 ; 20 (6). 475-477.
-
(2003)
Eur J Anaesthesiol
, vol.20
, Issue.6
, pp. 475-477
-
-
Baigel, G.1
Safranski, J.2
-
20
-
-
0030835933
-
Detection of accidental oesophageal intubation. Role of the anaesthetic assistant
-
Cameron AE, Hyde RA, Sivalingam P., Asbury AJ Detection of accidental oesophageal intubation. Role of the anaesthetic assistant. Anaesthesia. 1997 ; 52 (8). 733-735.
-
(1997)
Anaesthesia
, vol.52
, Issue.8
, pp. 733-735
-
-
Cameron, A.E.1
Hyde, R.A.2
Sivalingam, P.3
Asbury, A.J.4
-
21
-
-
1842298315
-
The "roll" sign for oesophageal intubation
-
Dean VS, Jurai S. -A. The "Roll" sign for oesophageal intubation sign for oesophageal intubation. Anaesthesia. 1996 ; 51 (8). 803.
-
(1996)
Anaesthesia
, vol.51
, Issue.8
, pp. 803
-
-
Dean, V.S.1
Jurai, S.2
-
22
-
-
0020348138
-
A simple maneuver to verify proper positioning of an endotracheal tube
-
Triner L. A simple maneuver to verify proper positioning of an endotracheal tube. Anesthesiology. 1982 ; 57 (6). 548-549.
-
(1982)
Anesthesiology
, vol.57
, Issue.6
, pp. 548-549
-
-
Triner, L.1
-
23
-
-
0023909058
-
An additional tactile test. Further developments in tactile tests to confirm laryngeal placement of tracheal tubes
-
Horton WA, Perera S., Charters P. An additional tactile test. Further developments in tactile tests to confirm laryngeal placement of tracheal tubes. Anaesthesia. 1988 ; 43 (2). 240-244.
-
(1988)
Anaesthesia
, vol.43
, Issue.2
, pp. 240-244
-
-
Horton, W.A.1
Perera, S.2
Charters, P.3
-
24
-
-
0029039518
-
Endotracheal tube location verified reliably by cuff palpation
-
Pollard RJ, Lobato EB Endotracheal tube location verified reliably by cuff palpation. Anesth Analg. 1995 ; 81 (1). 135-138.
-
(1995)
Anesth Analg
, vol.81
, Issue.1
, pp. 135-138
-
-
Pollard, R.J.1
Lobato, E.B.2
-
25
-
-
70349368149
-
9: Emergency department capnographic confirmation of endotracheal position in out-of-hospital cardiac arrest patients
-
Silvestri S., Ralls GA, Papa L., Huebner M., Falk J., Krauss B. 9: Emergency department capnographic confirmation of endotracheal position in out-of-hospital cardiac arrest patients. Ann Emerg Med. 2007 ; 50 (3). S4.
-
(2007)
Ann Emerg Med
, vol.50
, Issue.3
, pp. 4
-
-
Silvestri, S.1
Ralls, G.A.2
Papa, L.3
Huebner, M.4
Falk, J.5
Krauss, B.6
-
26
-
-
0020515568
-
Uneventful prolonged misdiagnosis of esophageal intubation
-
Batra AK, Cohn MA Uneventful prolonged misdiagnosis of esophageal intubation. Crit Care Med. 1983 ; 11 (9). 763-764.
-
(1983)
Crit Care Med
, vol.11
, Issue.9
, pp. 763-764
-
-
Batra, A.K.1
Cohn, M.A.2
-
27
-
-
0141926549
-
Verification of endotracheal tube placement: A comparison of confirmation techniques and devices
-
DeBoer S., Seaver M., Arndt K. Verification of endotracheal tube placement: a comparison of confirmation techniques and devices. J Emerg Nurs. 2003 ; 29 (5). 444-450.
-
(2003)
J Emerg Nurs
, vol.29
, Issue.5
, pp. 444-450
-
-
Deboer, S.1
Seaver, M.2
Arndt, K.3
-
28
-
-
84872644536
-
The unreliability of cyanosis in the recognition of arterial anoxemia
-
Comroe JH, Botelho S. The unreliability of cyanosis in the recognition of arterial anoxemia. Am J Med Sci. 1947 ; 214 (1). 1-6.
-
(1947)
Am J Med Sci
, vol.214
, Issue.1
, pp. 1-6
-
-
Comroe, J.H.1
Botelho, S.2
-
29
-
-
0023106966
-
Use of capnography and transcutaneous oxygen monitoring during outpatient general anesthesia for oral surgery
-
Anderson JA, Clark PJ, Kafer ER Use of capnography and transcutaneous oxygen monitoring during outpatient general anesthesia for oral surgery. J Oral Maxillofac Surg. 1987 ; 45 (1). 3-10.
-
(1987)
J Oral Maxillofac Surg
, vol.45
, Issue.1
, pp. 3-10
-
-
Anderson, J.A.1
Clark, P.J.2
Kafer, E.R.3
-
30
-
-
0030718592
-
Critical hemoglobin desaturation will occur before return to an unparalyzed state following 1 mg/kg intravenous succinylcholine
-
Benumof JL, Dagg R., Benumof R. Critical hemoglobin desaturation will occur before return to an unparalyzed state following 1 mg/kg intravenous succinylcholine. Anesthesiology. 1997 ; 87 (4). 979-982.
-
(1997)
Anesthesiology
, vol.87
, Issue.4
, pp. 979-982
-
-
Benumof, J.L.1
Dagg, R.2
Benumof, R.3
-
31
-
-
0024535006
-
Early detection of inadvertent oesophageal intubation: Pulse oximetry vs. capnography
-
Guggenberger H., Lenz G., Federle R. Early detection of inadvertent oesophageal intubation: pulse oximetry vs. capnography. Acta Anaesthesiol Scand. 1989 ; 33 (2). 112-115.
-
(1989)
Acta Anaesthesiol Scand
, vol.33
, Issue.2
, pp. 112-115
-
-
Guggenberger, H.1
Lenz, G.2
Federle, R.3
-
32
-
-
0023555395
-
Preoxygenation and pulse oximetry may delay detection of esophageal intubation
-
McShane AJ, Martin JL Preoxygenation and pulse oximetry may delay detection of esophageal intubation. J Natl Med Assoc. 1987 ; 79 (9). 991-992.
-
(1987)
J Natl Med Assoc
, vol.79
, Issue.9
, pp. 991-992
-
-
McShane, A.J.1
Martin, J.L.2
-
33
-
-
0029649758
-
Uses and limitations of pulse oximetry
-
Stoneham MD Uses and limitations of pulse oximetry. Br J Hosp Med. 1995 ; 54 (1). 35-41.
-
(1995)
Br J Hosp Med
, vol.54
, Issue.1
, pp. 35-41
-
-
Stoneham, M.D.1
-
34
-
-
0029124813
-
Pulse oximetry: A practical review
-
Hanning CD, Alexander-William JM Pulse oximetry: a practical review. BMJ. 1995 ; 311 (7001). 367-370.
-
(1995)
BMJ
, vol.311
, Issue.7001
, pp. 367-370
-
-
Hanning, C.D.1
Alexander-William, J.M.2
-
35
-
-
0020956492
-
Evaluation of pulse oximetry
-
Yelderman M., New W. Jr. Evaluation of pulse oximetry. Anesthesiology. 1983 ; 59 (4). 349-352.
-
(1983)
Anesthesiology
, vol.59
, Issue.4
, pp. 349-352
-
-
Yelderman, M.1
New Jr., W.2
-
36
-
-
0023133594
-
Evaluation of a flexible fiberoptic catheter in confirming endotracheal tube placement in the intensive care unit
-
Suarez M., Chediak A., Ershowsky P., Krieger B. Evaluation of a flexible fiberoptic catheter in confirming endotracheal tube placement in the intensive care unit. Respir Care. 1987 ; 32 (2). 81-84.
-
(1987)
Respir Care
, vol.32
, Issue.2
, pp. 81-84
-
-
Suarez, M.1
Chediak, A.2
Ershowsky, P.3
Krieger, B.4
-
37
-
-
0033859022
-
The role of fiberoptic bronchoscopy in airway management of the critically ill patient
-
Weiss YG, Deutschman CS The role of fiberoptic bronchoscopy in airway management of the critically ill patient. Crit Care Clin. 2000 ; 16 (3). 445-451.
-
(2000)
Crit Care Clin
, vol.16
, Issue.3
, pp. 445-451
-
-
Weiss, Y.G.1
Deutschman, C.S.2
-
38
-
-
0024344058
-
Unrecognized endobronchial intubation of emergency patients
-
Bissinger U., Lenz G., Kuhn W. Unrecognized endobronchial intubation of emergency patients. Ann Emerg Med. 1989 ; 18 (8). 853-855.
-
(1989)
Ann Emerg Med
, vol.18
, Issue.8
, pp. 853-855
-
-
Bissinger, U.1
Lenz, G.2
Kuhn, W.3
-
39
-
-
33644857673
-
-
Proceedings of the 2005 international consensus on cardiopulmonary resuscitation emergency cardiovascular care science with treatment recommendations
-
Proceedings of the 2005 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations. Resuscitation. 2005 ; 67 (2-3). 157-341.
-
(2005)
Resuscitation
, vol.67
, Issue.2-3
, pp. 157-341
-
-
-
40
-
-
43549109220
-
Capnography-Reliable technique for identifying correct tube placement in cardiac arrest endotracheal intubations
-
Grmec S. Capnography-Reliable technique for identifying correct tube placement in cardiac arrest endotracheal intubations. Resuscitation. 2008 ; 77 (3). 416-417.
-
(2008)
Resuscitation
, vol.77
, Issue.3
, pp. 416-417
-
-
Grmec, S.1
-
41
-
-
0035099882
-
Capnography alone is imperfect for endotracheal tube placement confirmation during emergency intubation
-
Li J. Capnography alone is imperfect for endotracheal tube placement confirmation during emergency intubation. J Emerg Med. 2001 ; 20 (3). 223-229.
-
(2001)
J Emerg Med
, vol.20
, Issue.3
, pp. 223-229
-
-
Li, J.1
-
42
-
-
0033845801
-
Techniques for endotracheal intubation
-
Hurford WE Techniques for endotracheal intubation. Int Anesthesiol Clin. 2000 ; 38 (3). 1-28.
-
(2000)
Int Anesthesiol Clin
, vol.38
, Issue.3
, pp. 1-28
-
-
Hurford, W.E.1
-
43
-
-
0036284052
-
Comparison of three different methods to confirm tracheal tube placement in emergency intubation
-
Grmec S. Comparison of three different methods to confirm tracheal tube placement in emergency intubation. Intensive Care Med. 2002 ; 28 (6). 701-704.
-
(2002)
Intensive Care Med
, vol.28
, Issue.6
, pp. 701-704
-
-
Grmec, S.1
-
44
-
-
0020640247
-
Capnography for detection of accidental oesophageal intubation
-
Linko K., Paloheimo M., Tammisto T. Capnography for detection of accidental oesophageal intubation. Acta Anaesthesiol Scand. 1983 ; 27 (3). 199-202.
-
(1983)
Acta Anaesthesiol Scand
, vol.27
, Issue.3
, pp. 199-202
-
-
Linko, K.1
Paloheimo, M.2
Tammisto, T.3
-
45
-
-
17844371707
-
The effectiveness of out-of-hospital use of continuous end-tidal carbon dioxide monitoring on the rate of unrecognized misplaced intubation within a regional emergency medical services system
-
Silvestri S., Ralls GA, Krauss B., et al. The effectiveness of out-of-hospital use of continuous end-tidal carbon dioxide monitoring on the rate of unrecognized misplaced intubation within a regional emergency medical services system. Ann Emerg Med. 2005 ; 45 (5). 497-503.
-
(2005)
Ann Emerg Med
, vol.45
, Issue.5
, pp. 497-503
-
-
Silvestri, S.1
Ralls, G.A.2
Krauss, B.3
-
46
-
-
43549113581
-
Capnography - Reliable technique for identifying correct tube placement in cardiac arrest endotracheal intubations
-
Nolan J. Capnography - Reliable technique for identifying correct tube placement in cardiac arrest endotracheal intubations. Resuscitation. 2008 ;Epub ahead of print.
-
(2008)
Resuscitation
-
-
Nolan, J.1
-
47
-
-
0036677235
-
Carbon dioxide monitoring in emergency medicine training programs
-
Wang VJ, Krauss B. Carbon dioxide monitoring in emergency medicine training programs. Pediatr Emerg Care. 2002 ; 18 (4). 251-253.
-
(2002)
Pediatr Emerg Care
, vol.18
, Issue.4
, pp. 251-253
-
-
Wang, V.J.1
Krauss, B.2
-
48
-
-
0028113168
-
The oesophageal detector device. An assessment of accuracy and ease of use by paramedics
-
Donahue PL The oesophageal detector device. An assessment of accuracy and ease of use by paramedics. Anaesthesia. 1994 ; 49 (10). 863-865.
-
(1994)
Anaesthesia
, vol.49
, Issue.10
, pp. 863-865
-
-
Donahue, P.L.1
-
49
-
-
0036915501
-
The tracheal detecting-bulb: A new device to distinguish tracheal from esophageal intubation
-
Tong YL, Sun M., Tang WH, Xia JY The tracheal detecting-bulb: a new device to distinguish tracheal from esophageal intubation. Acta Anaesthesiol Sin. 2002 ; 40 (4). 159-163.
-
(2002)
Acta Anaesthesiol Sin
, vol.40
, Issue.4
, pp. 159-163
-
-
Tong, Y.L.1
Sun, M.2
Tang, W.H.3
Xia, J.Y.4
-
50
-
-
0023696973
-
A method of detecting oesophageal intubation or confirming tracheal intubation
-
O'Leary JJ, Pollard BJ, Ryan MJ A method of detecting oesophageal intubation or confirming tracheal intubation. Anaesth Intensive Care. 1988 ; 16 (3). 299-301.
-
(1988)
Anaesth Intensive Care
, vol.16
, Issue.3
, pp. 299-301
-
-
O'Leary, J.J.1
Pollard, B.J.2
Ryan, M.J.3
-
51
-
-
0023896934
-
The oesophageal detector device. Assessment of a new method to distinguish oesophageal from tracheal intubation
-
Wee MY The oesophageal detector device. Assessment of a new method to distinguish oesophageal from tracheal intubation. Anaesthesia. 1988 ; 43 (1). 27-29.
-
(1988)
Anaesthesia
, vol.43
, Issue.1
, pp. 27-29
-
-
Wee, M.Y.1
-
52
-
-
0036590732
-
The esophageal detector bulb in the aeromedical setting
-
Hendey GW, Shubert GS, Shalit M., Hogue B. The esophageal detector bulb in the aeromedical setting. J Emerg Med. 2002 ; 23 (1). 51-55.
-
(2002)
J Emerg Med
, vol.23
, Issue.1
, pp. 51-55
-
-
Hendey, G.W.1
Shubert, G.S.2
Shalit, M.3
Hogue, B.4
-
53
-
-
0025775535
-
The oesophageal detector device
-
Baraka A. The oesophageal detector device. Anaesthesia. 1991 ; 46 (8). 697.
-
(1991)
Anaesthesia
, vol.46
, Issue.8
, pp. 697
-
-
Baraka, A.1
-
54
-
-
0027268516
-
The esophageal detector device in the morbidly obese
-
Baraka A., Choueiry P., Salem R. The esophageal detector device in the morbidly obese. Anesth Analag. 1993 ; 77 (2). 400.
-
(1993)
Anesth Analag
, vol.77
, Issue.2
, pp. 400
-
-
Baraka, A.1
Choueiry, P.2
Salem, R.3
-
55
-
-
0031058123
-
Efficacy of the self-inflating bulb in differentiating esophageal from tracheal intubation in the parturient undergoing cesarean section
-
DOI 10.1097/00000539-199703000-00012
-
Baraka A., Khoury PJ, Siddik SS, Salem MR, Joseph NJ Efficacy of the self-inflating bulb in differentiating esophageal from tracheal intubation in the parturient undergoing cesarean section. Anesth Analg. 1997 ; 84 (3). 533-537. (Pubitemid 27100384)
-
(1997)
Anesthesia and Analgesia
, vol.84
, Issue.3
, pp. 533-537
-
-
Baraka, A.1
Khoury, P.J.2
Siddik, S.S.3
Salem, M.R.4
Joseph, N.J.5
-
56
-
-
0025849044
-
Confirmation of correct endotracheal tube placement
-
Smith I. Confirmation of correct endotracheal tube placement. Anaesth Analg. 1991 ; 72 (2). 263.
-
(1991)
Anaesth Analg
, vol.72
, Issue.2
, pp. 263
-
-
Smith, I.1
-
57
-
-
0032820217
-
The esophageal detector device is unreliable when the stomach has been ventilated
-
Andres AH, Langenstein H. The esophageal detector device is unreliable when the stomach has been ventilated. Anesthesiology. 1999 ; 91 (2). 566-568.
-
(1999)
Anesthesiology
, vol.91
, Issue.2
, pp. 566-568
-
-
Andres, A.H.1
Langenstein, H.2
-
58
-
-
0029790278
-
Efficacy of the self-inflating bulb in confirming tracheal intubation in the morbidly obese
-
Lang DJ, Wafai U., Salem MR, Czinn EA, Halim AA, Baraka A. Efficacy of the self-inflating bulb in confirming tracheal intubation in the morbidly obese. Anesthesiology. 1996 ; 85: 246-253.
-
(1996)
Anesthesiology
, vol.85
, pp. 246-253
-
-
Lang, D.J.1
Wafai, U.2
Salem, M.R.3
Czinn, E.A.4
Halim, A.A.5
Baraka, A.6
-
59
-
-
0036137555
-
Evaluation of an electronic esophageal detector device in patients with morbid obesity and pulmonary failure
-
Wolfe TR, Kimball EJ, Ogden LL, et al. Evaluation of an electronic esophageal detector device in patients with morbid obesity and pulmonary failure. Prehosp Emerg Care. 2002 ; 6 (1). 59-64.
-
(2002)
Prehosp Emerg Care
, vol.6
, Issue.1
, pp. 59-64
-
-
Wolfe, T.R.1
Kimball, E.J.2
Ogden, L.L.3
-
60
-
-
0023513657
-
Use of a lighted stylet to confirm correct endotracheal tube placement
-
Stewart RD, LaRosee A., Stoy WA, Heller MB Use of a lighted stylet to confirm correct endotracheal tube placement. Chest. 1987 ; 92 (5). 900-903.
-
(1987)
Chest
, vol.92
, Issue.5
, pp. 900-903
-
-
Stewart, R.D.1
Larosee, A.2
Stoy, W.A.3
Heller, M.B.4
-
61
-
-
0024802993
-
Transtracheal illumination for optimal tracheal tube placement
-
Mehta S. Transtracheal illumination for optimal tracheal tube placement. A clinical study. Anaesthesia. 1989 ; 44 (12). 970-972.
-
(1989)
A Clinical Study. Anaesthesia
, vol.44
, Issue.12
, pp. 970-972
-
-
Mehta, S.1
-
62
-
-
18144378492
-
Breath sound changes associated with malpositioned endotracheal tubes
-
Mansy HA, O'Connor CJ, Balk RA, Sandler RH Breath sound changes associated with malpositioned endotracheal tubes. Med Biol Eng Comput. 2005 ; 43 (2). 206-211.
-
(2005)
Med Biol Eng Comput
, vol.43
, Issue.2
, pp. 206-211
-
-
Mansy, H.A.1
O'Connor, C.J.2
Balk, R.A.3
Sandler, R.H.4
-
63
-
-
23944466588
-
Identification of endotracheal tube malpositions using computerized analysis of breath sounds via electronic stethoscopes
-
O'Connor CJ, Mansy H., Balk RA, Tuman KJ, Sandler RH Identification of endotracheal tube malpositions using computerized analysis of breath sounds via electronic stethoscopes. Anesth Analg. 2005 ; 101 (3). 735-739.
-
(2005)
Anesth Analg
, vol.101
, Issue.3
, pp. 735-739
-
-
O'Connor, C.J.1
Mansy, H.2
Balk, R.A.3
Tuman, K.J.4
Sandler, R.H.5
-
64
-
-
0031973770
-
Airway auscultation. A new method of confirming tracheal intubation
-
Nicoll SJ, King CJ Airway auscultation. A new method of confirming tracheal intubation. Anaesthesia. 1998 ; 53 (1). 41-45.
-
(1998)
Anaesthesia
, vol.53
, Issue.1
, pp. 41-45
-
-
Nicoll, S.J.1
King, C.J.2
-
65
-
-
0031898108
-
Portable devices used to detect endotracheal intubation during emergency situations: A review
-
Cardoso MM, Banner MJ, Melker RJ, Bjoraker DG Portable devices used to detect endotracheal intubation during emergency situations: a review. Crit Care Med. 1998 ; 26 (5). 957-964.
-
(1998)
Crit Care Med
, vol.26
, Issue.5
, pp. 957-964
-
-
Cardoso, M.M.1
Banner, M.J.2
Melker, R.J.3
Bjoraker, D.G.4
-
66
-
-
0031044163
-
SCOTI vs. Wee: An assessment of two oesophageal intubation detection devices
-
Lockey DJ, Woodward W. SCOTI vs. Wee: an assessment of two oesophageal intubation detection devices. Anaesthesia. 1997 ; 52 (3). 242-243.
-
(1997)
Anaesthesia
, vol.52
, Issue.3
, pp. 242-243
-
-
Lockey, D.J.1
Woodward, W.2
-
67
-
-
0034097390
-
Acoustic reflectometry profiles of endotracheal and esophageal intubation
-
Raphael DT Acoustic reflectometry profiles of endotracheal and esophageal intubation. Anesthesiology. 2000 ; 92 (5). 1293-1299.
-
(2000)
Anesthesiology
, vol.92
, Issue.5
, pp. 1293-1299
-
-
Raphael, D.T.1
-
68
-
-
38449086688
-
Detection of oesophageal intubations using cuff pressures in a pig trachea oesophagus model
-
Lin HJ, Chen KT, Foo NP, Hsu CC, Guo HR Detection of oesophageal intubations using cuff pressures in a pig trachea oesophagus model. Br J Anaesth. 2007 ; 99 (5). 740-743.
-
(2007)
Br J Anaesth
, vol.99
, Issue.5
, pp. 740-743
-
-
Lin, H.J.1
Chen, K.T.2
Foo, N.P.3
Hsu, C.C.4
Guo, H.R.5
-
69
-
-
0024060048
-
Cuff seal volumes and oesophageal intubation
-
Jarvis D., Russell WJ Cuff seal volumes and oesophageal intubation. Anaesth Intensive Care. 1988 ; 16 (3). 378.
-
(1988)
Anaesth Intensive Care
, vol.16
, Issue.3
, pp. 378
-
-
Jarvis, D.1
Russell, W.J.2
-
70
-
-
25144505286
-
An assessment of a tracheal tube introducer as an endotracheal tube placement confirmation device
-
Bair AE, Laurin EG, Schmitt BJ An assessment of a tracheal tube introducer as an endotracheal tube placement confirmation device. Am J Emerg Med. 2005 ; 23 (6). 754-758.
-
(2005)
Am J Emerg Med
, vol.23
, Issue.6
, pp. 754-758
-
-
Bair, A.E.1
Laurin, E.G.2
Schmitt, B.J.3
-
71
-
-
0030110760
-
Neural network-based detection of esophageal intubation in anesthetized patients
-
León MA, Räsänen J. Neural network-based detection of esophageal intubation in anesthetized patients. J Clin Monit. 1996 ; 12 (2). 165-169.
-
(1996)
J Clin Monit
, vol.12
, Issue.2
, pp. 165-169
-
-
León, M.A.1
Räsänen, J.2
-
72
-
-
0028221011
-
Neural network based detection of esophageal intubation
-
León MA, Räsänen J., Mangar D. Neural network based detection of esophageal intubation. Anesth Analg. 1994 ; 78 (3). 548-553.
-
(1994)
Anesth Analg
, vol.78
, Issue.3
, pp. 548-553
-
-
León, M.A.1
Räsänen, J.2
Mangar, D.3
-
73
-
-
0016402779
-
Respiratory recording from the oesophagus (letter)
-
Robinson JS Respiratory recording from the oesophagus (letter). BMJ. 1974 ; 4 (5938). 225.
-
(1974)
BMJ
, vol.4
, Issue.5938
, pp. 225
-
-
Robinson, J.S.1
-
74
-
-
0036844593
-
An assessment of the ability of impedance respirometry to distinguish oesophageal from tracheal intubation
-
Mehta KH, Turley A., Peyrasse P., Janes J., Hall JE An assessment of the ability of impedance respirometry to distinguish oesophageal from tracheal intubation. Anaesthesia. 2002 ; 57 (11). 1090-1093.
-
(2002)
Anaesthesia
, vol.57
, Issue.11
, pp. 1090-1093
-
-
Mehta, K.H.1
Turley, A.2
Peyrasse, P.3
Janes, J.4
Hall, J.E.5
-
75
-
-
33750735374
-
The use of impedance respirometry to confirm tracheal intubation in children
-
Absolom M., Roberts R., Bahlmann UB, Hall JE, Armstrong T., Turley A. The use of impedance respirometry to confirm tracheal intubation in children. Anaesthesia. 2006 ; 61 (12). 1145-1148.
-
(2006)
Anaesthesia
, vol.61
, Issue.12
, pp. 1145-1148
-
-
Absolom, M.1
Roberts, R.2
Bahlmann, U.B.3
Hall, J.E.4
Armstrong, T.5
Turley, A.6
-
76
-
-
36849015385
-
Transthoracic impedance changes as a tool to detect malpositioned tracheal tubes
-
Kramer-Johansen J., Eilevstjønn J., Olasveengen TM, Tomlinson AE, Dorph E., Steen PA Transthoracic impedance changes as a tool to detect malpositioned tracheal tubes. Resuscitation. 2008 ; 76 (1). 11-16.
-
(2008)
Resuscitation
, vol.76
, Issue.1
, pp. 11-16
-
-
Kramer-Johansen, J.1
Eilevstjønn, J.2
Olasveengen, T.M.3
Tomlinson, A.E.4
Dorph, E.5
Steen, P.A.6
-
77
-
-
43549113118
-
Detection of malintubation via defibrillator pads
-
Kohler KW, Losert H., Myklebust H., et al. Detection of malintubation via defibrillator pads. Resuscitation. 2008 ; 77 (3). 339-344.
-
(2008)
Resuscitation
, vol.77
, Issue.3
, pp. 339-344
-
-
Kohler, K.W.1
Losert, H.2
Myklebust, H.3
-
78
-
-
33750068307
-
Model-based detection of endobronchial intubation
-
Visaria RK, Westenskow DR Model-based detection of endobronchial intubation. Anesth Analg. 2006 ; 103 (4). 888-893.
-
(2006)
Anesth Analg
, vol.103
, Issue.4
, pp. 888-893
-
-
Visaria, R.K.1
Westenskow, D.R.2
-
79
-
-
34247347848
-
Role of ultrasound in the airway management of critically ill patients
-
Sustić A. Role of ultrasound in the airway management of critically ill patients. Crit Care Med. 2007 ; 35 (5 suppl). S173 - S177.
-
(2007)
Crit Care Med
, vol.35
, Issue.5 SUPPL
-
-
Sustić, A.1
-
80
-
-
0034981740
-
Ultrasonographic evaluation of diaphragmatic motion
-
Gerscovich EO, Cronan M., McGahan JP, Jain K., Jones CD, McDonald C. Ultrasonographic evaluation of diaphragmatic motion. J Ultrasound Med. 2001 ; 20 (6). 597-604.
-
(2001)
J Ultrasound Med
, vol.20
, Issue.6
, pp. 597-604
-
-
Gerscovich, E.O.1
Cronan, M.2
McGahan, J.P.3
Jain, K.4
Jones, C.D.5
McDonald, C.6
-
81
-
-
0027395186
-
Imaging of the pleura
-
Müller NL Imaging of the pleura. Radiology. 1993 ; 186 (2). 297-309.
-
(1993)
Radiology
, vol.186
, Issue.2
, pp. 297-309
-
-
Müller, N.L.1
-
82
-
-
0028881178
-
A bedside ultrasound sign ruling out pneumothorax in the critically ill: Lung sliding
-
Lichtenstein DA, Menu Y. A bedside ultrasound sign ruling out pneumothorax in the critically ill: lung sliding. Chest. 1995 ; 108 (5). 1345-1348.
-
(1995)
Chest
, vol.108
, Issue.5
, pp. 1345-1348
-
-
Lichtenstein, D.A.1
Menu, Y.2
-
83
-
-
7244255763
-
Secondary confirmation of endotracheal tube position by ultrasound image
-
Hsieh KS, Lee CL, Lin CC, Huang TC, Weng KP, Lu WH Secondary confirmation of endotracheal tube position by ultrasound image. Crit Care Med. 2004 ; 32: S374 - S377.
-
(2004)
Crit Care Med
, vol.32
-
-
Hsieh, K.S.1
Lee, C.L.2
Lin, C.C.3
Huang, T.C.4
Weng, K.P.5
Lu, W.H.6
-
84
-
-
0346964475
-
The "lung pulse": An early ultrasound sign of complete atelectasis
-
Lichtenstein DA, Lascols N., Prin S., Mezière G. The "lung pulse": An early ultrasound sign of complete atelectasis. Intensive Care Med. 2003 ; 29 (12). 2187-2192.
-
(2003)
Intensive Care Med
, vol.29
, Issue.12
, pp. 2187-2192
-
-
Lichtenstein, D.A.1
Lascols, N.2
Prin, S.3
Mezière, G.4
-
85
-
-
13744251530
-
Where's the tube? Evaluation of hand-held ultrasound in confirming endotracheal tube placement
-
Chun R., Kirkpatrick AW, Sirois M., et al. Where's the tube? Evaluation of hand-held ultrasound in confirming endotracheal tube placement. Prehosp Disaster Med. 2004 ; 19 (4). 366-369.
-
(2004)
Prehosp Disaster Med
, vol.19
, Issue.4
, pp. 366-369
-
-
Chun, R.1
Kirkpatrick, A.W.2
Sirois, M.3
-
86
-
-
33845599615
-
Ultrasound-guided percutaneous dilatational tracheostomy
-
Sustic A. Ultrasound-guided percutaneous dilatational tracheostomy. J Anästhesie Intensivbehandlung. 2006 ; 13 (Suppl): S32 - S44.
-
(2006)
J Anästhesie Intensivbehandlung
, vol.13
-
-
Sustic, A.1
-
87
-
-
0032759671
-
Ultrasound: An emerging role in anaesthesia and intensive care
-
Hatfield A., Bodenham A. Ultrasound: an emerging role in anaesthesia and intensive care. Br J Anaesth. 1999 ; 83 (5). 789-800.
-
(1999)
Br J Anaesth
, vol.83
, Issue.5
, pp. 789-800
-
-
Hatfield, A.1
Bodenham, A.2
-
88
-
-
0023628368
-
Ultrasound confirmation of endotracheal tube placement
-
Raphael DT, Conard FU 3rd. Ultrasound confirmation of endotracheal tube placement. J Clin Ultrasound. 1987 ; 15 (7). 459-462.
-
(1987)
J Clin Ultrasound
, vol.15
, Issue.7
, pp. 459-462
-
-
Raphael, D.T.1
Conard III, F.U.2
-
89
-
-
33845795275
-
Pilot study to evaluate the accuracy of ultrasonography in confirming endotracheal tube placement
-
Werner SL, Smith CE, Goldstein JR, Jones RA, Cydulka RK Pilot study to evaluate the accuracy of ultrasonography in confirming endotracheal tube placement. Ann Emerg Med. 2007 ; 49 (1). 75-80.
-
(2007)
Ann Emerg Med
, vol.49
, Issue.1
, pp. 75-80
-
-
Werner, S.L.1
Smith, C.E.2
Goldstein, J.R.3
Jones, R.A.4
Cydulka, R.K.5
-
90
-
-
34248175803
-
The sensitivity and specificity of transcricothyroid ultrasonography to confirm endotracheal tube placement in a cadaver model
-
Ma G., Davis DP, Schmitt J., Vilke GM, Chan TC, Hayden SR The sensitivity and specificity of transcricothyroid ultrasonography to confirm endotracheal tube placement in a cadaver model. J Emerg Med. 2007 ; 32 (4). 405-407.
-
(2007)
J Emerg Med
, vol.32
, Issue.4
, pp. 405-407
-
-
Ma, G.1
Davis, D.P.2
Schmitt, J.3
Vilke, G.M.4
Chan, T.C.5
Hayden, S.R.6
-
91
-
-
7244255763
-
Secondary confirmation of endotracheal tube position by ultrasound image
-
Hsieh KS, Lee CL, Lin CC, et al. Secondary confirmation of endotracheal tube position by ultrasound image. Crit Care Med. 2004 ; 32 (9 suppl). S374 - S377.
-
(2004)
Crit Care Med
, vol.32
, Issue.9
-
-
Hsieh, K.S.1
Lee, C.L.2
Lin, C.C.3
|