메뉴 건너뛰기




Volumn 82, Issue 4, 2011, Pages 464-467

Glidescope® videolaryngoscope improves intubation success rate in cardiac arrest scenarios without chest compressions interruption: A randomized cross-over manikin study

Author keywords

Cardiopulmonary resuscitation; Glidescope ; Intubation time; Macintosh; Manikin; Success rate

Indexed keywords

AIRWAY; ARTICLE; AUDIOVISUAL EQUIPMENT; COMPRESSION THERAPY; CONTROLLED STUDY; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; HEART ARREST; HUMAN; INTUBATION; LARYNGOSCOPE; MEDICAL EDUCATION; PERFORMANCE; PHYSICIAN; PRIORITY JOURNAL; RESUSCITATION; TREATMENT DURATION; TREATMENT OUTCOME; VIDEOLARYNGOSCOPE;

EID: 79952629483     PISSN: 03009572     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2010.12.011     Document Type: Article
Times cited : (32)

References (34)
  • 1
    • 0141866906 scopus 로고    scopus 로고
    • Automated external defibrillation versus manual defibrillation for prolonged ventricular fibrillation: lethal delays of chest compressions before and after countershocks
    • Berg R.A., Hilwig R.W., Kern K.B., Sanders A.B., Xavier L.C., Ewy G.A. Automated external defibrillation versus manual defibrillation for prolonged ventricular fibrillation: lethal delays of chest compressions before and after countershocks. Ann Emerg Med 2003, 42:458-467.
    • (2003) Ann Emerg Med , vol.42 , pp. 458-467
    • Berg, R.A.1    Hilwig, R.W.2    Kern, K.B.3    Sanders, A.B.4    Xavier, L.C.5    Ewy, G.A.6
  • 2
    • 0037022212 scopus 로고    scopus 로고
    • Importance of continuous chest compressions during cardiopulmonary resuscitation: improved outcome during a simulated single lay-rescuer scenario
    • Kern K.B., Hilwig R.W., Berg R.A., Sanders A.B., Ewy G.A. Importance of continuous chest compressions during cardiopulmonary resuscitation: improved outcome during a simulated single lay-rescuer scenario. Circulation 2002, 105:645-649.
    • (2002) Circulation , vol.105 , pp. 645-649
    • Kern, K.B.1    Hilwig, R.W.2    Berg, R.A.3    Sanders, A.B.4    Ewy, G.A.5
  • 3
    • 78049478848 scopus 로고    scopus 로고
    • European Resuscitation Council Guidelines for Resuscitation 2010. Section 4. Adult advanced life support
    • Deakin C.D., Nolan J.P., Soar J., et al. European Resuscitation Council Guidelines for Resuscitation 2010. Section 4. Adult advanced life support. Resuscitation 2010, 81:1305-1352.
    • (2010) Resuscitation , vol.81 , pp. 1305-1352
    • Deakin, C.D.1    Nolan, J.P.2    Soar, J.3
  • 4
    • 40949105091 scopus 로고    scopus 로고
    • Effect of chest compressions on the time taken to insert airway devices in a manikin
    • Gatward J.J., Thomas M.J.C., Nolan J.P., Cook T.M. Effect of chest compressions on the time taken to insert airway devices in a manikin. Br J Anaesth 2008, 100:351-356.
    • (2008) Br J Anaesth , vol.100 , pp. 351-356
    • Gatward, J.J.1    Thomas, M.J.C.2    Nolan, J.P.3    Cook, T.M.4
  • 5
    • 23844438595 scopus 로고    scopus 로고
    • Should emergency medical service rescuers be trained to practice endotracheal intubation?
    • Gerbeaux P. Should emergency medical service rescuers be trained to practice endotracheal intubation?. Crit Care Med 2005, 33:1864-1865.
    • (2005) Crit Care Med , vol.33 , pp. 1864-1865
    • Gerbeaux, P.1
  • 6
    • 0037223845 scopus 로고    scopus 로고
    • Laryngoscopic intubation: learning and performance
    • Mulcaster J.T., Mills J., Hung O.R., et al. Laryngoscopic intubation: learning and performance. Anesthesiology 2003, 98:23-27.
    • (2003) Anesthesiology , vol.98 , pp. 23-27
    • Mulcaster, J.T.1    Mills, J.2    Hung, O.R.3
  • 7
    • 16344374081 scopus 로고    scopus 로고
    • Early clinical experience with a new videolaryngoscope (Glidescope) in 728 patients
    • Cooper R.M., Pacey J.A., Bishop M.J., McCluskey S.A. Early clinical experience with a new videolaryngoscope (Glidescope) in 728 patients. Can J Anaesth 2005, 52:191-198.
    • (2005) Can J Anaesth , vol.52 , pp. 191-198
    • Cooper, R.M.1    Pacey, J.A.2    Bishop, M.J.3    McCluskey, S.A.4
  • 8
    • 35148891635 scopus 로고    scopus 로고
    • The clinical assessment of Glidescope in orotracheal intubation under general anesthesia
    • Xue F.S., Zhang G.H., Liu J., et al. The clinical assessment of Glidescope in orotracheal intubation under general anesthesia. Minerva Anestesiol 2007, 73:451-457.
    • (2007) Minerva Anestesiol , vol.73 , pp. 451-457
    • Xue, F.S.1    Zhang, G.H.2    Liu, J.3
  • 9
    • 33646532277 scopus 로고    scopus 로고
    • An evaluation of the Glidescope, a new video laryngoscope for difficult airways: a manikin study
    • Benjamin F.J., Boon D., French R.A. An evaluation of the Glidescope, a new video laryngoscope for difficult airways: a manikin study. Eur J Anaesthesiol 2006, 23:517-521.
    • (2006) Eur J Anaesthesiol , vol.23 , pp. 517-521
    • Benjamin, F.J.1    Boon, D.2    French, R.A.3
  • 10
    • 36749093518 scopus 로고    scopus 로고
    • The Glidescope-specific rigid stylet and standard malleable stylet are equally effective for Glidescope use
    • Turkstra T.P., Harle C.C., Armstrong K.P., et al. The Glidescope-specific rigid stylet and standard malleable stylet are equally effective for Glidescope use. Can J Anaesth 2007, 54:891-896.
    • (2007) Can J Anaesth , vol.54 , pp. 891-896
    • Turkstra, T.P.1    Harle, C.C.2    Armstrong, K.P.3
  • 11
    • 65349173573 scopus 로고    scopus 로고
    • Videolaryngoscopy in the management of the difficult airway: a comparison with the Macintosh blade
    • Stroumpoulis K., Pagoulatou A., Violari M., et al. Videolaryngoscopy in the management of the difficult airway: a comparison with the Macintosh blade. Eur J Anaesthesiol 2009, 26:218-222.
    • (2009) Eur J Anaesthesiol , vol.26 , pp. 218-222
    • Stroumpoulis, K.1    Pagoulatou, A.2    Violari, M.3
  • 13
    • 0035148486 scopus 로고    scopus 로고
    • Misplaced endotracheal tubes by paramedics in an urban emergency medical services system
    • Katz S.H., Falk J.L. Misplaced endotracheal tubes by paramedics in an urban emergency medical services system. Ann Emerg Med 2001, 37:32-37.
    • (2001) Ann Emerg Med , vol.37 , pp. 32-37
    • Katz, S.H.1    Falk, J.L.2
  • 14
    • 61649085915 scopus 로고    scopus 로고
    • ® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation in manikins
    • ® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation in manikins. BMC Emerg Med 2009, 9:2.
    • (2009) BMC Emerg Med , vol.9 , pp. 2
    • Nasim, S.1    Maharaj, C.H.2    Butt, I.3
  • 15
    • 11444255353 scopus 로고    scopus 로고
    • The Glidescope system: a clinical assessment of performance
    • Rai M.R., Dering A., Verghese C. The Glidescope system: a clinical assessment of performance. Anaesthesia 2005, 60:60-64.
    • (2005) Anaesthesia , vol.60 , pp. 60-64
    • Rai, M.R.1    Dering, A.2    Verghese, C.3
  • 16
    • 13544263512 scopus 로고    scopus 로고
    • Evaluation of ease of intubation with the Glidescope or Macintosh laryngoscope by anaesthetists in simulated easy and difficult laryngoscopy
    • Lim T.J., Lim Y., Liu E.H.C. Evaluation of ease of intubation with the Glidescope or Macintosh laryngoscope by anaesthetists in simulated easy and difficult laryngoscopy. Anaesthesia 2005, 60:180-183.
    • (2005) Anaesthesia , vol.60 , pp. 180-183
    • Lim, T.J.1    Lim, Y.2    Liu, E.H.C.3
  • 17
    • 54249167043 scopus 로고    scopus 로고
    • Comparison of Macintosh, Truview EVO2, Glidescope, and Airwayscope laryngoscope use in patients with cervical spine immobilization
    • Malik M.A., Maharaj C.H., Harte B.H., Laffey J.G. Comparison of Macintosh, Truview EVO2, Glidescope, and Airwayscope laryngoscope use in patients with cervical spine immobilization. Br J Anaesth 2008, 101:723-730.
    • (2008) Br J Anaesth , vol.101 , pp. 723-730
    • Malik, M.A.1    Maharaj, C.H.2    Harte, B.H.3    Laffey, J.G.4
  • 19
    • 58749099150 scopus 로고    scopus 로고
    • Laryngoscopy via Macintosh blade versus Glidescope: success rate and time for endotracheal intubation in untrained medical personnel
    • Nouruzi-Sedeh P., Schumann M., Groeben H. Laryngoscopy via Macintosh blade versus Glidescope: success rate and time for endotracheal intubation in untrained medical personnel. Anesthesiology 2009, 110:32-37.
    • (2009) Anesthesiology , vol.110 , pp. 32-37
    • Nouruzi-Sedeh, P.1    Schumann, M.2    Groeben, H.3
  • 20
    • 0344653608 scopus 로고    scopus 로고
    • Learning manual skills in anesthesiology: is there a recommended number of cases for anesthetic procedures?
    • Konrad C., Schüpfer G., Wietlisbach M., Gerber H. Learning manual skills in anesthesiology: is there a recommended number of cases for anesthetic procedures?. Anesth Analg 1998, 86:635-639.
    • (1998) Anesth Analg , vol.86 , pp. 635-639
    • Konrad, C.1    Schüpfer, G.2    Wietlisbach, M.3    Gerber, H.4
  • 21
    • 72049107444 scopus 로고    scopus 로고
    • Utility of the Pentax-AWS without interruption of chest compression: comparison of the Macintosh laryngoscope with the Pentax-AWS in manikin model
    • Han S.K., Shin D.H., Choi P.C. Utility of the Pentax-AWS without interruption of chest compression: comparison of the Macintosh laryngoscope with the Pentax-AWS in manikin model. Resuscitation 2010, 81:69-73.
    • (2010) Resuscitation , vol.81 , pp. 69-73
    • Han, S.K.1    Shin, D.H.2    Choi, P.C.3
  • 22
    • 78349266744 scopus 로고    scopus 로고
    • Assessment of the speed and ease of insertion of three supraglottic airway devices by paramedics: a manikin study
    • Castle N., Owen R., Hann M., Naidoo R., Reeves D. Assessment of the speed and ease of insertion of three supraglottic airway devices by paramedics: a manikin study. Emerg Med J 2010, 27:860-863.
    • (2010) Emerg Med J , vol.27 , pp. 860-863
    • Castle, N.1    Owen, R.2    Hann, M.3    Naidoo, R.4    Reeves, D.5
  • 23
    • 71749104416 scopus 로고    scopus 로고
    • Randomized crossover comparison between the i-gel and the LMA-Unique in anaesthetized, paralysed adults
    • Uppal V., Gangaiah S., Fletcher G., Kinsella J. Randomized crossover comparison between the i-gel and the LMA-Unique in anaesthetized, paralysed adults. Br J Anaesth 2009, 103:882-885.
    • (2009) Br J Anaesth , vol.103 , pp. 882-885
    • Uppal, V.1    Gangaiah, S.2    Fletcher, G.3    Kinsella, J.4
  • 24
    • 66349096639 scopus 로고    scopus 로고
    • Prehospital airway management on rescue helicopters in the United Kingdom
    • Schmid M., Mang H., Ey K., Schüttler J. Prehospital airway management on rescue helicopters in the United Kingdom. Anaesthesia 2009, 64:625-631.
    • (2009) Anaesthesia , vol.64 , pp. 625-631
    • Schmid, M.1    Mang, H.2    Ey, K.3    Schüttler, J.4
  • 25
    • 66149138753 scopus 로고    scopus 로고
    • New devices and techniques for airway management
    • Agrò F.E., Cataldo R., Mattei A. New devices and techniques for airway management. Minerva Anestesiol 2009, 75:141-149.
    • (2009) Minerva Anestesiol , vol.75 , pp. 141-149
    • Agrò, F.E.1    Cataldo, R.2    Mattei, A.3
  • 26
    • 0030622475 scopus 로고    scopus 로고
    • Combitube, laryngeal mask, and oral airway: a randomized prehospital comparative study of ventilatory device effectiveness and costeffectiveness in 470 cases of cardiorespiratory arrest
    • Rumball C.J., MacDonald D., The P.T.L. Combitube, laryngeal mask, and oral airway: a randomized prehospital comparative study of ventilatory device effectiveness and costeffectiveness in 470 cases of cardiorespiratory arrest. Prehosp Emerg Care 1997, 1:1-10.
    • (1997) Prehosp Emerg Care , vol.1 , pp. 1-10
    • Rumball, C.J.1    MacDonald, D.2    The, P.T.L.3
  • 27
    • 0028505021 scopus 로고
    • Immediate management of the airway during cardiopulmonary resuscitation in a hospital without a resident anaesthesiologist
    • Verghese C., Prior-Willeard P.F., Baskett P.J. Immediate management of the airway during cardiopulmonary resuscitation in a hospital without a resident anaesthesiologist. Eur J Emerg Med 1994, 1:123-125.
    • (1994) Eur J Emerg Med , vol.1 , pp. 123-125
    • Verghese, C.1    Prior-Willeard, P.F.2    Baskett, P.J.3
  • 28
    • 0032043889 scopus 로고    scopus 로고
    • Choice of airway devices for 12,020 cases of nontraumatic cardiac arrest in Japan
    • Tanigawa K., Shigematsu A. Choice of airway devices for 12,020 cases of nontraumatic cardiac arrest in Japan. Prehosp Emerg Care 1998, 2:96-100.
    • (1998) Prehosp Emerg Care , vol.2 , pp. 96-100
    • Tanigawa, K.1    Shigematsu, A.2
  • 29
    • 0028157794 scopus 로고
    • The use of the laryngeal mask airway by nurses during cardiopulmonary resuscitation: results of a multicentre trial
    • The use of the laryngeal mask airway by nurses during cardiopulmonary resuscitation: results of a multicentre trial. Anaesthesia 1994, 49:3-7.
    • (1994) Anaesthesia , vol.49 , pp. 3-7
  • 30
    • 85005248765 scopus 로고
    • The laryngeal mask in prehospital emergency care
    • Grantham H., Phillips G., Gilligan J.E. The laryngeal mask in prehospital emergency care. Emerg Med 1994, 6:193-197.
    • (1994) Emerg Med , vol.6 , pp. 193-197
    • Grantham, H.1    Phillips, G.2    Gilligan, J.E.3
  • 31
    • 0028107204 scopus 로고
    • The use of the laryngeal mask airway in CPR
    • Kokkinis K. The use of the laryngeal mask airway in CPR. Resuscitation 1994, 27:9-12.
    • (1994) Resuscitation , vol.27 , pp. 9-12
    • Kokkinis, K.1
  • 32
    • 0027312601 scopus 로고
    • The laryngeal mask in cardiopulmonary resuscitation in a district general hospital: a preliminary communication
    • Leach A., Alexander C.A., Stone B. The laryngeal mask in cardiopulmonary resuscitation in a district general hospital: a preliminary communication. Resuscitation 1993, 25:245-248.
    • (1993) Resuscitation , vol.25 , pp. 245-248
    • Leach, A.1    Alexander, C.A.2    Stone, B.3
  • 33
    • 0027489233 scopus 로고
    • Emergency intubation with the Combitube: comparison with the endotracheal airway
    • Staudinger T., Brugger S., Watschinger B., et al. Emergency intubation with the Combitube: comparison with the endotracheal airway. Ann Emerg Med 1993, 22:1573-1575.
    • (1993) Ann Emerg Med , vol.22 , pp. 1573-1575
    • Staudinger, T.1    Brugger, S.2    Watschinger, B.3
  • 34
    • 34250643975 scopus 로고    scopus 로고
    • Evaluation of four manikins as simulators for teaching airway management procedures specified in the Difficult Airway Society guidelines, and other advanced airway skills
    • Jordan G.M., Silsby J., Bayley G., Cook T.M., Difficult Airway S Evaluation of four manikins as simulators for teaching airway management procedures specified in the Difficult Airway Society guidelines, and other advanced airway skills. Anaesthesia 2007, 62:708-712.
    • (2007) Anaesthesia , vol.62 , pp. 708-712
    • Jordan, G.M.1    Silsby, J.2    Bayley, G.3    Cook, T.M.4    Difficult Airway, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.