메뉴 건너뛰기




Volumn 21, Issue 5, 2010, Pages 557-563

An in vitro assessment of acoustic radiation force impulse imaging for visualizing cardiac radiofrequency ablation lesions

Author keywords

Acoustic radiation force impulse imaging; Atrial arrhythmias; Atrial fibrillation; Intracardiac echocardiography; Radiofrequency catheter ablation

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; B SCAN; CATHETER ABLATION; CONTROLLED STUDY; HEART SUPRAVENTRICULAR ARRHYTHMIA; IMAGE QUALITY; IN VITRO STUDY; NONHUMAN; PRIORITY JOURNAL; SWINE;

EID: 77951152646     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/j.1540-8167.2009.01664.x     Document Type: Article
Times cited : (49)

References (34)
  • 1
    • 0030106206 scopus 로고    scopus 로고
    • Ablation for the treatment of arrhythmias
    • McRury ID, Haines DE : Ablation for the treatment of arrhythmias. Proc IEEE 1996 84 : 404 416.
    • (1996) Proc IEEE , vol.84 , pp. 404-416
    • McRury, I.D.1    Haines, D.E.2
  • 4
    • 0027179535 scopus 로고
    • Role of radiofrequency ablation in the management of supraventricular arrhythmias: Experience in 760 consecutive patients
    • Kay GN, Epstein AE, Dailey SM, Plumb VJ : Role of radiofrequency ablation in the management of supraventricular arrhythmias: Experience in 760 consecutive patients. J Cardiovasc Electrophysiol 1993 4 : 371 389.
    • (1993) J Cardiovasc Electrophysiol , vol.4 , pp. 371-389
    • Kay, G.N.1    Epstein, A.E.2    Dailey, S.M.3    Plumb, V.J.4
  • 6
    • 33646714868 scopus 로고    scopus 로고
    • Effects of gap geometry on conduction through discontinuous radiofrequency lesions
    • P'erez FJ, Wood MA, Schubert CM : Effects of gap geometry on conduction through discontinuous radiofrequency lesions. Circulation 2006 113 : 1723 1729.
    • (2006) Circulation , vol.113 , pp. 1723-1729
    • P'Erez, F.J.1    Wood, M.A.2    Schubert, C.M.3
  • 7
    • 0033208610 scopus 로고    scopus 로고
    • Temperature-controlled radiofrequency ablation of cardiac tissue: An in vitro study of the impact of electrode orientation, electrode tissue contact pressure and external convective cooling
    • Petersen HH, Chen X, Pietersen A, Svendsen JH, Haunso S : Temperature-controlled radiofrequency ablation of cardiac tissue: An in vitro study of the impact of electrode orientation, electrode tissue contact pressure and external convective cooling. J Interv Card Electrophysiol 1999 3 : 257 262.
    • (1999) J Interv Card Electrophysiol , vol.3 , pp. 257-262
    • Petersen, H.H.1    Chen, X.2    Pietersen, A.3    Svendsen, J.H.4    Haunso, S.5
  • 8
    • 40149110680 scopus 로고    scopus 로고
    • Contrasting effects of convective flow on catheter ablation lesion size: Cryo versus radiofrequency energy
    • Pilcher TA, Saul JP, Hlavacek AM, Haemmerich D : Contrasting effects of convective flow on catheter ablation lesion size: Cryo versus radiofrequency energy. Pacing Clin Electrophysiol 2008 31 : 300 307.
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 300-307
    • Pilcher, T.A.1    Saul, J.P.2    Hlavacek, A.M.3    Haemmerich, D.4
  • 10
    • 0031865375 scopus 로고    scopus 로고
    • Electroanatomical mapping of the heart: Basic concepts and implications for the treatment of cardiac arrhythmias
    • Gepstein L, Evans SJ : Electroanatomical mapping of the heart: Basic concepts and implications for the treatment of cardiac arrhythmias. Pacing Clin Electrophysiol 1998 21 : 1268 1278.
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 1268-1278
    • Gepstein, L.1    Evans, S.J.2
  • 11
    • 1642398327 scopus 로고    scopus 로고
    • Resumption of electrical conduction in previously isolated pulmonary veins: Rationale for a different strategy
    • Nanthakumar K, Plumb VJ, Epstein AE, Veenhuyzen GD, Link D, Kay GN : Resumption of electrical conduction in previously isolated pulmonary veins: Rationale for a different strategy Circulation 2004 109 : 1226 1229.
    • (2004) Circulation , vol.109 , pp. 1226-1229
    • Nanthakumar, K.1    Plumb, V.J.2    Epstein, A.E.3    Veenhuyzen, G.D.4    Link, D.5    Kay, G.N.6
  • 14
    • 27744592657 scopus 로고    scopus 로고
    • Incidence and predictors of pulmonary vein stenosis following catheter ablation of atrial fibrillation using the anatomic pulmonary vein ablation approach: Results from paired magnetic resonance imaging
    • DOI 10.1111/j.1540-8167.2005.40680.x
    • Dong J, Vasamreddy CR, Jayam V, Dalal D, Dickfeld T, Eldadah Z, Meininger G, Halperin HR, Berger R, Bluemke DA, Calkins H : Incidence and predictors of pulmonary vein stenosis following catheter ablation of atrial fibrillation using the anatomic pulmonary vein ablation approach: Results from paired magnetic resonance imaging. J Cardiovasc Electrophysiol 2005 16 : 845 852. (Pubitemid 41623774)
    • (2005) Journal of Cardiovascular Electrophysiology , vol.16 , Issue.8 , pp. 845-852
    • Dong, J.1    Vasamreddy, C.R.2    Jayam, V.3    Dalal, D.4    Dickfeld, T.5    Eldadah, Z.6    Meininger, G.7    Halperin, H.R.8    Berger, R.9    Bluemke, D.A.10    Calkins, H.11
  • 15
  • 16
    • 0032926515 scopus 로고    scopus 로고
    • Catheter ablation of cardiac arrhythmias: Usually cure, but complications may occur
    • Wellens HJ : Catheter ablation of cardiac arrhythmias: Usually cure, but complications may occur. Circulation 1999 99 : 195 197.
    • (1999) Circulation , vol.99 , pp. 195-197
    • Wellens, H.J.1
  • 17
    • 0032935092 scopus 로고    scopus 로고
    • Catheter ablation of accessory pathways, atrioventricular nodal reentrant tachycardia, and the atrioventricular junction: Final results of a prospective, multicenter clinical trial. the Atakr Multicenter Investigators Group
    • Calkins H, Yong P, Miller JM, Olshansky B, Carlson M, Saul JP, Huang SK, Liem LB, Klein LS, Moser SA, Bloch DA, Gillette P, Prystowsky E : Catheter ablation of accessory pathways, atrioventricular nodal reentrant tachycardia, and the atrioventricular junction: Final results of a prospective, multicenter clinical trial. The Atakr Multicenter Investigators Group. Circulation 1999 99 : 262 270.
    • (1999) Circulation , vol.99 , pp. 262-270
    • Calkins, H.1    Yong, P.2    Miller, J.M.3    Olshansky, B.4    Carlson, M.5    Saul, J.P.6    Huang, S.K.7    Liem, L.B.8    Klein, L.S.9    Moser, S.A.10    Bloch, D.A.11    Gillette, P.12    Prystowsky, E.13
  • 20
    • 0036663803 scopus 로고    scopus 로고
    • Observations of tissue response to acoustic radiation force: Opportunities for imaging
    • Nightingale K, Bentley R, Trahey GE : Observations of tissue response to acoustic radiation force: Opportunities for imaging. Ultrason Imaging 2002 24 : 100 108.
    • (2002) Ultrason Imaging , vol.24 , pp. 100-108
    • Nightingale, K.1    Bentley, R.2    Trahey, G.E.3
  • 21
    • 0036218695 scopus 로고    scopus 로고
    • Acoustic radiation force impulse imaging: In vivo demonstration of clinical feasibility
    • Nightingale K, Soo M, Nightingale R, Trahey G : Acoustic radiation force impulse imaging: In vivo demonstration of clinical feasibility. Ultrasound Med Biol 2002 28 : 227 235.
    • (2002) Ultrasound Med Biol , vol.28 , pp. 227-235
    • Nightingale, K.1    Soo, M.2    Nightingale, R.3    Trahey, G.4
  • 22
    • 14744279544 scopus 로고    scopus 로고
    • Monitoring stiffness changes in lesions after radiofrequency ablation at different temperatures and durations of ablation
    • Bharat S, Techavipoo U, Kiss MZ, Liu W, Varghese T : Monitoring stiffness changes in lesions after radiofrequency ablation at different temperatures and durations of ablation. Ultrasound Med Biol 2005 31 : 415 422.
    • (2005) Ultrasound Med Biol , vol.31 , pp. 415-422
    • Bharat, S.1    Techavipoo, U.2    Kiss, M.Z.3    Liu, W.4    Varghese, T.5
  • 23
    • 0015414214 scopus 로고
    • Pathological characteristics of experimental thermal lesions. Comparison of induction heating and radiofrequency electrocoagulation
    • Zervas NT, Kuwayama A : Pathological characteristics of experimental thermal lesions. Comparison of induction heating and radiofrequency electrocoagulation. J Neurosurg 1972 37 : 418 422.
    • (1972) J Neurosurg , vol.37 , pp. 418-422
    • Zervas, N.T.1    Kuwayama, A.2
  • 26
    • 0029856970 scopus 로고    scopus 로고
    • Reproducibility of quantitative measurements from intracoronary ultrasound images. Beat-to-beat variability and influence of the cardiac cycle
    • Peters RJ, Kok WE, Rijsterborgh H, van Dijk M, Koch KT, Piek JJ, David GK, Visser CA : Reproducibility of quantitative measurements from intracoronary ultrasound images. Beat-to-beat variability and influence of the cardiac cycle. Eur Heart J 1996 17 : 1593 1599.
    • (1996) Eur Heart J , vol.17 , pp. 1593-1599
    • Peters, R.J.1    Kok, W.E.2    Rijsterborgh, H.3    Van Dijk, M.4    Koch, K.T.5    Piek, J.J.6    David, G.K.7    Visser, C.A.8
  • 28
    • 34547860489 scopus 로고    scopus 로고
    • One-puncture, double-transseptal catheterization manoeuvre in the catheter ablation of atrial fibrillation
    • Yamada T, McElderry HT, Epstein AE, Plumb VJ, Kay GN : One-puncture, double-transseptal catheterization manoeuvre in the catheter ablation of atrial fibrillation. Europace 2007 9 : 487 489.
    • (2007) Europace , vol.9 , pp. 487-489
    • Yamada, T.1    McElderry, H.T.2    Epstein, A.E.3    Plumb, V.J.4    Kay, G.N.5
  • 29
    • 33947237987 scopus 로고    scopus 로고
    • Variation in left atrial transmural wall thickness at sites commonly targeted for ablation of atrial fibrillation
    • Hall B, Jeevanantham V, Simon R, Filippone J, Vorobiof G, Daubert J : Variation in left atrial transmural wall thickness at sites commonly targeted for ablation of atrial fibrillation. J Interv Card Electrophysiol 2006 17 : 127 132.
    • (2006) J Interv Card Electrophysiol , vol.17 , pp. 127-132
    • Hall, B.1    Jeevanantham, V.2    Simon, R.3    Filippone, J.4    Vorobiof, G.5    Daubert, J.6
  • 32
    • 35448952635 scopus 로고    scopus 로고
    • In vivo assessment of myocardial stiffness with acoustic radiation force impulse imaging
    • Hsu SJ, Bouchard RR, Dumont DM, Wolf PD, Trahey GE : In vivo assessment of myocardial stiffness with acoustic radiation force impulse imaging. Ultrasound Med Biol 2007 33 : 1706 1719.
    • (2007) Ultrasound Med Biol , vol.33 , pp. 1706-1719
    • Hsu, S.J.1    Bouchard, R.R.2    Dumont, D.M.3    Wolf, P.D.4    Trahey, G.E.5
  • 34
    • 70450197366 scopus 로고    scopus 로고
    • Early detection of pulmonary vein reconnection after isolation in patients with paroxysmal atrial fibrillation: A comparison of atp-induction and reassessment at 30 minutes postisolation
    • Jiang CY, Jiang RH, Matsuo S, Liu Q, Fan YQ, Zhang ZW, Fu GS : Early detection of pulmonary vein reconnection after isolation in patients with paroxysmal atrial fibrillation: A comparison of atp-induction and reassessment at 30 minutes postisolation. J Cardiovasc Electrophysiol 2009 20 : 1382 1387.
    • (2009) J Cardiovasc Electrophysiol , vol.20 , pp. 1382-1387
    • Jiang, C.Y.1    Jiang, R.H.2    Matsuo, S.3    Liu, Q.4    Fan, Y.Q.5    Zhang, Z.W.6    Fu, G.S.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.