메뉴 건너뛰기




Volumn 89, Issue C, 2015, Pages 188-194

Video laryngoscopy improves the first-attempt success in endotracheal intubation during cardiopulmonary resuscitation among novice physicians

Author keywords

Cardiopulmonary resuscitation; Endotracheal intubation; High frequency chest compression; Interruption; Video laryngoscopy

Indexed keywords

ADULT; ARTICLE; COMPARATIVE EFFECTIVENESS; CONTROLLED STUDY; EMERGENCY PHYSICIAN; ENDOTRACHEAL INTUBATION; ESOPHAGUS INTUBATION; FEMALE; HUMAN; INCIDENCE; LARYNGOSCOPY; MAJOR CLINICAL STUDY; MALE; OUT OF HOSPITAL CARDIAC ARREST; OUTCOME ASSESSMENT; PRIORITY JOURNAL; RESUSCITATION; VIDEO LARYNGOSCOPY; VIDEOLARYNGOSCOPE; AGED; CLINICAL COMPETENCE; ENDOSCOPIC SURGERY; EPIDEMIOLOGY; HEART ARREST; MIDDLE AGED; RETROSPECTIVE STUDY; STATISTICAL MODEL;

EID: 84927689825     PISSN: 03009572     EISSN: 18731570     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2014.12.010     Document Type: Article
Times cited : (52)

References (27)
  • 1
    • 78651246812 scopus 로고    scopus 로고
    • Part 8: advanced life support: 2010 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations
    • Deakin C.D., Morrison L.J., Morley P.T., et al. Part 8: advanced life support: 2010 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations. Resuscitation 2010, 81:e93-e174.
    • (2010) Resuscitation , vol.81 , pp. e93-e174
    • Deakin, C.D.1    Morrison, L.J.2    Morley, P.T.3
  • 2
    • 78049478848 scopus 로고    scopus 로고
    • European resuscitation council guidelines for resuscitation 2010 section 4. Adult advanced life support
    • Deakin C.D., Nolan J.P., Soar J., et al. European resuscitation council guidelines for resuscitation 2010 section 4. Adult advanced life support. Resuscitation 2010, 81:1305-1352.
    • (2010) Resuscitation , vol.81 , pp. 1305-1352
    • Deakin, C.D.1    Nolan, J.P.2    Soar, J.3
  • 3
    • 0035148486 scopus 로고    scopus 로고
    • Misplaced endotracheal tubes by paramedics in an urban emergency medical services system
    • Katz S.H., Falk J.L. Misplaced endotracheal tubes by paramedics in an urban emergency medical services system. Ann Emerg Med 2001, 37:32-37.
    • (2001) Ann Emerg Med , vol.37 , pp. 32-37
    • Katz, S.H.1    Falk, J.L.2
  • 4
    • 70350048929 scopus 로고    scopus 로고
    • Interruptions in cardiopulmonary resuscitation from paramedic endotracheal intubation
    • 645,652.e1
    • Wang H.E., Simeone S.J., Weaver M.D., Callaway C.W. Interruptions in cardiopulmonary resuscitation from paramedic endotracheal intubation. Ann Emerg Med 2009, 54. 645,652.e1.
    • (2009) Ann Emerg Med , vol.54
    • Wang, H.E.1    Simeone, S.J.2    Weaver, M.D.3    Callaway, C.W.4
  • 6
    • 84855794977 scopus 로고    scopus 로고
    • Developing the skill of endotracheal intubation: implication for emergency medicine
    • Bernhard M., Mohr S., Weigand M.A., Martin E., Walther A. Developing the skill of endotracheal intubation: implication for emergency medicine. Acta Anaesthesiol Scand 2012, 56:164-171.
    • (2012) Acta Anaesthesiol Scand , vol.56 , pp. 164-171
    • Bernhard, M.1    Mohr, S.2    Weigand, M.A.3    Martin, E.4    Walther, A.5
  • 7
    • 84878448946 scopus 로고    scopus 로고
    • Review article: video-laryngoscopy: another tool for difficult intubation or a new paradigm in airway management?
    • Paolini J.B., Donati F., Drolet P. Review article: video-laryngoscopy: another tool for difficult intubation or a new paradigm in airway management?. Can J Anaesth 2013, 60:184-191.
    • (2013) Can J Anaesth , vol.60 , pp. 184-191
    • Paolini, J.B.1    Donati, F.2    Drolet, P.3
  • 8
    • 11444255353 scopus 로고    scopus 로고
    • The glidescope system: a clinical assessment of performance
    • Rai M.R., Dering A., Verghese C. The glidescope system: a clinical assessment of performance. Anaesthesia 2005, 60:60-64.
    • (2005) Anaesthesia , vol.60 , pp. 60-64
    • Rai, M.R.1    Dering, A.2    Verghese, C.3
  • 9
    • 77955299730 scopus 로고    scopus 로고
    • Improved glottic exposure with the Video Macintosh Laryngoscope in adult emergency department tracheal intubations
    • National Emergency Airway Registry (NEAR) Investigators
    • Brown C.A., Bair A.E., Pallin D.J., Laurin E.G., Walls R.M. Improved glottic exposure with the Video Macintosh Laryngoscope in adult emergency department tracheal intubations. Ann Emerg Med 2010, 56:83-88. National Emergency Airway Registry (NEAR) Investigators.
    • (2010) Ann Emerg Med , vol.56 , pp. 83-88
    • Brown, C.A.1    Bair, A.E.2    Pallin, D.J.3    Laurin, E.G.4    Walls, R.M.5
  • 10
    • 0036971143 scopus 로고    scopus 로고
    • A new video laryngoscope-an aid to intubation and teaching
    • Kaplan M.B., Ward D.S., Berci G. A new video laryngoscope-an aid to intubation and teaching. J Clin Anaesth 2002, 14:620-626.
    • (2002) J Clin Anaesth , vol.14 , pp. 620-626
    • Kaplan, M.B.1    Ward, D.S.2    Berci, G.3
  • 11
    • 58749099150 scopus 로고    scopus 로고
    • Laryngoscopy via Macintosh blade versus GlideScope: success rate and time for endotracheal intubation in untrained medical personnel
    • Nouruzi-Sedeh P., Schumann M., Groeben H. Laryngoscopy via Macintosh blade versus GlideScope: success rate and time for endotracheal intubation in untrained medical personnel. Anesthesiology 2009, 110:32-37.
    • (2009) Anesthesiology , vol.110 , pp. 32-37
    • Nouruzi-Sedeh, P.1    Schumann, M.2    Groeben, H.3
  • 12
    • 72049107444 scopus 로고    scopus 로고
    • Utility of the Pentax-AWS without interruption of chest compression: comparison of the Macintosh laryngoscope with the Pentax-AWS in manikin model
    • Han S.K., Shin D.H., Choi P.C. Utility of the Pentax-AWS without interruption of chest compression: comparison of the Macintosh laryngoscope with the Pentax-AWS in manikin model. Resuscitation 2010, 81:69-73.
    • (2010) Resuscitation , vol.81 , pp. 69-73
    • Han, S.K.1    Shin, D.H.2    Choi, P.C.3
  • 13
    • 84882852111 scopus 로고    scopus 로고
    • Tracheal intubation during chest compressions performed by qualified emergency physicians unfamiliar with the Pentax-Airwayscope
    • Shin D.H., Han S.K., Choi P.C., Sim M.S., Lee J.H., Park S.O. Tracheal intubation during chest compressions performed by qualified emergency physicians unfamiliar with the Pentax-Airwayscope. Eur J Emerg Med 2012.
    • (2012) Eur J Emerg Med
    • Shin, D.H.1    Han, S.K.2    Choi, P.C.3    Sim, M.S.4    Lee, J.H.5    Park, S.O.6
  • 14
    • 84882884288 scopus 로고    scopus 로고
    • Feasibility of the video-laryngoscope (GlideScope(R)) for endotracheal intubation during uninterrupted chest compressions in actual advanced life support: a clinical observational study in an urban emergency department
    • Park S.O., Baek K.J., Hong D.Y., Kim S.C., Lee K.R. Feasibility of the video-laryngoscope (GlideScope(R)) for endotracheal intubation during uninterrupted chest compressions in actual advanced life support: a clinical observational study in an urban emergency department. Resuscitation 2013, 84:1233-1237.
    • (2013) Resuscitation , vol.84 , pp. 1233-1237
    • Park, S.O.1    Baek, K.J.2    Hong, D.Y.3    Kim, S.C.4    Lee, K.R.5
  • 15
    • 79952629483 scopus 로고    scopus 로고
    • Glidescope((R)) videolaryngoscope improves intubation success rate in cardiac arrest scenarios without chest compressions interruption: a randomized cross-over manikin study
    • Xanthos T., Stroumpoulis K., Bassiakou E., et al. Glidescope((R)) videolaryngoscope improves intubation success rate in cardiac arrest scenarios without chest compressions interruption: a randomized cross-over manikin study. Resuscitation 2011, 82:464-467.
    • (2011) Resuscitation , vol.82 , pp. 464-467
    • Xanthos, T.1    Stroumpoulis, K.2    Bassiakou, E.3
  • 16
    • 79960469950 scopus 로고    scopus 로고
    • Tracheal intubation during chest compressions using Pentax-AWS((R)), GlideScope ((R)), and Macintosh laryngoscope: a randomized crossover trial using a mannequin
    • Shin D.H., Choi P.C., Han S.K. Tracheal intubation during chest compressions using Pentax-AWS((R)), GlideScope ((R)), and Macintosh laryngoscope: a randomized crossover trial using a mannequin. Can J Anesth 2011, 58:733-739.
    • (2011) Can J Anesth , vol.58 , pp. 733-739
    • Shin, D.H.1    Choi, P.C.2    Han, S.K.3
  • 17
    • 0344653608 scopus 로고    scopus 로고
    • Learning manual skills in anesthesiology: is there a recommended number of cases for anesthetic procedures?
    • Konrad C., Schupfer G., Wietlisbach M., Gerber H. Learning manual skills in anesthesiology: is there a recommended number of cases for anesthetic procedures?. Anesth Analg 1998, 86:635-639.
    • (1998) Anesth Analg , vol.86 , pp. 635-639
    • Konrad, C.1    Schupfer, G.2    Wietlisbach, M.3    Gerber, H.4
  • 18
    • 0037223845 scopus 로고    scopus 로고
    • Laryngoscopic intubation: learning and performance
    • Mulcaster J.T., Mills J., Hung O.R., et al. Laryngoscopic intubation: learning and performance. Anesthesiology 2003, 98:23-27.
    • (2003) Anesthesiology , vol.98 , pp. 23-27
    • Mulcaster, J.T.1    Mills, J.2    Hung, O.R.3
  • 19
    • 84877748980 scopus 로고    scopus 로고
    • Airway management in cardiopulmonary resuscitation
    • Soar J., Nolan J.P. Airway management in cardiopulmonary resuscitation. Curr Opin Crit Care 2013, 19:181-187.
    • (2013) Curr Opin Crit Care , vol.19 , pp. 181-187
    • Soar, J.1    Nolan, J.P.2
  • 20
    • 57349173574 scopus 로고    scopus 로고
    • Comparison of the Glidescope, the Pentax AWS, and the Truview EVO2 with the Macintosh laryngoscope in experienced anaesthetists: a manikin study
    • Malik M.A., O'Donoghue C., Carney J., Maharaj C.H., Harte B.H., Laffey J.G. Comparison of the Glidescope, the Pentax AWS, and the Truview EVO2 with the Macintosh laryngoscope in experienced anaesthetists: a manikin study. Br J Anaesth 2009, 102:128-134.
    • (2009) Br J Anaesth , vol.102 , pp. 128-134
    • Malik, M.A.1    O'Donoghue, C.2    Carney, J.3    Maharaj, C.H.4    Harte, B.H.5    Laffey, J.G.6
  • 21
    • 79960839973 scopus 로고    scopus 로고
    • The C-MAC videolaryngoscope for prehospital emergency intubation: a prospective, multicentre, observational study
    • Cavus E., Callies A., Doerges V., et al. The C-MAC videolaryngoscope for prehospital emergency intubation: a prospective, multicentre, observational study. Emerg Med J 2011, 28:650-653.
    • (2011) Emerg Med J , vol.28 , pp. 650-653
    • Cavus, E.1    Callies, A.2    Doerges, V.3
  • 22
    • 84867818799 scopus 로고    scopus 로고
    • Videolaryngoscopy: should it replace direct laryngoscopy? a pro-con debate
    • Rothfield K.P., Russo S.G. Videolaryngoscopy: should it replace direct laryngoscopy? a pro-con debate. J Clin Anesth 2012, 24:593-597.
    • (2012) J Clin Anesth , vol.24 , pp. 593-597
    • Rothfield, K.P.1    Russo, S.G.2
  • 23
    • 84890433980 scopus 로고    scopus 로고
    • Comparative analysis of airway scope and Macintosh laryngoscope for intubation primarily for cardiac arrest in prehospital setting
    • Arima T., Nagata O., Miura T., et al. Comparative analysis of airway scope and Macintosh laryngoscope for intubation primarily for cardiac arrest in prehospital setting. Am J Emerg Med 2014, 32:40-43.
    • (2014) Am J Emerg Med , vol.32 , pp. 40-43
    • Arima, T.1    Nagata, O.2    Miura, T.3
  • 24
    • 84859711768 scopus 로고    scopus 로고
    • Tracheal intubation in the emergency department: a comparison of GlideScope(R) video laryngoscopy to direct laryngoscopy in 822 intubations
    • Sakles J.C., Mosier J.M., Chiu S., Keim S.M. Tracheal intubation in the emergency department: a comparison of GlideScope(R) video laryngoscopy to direct laryngoscopy in 822 intubations. J Emerg Med 2012, 42:400-405.
    • (2012) J Emerg Med , vol.42 , pp. 400-405
    • Sakles, J.C.1    Mosier, J.M.2    Chiu, S.3    Keim, S.M.4
  • 26
    • 84889679672 scopus 로고    scopus 로고
    • Endotracheal intubation with the GlideScope(R), the Airtraq(R), the McGrath(R) videolaryngoscope and direct laryngoscopy: a comparative study on an infant manikin
    • Orliaguet G.A., Blot R.M., Bourdaud N., et al. Endotracheal intubation with the GlideScope(R), the Airtraq(R), the McGrath(R) videolaryngoscope and direct laryngoscopy: a comparative study on an infant manikin. Ann Fr Anesth Reanim 2013, 32:844-849.
    • (2013) Ann Fr Anesth Reanim , vol.32 , pp. 844-849
    • Orliaguet, G.A.1    Blot, R.M.2    Bourdaud, N.3
  • 27
    • 33846644972 scopus 로고    scopus 로고
    • Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope
    • Jones P.M., Turkstra T.P., Armstrong K.P., et al. Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope. Can J Anaesth 2007, 54:21-27.
    • (2007) Can J Anaesth , vol.54 , pp. 21-27
    • Jones, P.M.1    Turkstra, T.P.2    Armstrong, K.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.