Feasibility of near real-time lesion assessment during radiofrequency catheter ablation in humans using acoustic radiation force impulse imaging

Author keywords

acoustic radiation force impulse imaging; atrial fibrillation; atrial flutter; electroanatomical mapping; intracardiac echocardiography; lesion assessment; transcatheter radiofrequency ablation

Indexed keywords

ACOUSTIC RADIATION FORCE IMPULSE IMAGING; ADULT; ARTICLE; CARDIAC MAPPING SYSTEM; CATHETER ABLATION; CLINICAL ARTICLE; CONTROLLED STUDY; FEASIBILITY STUDY; FEMALE; HEART ATRIUM FIBRILLATION; HEART ATRIUM FLUTTER; HUMAN; INTRACARDIAC ECHOCARDIOGRAPHY; MALE; MIDDLE AGED; OUTCOME ASSESSMENT; PRIORITY JOURNAL; REAL TIME ULTRASOUND SCANNER; ATRIAL FIBRILLATION; CARDIOVASCULAR SURGERY; CLINICAL TRIAL; COMPUTER ASSISTED SURGERY; COMPUTER SYSTEM; ECHOCARDIOGRAPHY; ECHOGRAPHY; ELASTOGRAPHY; PROCEDURES; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; TREATMENT OUTCOME;

EID: 84926421687     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/jce.12514     Document Type: Article
Times cited : (22)

References (34)
  • 2
    • 84878064710 scopus 로고    scopus 로고
    • Transmural conduction is the predominant mechanism of breakthrough during atrial fibrillation: Evidence from simultaneous endo-epicardial high-density activation mapping
    • Eckstein J, Zeemering S, Linz D, Maesen B, Verheule S, van Hunnik A, Crijns H, Allessie MA, Schotten U,: Transmural conduction is the predominant mechanism of breakthrough during atrial fibrillation: Evidence from simultaneous endo-epicardial high-density activation mapping. Circ Arrhythm Electrophysiol 2013; 6: 334-341.
    • (2013) Circ Arrhythm Electrophysiol , vol.6 , pp. 334-341
    • Eckstein, J.1    Zeemering, S.2    Linz, D.3    Maesen, B.4    Verheule, S.5    Van Hunnik, A.6    Crijns, H.7    Allessie, M.A.8    Schotten, U.9
  • 5
    • 84857071447 scopus 로고    scopus 로고
    • The yin and yang of convective cooling in radiofrequency catheter ablation
    • Haines DE,: The yin and yang of convective cooling in radiofrequency catheter ablation. Circ Arrhythm Electrophysiol 2011; 4: 794-795.
    • (2011) Circ Arrhythm Electrophysiol , vol.4 , pp. 794-795
    • Haines, D.E.1
  • 12
    • 33646776427 scopus 로고    scopus 로고
    • Ultrasonic imaging of the mechanical properties of tissues using localized, transient acoustic radiation force
    • Nightingale K, Palmeri M, Frinkley K, Sharma A, Zhai L, Trahey G,: Ultrasonic imaging of the mechanical properties of tissues using localized, transient acoustic radiation force. Int Conf Acoust Spee 2005; 5: 981-984.
    • (2005) Int Conf Acoust Spee , vol.5 , pp. 981-984
    • Nightingale, K.1    Palmeri, M.2    Frinkley, K.3    Sharma, A.4    Zhai, L.5    Trahey, G.6
  • 15
    • 84867861083 scopus 로고    scopus 로고
    • Intracardiac acoustic radiation force impulse imaging: A novel imaging method for intraprocedural evaluation of radiofrequency ablation lesions
    • Eyerly SA, Bahnson TD, Koontz JI, Bradway DP, Dumont DM, Trahey GE, Wolf PD,: Intracardiac acoustic radiation force impulse imaging: A novel imaging method for intraprocedural evaluation of radiofrequency ablation lesions. Heart Rhythm 2012; 9: 1855-1862.
    • (2012) Heart Rhythm , vol.9 , pp. 1855-1862
    • Eyerly, S.A.1    Bahnson, T.D.2    Koontz, J.I.3    Bradway, D.P.4    Dumont, D.M.5    Trahey, G.E.6    Wolf, P.D.7
  • 17
    • 0029344834 scopus 로고
    • An axial velocity estimator for ultrasound blood-flow imaging, based on a full evaluation of the doppler equation by means of a 2-dimensional autocorrelation approach
    • Loupas T, Powers JT, Gill RW,: An axial velocity estimator for ultrasound blood-flow imaging, based on a full evaluation of the doppler equation by means of a 2-dimensional autocorrelation approach. IEEE Trans Ultrason Ferroelectr Freq Control 1995; 42: 672-688.
    • (1995) IEEE Trans Ultrason Ferroelectr Freq Control , vol.42 , pp. 672-688
    • Loupas, T.1    Powers, J.T.2    Gill, R.W.3
  • 19
    • 29144509586 scopus 로고    scopus 로고
    • Analysis of contrast in images generated with transient acoustic radiation force
    • Nightingale K, Palmeri M, Trahey G,: Analysis of contrast in images generated with transient acoustic radiation force. Ultrasound Med Biol 2006; 32: 61-72.
    • (2006) Ultrasound Med Biol , vol.32 , pp. 61-72
    • Nightingale, K.1    Palmeri, M.2    Trahey, G.3
  • 20
    • 77952719020 scopus 로고    scopus 로고
    • Mapping myocardial elasticity changes after RF-ablation using supersonic shear imaging
    • Pernot M, Mace E, Dubois R, Couade M, Fink M, Tanter M,: Mapping myocardial elasticity changes after RF-ablation using supersonic shear imaging. Comput Cardiol, 2009; 2009: 793-796.
    • (2009) Comput Cardiol , vol.2009 , pp. 793-796
    • Pernot, M.1    Mace, E.2    Dubois, R.3    Couade, M.4    Fink, M.5    Tanter, M.6
  • 21
    • 0036405394 scopus 로고    scopus 로고
    • Denaturation of collagen via heating: An irreversible rate process
    • Wright NT, Humphrey JD,: Denaturation of collagen via heating: An irreversible rate process. Annu Rev Biomed Eng 2002; 4: 109-128.
    • (2002) Annu Rev Biomed Eng , vol.4 , pp. 109-128
    • Wright, N.T.1    Humphrey, J.D.2
  • 23
    • 77951152646 scopus 로고    scopus 로고
    • An in vitro assessment of acoustic radiation force impulse imaging for visualizing cardiac radiofrequency ablation lesions
    • Eyerly SA, Hsu SJ, Agashe SH, Trahey GE, Li Y, Wolf PD,: An in vitro assessment of acoustic radiation force impulse imaging for visualizing cardiac radiofrequency ablation lesions. J Cardiovasc Electrophysiol 2010; 21: 557-563.
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 557-563
    • Eyerly, S.A.1    Hsu, S.J.2    Agashe, S.H.3    Trahey, G.E.4    Li, Y.5    Wolf, P.D.6
  • 24
    • 84875819304 scopus 로고    scopus 로고
    • In vitro monitoring of the dynamic elasticity changes during radiofrequency ablation with acoustic radiation force impulse imaging
    • Eyerly SA, Dumont DM, Trahey GE, Wolf PD,: In vitro monitoring of the dynamic elasticity changes during radiofrequency ablation with acoustic radiation force impulse imaging. J Cardiovasc Electrophysiol 2013; 24: 472-473.
    • (2013) J Cardiovasc Electrophysiol , vol.24 , pp. 472-473
    • Eyerly, S.A.1    Dumont, D.M.2    Trahey, G.E.3    Wolf, P.D.4
  • 26
    • 64349104064 scopus 로고    scopus 로고
    • Ultrasound biosafety considerations for the practicing sonographer and sonologist
    • Nelson TR, Fowlkes JB, Abramowicz JS, Church CC,: Ultrasound biosafety considerations for the practicing sonographer and sonologist. J Ultrasound Med 2009; 28: 139-150.
    • (2009) J Ultrasound Med , vol.28 , pp. 139-150
    • Nelson, T.R.1    Fowlkes, J.B.2    Abramowicz, J.S.3    Church, C.C.4
  • 28
    • 0141618302 scopus 로고    scopus 로고
    • Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation
    • Cappato R, Negroni S, Pecora D, Bentivegna S, Lupo PP, Carolei A, Esposito C, Furlanello F, De Ambroggi L,: Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation. Circulation 2003; 108: 1599-1604.
    • (2003) Circulation , vol.108 , pp. 1599-1604
    • Cappato, R.1    Negroni, S.2    Pecora, D.3    Bentivegna, S.4    Lupo, P.P.5    Carolei, A.6    Esposito, C.7    Furlanello, F.8    De Ambroggi, L.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.